首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
High-resolution x-ray measurements were performed with a von Hamos-type bent crystal spectrometer using for the detection of the diffracted photons either a back-illuminated charge-coupled device (CCD) camera or a front-illuminated one. For each CCD the main x-ray emission lines (e.g., Kalpha, Kbeta, Lalpha, and Lbeta) of a variety of elements were measured in order to probe the performances of the two detectors between 1 and 18 keV. From the observed x-ray lines the linearity of the energy response, the noise level, the energy resolution, and the quantum efficiency ratio of the two CCDs were determined.  相似文献   

2.
We show that an x-ray charge coupled device (CCD) may be used as a particle detector for atomic and molecular mega-electron-volt (MeV) projectiles of around a few hundred keV per atomic mass unit. For atomic species, spectroscopic properties in kinetic energy measurements (i.e., linearity and energy resolution) are found to be close to those currently obtained with implanted or surface barrier silicon particle detectors. For molecular species, in order to increase the maximum kinetic energy detection limit, we propose to put a thin foil in front of the CCD. This foil breaks up the molecules into atoms and spreads the charges over many CCD pixels and therefore avoiding saturation effects. This opens new perspectives in high velocity molecular dissociation studies with accelerator facilities.  相似文献   

3.
X-ray line spectra ranging from 17 to 77 keV were quantitatively measured with a Laue spectrometer, composed of a cylindrically curved crystal and a detector. Either a visible CCD detector coupled with a CsI phosphor screen or an imaging plate can be chosen, depending on the signal intensities and exposure times. The absolute sensitivity of the spectrometer system was calibrated using pre-characterized laser-produced x-ray sources and radioisotopes. The integrated reflectivity for the crystal is in good agreement with predictions by an open code for x-ray diffraction. The energy transfer efficiency from incident laser beams to hot electrons, as the energy transfer agency for specific x-ray line emissions, is derived as a consequence of this work.  相似文献   

4.
The static x-ray imager at the National Ignition Facility is a pinhole camera using a CCD detector to obtain images of Hohlraum wall x-ray drive illumination patterns seen through the laser entrance hole (LEH). Carefully chosen filters, combined with the CCD response, allow recording images in the x-ray range of 3-5 keV with 60?μm spatial resolution. The routines used to obtain the apparent size of the backlit LEH and the location and intensity of beam spots are discussed and compared to predictions. A new soft x-ray channel centered at 870 eV (near the x-ray peak of a 300 eV temperature ignition Hohlraum) is discussed.  相似文献   

5.
Originally conceived and developed at the European Synchrotron Radiation Facility (ESRF) as an "area" detector for rapid x-ray imaging studies, the fast readout low noise (FReLoN) detector of the ESRF [J.-C. Labiche, ESRF Newsletter 25, 41 (1996)] has been demonstrated to be a highly versatile and unique detector. Charge coupled device (CCD) cameras at present available on the public market offer either a high dynamic range or a high readout speed. A compromise between signal dynamic range and readout speed is always sought. The parameters of the commercial cameras can sometimes be tuned, in order to better fulfill the needs of specific experiments, but in general these cameras have a poor duty cycle (i.e., the signal integration time is much smaller than the readout time). In order to address scientific problems such as time resolved experiments at the ESRF, a FReLoN camera has been developed by the Instrument Support Group at ESRF. This camera is a low noise CCD camera that combines high dynamic range, high readout speed, accuracy, and improved duty cycle in a single image. In this paper, we show its application in a quasi-one-dimensional sense to dynamic problems in materials science, catalysis, and chemistry that require data acquisition on a time scale of milliseconds or a few tens of milliseconds. It is demonstrated that in this mode the FReLoN can be applied equally to the investigation of rapid changes in long range order (via diffraction) and local order (via energy dispersive extended x-ray absorption fine structure) and in situations of x-ray hardness and flux beyond the capacity of other detectors.  相似文献   

6.
An extremely high resolution flat field type slit less soft x-ray emission spectrometer has been designed and constructed for the long undulator beamline BL07LSU in SPring-8. By optimizing the ruling parameters of two cylindrical gratings, a high energy resolution ΔE < 100 meV and/or an E∕ΔE ~ 10 000 are expected for the energy range of 350 eV - 750 eV taking into account the broadening by the spatial resolution (25 μm) of a CCD detector. A coma-free operation mode proposed by Strocov et al., is also applied to eliminate both defocus and coma aberrations. The spectrometer demonstrated experimentally that E/ΔE = 10 050 and 8046 for N 1s (402.1 eV) and Mn 2p (641.8 eV) edges, respectively.  相似文献   

7.
A novel fabrication method for soft x-ray transmission grating and other optical elements is presented. The method uses focused-ion-beam technology to fabricate high-quality free standing grating bars on transmission electron microscopy grids. High quality transmission gratings are obtained with superb accuracy and versatility. Using these gratings and back-illuminated CCD camera, absolutely calibrated x-ray spectra can be acquired for soft x-ray source diagnostics in the 100-3000 eV spectral range. Double grating combinations of identical or different parameters are easily fabricated, allowing advanced one-shot application of transmission grating spectroscopy. These applications include spectroscopy with different spectral resolutions, bandwidths, dynamic ranges, and may serve for identification of high-order contribution, and spectral calibrations of various x-ray optical elements.  相似文献   

8.
We present a data acquisition system to perform on-the-fly background subtraction and lower-level discrimination compression of streaming x-ray photon correlation spectroscopy data from a fast charge-coupled device (CCD) area detector. The system is built using a commercial frame grabber with an on-board field-programmable gate array. The system is capable of continuously processing at least 60 CCD frames per second each consisting of 1024 × 1024 16-bit pixels with ? 15,000 photon hits per frame at a maximum compression factor of ≈95%.  相似文献   

9.
The topic of this work is the study of direct detection of electrons by Charge-Coupled-Devices (CCD). The aim is to design a detector for the angle and energy-selective detection of signal electrons in very low energy scanning electron microscopy (VLESEM), using an electron-bombarded CCD sensor (EBCCD). We concentrate upon two problems—the design of appropriate electronics and determination of an appropriate energy of the signal electrons for the CCD sensor.  相似文献   

10.
Measurement of x-ray emission is an important parameter to investigate runaway behavior of fast electrons produced in nanosecond-pulse gas discharge. An online detection system of x rays is described in this paper, and the system consists of an x-ray detector with NaI (Tl) scintillator and photomultiplier tube, and an integrated multichannel analyzer. The system is responsible for detecting x-ray emission signal, processing the detected signals, and scaling the energy distribution. The calibration results show that every channel of the detection system represents a given x-ray energy and various x rays can be divided into different energy ranges between 10 and 130 keV. For a repetitive nanosecond-pulse breakdown between highly nonuniform gaps in open air, an energy distribution is obtained using the online detection system. It shows that the x-ray emission is a continuous spectrum and the x rays of above 60 keV dominate in the detected energy distribution.  相似文献   

11.
In this paper, we report a method of precise and fast absolute x-ray energy calibration over a wide energy range using an iterative x-ray diffraction based method. Although accurate x-ray energy calibration is indispensable for x-ray energy-sensitive scattering and diffraction experiments, there is still a lack of effective methods to precisely calibrate energy over a wide range, especially when normal transmission monitoring is not an option and complicated micro-focusing optics are fixed in place. It is found that by using an iterative algorithm the x-ray energy is only tied to the relative offset of sample-to-detector distance, which can be readily varied with high precision of the order of 10(-5) -10(-6) spatial resolution using gauge blocks. Even starting with arbitrary initial values of 0.1 A?, 0.3 A?, and 0.4 A?, the iteration process converges to a value within 3.5 eV for 31.122 keV x-rays after three iterations. Different common diffraction standards CeO(2), Au, and Si show an energy deviation of 14 eV. As an application, the proposed method has been applied to determine the energy-sensitive first sharp diffraction peak of network forming GeO(2) glass at high pressure, exhibiting a distinct behavior in the pressure range of 2-4 GPa. Another application presented is pair distribution function measurement using calibrated high-energy x-rays at 82.273 keV. Unlike the traditional x-ray absorption-based calibration method, the proposed approach does not rely on any edges of specific elements, and is applicable to the hard x-ray region where no appropriate absorption edge is available.  相似文献   

12.
数字CCD相机光电输入输出响应不均匀特性是其用于光束远近场能量分布测量的重要参数,因此研究数字CCD相机的响应不均匀性,是保障激光参数测量系统测量精度的关键技术环节。从理论上分析了数字CCD相机光电响应不均匀性的原因,通过建立数字CCD相机响应不均匀性测试系统和三维模型,推导出了数字CCD相机相应不均匀性的计算公式,对数字CCD相机的响应不均匀性进行测量与分析,给出了测试系统的结构框图和部分测试结果。  相似文献   

13.
The designs of a compact, fast CCD (cFCCD) camera, together with a resonant soft x-ray scattering endstation, are presented. The cFCCD camera consists of a highly parallel, custom, thick, high-resistivity CCD, readout by a custom 16-channel application specific integrated circuit to reach the maximum readout rate of 200 frames per second. The camera is mounted on a virtual-axis flip stage inside the RSXS chamber. When this flip stage is coupled to a differentially pumped rotary seal, the detector assembly can rotate about 100°/360° in the vertical/horizontal scattering planes. With a six-degrees-of-freedom cryogenic sample goniometer, this endstation has the capability to detect the superlattice reflections from the electronic orderings showing up in the lower hemisphere. The complete system has been tested at the Advanced Light Source, Lawrence Berkeley National Laboratory, and has been used in multiple experiments at the Linac Coherent Light Source, SLAC National Accelerator Laboratory.  相似文献   

14.
Total-reflection mirror optics for high-energy x-ray microfocusing have been developed, and tested in the energy range of 30-100 keV at beamline 20XU of Synchrotron Radiation Facility SPring-8. The optical system consists of a Kirkpatrick-Baez-type [J. Opt. Soc. Am. 38, 766 (1548)] focusing optics with aspherical total-reflection mirrors for the purpose of reducing the spherical aberrations. A focused beam size of 0.35 x 0.4 microm(2) has been achieved at an x-ray energy of 80 keV, and the measured spot size was less than 1 microm in the x-ray energy region below 90 keV.  相似文献   

15.
The runaway electrons have been measured by hard x-ray detectors and soft x-ray array in the J-TEXT tokamak. The hard x-ray radiations in the energy ranges of 0.5-5 MeV are measured by two NaI detectors. The flux of lost runaway electrons can be obtained routinely. The soft x-ray array diagnostics are used to monitor the runaway beam generated in disruptions since the soft x-ray is dominated by the interaction between runaway electrons and metallic impurities inside the plasma. With the aid of soft x-ray array, runaway electron beam has been detected directly during the formation of runaway current plateau following the disruptions.  相似文献   

16.
A complete in-vacuum curved-crystal x-ray emission spectrometer in Johansson geometry has been constructed for a 2-6 keV energy range with sub natural line-width energy resolution. The spectrometer is designed to measure x-ray emission induced by photon and charged particle impact on solid and gaseous targets. It works with a relatively large x-ray source placed inside the Rowland circle and employs position sensitive detection of diffracted x-rays. Its compact modular design enables fast and easy installation at a synchrotron or particle accelerator beamline. The paper presents main characteristics of the spectrometer and illustrates its capabilities by showing few selected experimental examples.  相似文献   

17.
The soft x-ray materials science instrument is the second operational beamline at the linac coherent light source x-ray free electron laser. The instrument operates with a photon energy range of 480-2000 eV and features a grating monochromator as well as bendable refocusing mirrors. A broad range of experimental stations may be installed to study diverse scientific topics such as: ultrafast chemistry, surface science, highly correlated electron systems, matter under extreme conditions, and laboratory astrophysics. Preliminary commissioning results are presented including the first soft x-ray single-shot energy spectrum from a free electron laser.  相似文献   

18.
Newbury DE 《Scanning》2000,22(6):345-351
Characteristic x-ray production with energetic electrons depends strongly on the overvoltage, the ratio of the incident beam energy to the critical excitation energy for the atomic species of interest. Low-voltage x-ray microanalysis (beam energy < or = 5 keV) is especially susceptible to artifacts due to sample charging because the overvoltage is low and even slight charging can strongly affect peak intensities. The Duane-Hunt bremsstrahlung limit is a good diagnostic to detect sample charging. Dynamic charging effects, however, can influence spectra despite an apparently satisfactory Duane-Hunt limit. Dynamic charging effects must be examined by time series experiments, or through use of dynamic energy windows continuously measuring count rates placed across the spectrum. When charging is a problem, conductive surface coatings can eliminate the effects. When pristine surfaces must be examined without coating, the use of a conductive grid can control charging so that useful x-ray spectra can be obtained.  相似文献   

19.
Lithium's high x-ray transparency makes it an attractive material for windows intended to protect soft x-ray diagnostics in high energy density experiments. Pure lithium is soft and weak, but lithium mixed with lithium hydride powder becomes harder and stronger, in principle without any additional x-ray absorption. A comparison with the standard material for x-ray windows, beryllium, suggests that lithium or lithium strengthened by lithium hydride may well be an excellent option for such windows.  相似文献   

20.
High performance electron cyclotron resonance (ECR) ion sources, such as VENUS (Versatile ECR for NUclear Science), produce large amounts of x-rays. By studying their energy spectra, conclusions can be drawn about the electron heating process and the electron confinement. In addition, the bremsstrahlung from the plasma chamber is partly absorbed by the cold mass of the superconducting magnet, adding an extra heat load to the cryostat. Germanium or NaI detectors are generally used for x-ray measurements. Due to the high x-ray flux from the source, the experimental setup to measure bremsstrahlung spectra from ECR ion sources is somewhat different from that for the traditional nuclear physics measurements these detectors are generally used for. In particular, the collimation and background shielding can be problematic. In this paper, we will discuss the experimental setup for such a measurement, the energy calibration and background reduction, the shielding of the detector, and collimation of the x-ray flux. We will present x-ray energy spectra and cryostat heating rates depending on various ion source parameters, such as confinement fields, minimum B-field, rf power, and heating frequency.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号