首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Photovoltaic (PV) panel overheating drastically reduces their efficiency and lifespan. Overheating also has the potential to form electric arcs which can melt metal fixtures and burn away the module’s insulating materials. Due to these phenomena, the introduction of water-cooling or, more generally, liquid-cooling systems inside the PV panel appears reasonable. Hollow fibre cooling system consisting of plastic tubes of a small diameter (less than 1 mm) was tested as a simple solution. Fibres can be placed in contact with the back surface of a PV panel and coolant flowing through provides efficient and uniform cooling. Heat removed from the panel may be used for domestic or industrial needs or released to the surroundings. Hollow fibres have very thin walls (about 0.1 mm) to transfer heat easily, and the system is light, compact and resistant to corrosion. Experiments confirmed that such system can cool the PV panel, removing up to 1 kW of heat and lowering the module temperature from 90°C to about 50°C. It was observed that cooling improves the electric efficiency of PV cells by about 50%.  相似文献   

2.
The paper deals with a passive air‐based cooling technique of photovoltaic (PV) panels in operating conditions. Cooling technique is done by specific type of using aluminium fins, and its main purpose is to increase the electrical efficiency of the PV panel. An increase in electrical efficiency can be achieved because of temperature degradation effect, where the PV panel yields less power at higher operating temperatures (the PV panel's efficiency can drop by up to 0.5%/°C). To confirm a cooling technique, a medium‐sized PV system was used in a 2‐month experiment. The experiment was done in realistic operating conditions, and all working parameters were thoroughly measured. After the analysis of the data, no significant raise in electrical efficiency was recorded throughout the experiment. A numerical approach was conducted, based on gained experimental data. Developed numerical model gave explanations of experimental results and provided an insight in heat flow through the PV cell. Later on, developed numerical model was used to propose new cooling variations of the fin‐based technique and to further examine the overall potential of air based passive cooling techniques. It was shown that cooling effect by up to 5°C is a realistic expectation for this technique in described operating conditions.  相似文献   

3.
Peak electric demand due to cooling load in the Desert Southwest region of the US has been an issue for the electrical energy suppliers. To address this issue, a consortium has been formed between the University of Nevada Las Vegas, Pulte Homes (home builder) and NV Energy (local utility) in order to reduce the peak load by more than 65%. The implemented strategies that were used to accomplish that goal consist of energy efficiency in homes, onsite electricity generation through roof integrated PV, direct load control, and battery storage at the substation level. The simulation models developed using building energy analysis software were validated against measured data. The electrical energy demand for the upgraded home during peak period (1:00–7:00 PM) decreased by approximately 37% and 9% compared to a code standard home of the same size, due to energy efficiency and PV generation, respectively. The total decrease in electrical demand due to energy efficiency and PV generation during the peak period is 46%. Additionally, a 2.2 °C increase in thermostat temperature from 23.9 °C to 26.1 °C between 4:00 PM and 7:00 PM has further decreased the average demand during the peak period by 69% of demand from a standard home.  相似文献   

4.
Industry and government interest in solar energy has increased in recent years in the Middle East. However, despite high levels of solar irradiance in the Arabian Gulf, harsh climatic conditions adversely affect the electrical performance of solar photovoltaics (PV). The objective of this study is to compare the annual performance characteristics of solar PV modules that utilize either sun-tracking or water cooling to increase electrical power generation relative to that of stationary, passively cooled modules in the Middle East climatic conditions. This is achieved using an electro-thermal model developed and validated against experimental data acquired in this study. The model is used to predict the annual electrical power output of a 140 W PV module in Abu Dhabi (24.43°N, 54.45°E) under four operating conditions: (i) stationary geographical south facing orientation with passive air cooling, (ii) sun-tracked orientation with passive air cooling, (iii) stationary geographical south facing orientation with water cooling at ambient air temperature, and (iv) stationary geographical south facing orientation with water refrigerated at either 10 °C or 20 °C below ambient air temperature. For water cooled modules, annual electrical power output increases by 22% for water at ambient air temperature, and by 28% and 31% for water refrigerated at 10 °C and 20 °C below ambient air temperature, respectively. 80% of the annual output enhancement obtained using water cooling occurs between the months of May and October. Finally, whereas the annual yield enhancement obtained with water cooling at ambient air temperature from May to October is of 18% relative to stationary passive cooling conditions, sun-tracking over the complete year produces an enhancement of only 15% relative to stationary passive cooling conditions.  相似文献   

5.
Passive evaporative cooling has great potential as an alternative to conventional air‐conditioning in arid hot climates because of its low cost and zero pollution. This paper describes a novel evaporative cooling system with an automatic wind‐tracking device to improve its operating efficiency. The design and operating principles are discussed. A mathematical model is simplified by the assumption of convective heat and mass transfer of staggered streamlets of water. A computer program has been developed to calculate the deflection and length of spray water streamlets, as well as evaporative water mass, minimum cooled water temperature and required cooling time. A typical example illustrates that approximately 20 kg water are evaporated and around 26 min are required for 980 kg of water to be cooled from 28°C to the wet bulb temperature of 19.2°C of ambient air in a typical arid hot climate (relative humidity = 0.30, dry bulb temperature = 32°C and wind velocity = 4 m s?1). The application of adsorbents, would allow the evaporative cooling system to be applied in hot, humid climates, in addition to hot climates with low humidity. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

6.
A stand-alone triple basin solar desalination system is experimentally tested and the results are discussed in this paper. This system mainly consists of a triple basin glass solar still (TBSS), cover cooling (CC) arrangement, parabolic dish concentrator (PDC) and photovoltaic (PV) panel. Four triangular hollow fins are attached at the bottom of the upper and middle basin in order to increase the heat transfer rate and place the energy storing materials. The performance of the system is studied by, conventional TBSS system, integrating the TBSS with CC, TBSS with PDC, and TBSS with CC and PDC. Also, each configuration is tested further by using fins without energy storing material, fins filled with river sand, and fins filled with charcoal. The results of the test reveal that, TBSS with charcoal and TBSS with river sand enhance the distillate by 34.2 and 25.6% higher than conventional TBSS distillates. TBSS with cover cooling reduces the glass temperature to about 8 °C compared to the conventional TBSS. The presence of concentrator increases the lower basin water temperature upto 85 °C. The maximum distillate yield of 16.94 kg/m2.day is obtained for TBSS with concentrator, cover cooling and charcoal in fins.  相似文献   

7.
Yasu Zhou  Xun Zhu  Xiao Ding 《传热工程》2018,39(5):460-472
Thermal performance of closed wet cooling tower (CWCT) with packing is analyzed using experiments and numerical simulations. The effect of cooling water flow direction on the performance is discussed. The results show that the packing plays an important role in improving the cooling effect of the CWCT. Under the same operating conditions, the cooling water outlet temperature of CWCT with packing is lower than that of CWCT without packing between 0.6°C and 1.5°C the cooling efficiency of CWCT with packing is higher than that of CWCT without packing between 6.0% and 14.8%. The concurrent cooling water flow direction results in more uniform temperature differences between cooling water and the spray water, which can benefit the cooling water outlet temperature 0.3–0.7°C and the cooling efficiency 3.0–9.5%.  相似文献   

8.
This article presents a combined experimental and modelling study for determining the thermal parameters of spherical produces in immersing cooling. In experiments, large spherically shaped water melons were selected as test samples, and cooled in water at surrounding temperatures of 0·5°C, 1·0°C, and 1·5°C. Inside temperatures of the produces were recorded at these water temperatures. In the analytical part, the models were introduced to determine the thermal parameters involved in the process, such as cooling coefficients, lag factors, heat transfer coefficients, thermal conductivities, thermal diffusivities, Biot numbers as well as the cooling times in terms of half cooling and seven-eighths cooling times. The results indicate that the cooling coefficient, the heat transfer coefficient, the Biot number, and the thermal diffusivity of the produce decreased by 3·2%, 0·42%, 0·42%, and 3%, respectively, with increasing cooling medium temperature. The lag factor increased by 9·3%. The half cooling time and the seven-eights cooling time indicating the cooling rates of the produce increased by respectively 15·01% and 7·56%. One can conclude that the present technique is a useful, simple and effective tool for determining thermal parameters for produces cooled in a fluid medium.  相似文献   

9.
The article presents how to increase electrical efficiency and power output of photovoltaic (PV) panel with the use of a phase change material (PCM). The focus of the work is in experimental setup and simulation heat extraction from the PV panel with the use of TRNSYS software. A modification of PV panel Canadian Solar CS6P-M was made with a phase change material RT28HC. The actual data of cell temperature of a PV panel with and without PCM were given and compared. A simulation of both PV panels in TRNSYS software was performed, followed by the comparison of results with the simulation and experimental actual data. The experimental results show that the maximum temperature difference on the surface of PV panel without PCM was 35.6 °C higher than on a panel with PCM in a period of one day. Referring to experimental results the calculation of the maximum and average increase of electrical efficiency was made for PV-PCM panel with TRNSYS software. Final results of simulation shows that the electricity production of PV-PCM panel for a city of Ljubljana was higher for 7.3% in a period of one year.  相似文献   

10.
Photovoltaic technology provides the direct method to convert solar energy into electricity. Modeling and simulation plays a very important role in the development of PV devices as well as in the design of PV systems. The objective of the current work was to develop a novel thermal model to simulate the thermal performance of PV modules with and without cooling. The model was sequentially coupled with a radiation model and an electrical model to calculate the electrical performance of the PV panels. Using the developed model, various studies were performed to evaluate the electrical and thermal performance of the module under different environmental and operating conditions with and without cooling. Results show that the performance of the PV panel with cooling had very little influence of increasing absorbed radiation (200–1000 W/m2) at a constant ambient temperature (25 °C) and increasing ambient temperature (0–50 °C) at an absorbed radiation of 800 W/m2. For the same variation in conditions, the performance of the panel without any cooling reduced significantly.  相似文献   

11.
One of the main problems that limit the extensive use of photovoltaic (PV) systems is the increase in the temperature of PV panels. Overheating of a PV module decreases the performance of the output power by 0.4% to 0.5% per 1°C over its rated temperature that in most cases is 25°C. An effective way of improving electrical performance (power output and efficiency) and reducing the rate of thermal degradation of a PV module is to reduce the operating temperature of the PV surface by a cooling medium. To achieve this, nanofluids can be considered as a potentially effective solution for cooling. In this study, two types of nanofluids, namely Al2O3 and TiO2 water‐based mixture of different volume flow rates and concentrations (0.01%, 0.05%, and 0.1%) by weight, were used. Also, three PV panels were cooled simultaneously using nanofluids, water, and natural air, respectively. Results showed that nanofluids for cooling enhanced heat transfer rate much better than water and natural air. Best results were achieved for TiO2 nanofluids at the considered concentration (0.1 wt%). Nanofluid cooling of turbulent flows for such an application has not been investigated before. These results represent the first application of nanofluid cooling in the turbulent flow regimes and in outdoor conditions including real solar irradiation.  相似文献   

12.
An experiment has been performed to investigate the cooling performance of a thermoelectric ceiling cooling panel (TE‐CCP). The TE‐CCP was composed of 36 TE modules. The cold side of the TE modules was fixed to an aluminum ceiling panel to cool a test chamber of 4.5 m3 volume, while a copper heat exchanger with circulating cooling water at the hot side of the TE modules was used for heat release. Tests were conducted using various system parameters. It was found that the cooling performance of the system depended on the electrical supply, cooling water temperature and flow rate through the heat exchanger. A suitable condition occurred at 1.5 A of current flow with a corresponding cooling capacity of 289.4 W which gives the coefficient of performance (COP) of 0.75 with an average indoor temperature of 27°C. Using thermal comfort test data in literature for small air movements under radiant cooling ceilings, results from the experiments show that thermal comfort could be obtained with the TE‐CCP system. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

13.
An experiment was performed to simulate a water cooling panel system for decay heat removal from a high-temperature gas-cooled reactor (HTGR) and to investigate the performance of decay heat removal and the temperature distribution for components of the system. The experimental apparatus is composed of a pressure vessel 1 m in diameter and 3 m in height, containing heaters with a maximum heating rate of 100 kW which simulates the decay heat of the reactor core and cooling panels surrounding the pressure vessel. The analytical code THANPACST2 was applied to analyze the experimental data and to investigate the validity of the analytical method and model proposed. Under conditions using helium gas at a pressure of 0.73 MPa and temperature of 210°C in the pressure vessel, temperatures of the pressure vessel were well estimated to within differences of −29 to +37°C compared to the experimental data. The analyses indicate that the heat removed by the cooling panel is 11.4% less than the experimental value and the heat transferred by thermal radiation is 74.4% of the total heating value. It was also found that the lower head of the pressure vessel is effectively cooled by natural convection through the flow channels at the upper and the lower edges of the skirt-type support of the pressure vessel. © 1998 Scripta Technica, Heat Trans Jpn Res, 26(3): 159–175, 1997  相似文献   

14.
The main problem in using photovoltaic (PV) systems is the low energy conversion efficiency of PV cells. The efficiency of PV cells will decrease significantly as the temperature of the cells exceed to a certain limit. In order to increase the efficiency, it is necessary to reduce the operating temperature of array. One of the ways for improving the system operation is cooling PV cells with a thin film of water. The aim of this research is to study the effects of nominal power of array and system head on the operation of system by using this method. For this purpose, a photovoltaic water pumping system is installed in Kerman city (Latitude: 30 ° 17′ and longitude: 57 ° 50′) and different methods examined to reduce PV cells temperature. The most effective way was chosen and used in set. This method is based on providing water for cooling cells by the pump itself. Experiments show that with decreasing of array nominal power and increasing in system head, the power generated by the array increases significantly. This increases the panel and total efficiency and therefore the pump flow rate. This method is ineffective as the array nominal power increases significantly.  相似文献   

15.
The temperature of a photovoltaic (PV) panel has a negative effect on the generated power. As the solar irradiance that falls on the PV increases, the operating PV temperature rises, which leads to a decrease in electrical efficiency. Therefore, there arises a need to introduce a cooling system to minimize PV temperature. In this study, the simple passive cooling method of extending its surfaces with fins was used to reduce the PV temperature. Different numbers of longitudinal aluminum fins were attached to the bottom surface of a PV panel and their effects were examined under realistic weather conditions for Baghdad, Iraq. Results show that the use of the passive cooling method under natural convection will be more effective in reducing PV temperature before solar noon than after solar noon. The maximum power enhancement was about 2.5 W and occurred at solar noon when using 10 aluminum fins. The peak efficiency value of the PV panel with fin cooling was about 15.3% against 14% for the unfinned PV panel.  相似文献   

16.
Waste heat is generally dissipated from process water to atmospheric air in cooling towers. In the present study, a novel design is used to extract more amount of heat without any additional energy input by incorporating secondary ambient air in an induced draft wet cooling tower. In addition, more fresh air is induced in the tower from the rain zone, which increases the effectiveness at any value of the water to air flow rate (L/G ratio). Moreover, tower characteristics, range, and evaporation loss were also increased due to the novel design. It is noteworthy that secondary fresh air increases effectiveness, heat rejection, and tower characteristics by 10.12%, 19.65%, and 26.11%, respectively, and decreases approach by 16.32% at 0.55 L/G ratio, 44°C inlet water temperature, 29.7°C dry bulb temperature, and 18.4°C inlet air wet bulb temperature.  相似文献   

17.
In high concentrating photovoltaic systems, thermal regulation is of great importance to the conversion efficiency and the safety of solar cells. Direct‐contact liquid film cooling technique is an effective way of thermal regulation with low initial investment. Tilt of solar cells is common in concentrating solar systems. An evaluation of direct‐contact liquid film cooling technique behind tilted high concentration photovoltaics was performed using both experimental and computational approaches. In the experiment, deionized water was used as the coolant at the back of simulated solar cells. Solar cell inclination of 0° to 75° with inlet water flow rate of 100–300 L/hour and inlet temperature of 30°C to 75°C were experimentally investigated. A two‐dimensional model was developed using computational fluid dynamics technique and validated by experimental results. The effects of inclination on average temperature, temperature uniformity, and heat transfer coefficient were discovered in this paper. The results indicated that 20° is the optimum angle for liquid film cooling. In addition, optimum inlet width, temperature, and velocity for inclination over 30° are 0.75 mm, 75°C, and 0.855 m/s, respectively.  相似文献   

18.
In this paper, a model to study the effect of inlet air‐cooling on gas turbines power and efficiency is developed for two different cooling techniques, direct mechanical refrigeration and an evaporative water spray cooler. Energy analysis is used to present the performance improvement in terms of power gain ratio and thermal efficiency change factors. Relationships are derived for an open gas turbine cycle with irreversible compression and expansion processes coupled to air‐cooling systems. The obtained results show that the power and efficiency improvements are functions of the ambient conditions and the gas turbine pressure ratio. The performance improvement is calculated for, ambient temperatures from 30 to 50°C, the whole range of humidity ratio (10–100%) and pressure ratio from 8 to 12. For direct mechanical refrigeration air‐cooling, the power improvement is associated with appreciable drop in the thermal efficiency. The maximum power gain can be obtained if the air temperature is reduced to its lowest limit that is the refrigerant evaporation temperature plus the evaporator design temperature difference. Water spray cooling process is sensitive to the ambient relative humidity and is suitable for dry air conditions. The power gain and efficiency enhancement are limited by the wet bulb temperature. The performance of spray evaporative cooler is presented in a dimensionless working graph. The daily performance of the cooling methods is examined for an ABB‐11D5 gas turbine operating under the hot humid conditions of Jeddah, Saudi Arabia. The results indicate that the direct mechanical refrigeration increased the daily power output by 6.77% versus 2.57% for the spray air‐cooling. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

19.
The direct-type solar dryer is characterized by very simple construction, less maintenance, cost-effectiveness, and is easy to handle. The present study aims to enhance the performance of a direct-type solar dryer. To achieve this, the photovoltaic (PV) panels with thermal energy recovery and solar air collector were integrated with the direct-type solar dryer. In this study, the PV panels with thermal energy recovery and solar air collector were utilized as preheating units to raise the air temperature before entering the direct solar dryer. Moreover, the PV panels were utilized to drive the air blower. In this study, three incorporated models are suggested to study the performance of the solar dryer integrated with PV panels with thermal energy recovery and solar air collector. The model of each component was validated by the previously recorded empirical data. The results confirmed that the dual utilization of the PV panels with thermal energy recovery and solar air collector as a preheating unit raised the air temperature entering the direct solar dryer by the rate varying between 29°C and 42°C within the period 9:00 a.m.–4:00 p.m. Also, the moisture content of banana samples inside the direct solar dryer reduced from the initial value of 72% (wb) to the value of 33.4% (wb) within 7 h (9:00 a.m.–4:00 p.m.). During this operating period, moisture removal from the banana samples varied between 110 and 400 g/h.  相似文献   

20.
To overcome the significant amounts of heat generated by large‐capacity battery modules under high‐temperature and rapid‐discharge conditions, a new liquid cooling strategy based on thermal silica plates was designed and developed. The superior thermal conductivity of the thermal silica plate combined with the excellent cooling effect of water led to a feasible and effective composite liquid cooling system during long cycle testing. The experimental results showed that the addition of thermal silica plates can greatly improve the cooling capacity that can allow the maximum temperature difference to be controlled at 6.1°C and reduce the maximum temperature of the battery module by 11.3°C, but still outside the optimum operating temperature range. The water flow significantly enhanced the cooling performance/stability, and slight temperature fluctuations were observed during cycling. The cooling performance obviously improved as the flow rate rose. When the velocity reached a critical value, further increase in water flow rate induced a slight influence on the cooling capacity due to the limitation of the materials. The maximum temperature (Tmax ) could be reduced to 48.7°C, and temperature difference (?T ) could be maintained within 5°C when the water flow velocity increased to 4 mL/s, which was determined as the best value. The energy consumed by the water pump is only 1.37% of the total energy of the battery module. Overall, these findings should provide novel strategies for the design and optimization of battery thermal management system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号