首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The paper presents results of an investigation conducted to study the impact resistance of steel fibre reinforced concrete containing fibres of mixed aspect ratio. An experimental investigation was planned in which 108 plain concrete and SFRC beam specimens of size 100 × 100 × 500 mm were tested under impact loading. The specimen incorporated three different volume fractions i.e. 1.0%, 1.5% and 2.0% of corrugated steel fibres. Each volume fraction incorporated mixed steel fibres of size 0.6 × 2.0 × 25 mm and 0.6 × 2.0 × 50 mm in different proportions. The drop weight type impact tests were conducted on the test specimens and the number of blows of the hammer required to induce first visible crack and ultimate failure of the specimen were recorded. The results are presented in terms of number of blows required as well as impact energy at first crack and ultimate failure. It has been observed that concrete containing 100% long fibres at 2.0% volume fraction gave the best performance under impact loading.  相似文献   

2.
This paper presents results of testing 16 specimens, 12 of which as columns under different eccentricities and four as beams under four point loading regime. All 16 specimens were circular in cross section and were made of reinforced concrete. Four specimens served as reference specimens and were just made of reinforced concrete. The next four specimens were wrapped with carbon fibre reinforced polymers (CFRP). The next four specimens had steel fibres added to the concrete. The final four specimens were reinforced with steel fibres and wrapped with CFRP. From each group of specimens, one specimen was tested as a column under a concentric load, the second specimen was tested as a column under 25 mm eccentricity, the third specimen was tested as a column under 50 mm eccentricity, and the final specimen was tested as a beam under four point loading regime. The experimental programme proved that the introduction of fibres as well as wrapping the specimens with FRP improve the properties of concrete, especially its ductility.  相似文献   

3.
Mechanical characteristics of Fibre Reinforced High Performance Concrete (FR-HPC) subjected to high temperatures were experimentally investigated in this paper. Three different concretes were prepared: a normal strength concrete (NSC) and two High Performance Concretes (HPC1 and HPC2). Fibre reinforced concretes were produced by addition of steel or polypropylene fibres in the above mixtures at dosages of 40 kg/m3 and 5 kg/m3, respectively. A total of nine concrete mixtures were produced and fibres were added in six of them. At the age of 120 days specimens were heated to maximum temperatures of 100, 300, 500 and 700 °C. Specimens were then allowed to cool in the furnace and tested for compressive strength, splitting tensile strength, modulus of elasticity and ultrasonic pulse velocity. Reference tests were also performed at air temperature (20 °C). Residual strength of NSC and HPC1 was reduced almost linearly up to 700 °C and 500 °C, respectively whereas the residual strength of HPC2 was sharply reduced up to 300 °C. Explosive spalling was observed on both HPC. Addition of steel fibres increased the residual strength up to 300 °C, but spalling still occurred in HPC1 and HPC2. Such an explosive behavior was not observed when polypropylene fibres were added in the mixtures; however, in this case the residual mechanical characteristics of all concretes were significantly reduced.  相似文献   

4.
It is commonly assumed that when a mix achieves satisfactory performance in Quality Control tests at 28 days this result will translate into satisfactory performance throughout the design life of the corresponding concrete structure. While this is generally true of the compressive strength of concrete it is not necessarily true for other parameters. The post-crack performance of fibre reinforced concrete (FRC) differs from that of conventionally reinforced concrete in that the post-crack performance of fibres is related in a complex manner to the characteristics of the concrete matrix. Age-dependent changes in the characteristics of the concrete matrix can effect changes in the post-crack behaviour of fibres. The present investigation has examined how the post-crack energy absorption of fibre reinforced shotcrete (FRS) changes with aging and has found that some types of fibre exhibit dramatically different performance characteristics at late age compared to that displayed at 28 days. This change can have significant consequences for the design of ground support based on fibre reinforced shotcrete. Tunnel linings required to resist sustained ground stresses, or which may be subject to deformation associated with seismicity or ground movement at later ages, should be designed with consideration of a possible long-term loss of ductility exhibited by some types of fibre reinforced shotcrete.  相似文献   

5.
In this paper, applicability of previously published empirical relations among compressive strength, splitting tensile strength and flexural strength of normal concrete, polypropylene fiber reinforced concrete (PFRC) and glass fiber reinforced concrete (GFRC) to steel fiber reinforced concrete (SFRC) was evaluated; moreover, correlations among these mechanical properties of SFRC were analyzed. For the investigation, a large number of experimental data were collected from published literature, where water/binder ratio (w/b), steel fiber aspect ratio and volume fraction were reported in the general range of 0.25–0.5, 55–80 and 0.5–2.0%, respectively, and specimens were cylinders with size of Φ 150 × 300 mm and prisms with size of 150 × 150 × 500 mm. Results of evaluation on these published empirical relations indicate the inapplicability to SFRC, also confirm the necessity of determination on correlations among mechanical properties of SFRC. Through the regression analysis on the experimental data collected, power relations with coefficients of determination of 0.94 and 0.90 are obtained for SFRC between compressive strength and splitting tensile strength, and between splitting tensile strength and flexural strength, respectively.  相似文献   

6.
Tensile strain hardening and multiple cracking behaviours of fibre reinforced cementitious composites containing different hybrid combinations of steel (ST) and polyethylene (PE) fibres are reported. Various hybrid combinations of ST and PE fibres of 12 mm length are studied. Different hybrid combinations of ST and PE fibres of 18 mm length are also studied here. The effects of addition of different types of sands of different contents on the strain hardening behaviour are also evaluated. PE fibres are found to improve the tensile strain capacity of hybrid fibre composites whereas ST fibres contributed on the improvement of ultimate tensile strength of hybrid fibre composites. By increasing the length of PE fibres by 1.5 times significant increase in tensile strain capacity as well as improvement in strain hardening and multiple cracking behaviour of hybrid fibre composites is observed. The addition of sand adversely affected the strain hardening and multiple cracking behaviour of hybrid fibre composites with reduction in tensile strain capacity.  相似文献   

7.
The aim of this paper is primarily experimental and is intended to analyse the behaviour of two cementitious materials, before and after heat treatment: one unreinforced (i.e. without fibres) and the other reinforced (with polypropylene fibres).At room temperature and after heating up to 500 °C, the bending strength is improved by the presences of fibres. The residual young modulus is slightly higher for the fibres reinforced samples.As the temperature increases, the strength gain due to fibres inclusion is reduced. Beyond 500 °C, the bending strength is lower for the fibre reinforced cementitious material compared to those without fibres. Fracture energy is also improved for the fibre mortars at room temperature. At 400 °C this improvement decreases gradually with the introduction of polypropylene fibres. Beyond this temperature and due to the introduction of polypropylene fibres, the fracture energy is reduced.Another test is developed: rapid heating due to exposure to a flame. The temperature in the front side reaches in few seconds 1000 °C. At this temperature and after one hour of exposure, the opposite side reached 140 °C. After cooling, the punching shear strength of the fibre mortar is definitely weaker than of the mortar without fibre.  相似文献   

8.
An experimental study was conducted on high strength mortar reinforced with steel fibres and hybrid fibres consisting of steel fibre, palm fibre and synthetic fibre (Barchip). The inclusion of fibres was maintained at a volumetric fraction of 2%. The compressive strength, splitting tensile strength, static modulus of elasticity, shrinkage, flexural strength, and flexural toughness were determined to study the effect of the hybrid fibres on the properties of high strength cement mortar (HSCM). The results showed that hybridization of fibres in the quantities 1.5% steel fibres + 0.25% palm fibres + 0.25% Barchip fibres, improved the compressive strength and flexural toughness significantly, and also enhanced the splitting tensile strength and flexural strength of the mortar by about 44% and 140%, respectively.  相似文献   

9.
This research discusses the effects of both steel fibre and matrix strengths on fracture energy of high-strength concrete. The variables of experimental study were water/cement ratio, steel fibre strength and steel fibre volume fraction. The water/cement ratios of 0.35, 0.45 and 0.55, and steel fibres with a tensile strengths of 1100 and 2000 MPa were used and volume fractions of steel fibre were 0.33%, 0.67% and 1%. Mechanical properties, fracture energy and characteristic length of concretes were investigated.Significant influences of matrix and fibre tensile strengths on the fracture energy and the characteristic length are noted.  相似文献   

10.
The bond strength of reinforcing bars embedded in full-scale heavily reinforced concrete sections made with industrial self-consolidating concrete (SCC) was investigated and compared with that of normal concrete (NC). The flowability of SCC mix through the dense reinforcement was visually monitored from a transparent formwork. The bond stress was tested for bars located at three different heights (150 mm, 510 mm, and 870 mm from the bottom of the pullout specimens) and at different tested ages (1, 3, 7, 14, and 28 days). The bond stress-free end slip relationship, the top bar effect and the effect of age on bond stress was investigated in both SCC and NC pullout specimens. Bond stresses predicted based on some major codes were compared with those obtained from experiments. The results indicated that casting SCC was much faster and easier and could be done with less labor effort and no concrete blockage among the heavy reinforcements compared to NC. The results also indicated that the bond stress was slightly higher in the SCC pullout specimen compared to the NC pullout specimen. The difference was more pronounced in the top bars and at 28 days of testing.  相似文献   

11.
Permeability is one of the most important parameters to quantify the durability of high-performance concrete. Permeability is closely related with the spalling phenomenon in concrete at elevated temperature. This parameter is commonly measured on non-thermally damaged specimens. This paper presents the results of an experimental investigation carried out to study the effect of elevated temperature on the permeability of high-performance concrete. For this purpose, three types of concrete mixtures were prepared: (i) control high-performance concrete; (ii) high-performance concrete incorporating polypropylene fibres; and (iii) high-performance concrete made with lightweight aggregates. A heating–cooling cycle was applied on 160 × 320 mm, 110 × 220 mm, and 150 × 300 mm cylindrical specimens. The maximum test temperature was kept as either 200 or 600 °C. After the thermal treatment, 65 mm thick slices were cut from each cylinder and dried prior to being subjected to permeability test. Results of thermal gradients in the concrete specimens during the heating–cooling cycles, compressive strength, and splitting tensile strength of concrete mixtures are also presented here. A relationship between the thermal damage indicators and permeability is presented.  相似文献   

12.
In general, the addition of fibers in concrete mix significantly improves many of the engineering properties of concrete. On the other hand, steel fibers reduce the workability of concrete. This paper presents the effect of steel-fiber length (aspect ratio) and content on bleeding of steel fiber reinforced concrete (SFRC). Two different steel fiber types (both is hooked-end) were used at a ratio of 0% (control), 0.3%, 0.64%, 1% and 1.3% by volume. Slump, Ve-Be test, air content and unit weight were determined experimentally. Specimens were poured in the standard moulds and the bleeding water content was measured 30 min, 60 min, 90 min, 120 min, 150 min and 180 min after starting the test. The results indicated that the workability of concrete significantly reduced as the fiber dosage rate increases. This was assessed through standard slump test and Ve-Be consistometer test. The bleeding water content was increased by increase of the fiber volume fraction and fiber aspect ratio according to experimental results. Also, a bleeding coefficient value for SFRC made with and without steel fiber was proposed as a result of this study.  相似文献   

13.
The strengthening of reinforced concrete structures with externally bonded fibre reinforced polymer (FRP) laminates has shown excellent performance and, as a result, this technology is rapidly replacing steel plate bonding techniques. The numerous studies that have been carried out to date on FRP-strengthened concrete elements have mainly focussed on the static and short-term responses; very little work has been done regarding the long-term performance. This paper addresses this issue, and presents results from a series of experiments on the time-dependent behaviour of carbon FRP-strengthened concrete beams. Twenty-six reinforced concrete beams with dimensions 100 × 150 × 1800 mm, with and without bonded CFRP laminates, were investigated for their creep behaviour. Different reinforcement ratios were used to evaluate the contribution of the external reinforcement on the creep resistance of the beams. High levels of sustained load were used in order to determine the maximum sustained load that can be applied without any risk of creep failure. The applied sustained loads varied from 59% to 78% of the ultimate static capacities of the un-strengthened beams. For most of the long-term tests, the applied sustained loads were higher than the service loads. This was done to account for the fact that strengthening is typically required when a structure is expected to carry increased service loads. The main parameters of this study were (i) the level of sustained load and (ii) the strengthening scheme. The results confirm that FRP strengthening is effective for increasing the ultimate capacities of the beams; however, there is virtually no improvement in performance with regard to the long-term deflections.  相似文献   

14.
The influence of fibrous additives of non-hydrophilized and hydrophilized carbon, polypropene, basalt and kaoline fibre on properties of aerated autoclaved concrete (AAC) forming mixture, as well as on properties of final product was investigated.All these fibrous additives, both non-hydrophilized and hydrophilized, have effect on fluidity and swelling of forming mixtures and increase plastic strength. Along with growing content of each fibrous additive within limits from 0.1% to 0.4% of mass of solid components, the fluidity and swelling of forming mixtures decreases, while the plastic strength increases.All investigated fibrous additives, both hydrophilized and non-hydrophilized, increase the compression- and flexural strengths of AAC. The optimal content of all fibrous additives to be added for obtaining of greatest compression- and flexural strengths is 0.3% counting of dry material in the forming mixture. By capacity to increase the compression- and binding strengths, the fibrous additives may be lined up in the following order: carbon fibre > polypropene fibre > basalt fibre > kaoline fibre. All fibrous additives increase flexural strength more than that of compression. Hydrophilized fibres increase compression- and flexural strengths of concrete more than the respective non-hydrophilized ones.Basing on the results of investigations performed as to fibre-reinforced AAC structure by scanning electron microscope, as well as on the results of earlier performed investigations with fibres used for reinforcement to find out their chemical resistance to treatment of them in the autoclave by alkaline solutions, the pH value of which corresponds to that of hardening alkaline binding medium of concretes, the influence of properties of fibrous additives on efficiency of reinforcement was explained.  相似文献   

15.
An experimental program was conducted to determine an appropriate length of strain gage for use in testing limestone and granite aggregate concretes. Variables in the test program included type and size of aggregate, and length of strain gage. Test specimens consisted of concrete cylinders fitted with a mechanical dial gage, and with multiple electrical resistance strain gages ranging from 120 mm (4.7 in.) to 5 mm (0.2 in.) in length. Cylinders were subjected to compression loading. Strains reported by the strain gages were compared to the strains calculated using dial gage readings. Recommendations are given for appropriate length of strain gages to be used with limestone aggregate and granite aggregate concretes.  相似文献   

16.
The concrete filled steel tubular (CFST) members become very popular in the construction industry and, at the same time, aging of structures and member deterioration are often reported. The actions like implementation of new materials and strengthening techniques become essential to combat this problem. This research work aimed to investigate the structural improvements of CFST sections with normal strength concrete externally bonded with fibre reinforced polymer (FRP) composites. For this study, compact mild steel tubes were used with the main variable being FRP characteristics. Carbon fibre reinforced polymer (CFRP) fabrics were used as horizontal strips (lateral ties) with several other parameters such as the number of layers, width and spacing of strips. Among thirty specimens, twenty seven were externally bonded with 50 mm width of CFRP strips with a spacing of 20 mm, 30 mm and 40 mm and the remaining three specimens were unbonded. Experiments were undertaken until column failure to fully understand the influence of FRP characteristics on the compressive behaviour of square CFST sections including their failure modes, axial stress–strain behaviour, and load carrying capapcity. From the test results, it was found that the external bonding of CFRP strips provides external confinement pressure effectively and delays the local buckling of steel tube and also improves the load carrying capacity further. Finally, an analytical model was proposed herein for predicting the axial load carrying capacity of strengthened CFST sections under compression.  相似文献   

17.
This experimental work examines the bond strength between reinforcement steel and concrete, and the top-bar effect in self-compacting concretes. Eight different concretes were used, four self-compacting (SCC) and four normally-vibrated (NVC). Tests were conducted on 200 mm cube specimens and 1500 mm high columns. It was found that, at moderate load levels, SCC performed with more stiffness, which resulted in greater mean bond stresses. The ultimate bond stresses are also somewhat greater although, due probably to the negative effects of the bleeding having less impact on failure, the differences between SCC and NVC are reduced considerably, and even disappear completely for concretes of more than 50 MPa. On the other hand, the top-bar effect is much less marked in SCC, and therefore a change in the factor that takes into account this effect in the formulas used for calculating the anchorage length of the reinforcement is proposed for these concretes.  相似文献   

18.
This paper presents the results of the first phase of a study on the effect of the confinement provided by transverse carbon fiber reinforced polymer (CFRP) sheets on the fatigue bond strength of steel reinforcing bars in concrete beams. Reinforced concrete bond-beams 150 × 250 × 2000 mm were tested. The variables examined were the area of the CFRP sheets (none or one U-wrap CFRP sheet), the reinforcing bar diameter (20 or 25 mm) and the load range applied to the specimens. The results showed that increasing the bar diameter increased the fatigue bond strength for the unwrapped beams. The CFRP sheets increased the bond strength of the bond-beams with 20 mm bars. However, for the beams with 25 mm steel bars the failure mode changed from a bond splitting failure for the unwrapped beams to a diagonal shear failure for the CFRP wrapped beams, and there was little increase in fatigue strength. Finally, the bond failure mechanism for repeated loading is described.  相似文献   

19.
Rehabilitation and strengthening of concrete structures with externally bonded fibre reinforced polymers (FRPs) has been a viable technique for at least a decade. An interesting and useful application is strengthening of slabs or walls where openings are introduced. In these situations, FRP sheets are very suitable; not only because of their strength, but also due to that they are easy to apply in comparison to traditional steel girders or other lintel systems. Even though many benefits have been shown by strengthening openings with FRPs not much research have been presented in the literature.In this paper, laboratory tests on 11 slabs with openings, loaded with a distributed load are presented together with analytical and numerical evaluations. Six slabs with openings have been strengthened with carbon fibre reinforced polymers (CFRPs) sheets. These slabs are compared with traditionally steel reinforced slabs, both with (four slabs) and without openings (one slab). The slabs are quadratic with a side length of 2.6 m and a thickness of 100 mm. Two different sizes of openings are used, 0.85 × 0.85 m and 1.2 × 1.2 m.The results from the tests show that slabs with openings can be strengthened with externally bonded CFRP sheets. The performance is even better than for traditionally steel reinforced slabs. The numerical and analytical evaluations show good agreement with the experimental results.  相似文献   

20.
Four types of superplasticizers were used in conjunction with three types of silica fume to prepare cement concrete slab specimens that were utilized to measure plastic shrinkage strain and time to attain maximum strain. The concrete slab specimens were cast and placed in an exposure chamber in which the relative humidity, temperature, and wind velocity were kept at 35 ± 5%, 45 ± 2 °C, and 15 ± 2 km/h, respectively. Results of this investigation indicate that the plastic shrinkage strain varied with the type of superplasticizer and the type of silica fume. Maximum plastic shrinkage strain was measured in the undensified silica fume cement concrete with all superplasticizers. Incompatibility was noted between polycarboxylic ether superplasticizer and plain and two types of silica fume cement concretes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号