首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Effect of parameters of ion implantation machine, including ion energy, total dose, dose rate, impulse energy and implantation interval on the pollen grains of upland cotton implanted with nitrogen ion beam were studied. The best parameters were screened out. The results also showed that the vacuum condition before the nitrogen ion implantation does not affect the pollen viability.  相似文献   

2.
Optical emission spectroscopy in nitrogen glow discharge plasma is simulated, and the collision excitations and characteristic emissions of the species (N2, N2^+, N^+, N) are investigated by a Monte Carlo model for nitrogen molecular gas discharge. The excitation rates of the main excited states are calculated and the corresponding relation and relative magnitude between the distribution of excitation rate of a certain excited state and the distributions of the emission rates of various lines originating from this excited level are also explored. The simulated results are compared with the experimental measurements in two typical discharge conditions. The luminescence mechanism of the line N2^+: 391.4 nm is explained based on the microscopic plasma processes. The cathode glow in N2 discharge is found to be mainly caused by N^+ impact excitation and the intensity of cathode glow decreases with the voltage. The corresponding relation between the emission rate or intensity of the 391.4 nm line and the production rate and the density of N2^+ is also examined.  相似文献   

3.
Natural cellulose was treated by an atmospheidc DBD plasma. The solubility of cellulose in a diluted alkaline solution after the plasma treatment was investigated. The properties were characterized by X-ray photoelectron spectroscopy (XPS), Fourier-transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM). The results indicated that the surface of cellulose treated by the argon DBD plasma was significantly etched, and the relevant force of hydrogen bonding was decreased. This might be the essential reason for the solubility improvement of natural cellulose in the diluted alkaline solution. Through a comparison of two discharge modes, the atmospheric DBD plasma gun and the parallel plate capacitively coupled DBD plasma, it was found that the atmospheric DBD plasma gun was more effective in fragmentizing the cellulose due to its production of a high energy plasma based on its special structure.  相似文献   

4.
Particle melting and substrate temperature are important in controlling deposited density and residual stress in thermal plasma deposition of refractory materials. In this paper, both the heating and cooling behaviours of tungsten particles inside a radio frequency inductively coupled plasma (ICP) and the plasma heat flux to the substrate were investigated. The distribution of the plasma-generated heat on device, powder injection probe, deposition chamber, and substrate was determined by measuring the water flow rate and the flow-in and flow-out water temperatures in the four parts. Substrate temperature was measured by a two-colour pyrometer during the ICP deposition of tungsten. Experimental results show that the heat flux to the substrate accounts for about 20% of the total plasma energy, the substrate temperature can reach as high as 2100 K, and the heat loss by radiation is significant in the plasma deposition of tungsten.  相似文献   

5.
A gyrokinetic model with integral eigenmode equations is developed based on the local equilibrium of shaped tokamak plasmas. Effects of main geometric parameters (finite aspect ratio, elongation, triangularity, and Shafranov shift gradient) on the electrostatic electron temper- ature gradient (ETG) driven modes are investigated numerically. It is found that the finite aspect ratio has a general stabilizing effect, while the elongation can be either stabilizing or destabilizing, depending on the poloidal wavelength of the mode and other parameters. It is shown that a low aspect ratio enhances the stabilizing effect of elongation, and weakens its destabilizing effect as well.  相似文献   

6.
The oxidative degradation of aqueous carbofuran, a heavily used toxic carbamate insecticide by low temperature plasma, was investigated. The results show that the treatment efficiency increases with the increase in initial concentration. Raising the treatment temperature and changing the pH value can result in enhanced degradation of carbofuran in solution. The results also show that low temperature plasma treatment can effectively remove chemical oxygen demand (COD) of carbofuran in the solution.  相似文献   

7.
A visible light imaging Thomson scattering (VIS-TVTS) diagnostic system has been developed for the measurement of plasma electron temperature on the HT-7 tokamak. The system contains a Nd:YAG laser (A = 532 nm, repetition rate 10 Hz, total pulse duration ≈ 10 ns, pulse energy 〉 1.0 J), a grating spectrometer, an image intensifier (I.I.) lens coupled with an electron multiplying CCD (EMCCD) and a data acquisition and analysis system. In this paper, the measurement capability of the system is analyzed. In addition to the performance of the system, the capability of measuring plasma electron temperature has been proved. The profile of electron temperature is presented with a spatial resolution of about 0.96 cm (seven points) near the center of the plasma.  相似文献   

8.
Most materials can be easily corroded or ineffective in carbonaceous atmospheres at high temperatures in the reactor core of the high temperature gas-cooled reactor (HTGR). To solve the problem, a material performance test apparatus was built to provide reliable materials and technical support for relevant experiments of the HTGR. The apparatus uses a center high-purity graphite heater and surrounding thermal insulating layers made of carbon fiber felt to form a strong carbon reducing atmosphere inside the apparatus. Specially designed tungsten rhenium thermocouples which can endure high temperatures in carbonaceous atmospheres are used to control the temperature field. A typical experimental process was analyzed in the paper, which lasted 76 hours including seven stages. Experimental results showed the test apparatus could completely simulate the carbon reduction atmosphere and high temperature environment the same as that confronted in the real reactor and the performance of screened materials had been successfully tested and verified. Test temperature in the apparatus could be elevated up to 1600℃, which covered the whole temperature range of the normal operation and accident condition of HTGR and could fully meet the test reauirements of materials used in the reactor.  相似文献   

9.
Temperature and Nitric Oxide Generation in a Pulsed Arc Discharge Plasma   总被引:1,自引:0,他引:1  
Nitric oxide (NO) is increasingly being used in medical treatments of high blood pressure, acute respiratory distress syndrome and other illnesses related to the lungs. Currently a NO inhalation system consists of a gas cylinder of N2 mixed with a high concentration of NO. This arrangement is potentially risky due to the possibility of an accidental leak of NO from the cylinder. The presence of NO in the air leads to the formation of nitric dioxide (NO2), which is toxic to the lungs. Therefore, an on-site generator of NO would be highly desirable for medical doctors to use with patients with lung disease.
To develop the NO inhalation system without a gas cylinder, which would include a high concentration of NO, NAMIHIRA et al have recently reported on the production of NO from room air using a pulsed arc discharge. In the present work, the temperature of the pulsed arc discharge plasma used to generate NO was measured to optimize the discharge condition. The results of the temperature measurements showed the temperature of the pulsed arc discharge plasma reached about 10,000 K immediately after discharge initiation and gradually decreased over tens of microseconds. In addition, it was found that NO was formed in a discharge plasma having temperatures higher than 9,000 K and a smaller input energy into the discharge plasma generates NO more efficiently than a larger one.  相似文献   

10.
The electronic excitation temperature of a surface dielectric barrier discharge (DBD) at atmospheric pressure has been experimentally investigated by optical emission spectroscopic measurements combined with numerical simulation. Experiments have been carried out to deter- mine the spatial distribution of electric field by using FEM software and the electronic excitation temperature in discharge by calculating ratio of two relative intensities of atomic spectral lines. In this work, we choose seven Ar atomic emission lines at 415.86 nm [(3s^23p^5)5p →(3s^23p^5)4s] and 706.7 nm, 714.7 nm, 738.4 nm, 751.5 nm, 794.8 nm and 800.6 nm [(3s^23p^5)4p → (3s^23p^5)4s] to estimate the excitation temperature under a Boltzmann approximation. The average electron energy is evaluated in each discharge by using line ratio of 337.1 nm (N2(C^3Пu →B3Пg)) to 391.4 nm (N2^+(B2 ∑u^+→ ∑g^+)). Furthermore, variations of the electronic excitation tempera- ture are presented versus dielectric thickness and dielectric materials. The discharge is stable and uniform along the axial direction, and the electronic excitation temperature at the edge of the copper electrode is the largest. The corresponding average electron energy is in the range of 1.6- 5.1 eV and the electric field is in 1.7-3.2 MV/m, when the distance from copper electrode varies from 0 cm to 6 cm. Moreover, the electronic excitation temperature with a higher permittivity leads to a higher dissipated electrical power.  相似文献   

11.
A detailed study of photon temperatures (Tph) of hard X-ray emission in lower hybrid current drive (LHCD) plasmas is presented. The photon temperature increases with the increase in plasma current and decreases with the increase in plasma density. In lower hybrid power and phase scanning experiments; there is no appreciable change in the photon temperature. The numerical results based on ray-tracing calculation and Fokker-Planck solver gives reasonable explanation for the experimental observation. Both experimental and numerical results reveal that the photon temperature depends mainly on global effects of the fast electron population, synergy between the fast electron and the loop voltage and the Coulomb slowing down.  相似文献   

12.
A method to determine excitation temperatures based on the optical emission spectroscopy (OES) and Fermi-Dirac distribution was set up, and the temperatures of pure-argon and mixed-gases at different pressures were investigated. In this way we set up a standard process to get the excitation temperatures of plasmas operated at atmospheric and sub-atmospheric pressures.  相似文献   

13.
Hydrogenated amorphous silicon (a-Si: H) films were deposited on Si (100) and glass substrates by dielectric barrier discharge enhanced chemical vapour deposition (DBD-CVD) in (SiH4+H2) atmosphere at room temperature.
Results of the thickness measurement, SEM (scanning electron microscope), Raman, and FTIR (Fourier transform infrared spectroscopy) show that with the increase in the applied peak voltage, the deposition rate and network order of the films increase, and the hydrogen bonding configurations mainly in di-hydrogen (Si-H2) and poly hydrogen (SiH2)n are introduced into the films. The UV-visible transmission spectra show that with the decrease in SiH4/ (SiHn+H2) the thin films' band gap shifts from 1.92 eV to 2.17 eV.
These experimental results are in agreement with the theoretic analysis of the DBD discharge. The deposition of a-Si: H films by the DBD-CVD method as reported here for the first time is attractive because it allows fast deposition of a-Si: H films on large-area low-melting-point substrates and requires only a low cost of production without additional heating or pumping equipment.  相似文献   

14.
To get an optimized pulsed electrical plasma discharge reactor and to increase the energy utilization efficiency in the removal of pollutants, two hybrid plasma discharge reactors were designed and optimized. The reactors were compared via the discharge characteristics, energy transfer efficiency, the yields of the active species and the energy utilization in dye wastewater degradation. The results showed that under the same AC input power, the characteristics of the discharge waveform of the point-to-plate reactor were better. Under the same AC input power, the two reactors both had almost the same peak voltage of 22 kV. The peak current of the point-to-plate reactor was 146 A, while that of the wire-to-cylinder reactor was only 48.8 A. The peak powers of the point-to-plate reactor and the wire-to-cylinder reactor were 1.38 MW and 1.01 MW, respectively. The energy per pulse of the point-to-plate reactor was 0.2221 J, which was about 29.4% higher than that of the wire-to-cylinder reactor (0.1716 J). To remove 50% Acid Orange 7 (AO7), the energy utilizations of the point-to-plate reactor and the wire- to-cylinder reactor were 1.02×10^-9 mol/L and 0.61×10^-9 mol/L, respectively. In the point-to- plate reactor, the concentration of hydrogen peroxide in pure water was 3.6 mmol/L after 40 min of discharge, which was higher than that of the wire-to-cylinder reactor (2.5 mmol/L). The concentration of liquid phase ozone in the point-to-plate reactor (5.7×10^-2 mmol/L) was about 26.7% higher than that in the wire-to-cylinder reactor (4.5×10^-2 mmol/L). The analysis results of the variance showed that the type of reactor and reaction time had significant impacts on the yields of the hydrogen peroxide and ozone. The main degradation intermediates of AO7 identified by gas chromatography and mass spectrometry (GCMS) were acetic acid, maleic anhydride, p- benzoquinone, phenol, benzoic acid, phthalic anhydride, coumarin and 2-naphthol. Proposed degradation pathways were elucidated in light of the ana  相似文献   

15.
In order to obtain Pleurotus ferulae with high temperature tolerance,mycelium mono-cells of wild type strain ACK was treated by nitrogen ion(5~30 keV,1.5×1015~1.5×1016cm-12)implantation,and mutant CGMCC1762 was selected through auxotrophy screening method,which was Lys.VB6 auxotrophy stress with high temperature.We found that during riper period the surface layer mycelium of the mutant was not aging neither grew tegument even above 30℃.The mycelium endurable temperature of the mutant was increased 70℃ compared with that of the wild type strain.The fruiting bodies growth temperature of the mutant was 16-20℃ in daytime and was 6~12℃ at night.The highest growth temperature of fruiting bodies of the mutant Was increased by 5℃ than that of original strain.Through three generation investigation,we found that the mutant CGMCC1762 was stable with high temperature tolerance.  相似文献   

16.
The temperature of fragmenting source in central heavy-ion collisions at Fermi energy is investigated by the isospin-dependent quantum molecular dynamics model in combination with the statistical decay model GEMINI. Five different nuclear thermometers are used to extract nuclear temperature. We find that the He and Li isotope temperature reaches a plateau at about 70-100 MeV/nucleon of beam energy. The slope temperature and the quadrupole fluctuation temperature give high values. The quantum slope temperature and the quantum quadrupole fluctuation temperature are more close to the He and Li isotope temperatures.  相似文献   

17.
The symmetry energy at the time of the production of intermediate mass fragments (IMFs) is studied using experimentally observed IMF multiplicities combined with quantum statistical model calculations (QSM of Hahn and Stfcker). The ratios of difference in chemical potentials between neutrons and protons relative to the temperature,(μt- μp) /T, and the double ratio temperature, T, were extracted experimentally in the reactions of 64'7~Zn, 64Ni+58'64Ni, 112'124Sn, 197Au, 232Th at 40A MeV. The extracted (μt- μp) / T scales linearly with Jwv, where fi~v is the asymmetry parameter, (N-Z)/A, of the emitting source and (μt- μp) / T = (11.1 + 1.4)rNN -- 0.21 was derived. The experimentally extracted (μt-μp)/T and the double ratio temperatures are compared with those from the QSM calculations. The temperatures, T, and densities, p, extracted from the (μn - μp) / T values agreed with those from the double ratio thermometer which used the yield ratios of d, t, h and a particles. However the two analyses of the differential chemical potential analysis and the initial temperature analysis end up almost identical relation between T and p. T=5.25±0.75 MeV is evaluated from the (μn -μp) / T analysis, but no density determination was possible. From the extracted T value, the symmetry energy coefficient Esym=14.6±3.5 MeV is determined for the emitting source of T=5.25±0.75 MeV.  相似文献   

18.
A mini-type of plasma source was studied experimentally. The results showed that the plasma density, which was generated by an atmospheric non-equilibrium plasma source, rises with the increase in driving electric-field and the momentum of gas particles. For a driving electricfield of 56 kV/cm and a gas particles' momentum of 10^9 × 10^-22 g·m/s, the ion density can exceed 10^10/cm^3 while the effective volume of the plasma source is only 2.5 cm^2. This study may help develop a method to generate a minitype plasma source with low energy consumption but high ion concentration. This source can be used in chemical industry, environmental engineering and military applications.  相似文献   

19.
In order to test the klystrons operated at a frequency of 3.7 GHz in a continuous wave (CW) mode, a type of water load to absorb its power up to 750 kW is presented. The distilled water sealed with an RF ceramic window is used as the absorbent. At a frequency range of 70 MHz, the VSWR (Voltage Standing Wave Ratio) is below 1.2, and the rise in temperature of water is about 30 ℃ at the highest power level.  相似文献   

20.
Temperature measurement by IR (infrared) camera was performed oll HT-T tokamak. particularly during long pulse discharges, during which the temperature of the hot spots on the belt limiter exceeded 1000℃. The heat load on the surface of the movable limiter could be obtained through ANSYS with the temperature measured by IR-camera. This work could be important for the temperature measurement and heat load study on the first wall of EAST device.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号