1.
A microfabricated microfluidic device coupled with a nanospray tip for electrospray ionization of dilute solutions is described. The device has been interfaced with a time-of-flight mass spectrometer and evaluated for sensitive, high-speed detection of peptides and proteins. The electrospray voltage was applied through the microchip to the nanospray capillary that was attached at the end of a microfabricated channel. Fluid delivery rates were 20-30 nL min(-)(1) through the hybridized structure without any pressure assistance. On-line microchip electrophoresis has been demonstrated and the effect of the capillary-chip junction on band broadening examined. Full mass spectra are acquired within 10-20 ms at 50-100 spectra s(-)(1) storage rates. Detection of subattomole levels of sample from a 100 nM solution is demonstrated for infusion experiments.  相似文献   

2.
A novel microfabricated device was implemented for facile coupling of capillary electrophoresis with mass spectrometry (CE/MS). The device was constructed from glass wafers using standard photolithographic/wet chemical etching methods. The design integrated (a) sample inlet ports, (b) the separation channel, (c) a liquid junction, and (d) a guiding channel for the insertion of the electrospray capillary, which was enclosed in a miniaturized subatmospheric electrospray chamber of an ion trap MS. The replaceable electrospray capillary was precisely aligned with the exit of the separation channel by a microfabricated guiding channel. No glue was necessary to seal the electrospray capillary. This design allowed simple and fast replacement of either the microdevice or the electrospray capillary. The performance of the device was tested for CE/MS of peptides, proteins, and protein tryptic digests. On-line tandem mass spectrometry was used for the structure identification of the protein digest products. High-efficiency/high-resolution separations could be obtained on a longer channel (11 cm on-chip) microdevice, and fast separations (under 50 s) were achieved with a short (4.5 cm on-chip) separation channel. In the experiments, both electrokinetic and pressure injections were used. The separation efficiency was comparable to that obtained from conventional capillary electrophoresis.  相似文献   

3.
A novel microfabricated nozzle has been developed for the electrospray of liquids from microfluidic devices for analysis by mass spectrometry. The electrospray device was fabricated from a monolithic silicon substrate using deep reactive ion etching and other standard semiconductor techniques to etch nozzles from the planar surface of a silicon wafer. A channel extends through the wafer from the tip of the nozzle to a reservoir etched into the opposite planar surface of the wafer. Nozzle diameters as small as 15 microm have been fabricated using this method. The microfabricated electrospray device provides a reproducible, controllable, and robust means of producing nano-electrospray of a liquid sample. The electrospray device was interfaced to an atmospheric pressure ionization time-of-flight mass spectrometer using continuous infusion of test compounds at low nanoliter-per-minute flow rates. Nozzle-to-nozzle signal intensity reproducibility using 10 nozzles was demonstrated to be 12% with single-nozzle signal stability routinely less than 4% relative standard deviation (RSD). Solvent compositions have been electrosprayed ranging from 100% organic to 100% aqueous. The signal-to-noise ratio from the infusion of a 10 nM cytochrome c solution in 100% water at 100 nL/min was 450:1. Microchip electrospray nozzles were compared with pulled capillaries for overall sensitivity and signal stability for small and large molecules. The microchip electrospray nozzles showed a 1.5-3-times increase in sensitivity compared with that from a pulled capillary, and signal stability with the microchip was 2-4% RSD compared with 4-10% with a pulled capillary. Electrospray device lifetimes achieved thus far have exceeded 8 h of continuous operation and should be sufficient for typical microfluidic applications. The total volume of the electrospray device is less than 25 pL, making it suitable for combination with microfluidic separation devices.  相似文献   

4.
A 16-channel microfluidic chip with an integrated contact conductivity sensor array is presented. The microfluidic network consisted of 16 separation channels that were hot-embossed into polycarbonate (PC) using a high-precision micromilled metal master. All channels were 40 microm deep and 60 microm wide with an effective separation length of 40 mm. A gold (Au) sensor array was lithographically patterned onto a PC cover plate and assembled to the fluidic chip via thermal bonding in such a way that a pair of Au microelectrodes (60 microm wide with a 5 microm spacing) was incorporated into each of the 16 channels and served as independent contact conductivity detectors. The spacing between the corresponding fluidic reservoirs for each separation channel was set to 9 mm, which allowed for loading samples and buffers to all 40 reservoirs situated on the microchip in only five pipetting steps using an 8-channel pipettor. A printed circuit board (PCB) with platinum (Pt) wires was used to distribute the electrophoresis high-voltage to all reservoirs situated on the fluidic chip. Another PCB was used for collecting the conductivity signals from the patterned Au microelectrodes. The device performance was evaluated using microchip capillary zone electrophoresis (mu-CZE) of amino acid, peptide, and protein mixtures as well as oligonucleotides that were separated via microchip capillary electrochromatography (mu-CEC). The separations were performed with an electric field (E) of 90 V/cm and were completed in less than 4 min in all cases. The conductivity detection was carried out using a bipolar pulse voltage waveform with a pulse amplitude of +/-0.6 V and a frequency of 6.0 kHz. The conductivity sensor array concentration limit of detection (SNR = 3) was determined to be 7.1 microM for alanine. The separation efficiency was found to be 6.4 x 10(4), 2.0 x 10(3), 4.8 x 10(3), and 3.4 x 10(2) plates for the mu-CEC of the oligonucleotides and mu-CZE of the amino acids, peptides, and proteins, respectively, with an average channel-to-channel migration time reproducibility of 2.8%. The average resolution obtained for mu-CEC of the oligonucleotides and mu-CZE of the amino acids, peptides, and proteins was 4.6, 1.0, 0.9, and 1.0, respectively. To the best of our knowledge, this report is the first to describe a multichannel microchip electrophoresis device with integrated contact conductivity sensor array.  相似文献   

5.
A microfabricated fluidic device that combines micellar electrokinetic chromatography and high-speed open-channel electrophoresis on a single structure for the rapid automated two-dimensional analysis of peptides has been devised and demonstrated. The microchip operates by rapidly sampling and analyzing effluent in the second dimension from the first dimension. Second-dimension analyses are performed and completed every few seconds, with total analysis times of less than 10 min for tryptic peptides. The peak capacity of the two-dimensional separations has been estimated to be in the 500-1000 range. The orthogonality of the separation techniques, an important factor for maximizing peak capacity or resolution elements, was verified by examining each technique independently for peptide separations. The two-dimensional separation strategy was found to greatly increase the resolving power over that obtained for either dimension alone.  相似文献   

6.
We have demonstrated the use of a simple microfabricated electrospray ionization source for coupling microfluidic chips to mass spectrometry (MS). A polymer-based microchip, coupled to a triple quadrupole mass spectrometer, has been employed for direct infusion quantitative bioanalysis of methylphenidate (Ritalin) extracted from human urine samples. The approach used a microfabricated polymer electrospray emitter to couple a microfluidic channel to a stable electrospray ionization source. The microchip was fabricated from cycloolefin plastic plate by hot embossing and thermal bonding. This microfluidic chip contained two independent microfluidic channels, integrated with two corresponding electrospray emitters and an internal gold electrode. Liquid-liquid extraction was used to prepare urine samples, spiked with methylphenidate. A trideuterated analogue of methylphenidate (methylphenidate-d(3)) was used as the internal standard for the analysis. The system showed good electrospray stability and reproducibility with different spray tips. Four different electrospray tips were used to analyze the same sample, and the results showed very small variation with a relative standard deviation of 1.4%. A standard curve prepared for methylphenidate in urine (R(2) = 0.999) was linear over the range of 0.4-800 ng/mL. The precision of the quality control samples for three different concentrations ranged from 19.1% at 20 ng/mL, 3.2% at 200 ng/mL, to 3.5% at 667 ng/mL while the accuracy was 96.3% at 20 ng/mL, 101.2% at 200 ng/mL, and 101.6% at 667 ng/mL. No system carryover was detected even when the same device was used for sequential analysis. These results suggest the potential of this microdevice for MS-based quantitative analysis in drug discovery and development.  相似文献   

7.
A novel, rugged capillary electrophoresis-electrospray ionization (CE-ESI) interface where the separation column, an electrical porous junction, and the spray tip are integrated on a single piece of a fused-silica capillary is described. ESI is accomplished by applying an electrical potential through an easily prepared porous junction across a 3-4-mm length of fused silica. A stable electrospray is produced at nanoflow rates generated in the capillary by electrophoretic and electroosmotic forces. The interface is particularly well suited for the detection of low-femtomole levels of proteins and peptides. The ruggedness of this interface was evident by the continuous operation of the same column for over a 2-week period with no detectable deterioration in separation or electrospray performance. The new interface was used for the LC-ESI-MS separation and analysis of peptides and proteins. Injection of 25 fmol of [Glu1]-fibrinopeptide B using the new device produced a CE-ESI-MS electropherogram with a signal-to-noise ratio of over 100 for this peptide.  相似文献   

8.
The coupling of microfabricated devices to nanoelectrospray mass spectrometers using both a triple quadrupole and a quadrupole time-of-flight mass spectrometer (QqTOF MS) is presented for the analysis of trace-level membrane proteins. Short disposable nanoelectrospray emitters were directly coupled to the chip device via a low dead volume connection. The analytical performance of this integrated device in terms of sensitivity and reproducibility was evaluated for standard peptide mixtures. A concentration detection limit ranging from 3.2 to 43.5 nM for different peptides was achieved in selected ion monitoring, thus representing a 10-fold improvement in sensitivity compared to that of microelectrospray using the same chip/mass spectrometer. Replicate injections indicated that reproducibility of migration time was typically less than 3.1% RSD whereas RSD values of 6-13% were observed on peak areas. Although complete resolution of individual components is not typically achieved for complex digests, the present chip capillary electrophoresis (chip-CE) device enabled proper sample cleanup and partial separation of multicomponent samples prior to mass spectral identification. Analyses of protein digests were typically achieved in less than 1.5 min with peak widths of 1.8-2.5 s (half-height definition) as indicated from individual reconstructed ion electropherograms. The application of this chip-CE/QqTOF MS system is further demonstrated for the identification of membrane proteins which form a subset of the Haemophilus influenzae proteome. Bands first separated by 1D-gel electrophoresis were excised and digested, and extracted tryptic peptides were loaded on the chip without any further sample cleanup or on-line adsorption preconcentration. Accurate molecular mass determination (< 5 ppm) in peptide-mapping experiments was obtained by introducing an internal standard via a postseparation channel. The analytical potential of this integrated device for the identification of trace-level proteins from different strains of H. influenzae is demonstrated using both peptide mass-fingerprint database searching and on-line tandem mass spectrometry.  相似文献   

9.
A microfabricated glass chip containing fluidic channels filled with polymer monolith has been developed for reversed-phase electrochromatography. Acrylate-based porous polymer monoliths were cast in the channels by photopolymerization to serve as a robust and uniform stationary phase. UV light-initiated polymerization allows for patterning of polymer stationary phase in the microchip, analogous to photolithography, using a mask and a UV lamp for optimal design of injection, separation, and detection manifolds. The monoliths are cast in situ in less than 10 min, are very reproducible with respect to separation characteristics, and allow easy manipulation of separation parameters such as charge, hydrophobicity, and pore size. Moreover, the solvent used to cast the polymer enables electroosmotic flow, allowing the separation channel to be conditioned without need for high-pressure pumps. The microchip was used for separation of bioactive peptides and amino acids labeled with a fluorogenic dye (naphthalene-2,3-dicarboxaldehyde) followed by laser-induced fluorescence detection using a Kr+ ion laser. The microchip-based separations were fast (six peptides in 45 s), efficient (up to 600,000 plates/m), and outperformed the capillary-based separations in both speed and efficiency. We have also developed a method for complete removal of polymer from the channels by thermal incineration to regenerate the glass chips.  相似文献   

10.
Delivery of proteins and peptides to electrospray ionization mass spectrometers (ESI-MS) has been demonstrated using glass and quartz microfabricated devices. This paper reports the construction and use of poly(dimethylsiloxane) (PDMS) microfabricated soft polymer devices with mass spectrometry for protein analysis. The PDMS devices were fabricated using replica molding against a patterned photoresist generated by photolithographic techniques. The PDMS devices were connected to the mass spectrometer via a derivatized transfer capillary and samples were transferred by electroosmotic pumping. The formulation of PDMS was optimized for compatibility with ESI, and the devices were tested for performance. The practical application of PDMS devices was demonstrated by the identification of rat serum albumin separated by 2-D gel electrophoresis. Extended contact of the sample with the surface of the PDMS device did not significantly affect the sample analysis, and the limit of detection for samples run on a PDMS device was comparable to the limit of detection achieved on glass devices. This study suggests that PDMS devices fabricated using replica molding are compatible with ESI-MS. This will potentially lead to the construction of inexpensive microfabricated devices with complex designs and advanced functionalities.  相似文献   

11.
A monolithic capillary electrophoresis system with integrated on-chip fluorescence detector has been microfabricated on a silicon substrate. Photodiodes in the silicon substrate measure fluorescence emitted from eluting molecules. The device incorporates an on-chip thin-film interference filter that prevents excitation light from inhibiting the fluorescence detection. A transparent AZO conducting ground plane is also used to prevent the high electric fields used for the separation from interfering with the photodiode response. Separations of DNA restriction fragments have been performed in these devices with femtogram detection limits using SYBR Green I intercalating dye.  相似文献   

12.
A miniaturized ion sprayer device is described which is suitable for coupling with chip-based analytical separation devices, multiwell plates, or surfaces containing residues of prepared samples. Two versions of a similar device are described. A "microsprayer" device suitable for coupling to the terminal edge of a capillary electrophoresis (CE) chip is constructed from modified 1/16-in. HPLC fittings. This microsprayer employs a free-standing liquid junction formed via continuous delivery of a flow (2-6 microL/min) of suitable solvent which carries the CE effluent through a pneumatically assisted electrospray (ion spray) needle positioned in front of an atmospheric pressure ionization (API) mass spectrometer. A related but larger "minisprayer" device is also described which employs the same features as the microsprayer, but with an extended sampling capillary tube which can reach into the depths of 96-, 384-, and 1536-multiwell plates containing either sample solutions or dried sample residues. The minisprayer may be positioned in front of an API ion sampling orifice and the multiwell plate positioned stepwise from sample to sample for analysis of trace samples contained in the wells. The resulting infusion-ion spray mass spectrometric analyses can provide sequential analysis of previously prepared biological samples containing small drug compounds, proteins, and related compounds. This same device is also shown to be useful for sampling from a surface containing trace level compounds of biological interest. Results are shown that demonstrate microscale separations and selected ion monitoring (SIM) capillary electrophoresis/mass spectrometry (CE/MS) detection of berberine and palmatine using the microsprayer. SIM ion spray determination of a 2 ng/microL solution of berberine contained as a dry residue in the bottom of a 384-well plate as well as full-scan electrospray mass spectra for low-picomole levels of cytochrome c contained in a 1536-well microtiter plate are shown. The respective micro- and minisprayer devices provide a simple yet effective means of transferring trace-level samples either from a microscale or chip-based separation device as well as samples contained in multiwell plates which are increasingly employed in high-throughput applications in the pharmaceutical industry.  相似文献   

13.
Rapid protein digestion and analysis using a hybrid microchip nanoelectrospray device and time-of-flight mass spectrometry detection are reported. The device consists of a planar glass chip with microfabricated channels coupled to a disposable nanospray emitter. Reactions between substrate and enzyme (trypsin), mixed off-chip and then immediately loaded into a sample reservoir on the device, are monitored in real time following the onset of electrospray. Protein cleavage products are determined at the optimum pH for generating tryptic fragments, directly from the digestion buffer using "wrong-way-round" electrospray, i.e., monitoring (MH)+ ions from basic solutions. Intense tryptic peptide ions are observed within a few minutes following sample loading on the microchip. Proteins were identified from low femtomole or even attomole quantities of analyte/spectrum using peptide mass fingerprinting, loading 0.1-2 pmol/microL of sample on the chip. The sequence coverage for analyzed proteins ranged from 70 to 95%. The rapid analysis of human hemoglobin is demonstrated using the technique.  相似文献   

14.
Stochastic PCR amplification of single DNA template molecules followed by capillary electrophoretic (CE) analysis of the products is demonstrated in an integrated microfluidic device. The microdevice consists of submicroliter PCR chambers etched into a glass substrate that are directly connected to a microfabricated CE system. Valves and hydrophobic vents provide controlled and sensorless loading of the 280-nL PCR chambers; the low volume reactor, the low thermal mass, and the use of thin-film heaters permit cycle times as fast as 30 s. The amplified product, labeled with an intercalating fluorescent dye, is directly injected into the gel-filled capillary channel for electrophoretic analysis. Repetitive PCR analyses at the single DNA template molecule level exhibit quantized product peak areas; a histogram of the normalized peak areas reveals clusters of events caused by 0, 1, 2, and 3 viable template copies in the reactor and these event clusters are shown to fit a Poisson distribution. This device demonstrates the most sensitive PCR possible in a microfabricated device. The detection of single DNA molecules will also facilitate single-cell and single-molecule studies to expose the genetic variation underlying ensemble sequence and expression averages.  相似文献   

15.
Microdialysis sampling is a technique that has been used for in vivo and in vitro monitoring of compounds of pharmaceutical, biomedical, and environmental interest. The coupling of a commercially available microdialysis probe to a microchip-based capillary electrophoresis (CE) system is described. A continuously flowing dialysate stream from a microdialysis probe was introduced into the microchip, and discrete injections were achieved using a valveless gating approach. The effect of the applied voltage and microdialysis flow rate on device performance was investigated. It was found that the peak area varied linearly with the applied voltage. Higher voltages led to lower peak response but faster separations. Perfusion flow rates of 0.8 and 1.0 microL/min were found to provide optimal performance. The on-line microdialysis/microchip CE system was used to monitor the hydrolysis of fluorescein mono-beta-d-galactopyranoside (FMG) by beta-d-galactosidase. A decrease of the FMG substrate with an increase in the fluorescein product was observed. The temporal resolution of the device, which is dependent on the CE separation time, was 30 s. To the best of our knowledge, this is the first reported coupling of a microdialysis sampling probe to a microchip capillary electrophoresis device.  相似文献   

16.
This report describes the development of a compact and versatile, micromachined chip device enabling the efficient coupling of capillary electrophoresis to electrospray mass spectrometry (CE-ESMS). On-chip separation provides a convenient means of achieving rapid sample cleanup and resolution of multicomponent samples (typically 2-5 min) prior to mass spectral analysis. A low dead volume connection facilitating the coupling of microfabricated devices to CE-ESMS was evaluated using two different interfaces. The first configuration used disposable nanoelectrospray emitters directly coupled to the chip device via this low dead volume junction, thereby providing rapid separation of complex protein digests. The performance of this interface was compared with that of more traditional configurations using a sheath flow CE-ESMS arrangement where a fused-silica capillary of varying length enabled further temporal resolution of the multicomponent samples. The sensitivity and analytical characteristics of these interfaces were investigated in both negative and positive ion modes using standard peptide mixtures. The separation performance for synthetic peptides using a chip coated with amine reagent ranged from 26,000 to 58,000 theoretical plates for a sheath flow CE-ESMS interface comprising a 15-cm CE column. Replicate injections of a dilution series of peptide standards provided detection limits of 45-400 nM without the use of on-line preconcentration devices. The reproducibility of migration time ranged from 0.9 to 1.5% RSD whereas RSDs of 5-10% were observed on peak areas. The application of these devices for the analysis of protein digests was further evaluated using on-line tandem mass spectrometry.  相似文献   

17.
Hilmi A  Luong JH 《Analytical chemistry》2000,72(19):4677-4682
Microfabricated capillary electrophoresis (CE) chips with integrated electrochemical detection have been developed on glass substrates. An electroless deposition procedure was used to deposit a gold film directly onto the capillary outlet to provide high-sensitivity electrochemical detection for catechol and several nitroaromatic explosives. Scanning electron microscopy revealed that the electroless gold film contains nanoscopic gold aggregates (100-150 nm) with an average thickness of 79 nm. The electroless deposition procedure can be easily and routinely performed in any wet-chemistry laboratory, and electroless gold can be deposited onto complex and internal surfaces. Intimate coupling of electrochemical detection and CE chips obviates the need for a coupling mechanism or tedious alignment procedures. With nitroaromatic compounds as a working model, microchip capillary electrophoresis equipped with electroless gold has proven to provide high sensitivity and fast response times for sensor applications. The CE microchip system was capable of separation and determination of explosive compounds including TNT in less than 130 s with detection limits ranging from 24 to 36 microg/L, i.e., 4-fold enhancements in detection efficiency in comparison to thick-film technology.  相似文献   

18.
Fluorescently labeled proteins were electrophoretically concentrated on microfabricated devices prior to separation and laser-induced fluorescence detection on the same device. The proteins were concentrated using a porous silica membrane between adjacent microchannels that allowed the passage of buffer ions but excluded larger migrating molecules. Concentrated analytes were then injected into the separation column for analysis. Two basic microchip designs were tested that allowed sample concentration either directly in the sample injector loop or within the microchannel leading from the sample reservoir to the injector. Signal enhancements of approximately 600-fold were achieved by on-chip preconcentration followed by SDS-CGE separation. Preconcentration for CE analysis in both coated and uncoated open channels was also demonstrated. Fluorescently labeled ovalbumin could be detected at initial concentrations as low as 100 fM by using a combination of field-amplified injection and preconcentration at a membrane prior to CE in coated channels.  相似文献   

19.
Desorption electrospray ionization in a small pressure-tight enclosure   总被引:1,自引:0,他引:1  
Venter A  Cooks RG 《Analytical chemistry》2007,79(16):6398-6403
Desorption electrospray ionization (DESI) is made easier to implement, more robust, and exposure of the analyst to the sample is reduced by a novel DESI interface. This features a small, pressure-tight enclosure with fixed spatial relationships between the sprayer, surface, and sampling capillary. There is no loss in signal using this configuration, which provides improved safety and ease of use. Performance is largely independent of the geometrical configuration of the spray and inlet. Enclosed DESI sources with the incident and collection capillaries set at various angles were compared to the conventional optimized geometry open DESI source. Comparable results were obtained in all cases for typical proteins, peptides, and small molecules. With the spray and collection capillaries set parallel and at an angle perpendicular to the surface, the new DESI source allows for easy and direct analysis of the contents of standard 96-well plates. The effects of various operating parameters for the new source such as applied spray potential, liquid and gas flow rates, and enclosure material were investigated.  相似文献   

20.
Pyrolyzed photoresist films (PPF) are introduced as planar carbon electrodes in a PDMS-quartz hybrid microchip device. The utility of PPF in electroanalytical applications is demonstrated by the separation and detection of various neurotransmitters. PPF is found to form a stable, low-capacitance, durable layer on quartz, which can then be used in conjunction with a microchip capillary electrophoretic device. Sinusoidal voltammetric detection at PPF electrodes is shown to be very sensitive, with a detection limit (S/N = 3) of 100 nM for dopamine, corresponding to a mass detection limit (S/N = 3) of 2 amol. The selectivity of analysis in the frequency domain is demonstrated by isolating each individual signal in a pair of analytes that are chromatographically unresolved. Effectively decoupling the electrophoresis and electrochemical systems allows the electrodes to be placed just inside the separation channel, which results in efficient separations (80 000-100 000 plates/m).  相似文献   