首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper deals with the utilization of a renewable energy‐based integrated system with the latent heat storage option for building thermal management systems. Both energy and exergy‐based assessments of the current combined system are conducted. For this purpose, phase change material (PCM)‐embedded radiant wall heating system using solar heating and ground source heat pump (GSHP) is studied thermodynamically. Heat is essentially stored within the PCMs as used in the panels to increase the effectiveness. The stored heat is released when the solar energy is not available. In the thermal energy storage analyses, four different PCMs are considered. The present results show that the overall first ‐ law (energy) and second ‐ law (exergy) efficiencies of the PCM‐free radiant heating system are much lower than the case with the PCM‐embedded radiant heating system. Therefore, it is confirmed that the energy efficiency increases from 62% to 87% while the exergy efficiency rises from 14% to 56% with the option where SP26E PCM is employed accordingly.  相似文献   

2.
根据上海的气候条件,以上海地区某写字楼为对象,提出4种太阳能驱动的溴化锂吸收式与电动蒸汽压缩式热泵联合制冷与供暖系统。这4种系统分别由热管式真空管集热器或抛物面槽形聚光集热器,单效或双效溴化锂吸收式制冷机,以及风冷热泵或水源热泵构成。分析比较这4种系统的节能型和经济性的结果表明,采用抛物面槽形聚光集热器+双效溴化锂吸收式制冷机+风冷热泵组成的系统,同时具备较好的节能性与经济性,一次能源利用率可降低约50%。  相似文献   

3.
A hybrid solar-assisted ground-source heat pump (SAGSHP) system was designed, in the frame of an energy upgrade study, to serve as a heating system in a school building in Greece. The main scope of this study was to examine techniques to reduce the capacity of the heating equipment and to keep the primary energy consumption low. Simulations of the thermal performance of both the building and of five different heating system configurations were performed by using the TRNSYS software. The results are presented in this work and show that the hybrid SAGSHP system displays the lower primary energy consumption among the systems examined. A conventional ground-source heat pump system has the same primary energy consumption, while the heat pump’s capacity is double and the ground heat exchanger 2.5 times longer. This work also highlights the contribution of simulation tools to the design of complex heating systems with renewable energy sources.  相似文献   

4.
《Applied Thermal Engineering》2003,23(15):1959-1970
As the alternative to the heating furnace for crude oil heating, a heat pump system utilizing produced water, a main byproduct, in oil fields was proposed and the thermodynamic model of the system was established. A particular compression process with inner evaporative spray water cooling was applied in the screw compressor and an analysis method for the variable-mass compression process was introduced. The simulation results showed that the efficiency of the screw compressor, the temperature of produced water and the temperature difference in flash process are key parameters affecting the system performance. The energy cost of the heat pump system was compared to that of the heating furnace, revealing that the heat pump system with EER, 4.67, would save over 20% energy cost as compared with the heating furnace. Thus, the heat pump system was energy saving, money saving and environmentally benign.  相似文献   

5.
The energy and exergy flow for a space heating systems of a typical residential building of natural ventilation system with different heat generation plants have been modeled and compared. The aim of this comparison is to demonstrate which system leads to an efficient conversion and supply of energy/exergy within a building system.The analysis of a fossil plant heating system has been done with a typical building simulation software IDA–ICE. A zone model of a building with natural ventilation is considered and heat is being supplied by condensing boiler. The same zone model is applied for other cases of building heating systems where power generation plants are considered as ground and air source heat pumps at different operating conditions. Since there is no inbuilt simulation model for heat pumps in IDA–ICE, different COP curves of the earlier studies of heat pumps are taken into account for the evaluation of the heat pump input and output energy.The outcome of the energy and exergy flow analysis revealed that the ground source heat pump heating system is better than air source heat pump or conventional heating system. The realistic and efficient system in this study “ground source heat pump with condenser inlet temperature 30 °C and varying evaporator inlet temperature” has roughly 25% less demand of absolute primary energy and exergy whereas about 50% high overall primary coefficient of performance and overall primary exergy efficiency than base case (conventional system). The consequence of low absolute energy and exergy demands and high efficiencies lead to a sustainable building heating system.  相似文献   

6.
E. Hahne   《Solar Energy》2000,69(6):469-493
Public awareness of energy in the early 1970s stimulated a number of projects on alternative ways of heating. The ‘Institut für Thermodynamik und Wärmetechnik’ (ITW) of the University of Stuttgart has been operating a solar heating system since 1985. Ever since, this system has been minutely monitored. In particular, the storage was painstakingly considered as it was intended to serve as a pilot facility for the much discussed problem of seasonal storage. This storage unit should be simple and cheap but heavily instrumented in order to obtain many and accurate data and it should be versatile in order to gain knowledge for operation. The solar heating is provided by collectors that are unglazed, so a heat pump is required for appropriate heating temperatures. However, the heat pump allowed for a combination of heating and cooling in our system and this proved to be very advantageous, as cooling energy is more expensive and more in demand in our building than heating energy.

The system was used in various seasonal cycles with changing conditions. It has now been operating for almost 15 years. During this period, neither storage nor collectors caused any trouble. Some difficulties were experienced with the heat pump. The first one had to be replaced; we made suggestions for improvement of the second one. This provided good COPs but there has been an occasional defect. The experience with our solar heating system was so satisfactory that, based on the knowledge gained from it, large housing projects in Friedrichshafen and Hamburg and an office building project in Chemnitz were conceived and built and are now being monitored.  相似文献   


7.
A method of improving the performance of heat pumps for domestic space heating has been investigated. The study focuses on the short-term storage of heat pump output energy in concrete floor panels. This paper describes the dynamic computer simulation of an air to water heat pump, a floor panel energy store and energy flowpaths in a dwelling. The heating plant, controls and building thermal behaviour, were simulated as a complete energy system to enable the study of interactions between the subsystems. The model heating system comprised a number of under floor water heated panels installed in ground floor rooms of a two storey dwelling. Supplementary energy was supplied by direct electric heaters situated in most rooms. Heat pump operating periods were controlled as a function of the external air temperature within two prescribed occupancy intervals per day. Results of the investigation indicate that a heat pump system using floor panel storage and emission may be efficiently managed to provide nearly continuous heating with little supplementary energy input. The short-term storage of energy in thick floor panels allowed the heat pump to be operated for extended periods without cycling. Because of this, the seasonal loss in heat pump performance resulting from intermittent operation was less than 1 per cent. Attempting to supply the total space heating load with the heat pump and floor panel system resulted in severe overheating during periods of high solar or casual gain. Under these conditions the simple control strategy based on the measurement of external air temperature was ineffective. This problem was eliminated by reducing the heat pump energy input to the dwelling and supplying about 10 per cent of the seasonal energy demand by direct electric heaters. The influence of floor panel energy storage capacity on the performance of the heating system was investigated. Concrete panel depths of between 25 and 150 mm were considered. The seasonal system efficiency was found to increase with floor panel thickness, although not significantly with panel depths beyond 100 mm. The extensive use of floor slabs to store energy caused mean floor temperatures to be higher than when using direct electric air heaters only. However, with the depth of under floor insulation considered in the study (75 mm), heating the floor slab increased the seasonal energy loss of the building by only 4 per cent.  相似文献   

8.
冯永华  林梅 《节能技术》2006,24(6):501-503
基于热力学第一定律,反映热泵能量数量关系的性能指标-供热系数,在用于评价热泵系统节能效益及对热泵系统进行可行性评价的问题上,存在一定的局限性。本文对这一问题进行了分析。在此基础上,根据热力学第二定律,提出了以热泵系统单位火用损供热率作为其性能评价指标的思想。以此作为热泵系统的性能评价指标,更科学、更客观。  相似文献   

9.
In this paper, we deal with the energy and exergy analysis of a fossil plant and ground and air source heat pump building heating system at two different dead-state temperatures. A zone model of a building with natural ventilation is considered and heat is being supplied by condensing boiler. The same zone model is applied for heat pump building heating system. Since energy and exergy demand are key parameters to see which system is efficient at what reference temperature, we did a study on the influence of energy and exergy efficiencies. In this regard, a commercial software package IDA-ICE program is used for calculation of fossil plant heating system, however, there is no inbuilt simulation model for heat pumps in IDA-ICE, different COP (coefficient of performance) curves of the earlier studies of heat pumps are taken into account for the evaluation of the heat pump input and output energy. The outcome of the energy and exergy flow analysis at two different dead-state temperatures revealed that the ground source heat pumps with ambient reference have better performance against all ground reference systems as well as fossil plant (conventional system) and air source heat pumps with ambient reference.  相似文献   

10.
《Energy》2006,31(14):2588-2603
The subject hereof are two typical examples of waste heat and low-temperature heat use and the objective is to evaluate economic effectiveness taking into account various boundary conditions. The first facility considered is an “earth-coupled” heat pump with direct evaporation used as a component of a heating system. The second is an industrial installation, based on a specific project to use waste heat from the cooling process. Alternatively, four different technical options have been considered, including the use of the compression heat pump, absorption heat pump, heat transformer (absorption) and combined system with a gas motor for driving the heat pump compressor. An original simple methodology for economic analysis evaluating uses of low-temperature heat sources as elements of energy supply systems has been developed using input data taken from actual research or industrial projects. The paper also offers a comparison between such energy supply systems operating under different economic conditions of Germany and Poland.  相似文献   

11.
热泵系统也称余热回收系统,是使用部分驱动能源(如燃气、蒸汽、燃气或热水),将余热形式为地热水、冷却水、洗涤水或伴油污水,温度在20~70℃的低品位能量取出,转移到45~100℃的中高温热媒中的系统。热泵系统在利用低品位热能的同时,仅消耗少量电能,节能效果显著。我国直到20世纪90年代,开始大面积应用热泵技术。目前,在热泵制造、安装和运行规模上,已走到了国际前例。现在,不管是压缩式热泵,还是吸收式热泵,也不论是设备还是系统,其技术已经成熟,热泵机组制热温度达到45~100℃,COP值(能量与热量之间的转换比率,简称能效比)也达到相当高的水平,机组的超小型化和超大型化技术得到长足发展,被广泛应用到建筑、烘干、石油化工、医药、筑路等领域。以热泵工艺在油田注水站的应用为分析对象,针对热泵的起源、发展、工作原理及在注水站的应用展开论述,着重从初期投资、运行费用、人工费用、社会效益、节约清水及10年费用现值方面,对注水站采用热泵冷却工艺与常规冷却工艺进行对比分析,提出了注水站采用热泵工艺有利于提高注水站系统的热能效率,降低运行成本,减少加热炉加热过程中产生的废气和余热排放,实现节能减排,对于热泵工艺在大庆油田注水站的应用具有借鉴意义。  相似文献   

12.
This paper presents a feasibility analysis for the installation of ground source heat pump systems in Cyprus. Two reference buildings, a single- and a multi-family one, are designed and analyzed using the EnergyPlus software, in order to calculate their energy needs for heating and cooling for the climate conditions of Cyprus, one of the warmest areas in Southern Europe. These energy needs are assumed to be covered by the conventional heating and cooling systems that are most widely used in Cyprus or alternatively by a ground source heat pump system, which consists of a vertical ground heat exchanger and water-to-water heat pumps and is analyzed using an in-house developed and validated code. Primary energy consumption and the resulting CO2 emissions for both the conventional and the alternative systems are calculated and compared. Results show that the installation of the ground source heat pump system achieves in most cases substantial reductions in primary energy use for both types of buildings. As regards carbon emissions, the findings are less clear: Emissions of the geothermal system are higher than those of the conventional system for the single-family building but considerably lower for the multi-family one. From an economic perspective, the geothermal system compares favorably with the conventional systems in many cases, particularly for the multi-family building.  相似文献   

13.
In this study, the compression heat pump system using wastewater, as a heat source, from hotel with sauna was designed and analyzed. This study was performed to investigate the feasibility of the wastewater use for heat pump as a heat source and to obtain engineering data for system design. This heat pump system uses off-peak electricity that is a cheap energy compared to fossil fuel in Korea. For this, the charging process of heat into the hot water storage tank is achieved only at night time (22:00–08:00). TRNSYS was used for the system simulation with some new components like the heat pump, which we create ourselves.As a result, it was forecasted that the yearly mean COP of heat pump is about 4.8 and heat pump can supply 100% of hot water load except weekend of winter season. The important thing that should be considered for the system design is to decrease the temperature difference between condenser and evaporator working fluids during the heat charging process by the heat pump. This heat pump system using wastewater from sauna, public bath, building, etc. can therefore be effectively applied not only for water heating but also space heating and cooling in regions like as Korea.  相似文献   

14.
The feasibility of solar assisted heat pump systems for space heating and domestic hot water preheating in Canada is examined by simulating the performance of these systems on a computer using the program WATSUN. Simulations are carried out using meteorological data for seven representative Canadian cities, two different building types, and six types of system configurations. For the solar assisted heat pump system, twenty year life cycle cost comparisons are made with two reference systems, namely a conventional resistance heating system and an air-to-air heat pump system, based on current economic parameters and projected escalation scenarios for electricity rates.Results of the study show that the solar assisted heat pump systems conserve significant amounts of energy over resistance heating and heat pump systems. On the life cycle unit cost basis, solar assisted heat pump systems costs are relatively insensitive to location, but the dependence on building types is substantial with multiplex dwellings showing the least cost. Liquid based dual source solar assisted heat pump systems are found to be cost effective over resistance heating (but not over an air-to-air heat pump system) at some of the locations for multiplex units. They are not cost effective for single family dwellings at the present time.  相似文献   

15.
A prototype low capacity (10 kW) single stage Li–Br absorption heat pump (AHP), suitable for residential and small building applications has been developed as a collaborative result between various European research institutes and industries. The primary heat source for the AHP is supplied from flat plate solar collectors and the hot/chilled water from the unit is delivered to a floor heating/cooling system. In this paper we present the simulation results and an overview of the performance assessment of the complete system. The calculations were performed for two building types (high and low thermal mass), three climatic conditions, with different types of solar collectors and hot water storage tank sizes and different control systems for the operation of the installation. The simulations were performed using the thermal simulation code TRNSYS. The estimated energy savings against a conventional cooling system using a compression type heat pump was found to be in the range of 20–27%.  相似文献   

16.
The heating system of the bioclimatic building of the Greek National Centre for Renewable Energy Sources (CRES) comprises two heating plants: the first one includes an air source heat pump, Solar Air Collectors (SACs) and a heat distribution system (comprising a fan coil unit network); the second one is, mainly, a geothermal heat pump unit to cover the ground floor thermal needs. The SAC configuration as well as the fraction of the building heating load covered by the heating plant are assessed in two operation modes; the direct (hot air from the collectors is supplied directly to the heated space) and the indirect mode (warm air from the SAC or its mixture with ambient air is not supplied directly to the heated space but indirectly into the evaporator of the air source heat pump). The technique of the indirect mode of heating aims at maximizing the efficiency of the SAC, saving electrical power consumed by the compressor of the heat pump, and therefore, at optimizing the coefficient of performance (COP) of the heat pump due to the increased intake of ambient thermal energy by means of the SAC. Results are given for three research objectives: assessment of the heat pump efficiency whether in direct or indirect heating mode; Assessment of the overall heating plant efficiency on a daily or hourly basis; Assessment of the credibility of the suggested simulation model TSAGAIR by comparing its results with the TRNSYS ones.  相似文献   

17.
This paper is based on the proposal of a new waste heat recovery (WHR) system, which can be utilized to heat the boiler return water, boiler supply air, and building heating air. The system is the combination of an indirect contact condensing unit (IDCCU), a mechanical compression heat pump, and two air preheaters. The system is modeled on the basis of mass and energy balance and then thermodynamically analyzed. Improved performance results were obtained in the form of an increase in the boiler's energy efficiency of about 10.47%, with 4.87% increase in exergy efficiency. The coefficient of performance (COP) of the heat pump was increased from 1.23 to 1.45 by the addition of an air heater in the conventional heat pump. The exergy destruction in each component is calculated. Sensitivity analysis was performed to check the influence of different operating parameters on the performance of the WHR system and boiler. It can be observed from the results that for a specific refrigerant temperature and a calculated amount of mass, flow rate can maximize the condensation efficiency of IDCCU by decreasing the flue gas temperature, while the use of the air heater can further reduce the flue gas temperature, and a stream of hot air can be utilized for space heating. A comparison is made with the other system on a performance basis. The results shows a clear difference in efficiencies and profit earned.  相似文献   

18.
构建空气源热泵-相变蓄热水箱供暖系统,通过相变储能技术的合理应用,优化了太阳能、空气热能等非连续能源的供能方式,有效提高了建筑中可再生能源的利用率。相变蓄热系统采用了6 m3的保温水箱作为蓄热容器,选取46#石蜡为主要相变材料,304#不锈钢管为封装材料。建立蓄热系统的三维数学模型,采用有效热熔法对相变材料的焓值进行处理,运用Fluent数值模拟软件,研究相变蓄热系统的蓄放热性能。模拟结果显示,系统的蓄热时间为9.2 h,理想蓄热量为102.4 kW·h,能够单独提供低能耗建筑连续采暖11.1 h。空气源热泵-相变蓄热水箱供暖系统能实现大跨度的间歇供暖,在利用非连续能源供暖领域具有良好的前景。  相似文献   

19.
This paper introduces a novel solar-assisted heat pump system with phase change energy storage and describes the methodology used to analyze the performance of the proposed system. A mathematical model was established for the key parts of the system including solar evaporator, condenser, phase change energy storage tank, and compressor. In parallel to the modelling work, an experimental set-up of the proposed solar energy storage heat pump system was developed. The experimental data showed that the designed system is capable of meeting cold day heating demands in rural areas of Yanbian city located in Jilin province of China. In day-time operation, the solar heat pump system stores excess energy in the energy storage tank for heating purposes. A desired indoor temperature was achieved; the average coefficient of performance of solar heat pump was identified as 4.5, and the system showed a stable performance throughout the day. In night-time operation, the energy stored in the storage tank was released through a liquid-solid change of phase in the employed phase-change material. In this way, the provision of continuous heat for ten hours was ensured within the building, and the desired indoor air conditions were achieved.  相似文献   

20.
冷暖联供太阳能喷射制冷系统的一次能耗   总被引:3,自引:0,他引:3  
太阳能喷射式制冷(热泵)系统在满足供冷、供热需求时,通常需要补充一定量的一次常规能源。该文在系统能量平衡的基础上,引入太阳能倍率、冬夏负荷比等参数,推导了太阳能制冷系统与电压缩制冷系统的一次能耗比计算公式。进而对太阳能双元混合工质喷射式制冷(热泵)系统、单元工质喷射式制冷系统、太阳能直接供热系统与电压缩制冷系统的一次能源消耗进行了对比分析。结果表明,太阳能喷射式热泵比太阳能直接供暖系统节约一次常规能源;太阳能喷射式制冷(热泵)系统,在其太阳能倍率位于节能区时,比电压缩制冷(热泵)系统节约一次常规能源。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号