首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Traveling wave ion mobility spectrometry (TW IMS) is a new IMS method implemented in the Synapt IMS/mass spectrometry system (Waters). Despite its wide adoption, the foundations of TW IMS were only qualitatively understood and factors governing the ion transit time (the separation parameter) and resolution remained murky. Here we develop the theory of TW IMS using derivations and ion dynamics simulations. The key parameter is the ratio (c) of ion drift velocity at the steepest wave slope to wave speed. At low c, the ion transit velocity is proportional to the squares of mobility (K) and electric field intensity (E), as opposed to linear scaling in drift tube (DT) IMS and differential mobility analyzers. At higher c, the scaling deviates from quadratic in a way controlled by the waveform profile, becoming more gradual with the ideal triangular profile but first steeper and then more gradual for realistic profiles with variable E. At highest c, the transit velocity asymptotically approaches the wave speed. Unlike with DT IMS, the resolving power of TW IMS depends on mobility, scaling as K(1/2) in the low-c limit and less at higher c. A nonlinear dependence of the transit time on mobility means that the true resolving power of TW IMS differs from that indicated by the spectrum. A near-optimum resolution is achievable over an approximately 300-400% range of mobilities. The major predicted trends are in agreement with TW IMS measurements for peptide ions as a function of mobility, wave amplitude, and gas pressure. The issues of proper TW IMS calibration and ion distortion by field heating are also discussed. The new quantitative understanding of TW IMS separations allows rational optimization of instrument design and operation and improved spectral calibration.  相似文献   

2.
Field asymmetric waveform ion mobility spectrometry (FAIMS) has emerged as an analytical tool of broad utility, especially in conjunction with mass spectrometry. Of particular promise is the use of FAIMS and 2-D ion mobility methods that combine FAIMS with conventional IMS to resolve and characterize protein and other macromolecular conformers. However, FAIMS operation requires a strong electric field, and ions are inevitably heated by energetic collisions with buffer gas molecules. This may induce ion isomerization or dissociation, which distort the separation properties of FAIMS (and subsequent stages) or reduce instrumental sensitivity. As FAIMS employs a periodic waveform, whether those processes are controlled by ion temperature at maximum or average field intensity has been debated. Here we address this issue by measuring the unfolding of compact ubiquitin ion geometries as a function of waveform amplitude (dispersion field, E(D)) and gas temperature, T. The field heating is quantified by matching the dependences of structural transitions on E(D) and T: increasing E(D) from 12 to 16 or from 16 to 20 kV/cm is equivalent to heating the (N2) gas by approximately 15-25 degrees C. The magnitude of field heating for any E(D) can be estimated using the two-temperature theory, and raising E(D) by 4 kV/cm augments heating by approximately 15-30 degrees C for maximum and approximately 4-8 degrees C for average field in the FAIMS cycle. Hence, isomerization of ions in FAIMS appears to be determined by the excitation at waveform peaks.  相似文献   

3.
Differential mobility spectrometry (DMS) (see Buryakov, I. A.; Krylov, E. V.; Nazarov, E. G.; Rasulev, U. Kh. Int. J. Mass Spectrom. Ion Processes 1993, 128, 143-148), also commonly referred to as high-field asymmetric waveform ion mobility spectrometry (FAIMS) (see Purves, R. W.; Guevremont, R.; Day, S.; Pipich, C. W.; Matyjaszcyk, M. S. Rev. Sci. Instrum. 1998, 69, 4094-4105), is a rapidly advancing technology for gas-phase ion separation. The interfacing of DMS with mass spectrometry (MS) offers potential advantages over the use of mass spectrometry alone. Such advantages include improvements to mass spectral signal-to-noise, orthogonal/complementary ion separation to mass spectrometry, enhanced ion and complexation structural analysis, and the potential for rapid analyte quantitation. In this report, we investigate the use of our nanoESI-DMS-MS system to demonstrate differential mobility separation of peptides. The formation of higher order peptide aggregate ions (ion complexes) via electrospray ionization and the negative impact this has on DMS peptide separation are examined. The successful use of differential mobility drift gas modifiers (dopants) to reduce aggregate ion size and improve DMS peptide ion separation is presented. Following optimization of DMS peptide separation conditions, we examined next the feasibility of a new analytical platform which uses direct sample infusion with nanoESI-DMS-MS for ultrarapid analyte quantitation. Quantitation of a selected peptide from a semicomplex peptide mixture is presented. Initial feasibility results with this new approach demonstrate good accuracy and reproducibility, as well as an absolute mass sensitivity of 6.8 amol and a minimum dynamic range of 2500 for the peptide of interest. This report offers a first look at utilizing nanoESI-DMS-MS to create an ultrarapid (under 5 s) quantitative analysis platform and its potential in the high-throughput arena. Each ion separation technique, DMS and MS, offers orthogonal ion separation to one another, enhancing the overall specificity for this quantitative approach.  相似文献   

4.
Miniaturized ultra high field asymmetric waveform ion mobility spectrometry (ultra-FAIMS) combined with mass spectrometry (MS) has been applied to the analysis of standard and tryptic peptides, derived from α-1-acid glycoprotein, using electrospray and nanoelectrospray ion sources. Singly and multiply charged peptide ions were separated in the gas phase using ultra-FAIMS and detected by ion trap and time-of-flight MS. The small compensation voltage (CV) window for the transmission of singly charged ions demonstrates the ability of ultra-FAIMS-MS to generate pseudo-peptide mass fingerprints that may be used to simplify spectra and identify proteins by database searching. Multiply charged ions required a higher CV for transmission, and ions with different amino acid sequences may be separated on the basis of their differential ion mobility. A partial separation of conformers was also observed for the doubly charged ion of bradykinin. Selection on the basis of charge state and differential mobility prior to tandem mass spectrometry facilitates peptide and protein identification by allowing precursor ions to be identified with greater selectivity, thus reducing spectral complexity and enhancing MS detection.  相似文献   

5.
Ion mobility spectrometry (IMS) is a rapid, gas-phase separation technique that exhibits excellent separation of ions as a standalone instrument. However, IMS cannot achieve optimal separation power with both small and large ions simultaneously. Similar to the general elution problem in chromatography, fast ions are well resolved using a low electric field (50-150 V/cm), whereas slow drifting molecules are best separated using a higher electric field (250-500 V/cm). While using a low electric field, IMS systems tend to suffer from low ion transmission and low signal-to-noise ratios. Through the use a novel voltage algorithm, some of these effects can be alleviated. The electric field was swept from low to high while monitoring a specific drift time, and the resulting data were processed to create a 'voltage-sweep' spectrum. If an optimal drift time is calculated for each voltage and scanned simultaneously, a spectrum may be obtained with optimal separation throughout the mobility range. This increased the resolving power up to the theoretical maximum for every peak in the spectrum and extended the peak capacity of the IMS system, while maintaining accurate drift time measurements. These advantages may be extended to any IMS, requiring only a change in software.  相似文献   

6.
Recently, we introduced a new approach to chiral separation and analysis of amino acids by chiral complexation and electrospray high-field asymmetric waveform ion mobility spectrometry coupled to mass spectrometry (ESI-FAIMS-MS). In the present work, we extended this approach to the separation of the drug compound terbutaline. Terbutaline enantiomers were complexed with metal ions and an amino acid to form diastereomeric complexes of the type [M(II)(L-Ref)2((+)/(-)-A)-H](+), where M(II) is a divalent metal ion, L-Ref is an amino acid in its L-form, and A is the terbutaline analyte. When metal and reference compound were suitably chosen, these complexes were separable by FAIMS. We also detected and characterized larger clusters that were transmitted at distinct FAIMS compensation voltages (CV), disturbing data analysis by disintegrating after the FAIMS separation and forming complexes of the same composition [M(II)(L-Ref)2((+)/(-)-A)-H](+), thus giving rise to additional peaks in the FAIMS CV spectra. This undesired phenomenon could be largely avoided by adjusting the mass spectrometer skimmer voltages in such a way that said larger clusters remained intact. In the quantitative part of the present work, we achieved a limit of detection of 0.10% (-)-terbutaline in a sample of (+)-terbutaline. The limit of detection and analysis time per sample compared favorably to literature values for chiral terbutaline separation by HPLC and CE.  相似文献   

7.
Localization of the modification sites on peptides is challenging, particularly when multiple modifications or mixtures of localization isomers (variants) are involved. Such variants commonly coelute in liquid chromatography and may be undistinguishable in tandem mass spectrometry (MS/MS) for lack of unique fragments. Here, we have resolved the variants of singly and doubly phosphorylated peptides employing drift tube ion mobility spectrometry (IMS) coupled to time-of-flight mass spectrometry. Even with a moderate IMS resolving power of ~80-100, substantial separation was achieved for both 2+ and 3+ ions normally generated by electrospray ionization, including for the variants indistinguishable by MS/MS. Variants often exhibit a distribution of 3-D conformers, which can be adjusted for optimum IMS separation by prior field heating of ions in a funnel trap. The peak assignments were confirmed using MS/MS after IMS separation, but known species could be identified using just the ion mobility "tag". Avoiding the MS/MS step lowers the detection limit of localization variants to <100 amol, an order of magnitude better than that provided by electron transfer dissociation in an Orbitrap MS.  相似文献   

8.
The use of different drift gases to alter separation factors (alpha) in ion mobility spectrometry has been demonstrated. The mobility of a series of low molecular weight compounds and three small peptides was determined in four different drift gases. The drift gases chosen were helium, argon, nitrogen, and carbon dioxide. These drift gases provide a range of polarizabilities and molecular weights. In all instances, the compounds showed the greatest mobility in helium and the lowest mobility in carbon dioxide; however the percentage change of mobility for each compound was different, effectively changing the alpha value. The alpha value changes were primarily due to differences in drift gas polarizability but were also influenced by the mass of the drift gas. In addition, gas-phase ion radii were calculated in each of the different drift gases. These radii were then plotted against drift gas polarizability producing linear plots with r2 values greater than 0.99. The intercept of these plots provides the gas-phase radius of an ion in a nonpolarizing environment, whereas the slope is indicative of the magnitude of the ion's mobility change related to polarizability. It therefore, should be possible to separate any two compounds that have different slopes with the appropriate drift gas.  相似文献   

9.
A new ion mobility instrument that incorporates a low-field region for ion separation and a high-field region for collisional activation is described. In this approach, mixtures of ions are separated based on differences in their mobilities in a approximately 20-cm-long low-field ( approximately 5 V cm(-)(1)) region of a drift tube. As the ions approach the drift tube exit, they are exposed to a large focusing potential drop; at high fields, ions are efficiently collisionally activated and dissociate as they exit the drift tube. We have demonstrated this approach by examining the fragmentation pattern for electrosprayed bradykinin ions. These studies show that the activation process is highly tunable; it is possible to modulate the field such that precursor ion mass spectra as well as several high-field collision-induced fragmentation patterns can be obtained. The approach also appears to be a simple means of activating protein ions, as demonstrated by examining electrosprayed myoglobin ions.  相似文献   

10.
High-field asymmetric waveform ion mobility spectrometry (FAIMS) separates ions by utilizing the mobility differences of ions at high and low fields. The shape of the waveform is one of the essential features affecting the resolution, transmission, and separation of FAIMS. Due to practical circuitry advantages, sinusoidal asymmetric waveforms are typically used in FAIMS, whereas theoretical studies indicate that square asymmetric waveforms improve ion separation, resolution, and sensitivity. Results from FAIMS using square and sinusoidal waveforms are presented, and effects of the waveforms on ion separation are discussed. A FAIMS system interfaced with a quadrupole ion trap mass spectrometer was used in this study. FAIMS spectra were generated by scanning the compensation voltage (CV) while operating the mass spectrometer in total ion mode. The identification of ions was accomplished through mass spectra acquired at fixed values of ions' CVs. Square waveform evaluation was done by acquiring data at three frequencies and six duty cycles of the square waveform generator. The performance of FAIMS using square and sinusoidal waveforms at 250, 333, and 500 kHz frequencies was compared, and trends were identified. For all frequencies, the best response of FAIMS was achieved at the lower amplitudes and under the lower duty cycles of the square waveform generator. The separation of FAIMS was better at the higher frequencies. These results demonstrate the potential to incorporate square-wave FAIMS into the design of a miniature device for detection of explosives in the field. SIMION version 8.0, the ion trajectory modeling program, was utilized to optimize the performance of the miniature FAIMS cell and to validate experimental results.  相似文献   

11.
A consistent analytical model of nonlinear ion drift spectrometry for modern gas analyzers is developed. A procedure for determining the field dependence of the ion mobility using the experimental data is described. An ionogram is calculated for the case of a flat drift chamber and polynomial character of the field dependence of the ion mobility.  相似文献   

12.
根据高场非对称波形离子迁移谱(high-field asymmetric waveform ion mobility spectrometry,FAIMS)原理,设计了一种微型生化传感器.采用真空紫外灯离子源在大气压环境下对样品进行电离,紫外灯发射的光子能量为10.6 eV,波长116.5 nm.迁移区由上下两块紫铜金属平板电极构成,尺寸为10 mm×10 mm×1 mm.完成了高场非对称方波电源的设计,所输出的射频电压最大值为1 180 V,最小值为-480 V,频率189 kHz,占空比30%.以丙酮为实验样品,通过高场非对称波形离子迁移谱-质谱联用技术进行传感器的性能验证实验,实验结果表明所设计的基于FAIMS原理的生化传感器可以实现离子分离和过滤功能.基于SIMION软件对FAIMS生化传感器进行仿真分析,仿真与实验结果相符.最后利用硅片双面感应耦合等离子体(inductively coupled plasma,ICP)刻蚀和硅-玻璃键合工艺,加工出基于微机电系统(micro electro mechanical system,MEMS)技术的微型FAIMS传感器芯片.采用频率2 MHz、最大电压364 V、占空比30%的高场非对称方波电压进行FAIMS芯片实验.载气流速80 L/h,补偿电压从-10 V~3 V以0.1 V的步长扫描,得到了丙酮的FAIMS谱图,验证了芯片的性能.  相似文献   

13.
One difficulty in using ion mobility (IM) mass spectrometry (MS) to improve the specificity of peptide ion assignments is that IM separations are performed using a range of pressures, gas compositions, temperatures, and modes of separation, which makes it challenging to rapidly extract accurate shape parameters. We report collision cross section values (Ω) in both He and N(2) gases for 113 peptide ions determined directly from drift times measured in a low-pressure, ambient temperature drift cell with radio-frequency (rf) ion confinement. These peptide ions have masses ranging from 231 to 2969 Da, Ω(He) of 89-616 ?(2), and Ω(N(2)) of 151-801 ?(2); thus, they are ideal for calibrating results from proteomics experiments. These results were used to quantify the errors associated with traveling-wave Ω measurements of peptide ions and the errors concomitant with using drift times measured in N(2) gas to estimate Ω(He). More broadly, these results enable the rapid and accurate determination of calibrated Ω for peptide ions, which could be used as an additional parameter to increase the specificity of assignments in proteomics experiments.  相似文献   

14.
Field asymmetric waveform ion mobility spectrometry (FAIMS) has emerged as a powerful tool of broad utility for separation and characterization of gas-phase ions, especially in conjunction with mass spectrometry (MS). In FAIMS, ions are filtered by the dependence of mobility on electric field while being carried by gas flow through the analytical gap between two electrodes of either planar (p-) or cylindrical (c-) geometry. Most FAIMS/MS systems employ c-FAIMS because of its ease of coupling to MS, yet the merits of the two geometries have not been compared in detail. Here, a priori simulations reveal that reducing the FAIMS curvature always improves resolution at equal sensitivity. In particular, the resolving power of p-FAIMS exceeds that of c-FAIMS, typically by a factor of 2-4 depending on the ion species and carrier gas. We have constructed a new planar FAIMS incorporating a curtain plate interface for effective operation with an ESI ion source and joined to an MS using an ion funnel interface with a novel slit aperture. The resolution increases up to 4-fold over existing c-FAIMS, even though the analysis is approximately 2 times faster. This allows separation of species not feasible in previous FAIMS studies, e.g., protonated leucine and isoleucine or new bradykinin isomers. The improvement for protein conformers (of ubiquitin) is less significant, possibly because of multiple unresolved geometries.  相似文献   

15.
Differential mobility spectrometry (DMS) is a rapidly advancing technology for gas-phase ion separation. The interfacing of DMS with mass spectrometry (MS) offers potential advantages over the use of mass spectrometry alone. Such advantages include improvements to mass spectral signal/noise ratios, orthogonal/complementary ion separation to mass spectrometry, enhanced ion and complexation structural analysis, and potential for rapid analyte quantitation. The introduction of a new ESI-DMS-MS system and its utilization to aid in the understanding of DMS separation theory is described. A current contribution to DMS separation theory is one of an association/dissociation process between ions/molecules in the gas phase during the differential mobility separation. A model study was designed to investigate the molecular dynamics and chemical factors influencing the theorized association/dissociation process, and the mechanisms by which these gas-phase interactions affect an ion's DM behavior. Five piperidine analogues were selected as model analytes, and three alcohol drift gas dopants/modifiers were used to interrogate the analyte ions in the gas phase. Two proposed DMS separation mechanisms, introduced as Core and Fa?ade, corresponding to strong and weak attractions between ions/molecules in the gas phase, are detailed. The proposed mechanisms provide explanation for the observed changes in analyte separation by the various drift gas modifiers. Molecular modeling of the proposed mechanisms provides supportive data and demonstrates the potential for predictive optimization of analyte separation based on drift gas modifier effects.  相似文献   

16.
No Heading Carbon nanotubes (CNTs) are employed to construct field emitters to inject ions into liquid helium. The nanotube field emitter (NTFE) works at voltages as low as +380 V for positive ion and –100 V for negative ion when the diameter of CNTs is 1.4 nm. From the experimental results, we suppose that the NTFEs will works at the lower voltages if the CNTs being 1.4 nm or less in diameter are used.PACS numbers: 67.40.Jg, 79.70.+q.  相似文献   

17.
A tandem quadrupole ion trap/ion mobility spectrometer (QIT/IMS) has been constructed for structural analysis based on the gas-phase mobilities of mass-selected ions. The instrument combines the ion accumulation, manipulation, and mass-selection capabilities of a modified ion trap mass spectrometer with gas-phase electrophoretic separation in a custom-built ion mobility drift cell. The quadrupole ion trap may be operated as a conventional mass spectrometer, with ion detection using an off-axis dynode/multiplier arrangement, or as an ion source for the IMS drift cell. In the latter case, pulses of ions are ejected from the trap and transferred to the drift cell where mobility in the presence of helium buffer gas is determined by the collision cross section of the ion. Ions traversing the drift cell are detected by an in-line electron multiplier and the data processed with a multichannel scaler. Preliminary data are presented on instrumental performance characteristics and the application of QIT/ IMS to structural and conformational studies of aromatic ions and protonated amine/crown ether noncovalent complexes generated via ion/molecule reactions in the ion trap.  相似文献   

18.
Flow injection high field asymmetric waveform ion mobility spectrometry (FAIMS)-mass spectrometry (MS) methodology was developed for the detection and identification of chemical warfare (CW) agents in spiked food products. The CW agents, soman (GD), sarin (GB), tabun (GA), cyclohexyl sarin (GF), and four hydrolysis products, ethylphosphonic acid (EPA), methylphosphonic acid (MPA), pinacolyl methylphosphonic acid (Pin MPA), and isopropyl methylphosphonic acid (IMPA) were separated and detected by positive ion and negative ion atmospheric pressure ionization-FAIMS-MS. Under optimized conditions, the compensation voltages were 7.2 V for GD, 8.0 V for GA, 7.2 V for GF, 7.6 V for GB, 18.2 V for EPA, 25.9 V for MPA, -1.9 V for PinMPA, and +6.8 V for IMPA. Sample preparation was kept to a minimum, resulting in analysis times of 3 min or less per sample. The developed methodology was evaluated by spiking bottled water, canola oil, cornmeal, and honey samples at low microgram per gram (or microg/mL) levels with the CW agents or CW agent hydrolysis products. The detection limits observed for the CW agents in the spiked food samples ranged from 3 to 15 ng/mL in bottled water, 1-33 ng/mL in canola oil, 1-34 ng/g in cornmeal, and 13-18 ng/g in honey. Detection limits were much higher for the CW agent hydrolysis products, with only MPA being detected in spiked honey samples.  相似文献   

19.
This article introduces the concept of chiral ion mobility spectrometry (CIMS) and presents examples demonstrating the gas-phase separation of enantiomers of a wide range of racemates including pharmaceuticals, amino acids, and carbohydrates. CIMS is similar to traditional ion mobility spectrometry, where gas-phase ions, when subjected to a potential gradient, are separated at atmospheric pressure due to differences in their shapes and sizes. In addition to size and shape, CIMS separates ions based on their stereospecific interaction with a chiral gas. In order to achieve chiral discrimination by CIMS, an asymmetric environment was provided by doping the drift gas with a volatile chiral reagent. In this study (S)-(+)-2-butanol was used as a chiral modifier to demonstrate enantiomeric separations of atenolol, serine, methionine, threonine, methyl alpha-glucopyranoside, glucose, penicillamine, valinol, phenylalanine, and tryptophan from their respective racemic mixtures.  相似文献   

20.
In this study, a new design for electrospray ionization ion mobility spectrometry (ESI-IMS) was developed. This design has two important differences in comparison to the present ESI-IMS systems. First, a few centimeters of the cell comprising the electrospray needle was located outside of the oven used for heating the IMS cell. This modification prevents prespray solvent evaporation problems such as needle clogging and disturbance of the electrospray process. Second, in addition to the drift gas, a counterflow of a heated gas (desolvation gas) was used between the counter electrode and the ion gate to speed up the desolvation process (Hill, H. H., Jr. Anal. Chem. 1998, 70, 4929-4938). This modification increased the solvent evaporation and resulted in decreasing the drift time, increasing the peak intensity and increasing the resolving power (RP) or enhancing the resolution for separation of two adjacent ion peaks. In this work, the ion mobility spectra of different compounds including ethion, malathion, metalaxyl, fenamifos, methylamine, triethylamine, tributhylamine, codeine, and morphine were obtained to confirm enhancing of the resolving power of the ion peaks by using the desolvation gas. Furthermore, the method has also been applied to obtain the figures of merit for ethion as a test compound. The linear dynamic range for ethion was in the range 50-1000 microg/L with a limit of quantification of the 50 microg/L.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号