首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 701 毫秒
1.
Multiphoton fluorescence excitation microscopy is almost invariably conducted with samples whose refractive index differ from that of the objective immersion medium, conditions that cause spherical aberration. Due to the quadratic nature of multiphoton fluorescence excitation, spherical aberration is expected to profoundly affect the depth dependence of fluorescence excitation. In order to determine the effect of refractive index mismatch in multiphoton fluorescence excitation microscopy, we measured signal attenuation, photobleaching rates and resolution degradation with depth in homogeneous samples with minimal light scattering and absorption over a range of refractive indices. These studies demonstrate that signal levels and resolution both rapidly decline with depth into refractive index mismatched samples. Analyses of photobleaching rates indicate that the preponderance of signal attenuation with depth results from decreased rates of fluorescence excitation, even in a system with a descanned emission collection pathway. Similar results were obtained in analyses of fluorescence microspheres embedded in rat kidney tissue, demonstrating that spherical aberration is an important limiting factor in multiphoton fluorescence excitation microscopy of biological samples.  相似文献   

2.
The use of high numerical aperture immersion lenses in optical microscopy is compromised by spherical aberrations induced by the refractive index mismatch between the immersion system and the embedding medium of the sample. Especially when imaging >10 micro m deep into the specimen, the refractive index mismatch results in a noticeable loss of image brightness and resolution. A solution to this problem is to adapt the index of the embedding medium to that of the immersion system. Unfortunately, not many mounting media are known that are both index tunable as well as compatible with fluorescence imaging. Here we introduce a nontoxic embedding medium, 2,2'-thiodiethanol (TDE), which, by being miscible with water at any ratio, allows fine adjustment of the average refractive index of the sample ranging from that of water (1.33) to that of immersion oil (1.52). TDE thus enables high resolution imaging deep inside fixed specimens with objective lenses of the highest available aperture angles and has the potential to render glycerol embedding redundant. The refractive index changes due to larger cellular structures, such as nuclei, are largely compensated. Additionally, as an antioxidant, TDE preserves the fluorescence quantum yield of most of the fluorophores. We present the optical and chemical properties of this new medium as well as its application to a variety of differently stained cells and cellular substructures.  相似文献   

3.
The effect of refractive index mismatch on the image quality in two-photon confocal fluorescence microscopy is investigated by experiment and numerical calculations. The results show a strong decrease in the image brightness using high-aperture objectives when the image plane is moved deeper into the sample. When exciting at 740 nm and recording the fluorescence around 460 nm in a glycerol-mounted sample using a lens of a numerical aperture of 1·4 (oil immersion), a 25% decrease in the intensity is observed at a depth of 9 μm. In an aqueous sample, the same decrease is observed at a depth of 3 μm. By reducing the numerical aperture to 1·0, the intensity decrease can be avoided at the expense of the overall resolution and signal intensity. The experiments are compared with the predictions of a theory that takes into account the vectorial character of light and the refraction of the wavefronts according to Fermat's principle. Advice is given concerning how the effects can be taken into account in practice.  相似文献   

4.
Nonlinear microscopies including multiphoton excitation fluorescence microscopy and multiple-harmonic generation microscopy have recently gained popularity for cellular and tissue imaging. The optimization of these imaging methods for minimally invasive use requires optical fibers to conduct light into tight space, where free-space delivery is difficult. The delivery of high-peak power laser pulses with optical fibers is limited by dispersion resulting from nonlinear refractive index responses. In this article, we characterize a variety of commonly used optical fibers in terms of how they affect pulse profile and imaging performance of nonlinear microscopy; the following parameters are quantified: spectral bandwidth and temporal pulse width, two-photon excitation efficiency, and optical resolution. A theoretical explanation for the measured performance of these fibers is also provided.  相似文献   

5.
Huang Z  Zhuo S  Chen J  Chen R  Jiang X 《Scanning》2008,30(6):452-456
The fresh adipose tissue was investigated by the use of multiphoton microscopy (MPM) based on two-photon excited fluorescence and second-harmonic generation (SHG). Microstructure of collagen and adipose cells in the adipose tissue is clearly imaged at a subcellular level with the excitation light wavelengths of 850 and 730 nm, respectively. The emission spectrum of collagen SHG signal and NADH and FAD fluorescence signal can also be obtained, which can be used to quantify the content of collagen and adipose cells and reflect the degree of pathological changes when comparing normal tissue with abnormal adipose tissue in the same condition. The results indicate that MPM has the potential to be applied to investigate the adipose tissue and can be used in the research field of lipid and connective tissues.  相似文献   

6.
Multiphoton microscopy in life sciences   总被引:13,自引:1,他引:12  
Near infrared (NIR) multiphoton microscopy is becoming a novel optical tool of choice for fluorescence imaging with high spatial and temporal resolution, diagnostics, photochemistry and nanoprocessing within living cells and tissues. Three‐dimensional fluorescence imaging based on non‐resonant two‐photon or three‐photon fluorophor excitation requires light intensities in the range of MW cm?2 to GW cm?2, which can be derived by diffraction limited focusing of continuous wave and pulsed NIR laser radiation. NIR lasers can be employed as the excitation source for multifluorophor multiphoton excitation and hence multicolour imaging. In combination with fluorescence in situ hybridization (FISH), this novel approach can be used for multi‐gene detection (multiphoton multicolour FISH). Owing to the high NIR penetration depth, non‐invasive optical biopsies can be obtained from patients and ex vivo tissue by morphological and functional fluorescence imaging of endogenous fluorophores such as NAD(P)H, flavin, lipofuscin, porphyrins, collagen and elastin. Recent botanical applications of multiphoton microscopy include depth‐resolved imaging of pigments (chlorophyll) and green fluorescent proteins as well as non‐invasive fluorophore loading into single living plant cells. Non‐destructive fluorescence imaging with multiphoton microscopes is limited to an optical window. Above certain intensities, multiphoton laser microscopy leads to impaired cellular reproduction, formation of giant cells, oxidative stress and apoptosis‐like cell death. Major intracellular targets of photodamage in animal cells are mitochondria as well as the Golgi apparatus. The damage is most likely based on a two‐photon excitation process rather than a one‐photon or three‐photon event. Picosecond and femtosecond laser microscopes therefore provide approximately the same safe relative optical window for two‐photon vital cell studies. In labelled cells, additional phototoxic effects may occur via photodynamic action. This has been demonstrated for aminolevulinic acid‐induced protoporphyrin IX and other porphyrin sensitizers in cells. When the light intensity in NIR microscopes is increased to TW cm?2 levels, highly localized optical breakdown and plasma formation do occur. These femtosecond NIR laser microscopes can also be used as novel ultraprecise nanosurgical tools with cut sizes between 100 nm and 300 nm. Using the versatile nanoscalpel, intracellular dissection of chromosomes within living cells can be performed without perturbing the outer cell membrane. Moreover, cells remain alive. Non‐invasive NIR laser surgery within a living cell or within an organelle is therefore possible.  相似文献   

7.
A benefit of multiphoton fluorescence microscopy is the inherent optical sectioning that occurs during excitation at the diffraction-limited spot. The scanned collection of fluorescence emission is incoherent; that is, no real image needs to be formed on the detector plane. The nearly isotropic emission of fluorescence excited at the focal spot allows for new detection schemes that efficiently funnel all attainable photons to detector(s). We previously showed [Combs, C.A., et al. (2007) Optimization of multiphoton excitation microscopy by total emission detection using a parabolic light reflector. J. Microsc. 228, 330-337] that parabolic mirrors and condensers could be combined to collect the totality of solid angle around the excitation spot for tissue blocks, leading to ~8-fold signal gain. Using a similar approach, we have developed an in vivo total emission detection (epiTED) instrument modified to make noncontact images from outside of living tissue. Simulations suggest that a ~4-fold enhancement may be possible (much larger with lower NA objectives than the 0.95 NA used here) with this approach, depending on objective characteristics, imaging depth and the characteristics of the sample being imaged. In our initial prototype, 2-fold improvements were demonstrated in the mouse brain and skeletal muscle as well as the rat kidney, using a variety of fluorophores and no compromise of spatial resolution. These results show this epiTED prototype effectively doubles emission signal in vivo; thus, it will maintain the image signal-to-noise ratio at two times the scan rate or enable full scan rate at approximately 30% reduced laser power (to minimize photo-damage).  相似文献   

8.
折射率失配对双光子三维信息存储中信息点的影响   总被引:2,自引:1,他引:1  
根据Torok的光在多层介质中传播的理论,模拟了在折射率失配情况下点扩展函数的强度分布.在介质折射率为1.48,多种物镜数值孔径NA=0.25、0.45、0.65、0.85条件下,分析了信息点轴向尺寸及读出信号强度变化趋势.选取合适的光学参数(如物镜的数值孔径NA=0.45,存储介质的折射率1.48),能够使信息点在深度200μm内轴向尺寸变化率小于4%,信号读出强度变化率小于30%,提高了存储效果.对选取各种物镜和介质折射率的情况下信息点的变化趋势分析表明,折射率失配使信息点横向尺寸随深度变化不大,而轴向尺寸及信号读出强度产生较大的变化,变化的程度与物镜NA、介质的折射率及存储深度密切相关.采用与模拟时相同的光学参数,在光致变色材料中进行了双光子三维存储实验.通过观察信息点的轴向及横向扫描图像和信号的读出强度,证实了这种变化趋势.实验结果为双光子三维存储提供了参考依据.  相似文献   

9.
Limitations on optical sectioning in live-cell confocal microscopy   总被引:5,自引:0,他引:5  
Pawley JB 《Scanning》2002,24(5):241-246
In three-dimensional (3-D) live-cell microscopy, it has been common to treat cells as having a constant refractive index (RI). Although the variations in RI associated with the nucleus and other organelles were recognized from phase- and differential interference contrast (DIC) images, it was assumed that they were small and would not affect 3-D fluorescence images obtained using widefield/deconvolution, confocal of multiphoton imaging. This paper makes clear that this confidence was misplaced. Confocal images made using backscattered light (BSL) to image the flat, glass/water interfaces above and below living microscope specimens should reveal these structures as flat and featureless. That the image of the interface on the far side of the cells is neither flat nor featureless indicates that the "optical section" surface can be profoundly distorted by the RI irregularities associated with the presence of nuclei and other subcellar structures. This observation calls into question the reliability of images made using any of the current methods for performing 3-D light microscopy of living cells.  相似文献   

10.
Accurate distance measurement in 3D confocal microscopy is important for quantitative analysis, volume visualization and image restoration. However, axial distances can be distorted by both the point spread function (PSF) and by a refractive‐index mismatch between the sample and immersion liquid, which are difficult to separate. Additionally, accurate calibration of the axial distances in confocal microscopy remains cumbersome, although several high‐end methods exist. In this paper we present two methods to calibrate axial distances in 3D confocal microscopy that are both accurate and easily implemented. With these methods, we measured axial scaling factors as a function of refractive‐index mismatch for high‐aperture confocal microscopy imaging. We found that our scaling factors are almost completely linearly dependent on refractive index and that they were in good agreement with theoretical predictions that take the full vectorial properties of light into account. There was however a strong deviation with the theoretical predictions using (high‐angle) geometrical optics, which predict much lower scaling factors. As an illustration, we measured the PSF of a correctly calibrated point‐scanning confocal microscope and showed that a nearly index‐matched, micron‐sized spherical object is still significantly elongated due to this PSF, which signifies that care has to be taken when determining axial calibration or axial scaling using such particles.  相似文献   

11.
基于低相干光干涉的液体折射率测量   总被引:1,自引:0,他引:1  
液体折射率是液体一个重要指标,介质中折射率的变化会影响光程,提出一种用低相干光干涉测量光程变化,进而测得折射率的方法。通过调节两束低相干光使它们之间的光程差在相干长度之内,将被测液体放入一束光路中,根据光电探测器得到的干涉信号可求得相应的光程变化量,进而得到待测液体的折射率。利用低相干光干涉测量折射率的方法,其测量和计算过程方便快捷,受外界限制因素小,在810nm波长下,对折射率的测量精度可以达到10-4量级以上,是测量各种液体折射率的有效方法。  相似文献   

12.
Live imaging in cell biology requires three‐dimensional data acquisition with the best resolution and signal‐to‐noise ratio possible. Depth aberrations are a major source of image degradation in three‐dimensional microscopy, causing a significant loss of resolution and intensity deep into the sample. These aberrations occur because of the mismatch between the sample refractive index and the immersion medium index. We have built a wide‐field fluorescence microscope that incorporates a large‐throw deformable mirror to simultaneously focus and correct for depth aberration in three‐dimensional imaging. Imaging fluorescent beads in water and glycerol with an oil immersion lens we demonstrate a corrected point spread function and a 2‐fold improvement in signal intensity. We apply this new microscope to imaging biological samples, and show sharper images and improved deconvolution.  相似文献   

13.
This study examined the action of anisosmotic media on the volume of nucleated erythrocytes isolated from Rana temporaria. Elevation of medium osmolarity from 100 to 345 mOsm resulted in attenuation of mean cell volume by more than 3-fold, estimated by hematocrit measurement. By contrast to this 'classic' erythrocyte volume evaluation technique, we did not observe any significant cell volume modulation by examining the 3D reconstruction of erythrocyte interference images obtained by laser interference microscopy. Comparative analysis of mean cell volume, phase height and cell area appraised by laser interference microscopy showed that the lack of visible alterations of phase image geometry was caused by sharp elevation of the average refractive index of the cytoplasm in shrunken cells. Thus, our results show for the first time that laser interference microscopy in combination with a direct method for cell volume measurement may be employed for estimation of the refractory index of intracellular milieu and for assessment of changes of physical chemical properties of the cytoplasm evoked by diverse stimuli including osmotic stress.  相似文献   

14.
Multiphoton microscopy is a powerful technique for achieving three-dimensional submicron imaging in biological specimens. However, specimen optical parameters such as refractive indices and scattering coefficients can result in the loss of image resolution and decreased signal in depth. These factors are coupled to the focusing objective's numerical aperture (NA) in limiting the achievable imaging depths. In this work, we performed multiphoton imaging on aqueous fluorescent solution, human skin, and rat tail tendon to show that, under the same immersion condition, lower NA objectives can examine more deeply into biological specimens and should be used when optimal imaging depths is desired.  相似文献   

15.
This study proposes a method for measuring the refractive index of articular cartilage within a thin and small specimen slice. The cartilage specimen, with a thickness of about 50 μm, was put next to a thin film of immersion oil of similar thickness. Both the articular cartilage and immersion oil were scanned along the depth direction using a confocal microscope. The refractive index mismatch between the cartilage and the immersion oil induced a slight axial deformation in the confocal images of the cartilage specimen that was accurately measured by a subpixel edge‐detection‐based technique. A theoretical model was built to quantify the focal shift of confocal microscopy caused by the refractive index mismatch. With the quantitative deformations of cartilage images and the quantified function of focal shift, the refractive index of articular cartilage was accurately interpolated. At 561 nm, 0.1 MPa and 20 °C, the overall refractive index of the six cartilage plugs was 1.3975 ± 0.0156. The overall coefficient of variation of all cartilage specimens was 0.68%, which indicated the high repeatability of our method. The verification experiments using distilled water showed a minimal relative error of 0.02%.  相似文献   

16.
Multiphoton excitation was originally projected to improve live cell fluorescence imaging by minimizing photobleaching effects outside the focal plane, yet reports suggest that photobleaching within the focal plane is actually worse than with one photon excitation. We confirm that when imaging enhanced green fluorescent protein, photobleaching is indeed more acute within the multiphoton excitation volume, so that whilst fluorescence increases as predicted with the square of the excitation power, photobleaching rates increase with a higher order relationship. Crucially however, multiphoton excitation also affords unique opportunities for substantial improvements to fluorescence detection. By using a Pockels cell to minimize exposure of the specimen together with multiple nondescanned detectors we show quantitatively that for any particular bleach rate multiphoton excitation produces significantly more signal than one photon excitation confocal microscopy in high resolution Z‐axis sectioning of thin samples. Both modifications are readily implemented on a commercial multiphoton microscope system.  相似文献   

17.
Multiphoton confocal microscopy using a femtosecond Cr:forsterite laser   总被引:2,自引:0,他引:2  
Liu TM  Chu SW  Sun CK  Lin BL  Cheng PC  Johnson I 《Scanning》2001,23(4):249-254
With its output wavelength covering the infrared penetrating window of most biological tissues at 1,200-1,250 nm, the femtosecond Cr:forsterite laser shows high potential to serve as an excellent excitation source for the multiphoton fluorescence microscope. Its high output power, short optical pulse width, high stability, and low dispersion in fibers make it a perfect replacement for the currently widely used Ti:sapphire laser. In this paper, we study the capability of using a femtosecond Cr:forsterite laser in multiphoton scanning microscopy. We have performed the multiphoton excited photoluminescence spectrum measurement on several commonly used bioprobes using the 1,230 nm femtosecond pulses from a Cr:forsterite laser. Efficient fluorescence can be easily observed in these bioprobes through two-photon or three-photon excitation processes. These results will assist in the selection of dichroic beam splitter and band pass filters in a multiphoton microscopic system. We have also performed the autofluorescence spectrum measurement from chlorophylls in live leaves of the plant Arabidopsis thaliana excited by 1,230 nm femtosecond pulses from the Cr:forsterite laser. Bright luminescence from chlorophyll, centered at 673 and 728 nm, respectively, can be easily observed. Taking advantage of the bright two-photon photoluminescence from chlorophyll, we demonstrated the two-photon scanning paradermal and cross-sectional images of palisade mesophyll cells in live leaves of Arabidopsis thaliana.  相似文献   

18.
A difference in refractive index (n) between immersion medium and specimen results in increasing loss of intensity and resolution with increasing focal depth and in an incorrect axial scaling in images of a confocal microscope. Axial thickness measurements of an object on such images are therefore not exact. The present paper describes a simple procedure to determine the correct axial thickness of an object with confocal fluorescence microscopy. We study this procedure for a specimen that has a higher refractive index than the immersion medium and with a thickness up to 100 µm. The measuring method was experimentally tested by comparing the thickness of polymer layers measured on axial images of a confocal microscope in case of a water–polymer mismatch to reference values obtained from an independent technique, i.e. scanning electron microscopy. The case when the specimen has a lower refractive index than the immersion medium is also shown by way of illustration. Measured thickness data of a water layer and an oil layer with the same actual thickness were obtained using an oil-immersion objective lens with confocal microscopy. Good agreement between theory and experiment was found in both cases, consolidating our method.  相似文献   

19.
It is demonstrated that cytoplasmic laminar bodies (CLBs) can be identified in Nissl stained celloidin sections by means of phase contrast microscopy. Provided that the refractive index of the mounting medium is in the range of 1.56 to 1.65, CLBs appear as bright holes in the cytoplasm.  相似文献   

20.
This article reports about the development and application of a standing-wave fluorescence microscope (SWFM) with high nodal plane flatness. As opposed to the uniform excitation field in conventional fluorescence microscopes an SWFM uses a standing-wave pattern of laser light. This pattern consists of alternating planar nodes and antinodes. By shifting it along the axis of the microscope a set of different fluorescent structures can be distinguished. Their axial separation may just be a fraction of a wavelength so that an SWFM allows distinction of structures which would appear axially unresolved in a conventional or confocal fluorescence microscope. An SWFM is most powerful when the axial extension of the specimen is comparable to the wavelength of light. Otherwise several planes are illuminated simultaneously and their separation is hardly feasible. The objective of this work was to develop a new SWFM instrument which allows standing-wave fluorescence microscopy with controlled high nodal plane flatness. Earlier SWFMs did not allow such a controlled flatness, which impeded image interpretation and processing. Another design goal was to build a compact, easy-to-use instrument to foster a more widespread use of this new technique. The instrument developed uses a green-emitting helium–neon laser as the light source, a piezoelectric movable beamsplitter to generate two mutually coherent laser beams of variable relative phase and two single-mode fibres to transmit these beams to the microscope. Each beam is passed on to the specimen by a planoconvex lens and an objective lens. The only reflective surface whose residual curvature could cause wavefront deformations is a dichroic beamsplitter. Nodal plane flatness is controlled via interference fringes by a procedure which is similar to the interferometric test of optical surfaces. The performance of the instrument was tested using dried and fluorescently labelled cardiac muscle cells of rats. The SWFM enabled the distinction of layers of stress fibres whose axial separation was just a fraction of a wavelength. Layers at such a small distance would lie completely within the depth-of-field of a conventional or confocal fluorescence microscope and could therefore not be distinguished by these two methods. To obtain futher information from the SWFM images it would be advantageous to use the images as input-data to image processing algorithms such as conceived by Krishnamurthi et al. (Proc. SPIE, 2655, 1996, 18–25). To minimize specimen-caused nodal plane distortion, the specimen should be embedded in a medium of closely matched refractive index. The proper match of the refractive indices could be checked via the method presented here for the measurement of nodal plane flatness. For this purpose the fluorescent layer of latex beads would simply be replaced by the specimen. A combination of the developed SWFM with a specimen embedded in a medium of matched refractive index and further image processing would exploit the full potential of standing-wave fluorescence microscopy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏