In this paper, applicability of previously published empirical relations among compressive strength, splitting tensile strength and flexural strength of normal concrete, polypropylene fiber reinforced concrete (PFRC) and glass fiber reinforced concrete (GFRC) to steel fiber reinforced concrete (SFRC) was evaluated; moreover, correlations among these mechanical properties of SFRC were analyzed. For the investigation, a large number of experimental data were collected from published literature, where water/binder ratio (w/b), steel fiber aspect ratio and volume fraction were reported in the general range of 0.25–0.5, 55–80 and 0.5–2.0%, respectively, and specimens were cylinders with size of Φ 150 × 300 mm and prisms with size of 150 × 150 × 500 mm. Results of evaluation on these published empirical relations indicate the inapplicability to SFRC, also confirm the necessity of determination on correlations among mechanical properties of SFRC. Through the regression analysis on the experimental data collected, power relations with coefficients of determination of 0.94 and 0.90 are obtained for SFRC between compressive strength and splitting tensile strength, and between splitting tensile strength and flexural strength, respectively.  相似文献   

2.
This paper presents the results of a study on the potential use of petroleum-contaminated soil (PCS) in the manufacturing of concrete blocks. PCS was obtained from Fahud asset area in northern Oman, where contaminated soils are typically transported for treatment. Hollow blocks of size 400 × 200 ×200 mm, widely used in Oman, were manufactured with a mix proportion of 1:2:4:0.8 for cement, coarse aggregate, sand, and water, respectively. The coarse aggregate had a 10 mm maximum aggregate size. PCS was subjected to the toxicity characteristic leaching procedure (TCLP). The chemical analysis of the extract indicated that the concentrations of metals and organic compounds did not exceed the maximum contaminant levels set by USEPA for TCLP extracts. Different mixes were prepared by replacing the sand with PCS with percentages up to 80% by sand weight in the mix. Five different tests were conducted on the concrete blocks: density, compressive strength, absorption, compressive strength of a masonry column, and thermal conductivity. The compressive strength test was conducted after 14 and 28 days of curing. The other tests were performed after 28 days of curing. Results indicated that PCS can be used with a replacement percentage up to 60% to produce concrete blocks meeting the Omani Standard specifications. The results also indicate potential deterioration when more than 60% PCS are used.  相似文献   

3.
This paper focuses on the development of the compressive strength correlation between the individual block, prism and basic wall panel for load bearing interlocking hollow mortarless blocks. The interlocking blocks used were developed by the Housing Research Centre at Universiti Putra Malaysia. The blocks consisted of stretcher, corner and half blocks. Forty individual block units from each type were tested under compression. The compressive strengths of 10 prisms assembled by stacking two stretcher blocks and two half blocks were evaluated. In addition, four wall panels each having a dimension of 1.2 × 1.2 m were assembled and tested under axial compressive loads. The results obtained were compared with those found in bonded masonry. BS 5628 Part 1:1992 were used for predicting of the compressive capacity of the bonded masonry. The interlocking mechanism, crack patterns and failure mechanism of the interlocking masonry specimens are highlighted and discussed.The correlations between the compressive strength of the interlocking masonry individual block (fcb), prism (fcp) and standard panel (fcw) found in this analysis were fcp = 0.47fcb, fcw = 0.83fcp and fcw = 0.39fcb. Test results indicate that the interlocking mechanism and strength of the block in the load-bearing wall was satisfactory.  相似文献   

4.
This paper investigates the spalling properties of high-strength concrete in order to improve the residual compressive strength and spalling resistance in specimens subjected to 3 h of unloading fire conditions. This study consists of three series of experiments with eighteen different specimens varying in fiber type and content, finishing material and simultaneous fiber content and lateral confinement. They were fabricated to a 300 × 300 × 600 mm mock-up size. Results of the fire test showed that the control concrete was explosive, while the specimens that contained more than 0.1 vol% of polypropylene (PP) and polyvinylalcohol (PVA) fibers were prevented from spalling. One specimen, finished by a fire endurance spray, exhibited even more severe spalling than the control concrete. The specimen containing 0.1 vol% of PP fiber and using a confining metal fabric at the same time, showed the most effective spalling resistance; in particular, the residual compressive strength ratio was even higher than that of the control concrete before the fire test. It was demonstrated that adding fibers in concrete prevented the spalling occurrence and confining metal fabric around the main bars of concrete specimens can secure the strength of structures during the conditions of elevated temperature.  相似文献   

5.
In this study, the use of ferrocement as an external confinement to concrete specimens is investigated. The effectiveness of confinement is achieved by comparing the behavior of retrofitted specimens with that of conventional specimens. The primary test variable considered in this study is the concrete compressive strength. All the other parameters, such as size, shape, number of layers of wire mesh, and L/d ratio of the specimens, were kept constant. The sections chosen are circular cylinders with a size of 150 mm × 300 mm and L/d ratio of 6:1. The test results showed that the confined concrete specimens can enhance the ultimate concrete compressive strengths and failure strains.  相似文献   

6.
Permeability is one of the most important parameters to quantify the durability of high-performance concrete. Permeability is closely related with the spalling phenomenon in concrete at elevated temperature. This parameter is commonly measured on non-thermally damaged specimens. This paper presents the results of an experimental investigation carried out to study the effect of elevated temperature on the permeability of high-performance concrete. For this purpose, three types of concrete mixtures were prepared: (i) control high-performance concrete; (ii) high-performance concrete incorporating polypropylene fibres; and (iii) high-performance concrete made with lightweight aggregates. A heating–cooling cycle was applied on 160 × 320 mm, 110 × 220 mm, and 150 × 300 mm cylindrical specimens. The maximum test temperature was kept as either 200 or 600 °C. After the thermal treatment, 65 mm thick slices were cut from each cylinder and dried prior to being subjected to permeability test. Results of thermal gradients in the concrete specimens during the heating–cooling cycles, compressive strength, and splitting tensile strength of concrete mixtures are also presented here. A relationship between the thermal damage indicators and permeability is presented.  相似文献   

7.
This paper presents the results of the first phase of a study on the effect of the confinement provided by transverse carbon fiber reinforced polymer (CFRP) sheets on the fatigue bond strength of steel reinforcing bars in concrete beams. Reinforced concrete bond-beams 150 × 250 × 2000 mm were tested. The variables examined were the area of the CFRP sheets (none or one U-wrap CFRP sheet), the reinforcing bar diameter (20 or 25 mm) and the load range applied to the specimens. The results showed that increasing the bar diameter increased the fatigue bond strength for the unwrapped beams. The CFRP sheets increased the bond strength of the bond-beams with 20 mm bars. However, for the beams with 25 mm steel bars the failure mode changed from a bond splitting failure for the unwrapped beams to a diagonal shear failure for the CFRP wrapped beams, and there was little increase in fatigue strength. Finally, the bond failure mechanism for repeated loading is described.  相似文献   

8.
Crumb rubber concrete (CRC) is made by adding rubber crumbs into conventional concrete. This study undertakes an experimental study on the cubic compressive strength, axial compressive strength, flexural strength and splitting tensile strength of CRC specimens at both ambient temperature 20 °C and low temperature ?25 °C. The flexural stress–strain responses were also recorded. The averaged size of rubber crumbs used in the study is about 1.5 mm. Four levels of rubber contents are investigated, which are 0%, 5%, 10% and 15% by volume, respectively. The mix design aimed at 40 MPa of compressive strength and 100 mm of slump for all the CRC specimens. The results show that CRC increases its magnitude in strengths when temperature decreases, which is similar to the case of conventional concrete, but still exhibits ductility in low temperature. The conclusion from this study is that CRC may be more beneficial in its application in low temperature environments than in ambient temperature environments.  相似文献   

9.
This paper presents an experimental study investigating the behavior of FRP-reinforced concrete bridge deck slabs under concentrated loads. A total of eight full-scale deck slabs measuring 3000-mm long by 2500-mm wide were constructed. The test parameters were: (i) slab thickness (200, 175 and 150 mm); (ii) concrete compressive strength (35–65 MPa); (iii) bottom transverse reinforcement ratio (1.2–0.35%); and (iv) type of reinforcement (GFRP, CFRP, and steel). The slabs were supported on two parallel steel girders and were tested up to failure under monotonic single concentrated load acting on the center of each slab over a contact area of 600 × 250 mm to simulate the footprint of sustained truck wheel load (87.5 kN CL-625 truck). All deck slabs failed in punching shear. The punching capacity of the tested deck slabs ranged from 1.74 to 3.52 times the factored load (Pf) specified by the Canadian Highway Bridge Design Code (CHBDC) CAN/CSA S6-06. Besides, the ACI 440.1R-06 punching strength equation greatly underestimated the capacity of the tested slabs with an average experimental-to-predicted punching capacity ratio (Vexp/Vpred) of 3.17.  相似文献   

10.
The aim of this study is to investigate the influence of using different particle sizes of recycled glass, casting methods and pozzolanic materials in reducing the expansion due to alkali-silica reaction (ASR) of concrete blocks prepared with the use of crushed glass as fine aggregate. In this work, 25 × 25 × 285 mm mortar bar specimens were prepared using conventional wet-mixed and dry-mixed methods. Except for the control mortar bar, all the specimens were prepared by completely replacing river sand with different particle sizes of recycled glass. In addition, the influence of fly ash (PFA) and metakaolin (MK) content on the reduction of ASR expansion was also investigated. The flexural strength of the mortar bar specimens before and after they had been exposed to 1N NaOH solution was determined to complement the results of ASR expansion test. SEM was performed to examine the microstructure as well as nature of the cement binder-glass interfacial zone. The results reveal that ASR expansion reduced with reducing particle size of glass used. For the same given mix proportion, the dry-mixed method resulted in 44% less expansion when compared with the wet-mixed method. Both PFA and MK were demonstrated to be able to significantly reduce ASR expansion of the concrete glass blocks.  相似文献   

11.
In this study, the mechanical performance of lightweight concrete exposed to high temperature has been modeled using genetic programming. The mixes incorporating 0%, 10%, 20% and 30% silica fumes were prepared. Two different cement contents (400 and 500 kg/m3) were used in this study. After being heated to temperatures of 20 °C, 200 °C, 400 °C and 800 °C, respectively, the compressive and splitting tensile strength of lightweight concrete was tested. Empirical genetic programming based equations for compressive and splitting tensile strength were obtained in terms of temperature (T), cement content (C), silica fume content (SF), pumice aggregate content (A), water/cement ratio (W/C) and super plasticizer content (SP). Proposed genetic programming based equations are observed to be quite accurate as compared to experimental results.  相似文献   

12.
This paper presents the results of an experimental program to investigate the effect of high temperature on the performance of concrete externally confined with FRP sheets. For this purpose, a two-phase experimental program was conducted. In the first phase, 42 standard 100 × 200 mm concrete cylinders were prepared. Out of these specimens, 14 cylinders were left unwrapped; 14 specimens were wrapped with one layer of CFRP sheet; and the remaining 14 specimens were wrapped with one layer of GFRP sheet. Some of the unconfined and FRP-confined specimens were exposed to room temperature; whereas, other cylinders were exposed to heating regime of 100 °C and 200 °C for a period of 1, 2 or 3 h. After high temperature exposure, specimens were tested under uniaxial compression till failure. The test results demonstrated that at a temperature of 100 °C (a little more than the glass transition temperature (Tg) of the epoxy resin), both CFRP- and GFRP-wrapped specimens experienced small loss in strength resulting from melting of epoxy. This loss of strength was more pronounced when the temperature reached 200 °C. In the second phase of the experimental program, three 100 × 100 × 650 mm concrete prisms were prepared and then overlaid by one layer of CFRP and GFRP laminates for conducting pull-off strength tests as per ASTM D4541 – 09. The objective of this testing was to evaluate the degradation in bond strength between FRP and concrete substrate when exposed to elevated temperature environments. One prism was exposed to room temperature whereas the other two specimens were exposed to heating regime of 100 °C and 200 °C for a period of 3 h. It was concluded that a significant degradation in the bond strength occurred at a temperature of 200 °C especially for CFRP-overlaid specimens.  相似文献   

13.
The paper presents results of an investigation conducted to study the impact resistance of steel fibre reinforced concrete containing fibres of mixed aspect ratio. An experimental investigation was planned in which 108 plain concrete and SFRC beam specimens of size 100 × 100 × 500 mm were tested under impact loading. The specimen incorporated three different volume fractions i.e. 1.0%, 1.5% and 2.0% of corrugated steel fibres. Each volume fraction incorporated mixed steel fibres of size 0.6 × 2.0 × 25 mm and 0.6 × 2.0 × 50 mm in different proportions. The drop weight type impact tests were conducted on the test specimens and the number of blows of the hammer required to induce first visible crack and ultimate failure of the specimen were recorded. The results are presented in terms of number of blows required as well as impact energy at first crack and ultimate failure. It has been observed that concrete containing 100% long fibres at 2.0% volume fraction gave the best performance under impact loading.  相似文献   

14.
Multiaxial tensile–compressive tests were performed on 100 mm × 100 mm × 100 mm cubic specimens of plain high-performance concrete (HPC) at all kinds of stress ratios after exposure to normal and high temperatures of 20, 200, 300, 400, 500, and 600 °C, using a large static–dynamic true triaxial machine. Friction-reducing pads were three layers of plastic membrane with glycerine in-between for the compressive loading plane; the tensile loading planes of concrete samples were processed by attrition machine, and then the samples were glued-up with the loading plate with structural glue. The failure mode characteristic of specimens and the direction of the crack were observed and described, respectively. The three principally static strengths in the corresponding stress state were measured. The influence of the temperatures, stress ratios, and stress states on the triaxial strengths of HPC after exposure to high temperatures were also analyzed respectively. The experimental results showed that the uniaxial compressive strength of plain HPC after exposure to high temperatures does not decrease completely with the increase in temperature, the ratios of the triaxial to its uniaxial compressive strength depend on brittleness–stiffness of HPC after different high temperatures besides the stress states and stress ratios. On this basis, the formula of a new failure criterion with the temperature parameters under multiaxial tensile–compressive stress states for plain HPC is proposed. This study is helpful to reveal the multiaxial mechanical properties of HPC structure enduring high temperatures, and provides the experimental and theory foundations (testing data and correlated formula) for fire-resistant structural design, and for structural safety assessment and maintenance after fire.  相似文献   

15.
The experiments were performed for assessing the influence of cyclic thermal loading on the shear strength of reinforced concrete (RC) beam specimens. One hundred eleven RC beams of 100 × 150 × 1200 mm size reinforced in tension zone with two bars of 8, 10 and 12 mm diameters were tested under four point loading. The beams were subjected to a number of thermal cycles varying from 7 to 28 cycles with peak temperature taken as 100, 200 and 300 °C. The effects of thermal cycles on the crack pattern, failure mechanism, first crack load and the shear strength of beams have been discussed. The shear strength of the beams has been found to increase by up to 10% at lower temperature cycles of 100 and 200 °C but reduces by up to 14% at higher temperature (300 °C) depending on the severity of thermal loading. The results of study emphasize the need for developing appropriate guidelines for the design of RC structural elements used in comparatively high temperature environment with cyclic thermal loading conditions.  相似文献   

16.
This paper presents the design of concrete mixes made with used-foundry (UFS) sand as partial replacement of fine aggregates. Various mechanical properties are evaluated (compressive strength, and split-tensile strength). Durability of the concrete regarding resistance to chloride penetration, and carbonation is also evaluated. Test results indicate that industrial by-products can produce concrete with sufficient strength and durability to replace normal concrete. Compressive strength, and split-tensile strength, was determined at 28, 90 and 365 days along with carbonation and rapid chloride penetration resistance at 90 and 365 days. Comparative strength development of foundry sand mixes in relation to the control mix i.e. mix without foundry sand was observed. The maximum carbonation depth in natural environment, for mixes containing foundry sand never exceeded 2.5 mm at 90 days and 5 mm at 365 days. The RCPT values, as per ASTM C 1202-97, were less than 750 coulombs at 90 days and 500 coulombs at 365 days which comes under very low category. Thereby, indicating effective use of foundry sand as an alternate material, as partial replacement of fine aggregates in concrete. Micro-structural investigations of control mix and mixes with various percentages of foundry sand were also performed using XRD and SEM techniques. The micro-structural investigations shed some light on the nature of variation in strength at the different replacements of fine aggregates with foundry sand, in concrete.  相似文献   

17.
The depletion of non-renewable resources has become an alarming issue nowadays. Many environmentalists and researchers have been investigating the use of waste materials as a renewable resource for use especially as raw materials in construction. This paper reports on the potential use of waste rice husk ash (RHA) and expanded polystyrene (EPS) beads in producing lightweight concrete bricks. The RHA was used as a cementitious material since it is a lightweight reactive pozzolanic material. RHA was used as partial cement replacement, while the EPS was used as partial aggregate replacement in the mixes. Bricks of 215 mm × 102.5 mm × 65 mm in size were prepared in this study. The engineering properties of the bricks were investigated. Among the properties studied were hardened concrete density, compressive strength and water absorption of the EPS RHA concrete bricks. Scanning electron microscopy (SEM) analysis was also performed on the brick samples. Four types of curing conditions were employed in this study. These include full water curing, air dry curing, 3-day curing and 7-day curing. It was found that the properties of the bricks are mainly influenced by the content of EPS and RHA in the mix and also the curing condition used.  相似文献   

18.
An experimental study was conducted to evaluate the effect of concrete aggregate gradation, water–cement ratio, and curing time on measured ultrasonic wave velocity (UPV). 30 × 30 × 10 cm Portland cement concrete slabs were cast for ultrasonic evaluation, while 10 cm diameter by 20 cm height cylinders were cast for compressive strength evaluation The slabs and cylinders were prepared using Portland cement and limestone aggregate. Two slabs were cast from each combination of coarse aggregate gradations and water cement ratio (0.40, 0.45, 0.50, and 0.55). Four ASTM gradations were considered, ASTM No: 8, 67, 56, and 4. These gradations have nominal maximum aggregate size 25, 4.75, 19.3, and 12.5 mm, respectively.The ultrasonic equipment used in this study was the portable ultrasonic non-destructive digital indicating tester (PUNDIT) with a generator having an amplitude of 500 V producing 54 kHz waves. The time needed to transfer the signal between the transducers was recorded and used to calculate the signal velocity, which was used as a parameter in the evaluation. Ultrasonic measurements were performed at 3, 7, 28, and 90 days after concrete casting.The results of the analysis indicated that water–cement ratio was found to have a significant effect on UPV. The UPV was found to decrease with the increase of water cement ratio. Aggregate gradation was also found to have significant effect on UPV. In general, the larger the aggregate size used in preparing Portland cement concrete, the higher the measured velocity of ultrasonic waves. Also, UPV was found to be increased as concrete curing time increased. Concrete compressive strength was found to be significantly affected by water–cement ratio and coarse aggregate gradation. Lower water–cement ratio produced higher concrete strength. Also, the concrete compressive strength increased as maximum aggregate size decreased.  相似文献   

19.
A new generation of concrete, ultra-high performance fibre reinforced concrete (UHPFRC) has been developed for its outstanding mechanical performance and shows a very promising future in construction applications. In this paper, several possibilities are examined for reducing the price of producing UHPFRC and for bringing UHPFRC away from solely precast applications and onto the construction site as an in situ material. Recycled glass cullet and two types of local natural sand were examined as replacement materials for the more expensive silica sand normally used to produce UHPFRC. In addition, curing of UHPFRC cubes and prisms at 20 °C and 90 °C has been investigated to determine differences in both mechanical and ductility.The results showed that using more angular sand particles reduces the flowability of fresh UHPFRC. The local natural sand can produce a similar mechanical and ductility of UHPFRC to the silica sand. However the use of Recycled Glass Cullet (RGC) gives approximately 15% lower performance, i.e. flexural strength, compressive strength and fracture energy. Specimens cured at 20 °C give approximately 20% lower compressive strength, 10% lower flexural strength and 15% lower fracture energy than specimens cured at 90 °C from 1 to 7 days.  相似文献   

20.
This study aims to investigate the efficiency of waste tyre rubber-filled concrete to improve the deformability and energy absorption capacity of RC columns by considering different concrete compressive strength, size of waste tyre rubber particles and rubber content. Twelve column specimens were tested using concrete of compressive strength 24 and 28 MPa mixed with 0.6 and 1 mm tyre rubber particles. For each concrete batch, 27 control specimens were prepared to examine the concrete properties. Using waste tyre rubber-filled concrete leads to a slightly lower compressive strength and modulus of elasticity, but the curvature ductility can increase up to 90%. It is concluded that this type of concrete can offer good energy dissipation capacity and ductility, which makes it suitable for seismic applications.  相似文献   