首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Ceramics International》2016,42(15):17023-17031
The characterization of chitosan – hydroxyapatite (CH – HAp) composite sponges prepared via freeze-drying methodology is reported in this study. Stearic acid (SA), added as a surface modifier of the HAp nanoparticles, induced changes in the TG/DTG results, particle size distribution and particle morphology. Composite sponges prepared with SA coated HAp demonstrated enhanced biocompatibility and structural properties, as compared to the composites prepared with uncoated HAp. SA coating modified the morphology of the composite, promoting a better dispersion of HAp particles within the composite sponges, and better homogeneity of the polymeric cover with HAp particles. The viability of the composites for cell culture applications was analyzed, and the results suggest that the sponges are biocompatible. Therefore, SA proved to be a good candidate for surface coating of HAp nanoparticles prevent agglomerations, and could be used effectively in the preparation of biocompatible composite sponges with chitosan.  相似文献   

2.
《Ceramics International》2016,42(8):10085-10093
Over the last few years, a trend in medical applications is to find solutions for metallic implants using coatings that can improve bioactivity and osseointegration. The goal of this study was to obtain and investigate sputtered hydroxyapatite coatings enriched with SiC to enhance the bioactivity and osseointegration of Ti alloys used in orthopaedic applications. The films were characterized in terms of phase composition, roughness, corrosion resistance in a synthetic body fluid (SBF) and in vitro biocompatibility with MG 63 osteoblast-like cells. All of the investigations were conducted using XRD, AFM, cell viability assays and proliferation tests. The results revealed that the addition of SiC had a positive influence on the properties of the sputtered hydroxyapatite. The addition of SiC led to an improvement in coating adhesion and corrosion resistance in an SBF solution over the HAP coating. All of the coatings presented cell viability values over 90%, revealing their suitability for medical applications.  相似文献   

3.
《Ceramics International》2023,49(2):1572-1584
The demand for bone graft substitutes for orthopedics and dentistry is constantly growing due to the increase of ageing-related diseases. Synthetic hydroxyapatite (HA) is largely used as a bone graft material thanks to its biocompatibility, osteointegration, osteoconductive and osteoinductive properties and similarity to biological apatite, the main mineral component of bones and teeth. Biogenic apatite has gained attention due to its peculiar intrinsic characteristics: multi-doped ion composition and micro- and nano-scale architecture make natural-derived HA particularly promising for biomedical applications.At the same time, the growing interest in green materials is pushing towards the use of more sustainable biomaterials precursors, including re-use materials: marine waste, such as mollusk-shells, shellfish carapaces, cuttlefish bone, and fishbone have become widely studied sources of biogenic HA. Indeed, they are rich in calcium carbonate (CaCO3), which can be converted into HA by environmentally sustainable processes. This allows the transformation of waste into valuable materials, while paying attention to the issues of sustainability and circular economy.In this review, we listed and discussed the methods to produce HA starting from shell-derived CaCO3, describing all the steps and synthesis routes proposed for the conversion procedure, with a special focus on the different species of marine shells used. We discussed the use of HA alone or in combination with other materials (natural and synthetic polymers), used to enhance the mechanical and biological properties.We summarized the types of devices obtained by marine-derived HA, including nanorods, particulates and scaffolds and we described their in vitro and in vivo behavior.The up-to-date literature was summarized in tables with a special focus on the in vitro and in vivo biological evaluation of such materials.In conclusion, composite biomaterials based on marine-derived biogenic HA are reported as potential candidates for synthetic bone substitutes highlighting their potential, limitations and future perspectives.  相似文献   

4.
A novel process for the deposition of a hydroxyapatite (HA) coating on a smooth implant surface has been developed. Specimens were firstly subjected to electrodeposition at −1.8 V (versus Ag/AgCl) in a mixed solution of 0.042 M Ca(NO3)2·4H2O and 0.025 M NH4H2PO4 at 85 °C for 5 s, and then post-treated in 1 M NaOH solution for 30 min. The experimental results showed the specimens prepared by the designed process to have better adhesion properties than those prepared by the traditional electrodeposition process.  相似文献   

5.
《Ceramics International》2017,43(12):9105-9109
Plasma spraying is the most commonly used thermal spray method for the application of hydroxyapatite (HA, Ca10(PO4)6(OH)2) coatings. In the present study, the HA coatings were plasma spraying deposited onto plates of titanium pre-heated to 20 °C, 300 °C and 550 °C. The obtained HA coatings were investigated by means of X-ray diffraction and scanning electron microscopy. It is found that the coatings, in addition to HA, contain the tetracalcium phosphate (TTCP, (Ca4(PO4)2O) phase (~10%) and a small amount of CaO (<2%). Crystal structure of HA in the coatings is revealed to be distorted. The PO4 tetrahedrons are deformed (Baur distortion coefficient D1(TO) ~0.2). The distances Ca1-O1 and Ca1-O2 are changed as compared to these in stoichiometric hydroxyapatite. These distortions are considered as a result of internal stresses, which are demonstrated in the broadening of peaks on X-ray diffraction pattern of HA. Microstructure of coatings consisting of flattened splats was formed by fully molten particles. The axial base texture was developed in the coatings. Ultrastructure is columnar with a preferred orientation of c-axes of the crystals parallel to the normal of plane coating n. The heating of substrate has a marked effect on the ultrastructure of coatings: the domain size increases from 790 to 1100 Å, the strain Δ decreases from 1.6·10-3 to 1,2·10–3, TTCP content diminishes from 12% to 7%. These results show that the effects due to heating of the substrate may be associated with partial recovery of HA microstructure.  相似文献   

6.
W.X Chen  L.Y Wang  Z.D Xu 《Carbon》2003,41(2):215-222
Ni-P-carbon nanotube (CNT) composite coating and carbon nanotube/copper matrix composites were prepared by electroless plating and powder metallurgy techniques, respectively. The effects of CNTs on the tribological properties of these composites were evaluated. The results demonstrated that the Ni-P-CNT electroless composite coating exhibited higher wear resistance and lower friction coefficient than Ni-P-SiC and Ni-P-graphite composite coatings. After annealing at 673 K for 2 h, the wear resistance of the Ni-P-CNT composite coating was improved. Carbon nanotube/copper matrix composites revealed a lower wear rate and friction coefficient compared with pure copper, and their wear rates and friction coefficients showed a decreasing trend with increasing volume fraction of CNTs within the range from 0 to 12 vol.% due to the effects of the reinforcement and reduced friction of CNTs. The favorable effects of CNTs on the tribological properties are attributed to improved mechanical properties and unique topological structure of the hollow nanotubes.  相似文献   

7.
Thermoelectric power of carbon fiber reinforced cement composites was firstly enhanced efficiently by metallic oxide microparticles in the cement matrix. The absolute Seebeck coefficient of these composites increased steadily with increasing metallic oxide content and achieved 4–5 folds of the original one. The largest absolute thermoelectric power of +100.28 µV/°C was obtained for the composite with 5.0 wt% Bi2O3 microparticles. The carrier scattering of the interface between oxide microparticles and cement matrix is probably attributed to the Seebeck effect enhancement.  相似文献   

8.
《Ceramics International》2019,45(12):15143-15155
Designing biocompatible superparamagnetic mesoporous nanoparticles for advanced healthcare applications has received much attention. In this research, we have synthesized intrinsic mesoporous superparamagnetic hydroxyapatite (HAp) nanoparticles using bio-waste of black Chlamys varia seashell as a calcium source by sodium dodecyl sulfate (SDS)–enabled microwave-assisted synthesis approach. The synthesized Fe-doped HAp nanoparticles were characterized using various characterization techniques to know the phase purity and morphological features. The incorporation of Fe greatly affected the morphology of HAp nanoparticles without affecting their crystalline phase. Superparamagnetic behavior was observed with the incorporation of Fe in the HAp nanoparticles. Further, saturation magnetization was enhanced with higher incorporation of Fe ions. The cytotoxicity studies of the synthesized pure and Fe-doped HAp samples conducted using a human osteoblasts cell line (MG63), which indicated that Fe-doped HAp nanoparticles are biocompatible. Further, antibacterial activity analysis also confirmed their excellent antibacterial performance against different pathogens. Hence, SDS-enabled microwave-assisted synthesis approach using seashell as a calcium source would be a better approach for the production of intrinsic mesoporous superparamagnetic HAp nanoparticles for various biomedical applications, such as drug targeting, hyperthermia cancer therapy, and magnetic resonance imaging.  相似文献   

9.
Surface functionalization of pure titanium (cp-Ti) with hydroxyapatite (HAp) was successfully achieved by means of electrochemical deposition (ED) in a solution containing calcium nitrate and ammonium dihydrogen phosphate. The aim of this study is to evaluate the influence of the deposition temperature on the elemental and phase composition, chemical bonds, morphology, and in vitro electrochemical behaviour in biological simulated media (simulated body fluid - SBF). The roughness and wettability of the developed coatings are also investigated. By increasing the deposition temperature from 50 °C to 75 °C, the HAp coatings present a well-crystalized structure, denser and a nobler behaviour in terms of electrochemical behaviour in SBF at 37 °C. Also, by increasing the deposition temperature from 50 °C to 75 °C, the contact angle has decreased from 76.1° to 27.4°, exhibiting a highly hydrophilic surface. Taking into consideration all the obtained data, electrodeposition of HAp at 75 °C was found preferable when compared to 50 °C. The characteristics of the HAp coatings can be easily adjusted by optimizing the electrochemical deposition parameters and/or controlling specific features like pH, temperature, or ionic concentration of electrolyte, etc.  相似文献   

10.
The present work is aimed at developing a bioactive, corrosion resistant and anti bacterial nanostructured silver substituted hydroxyapatite/titania (AgHA/TiO2) composite coating in a single step on commercially pure titanium (Cp Ti) by plasma electrolytic processing (PEP) technique. For this purpose 2.5 wt% silver substituted hydroxyapatite (AgHA) nanoparticles were prepared by microwave processing technique and were characterized by X-ray diffraction (XRD), Fourier-transform infrared (FT-IR) spectroscopy and transmission electron microscopy (TEM) methods. The as-synthesized AgHA particles with particle length ranging from 60 to 70 nm and width ranging from 15 to 20 nm were used for the subsequent development of coating on Cp Ti. The PEP treated Cp Ti showed both titania and AgHA in its coating and exhibited an improved corrosion resistance in 7.4 pH simulated body fluid (SBF) and 4.5 pH osteoclast bioresorbable conditions compared to untreated Cp Ti. The in vitro bioactivity test conducted under Kokubo SBF conditions indicated an enhanced apatite forming ability of PEP treated Cp Ti surface compared to that of the untreated Cp Ti. The Kirby-Bauer disc diffusion method or antibiotic sensitivity test conducted with the test organisms of Escherichia coli (E. coli) for 24 h showed a significant zone of inhibition for PEP treated Cp Ti compared to untreated Cp Ti.  相似文献   

11.
《Ceramics International》2015,41(6):7381-7386
The aim of this work was to compare fatigue behavior and oxidation resistance of pitch-derived CC (carbon) composite with CC/ceramic (carbon/ceramic) composites obtained by impregnation of CC composite with polysiloxane-based preceram and their subsequent heat treatment. Two types of CC/ceramic composites were studied; CC/SiCO composite obtained at 1000 °C, and CC/SiC composite obtained at 1700 °C. Both types of composites show much better fatigue mechanical performance in comparison to pure CC composite. CC/SiCO composite had 3 times better fatigue properties, and CC/SiC composite 4.5 times better fatigue properties than the reference CC composite. After a fatigue test composites partially retain their mechanical properties, and normalized residual modulus in the direction perpendicular to laminates exceeds 50% for CC and CC/SiCO composites. In the other directions normalized residual modulus is higher than 80% for all composites. Oxidative tests led at 600 °C in air atmosphere indicated oxidation resistance of CC/SiC composites.  相似文献   

12.
《Ceramics International》2015,41(8):9770-9778
The combination of bioinert and bioactive material offers new potentialities in bone tissue engineering. The present paper deals with preparation of novel biomaterial composite based on silicon nitride (Si3N4) and bioglass (in amount of 10 and 30 wt%) by free sintering at 980 °C for 1 h in nitrogen atmosphere. The obtained material was characterised by differential thermal analysis (DTA) and X-ray powder diffraction (XRD), porosity and pore size distribution were evaluated by means of mercury intrusion porosimetry (MIP). The bioactivity was examined in vitro with respect to the ability of hydroxyapatite layer formation on the surface of materials as a result of contact with simulated body fluid (SBF). All composites were studied by Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM) before and after immersion in SBF. The bioglass-free sample was prepared as a reference material to compare the microstructure and bioactivity to the composites.  相似文献   

13.
《Ceramics International》2017,43(17):14968-14975
The aim of this paper is to prepare the hydroxyapatite by Ion Beam Assisted Deposition and to investigate in terms of its elemental and phase composition, roughness and in vitro corrosion resistance. The coatings were prepared with and without applying bias on substrate, in order to find the effect of bias on the chemical, structural, morphological and anti-corrosive properties. The biased coatings exhibited Ca/P ratio closer to the value of the stoichiometric HAP (1.67). The phase composition is not affected by the bias evolution. The adhesion of both coatings is still satisfactory for biomedical applications, irrespective of the bias. Hydroxyapatite deposited without bias presented the best corrosion resistance in SBF at 37 °C, probably due to its smooth surface and low porosity. Moreover, this coating proved to have the highest protection ability at the SBF corrosive attack.  相似文献   

14.
A series of novel zinc oxide (ZnO) containing bioactive glass compositions in SiO2-Na2O-CaO-P2O5 system and composite with hydroxyapatite (HAp) nano-particles were developed and applied as coating on Ti-6Al-4V substrates. The bioactive glasses and their composites were also processed to yield dense scaffolds, porous scaffolds and porous bone filler materials. The coating materials and the coatings were characterized and evaluated by different in vitro techniques to establish their superior mechanical properties. The cytotoxicity test of the coating material, porous and dense scaffolds and coated specimens showed non-cytotoxicity, biocompatibility and promising in vitro bioactivity for all tested samples. The dissolution behaviour studies of the bioactive glasses and the composites in simulated body fluid showed promising in vitro release pattern and bioactivity for all tested samples. Addition of nanosized HAp improves mechanical properties of the bioactive glass coating without affecting the in vitro bioactivity.  相似文献   

15.
The chemical corrosion and UV–vis absorption and infrared absorption spectra of binary and multicomponent lithium silicate glasses and corresponding glass–ceramics were investigated. The chemical durability of the glasses and derived glass–ceramics was found to be excellent to all leaching media. The IR absorption spectra of the glass and glass–ceramic samples reveal absorption bands of characteristic groups mainly due to major silicate network besides the possible sharing of network units due to some involving oxide constituents. X-ray analysis of glass–ceramics indicates the separation of lithium disilicate phase as the main constituent beside other phases according to the specimen chemical constituents. The obvious promising investigated chemical and physical properties are correlated with the presence of multioxides such as Al2O3, TiO2, MgO and ZrO2. Transmission and reflectivity properties reveal acceptable data. The prepared glass–ceramics are recommended for dental applications.  相似文献   

16.
《Ceramics International》2023,49(15):24885-24894
In this work, PMMA-based composite bone cements, embedding bioactive and ferrimagnetic glass-ceramic particles, have been prepared and characterized. Bioactivity, wettability, density, curing parameters, viscoelastic behaviour, bending strengths and creep have been investigated at 37 °C. The growth of a layer of HA on the samples surface after immersion in SBF has been confirmed. The presence of glass-ceramic particles improved the wetting behaviour of the composite cements. Shorter curing times and lower maximum temperatures for the three composite cements, in comparison to the plain one, have been detected. Almost unaffected mechanical properties of the composite bone cements have been found in comparison to those of the plain commercial cement both at room and at 37 °C. A little increase of the viscous flow has been evidenced in the composite samples at 37 °C. Radiographic imaging confirmed the intrinsic radiopacity of the composite cements.  相似文献   

17.
《Ceramics International》2017,43(9):6858-6867
The aim of the paper is to explore the tribological performance of hydroxyapatite (HA) coatings deposited by radio frequency (RF) magnetron sputtering on AZ31 magnesium alloy (96% Mg, 3% Al, 0.7% Zn, 0.3% Mn) for biomedical applications. In this study, the position of the samples on a substrate holder, relative to a target erosion zone was taken into consideration in order to elucidate its impact on the coating characteristics, such as composition, morphology, surface topography and tribology. Substrate rotation and arc-movement were foreseen in the experimental set-up to increase the uniformity of thin film properties. The deposited HA thin films were revealed to exhibit an increase of the Ca/P ratio from 1.83 to 1.97, a decrease of (002) texture and thickness, as the samples were shifted towards the target erosion zone. By coatings, the roughness of Mg alloy was decreased (Ra Mg alloy=31.3 nm; Ra coating=29 nm and 21 nm). The coating placed in the centre of the substrate holder showed high hardness and Young's modulus (H =8.3±0.9 GPa; E=89±10 GPa) than the coating prepared under the target erosion zone (H =6.9±1.1 GPa; E=75±6 GPa). The coating deposited under target erosion zone exhibits superior friction behaviour in simulated body fluid environment, with the friction coefficient (μ) of 0.184, while the sample located in the centre of the substrate holder possesses the friction coefficient (0.306) comparable to the AZ31 substrate (0.307). The low wear rate was determined in the case of coating deposited under target erosion zone (4.83×10−5 mm3 N−1 m−1) than uncoated AZ31 substrate (0.00518 mm3 N−1 m−1) or than coating placed in the centre of the substrate holder (0.00294 mm3 N−1 m−1).  相似文献   

18.
This study was aimed at investigating the effect of the fluoride content (added as NaF) on the in vitro bioactivity of an experimental calcium silicate-based cement (wTC-Bi) obtained from white Portland cement. To this purpose, wTC-Bi and fluoride-doped wTC-Bi cements (i.e. FTC-Bi and F10TC-Bi with fluoride contents of 1% and 10% w/w, respectively) were aged in Dulbecco's Phosphate Buffered Saline (DPBS) and were comparatively analysed by micro-Raman and IR spectroscopy to investigate the presence of deposits on the surface of the cements and the composition changes of the cement as a function of the storage time. Commercial White ProRoot MTA was analyzed as reference.  相似文献   

19.
《Ceramics International》2016,42(8):9769-9778
In this work, we successfully synthesized the silver-reduced graphene oxide (Ag-rGO) composites based on the in situ growth of Ag nanoparticles (NPs) on the surfaces of the GO sheets through a one-pot solvothermal method without using any surfactants or modifiers. The as-synthesized Ag-rGO composites have been characterized by X-ray diffraction, X-ray photoelectron spectrometry and electron microscopy. Results showed that high-density Ag NPs and dots with uniform size distribution were grown on the surfaces of the GO sheets, accompanied by the reduction of GO to rGO. By simply changing the concentration of Ag+ ions in the solvothermal reaction system, the size and distribution of the Ag nanocrystals could be controlled. The antibacterial properties of the Ag-rGO composites were investigated by combined techniques of inhibition zone method, plate colony-counting method and bacterial growth curve. The Ag-rGO composites have been found to exhibit excellent antibacterial properties with long-term effects, which could effectively inhibit the growth of bacteria of Vibrio natriegens and Bacillus sp. 1NLA3E. The strongly-coupled interaction between the Ag nanocrystals and the rGO supports as well as the presence of the Ag dots contributed equally to the prominent long-term antibacterial performance of the Ag-rGO composites. The present Ag-rGO composites may find important environmental applications.  相似文献   

20.
《Ceramics International》2022,48(22):32712-32722
Nano-infiltration and transient eutectic phase (NITE) SiC matrix composites are designed for application in aerospace propulsion systems, particularly in fasteners and thrusters. A variety of carbon fibers with different properties have been selected as reinforcements for SiC matrix composites. Carbon fibers are known to be stable at high temperatures; however, the effects of high applied pressure at high temperatures on the fiber microstructure evolution and mechanical properties are not well-known. As a scoping study for fabricating NITE C/SiC composites, the behaviors of various carbon fibers in SiC composites. Pitch-based fibers, namely, GRANOX XN-05 and YS-90A, and a polyacrylonitrile-based fiber, namely, TORAYCA T-300B, were selected for matrix reinforcement. The 3-point bending test results indicated pseudo-ductile behaviors in the cases of YS-90A and T-300B fiber reinforcements. Fracture resistance evaluation based on the single-notch bending test indicated that the YS-90A fiber reinforced composite afforded the highest fracture resistance among the three C/SiC composites. The microstructure evolution on YS-90A and T-300B fibers was limited to near the fiber surface. Therefore, YS-90A and T-300B carbon fibers are potential candidates for reinforcement in NITE C/SiC composites.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号