The flow and heat transfer mechanisms of mist/air film cooling are studied in this paper with three hole types under three blowing ratios. The velocity vectors and three-dimensional contours of the vortices are shown in this paper in order to investigate the mist/air cooling characters with different hole types. Both the span averaged and centerline film cooling effectiveness are studied in this paper to compare the cooling performance of three cooling hole types.

Mist/air cooling performances of cylindrical hole, fan-shaped hole, and console hole are studied numerically. Flow structures of mist/air jets are studied. Both centerline and span averaged film cooling effectiveness are studied. Results show that the kidney vortex uplifts the mists further away from the flat plate and the antikidney vortex uplifts the mists near the lateral edge of the hole gradually. Mists enhancement on cooling effectiveness is significantly impaired at a higher blowing ratio in cylindrical hole and fan-shaped hole cases. The cooling effectiveness can maintain a relatively high value at each blowing ratio in console hole cases.  相似文献   


2.
Experimental investigation has been performed to study the film cooling performances of cylindrical holes and laid-back holes on the turbine blade leading edge. Four test models are measured for four blowing ratios to investigate the influences of film hole shape and hole pitch on the film cooling performances Film cooling effectiveness and heat transfer coefficient have been obtained using a transient heat transfer measurement technique with double thermochromic liquid crystals. As the blowing ratio increases, the trajectory of jets deviates to the spanwise direction and lifts off gradually. However, more area can benefit from the film protection under large blowing ratio, while the is also higher. The basic distribution features of heat transfer coefficients are similar for all the four models. Heat transfer coefficient in the region where the jet core flows through is relatively lower, while in the jet edge region is relatively higher. For the models with small hole pitch, the laid-back holes only give better film coverage performance than the cylindrical holes under large blowing ratio. For the models with large hole pitch, the advantage of laid-back holes in film cooling effectiveness is more obvious in the upstream region relative to the cylindrical holes. For the cylindrical hole model and the laid-back hole model with the same hole pitch, heat transfer coefficients are nearly the same with each other under the same blowing ratios. Compared with the models with large hole pitch, the laterally averaged film cooling effectiveness and heat transfer coefficient are larger for the models with small hole pitch because of larger proportion of film covering area and strong heat transfer region.  相似文献   

3.
在平板表面分别开设了圆柱孔、展向扩张孔和收缩扩张孔。对比研究了3种孔型的纯空气气膜冷却和水雾/空气气膜冷却特性。在3种吹风比:0.66、1.04、1.44下展开研究。将圆柱孔的数值计算结果与文献中的实验结果进行对照以验证水雾/空气冷却数值计算方法的正确性。对3种孔型下冷却气体混合物的无量纲速度矢量图和部分水雾颗粒的运动轨迹进行了比较和分析。对3种孔型中心线和展向平均气膜冷却效率进行了比较和分析。结果表明:圆柱孔和展向扩张孔射流形成的肾形涡将水雾颗粒抬离平板表面。收缩扩张孔射流形成的肾形涡增强了水雾颗粒的展向扩散并将靠近孔口两侧区域的水雾颗粒逐渐抬离平板表面。对于圆柱孔和展向扩张孔,其射流形成的肾形涡削弱了水雾颗粒对于展向平均气膜冷却效率的提高作用,收缩扩张孔水雾/空气冷却的展向平均气膜冷却效率在3种吹风比下均大于0.6,当吹风比为1.44时,收缩扩张孔的展向平均气膜冷却效率约为展向扩张孔的2倍,圆柱孔的4倍。2种冷却方式下,在吹风比从1.04增大到1.44时,展向扩张孔中心线气膜冷却效率降低0.3左右,而收缩扩张孔中心线冷却效率的降幅小于0.1。  相似文献   

4.
Abstract

This study explores the effects of crescent ribs mounted in an internal cooling channel on the external adiabatic film cooling performance to evaluate the advantage of crescent ribs in gas turbine blade cooling. Three ribs including a transverse rib, a crescent rib concave to the stream-wise direction, and a crescent rib convex to the stream-wise direction are considered. For a fixed mainstream flow Reynolds number, two cross-flow Reynolds numbers and two blowing ratios are taken into account. The results show that the case with a crescent rib concave to the stream-wise direction provides higher film cooling effectiveness both at the lower cross-flow Reynolds number and at the higher cross-flow Reynolds number with higher blowing ratio while the case with a crescent rib convex to the stream-wise direction performs worst at any condition. It is found that the longitudinal vortices produced by crescent ribs concave to the stream-wise direction can promote the cooling air entering the film hole while that induced by the other crescent ribs are nonbeneficial for the cooling air entering the hole. The results indicated that a lower spiral intensity leads to counter-rotating vortices with lower intensity and thus results in better cooling effectiveness. However, it makes a narrow coverage of the target surface by the coolant, which leads to disadvantages upon the cooling performance. The relative merits among the cases at different cross-flow Reynolds numbers and blowing ratios are investigated based on the dominating mechanism.  相似文献   

5.
An experimental investigation on overall heat transfer performance of a rectangular channel, in which one wall has periodically placed oblique ribs to enhance heat exchange and cylindrical film holes to bleed cooling air, has been carried out in a hot wind tunnel at different mainstream temperatures, hot mainstream Reynolds numbers, coolant Reynolds numbers and blowing ratios. To describe the cooling effect of combined external coolant film with the internal heat convection enhanced by the ribs, the overall cooling effectiveness at the surface exposed in the mainstream with high temperature was calculated by the surface temperatures measured with an infrared thermal imaging system. The total mass flow rate of cooling air through the coolant channel was regulated by a digital mass flow rate controller, and the blowing ratio passing through the total film holes was calculated based on the measurements of another digital-type mass flow meter. The detailed distributions of overall cooling effectiveness show distinctive peaks in heat transfer levels near the film holes, remarkable inner convective heat transfer effect over entire channel surface, and visible conductive heat transfer effect through the channel wall; but only when the coolant Reynolds number is large enough, the oblique rib effect can be detected from the overall cooling effectiveness; and the oblique bleeding hole effect shows the more obvious trend with increasing blowing ratios. Based on the experimental data, the overall cooling effectiveness is correlated as the functions of Rem (Reynolds number of hot mainstream) and Rec (Reynolds number of internal coolant flow at entrance) for the parametric conditions examined.  相似文献   

6.
Three different kinds of coolant chamber configuration for film cooling are proposed to develop the swirling coolant flow at blowing ratios ranging from 0.5 to 2.0. The results show that the difference of film cooling effectiveness for three kinds of coolant chamber configuration is little at low blowing ratio, but the advantage of swirling film cooling becomes obviously with the increase of blowing ratio. When the blowing ratio is 2.0, the jet momentum of original coolant chamber configuration is large and uniform, which leads to the lowest cooling effectiveness due to the formation of a strong kidney vortex. The first coolant chamber configuration has a low jet momentum region at upstream of the film hole, the coolant in this region interacts with high temperature mainstream and bypasses the large jet momentum coolant to attach cooling surface at downstream. The second coolant chamber configuration is sprayed with the structure of unidirectional vortex, which forms a vortex pressing on other vortex, making the coolant in pressed vortex attach surface better, producing the best coverage and the higher film cooling effectiveness.  相似文献   

7.
Film cooling combined with internal impingement cooling is one of the most effective technologies to protect the gas turbine vanes and blades from the hot gas. In this study, conjugate heat transfer CFD study was undertaken for a flat plate with combined film cooling and impingement cooling. An experiment on conjugate heat transfer of a flat plate with combined film and impingement cooling was performed to validate the code. Then the effects of several parameters including Biot number, blowing ratio, film hole shape and impingement hole diameter on the overall cooling effectiveness were numerically studied. The results show that for a specific combined cooling scheme and a given blowing ratio, the coolant potential can be reasonably allocated to the internal and the external cooling to achieve the overall cooling effectiveness. As the blowing ratio increases, the overall cooling effectiveness trends to reach a maximum value. For different film hole geometrical, the maximum values of the overall cooling effectiveness at high blowing ratio approximate to the same value. At a given mass flow rate of coolant, the increase of the impingement hole diameter leads to the reduction of the overall cooling effectiveness.  相似文献   

8.
Film cooling performance about a row of dual-fanned holes with injection angles of 30°, 60 ° and 90° were experimentally investigated at blowing ratios of 1.0 and 2.0. Dual-fanned hole is a novel shaped hole which has both inlet expansion and outlet expansion. A transient thermochromic liquid crystal technique was used to reveal the local values of film cooling effectiveness and heat transfer coefficient. The results show that injection angles have strong influence on the two dimensional distributions of film cooling effectiveness and heat transfer coefficient. For the small injection angle of 30 degree and small blowing ratio of 1.0, there is only a narrow spanwise region covered with film. The increase of injection angle and blowing ratio both leads to the enhanced spanwise film diffusion, but reduced local cooling ability far away from the hole. Injection angles have comprehensive influence on the averaged film cooling effectiveness for various x/d locations. As injection angles are 30 and 60 degree, two bands of high heat transfer coefficients are found in mixing region of the gas and coolant. As injection angle increases to 90 degree, the mixing leads to the enhanced heat transfer region near the film hole. The averaged heat transfer coefficient increases with the increase of injection angle.  相似文献   

9.
Detailed heat transfer measurements were conducted on the endwall surface of a large‐scale low‐speed turbine cascade with single and double row injection on the endwall upstream of leading edge. Local film cooling effectiveness and the heat transfer coefficient with coolant injection were determined at blowing ratios 1.0, 2.0, and 3.0. In conjunction with the previously measured flow field data, the behaviors of endwall film cooling and heat transfer were studied. The results show that endwall film cooling is influenced to a great extent by the secondary flow and the coverage of coolant on the endwall is mainly determined by the blowing ratio. An uncovered triangle‐shaped area with low effectiveness close to pressure side could be observed at a low blowing ratio injection. The averaged effectiveness increases significantly when injecting at medium and high blowing ratios, and uniform coverage of coolant on the endwall could be achieved. The averaged effectiveness could be doubled in the case of double row injection. It was also observed that coolant injection made the overall averaged heat transfer coefficient increase remarkably with blowing ratio. It was proven that film cooling could reduce endwall heat flux markedly. The results illustrate the need to take such facts into account in the design process as the three‐dimensional flow patterns in the vicinity of the endwall, the interactions between the secondary flow and coolant, and the augmentation of heat transfer rate in the case of endwall injection. © 2004 Wiley Periodicals, Inc. Heat Trans Asian Res, 33(3): 141–152, 2004; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.20007  相似文献   

10.
Computations are performed to predict the three-dimensional flow and heat transfer of concave plate that is cooled by two staggered rows of film-cooling jets. This investigation considers two coolant flow orientations: (1) the coolant jets were ejected from a straight-blow supply plenum, so the coolant supply plane is parallel to the entrance plane of the coolant jets; (2) the coolant jets were ejected from the cross-blow supply plenum so the coolant supply plane was normal to the entrance plane of the coolant jets. The effects of numerous film-cooling parameters were investigated, including the mainstream Reynolds number, the angular locations of the two-row injections and the blowing ratio. The mainstream Reynolds number, determined by the diameter of the injection hole as the characteristic length, varied from 3440 to 13,760. The blowing ratio ranged from 0.5 to 2.0 with a fixed density ratio of 1.14. Additionally, two angles of injections, 40° and 42°, from the exit plane of the entrance duct are considered. Results are presented as the surface adiabatic film-cooling effectiveness, the temperature distribution and the velocity vector profile. The formation and trace of counter-rotating vortex pairs that result from the interaction between the mainstream hot gas and the cooling jets was clearly exhibited. The laterally averaged film-cooling effectiveness over the concave surface with a straight-blow plenum is slightly higher than that of a cross-blow plenum at all test blowing ratios. Results of this study demonstrate that the blowing ratio is one of the most significant film-cooling parameters over a concave surface.  相似文献   

11.
In this study, four novel film cooling hole designs, all based on cylindrical holes, are numerically evaluated, and compared with those of a simple cylindrical hole and a laterally-diffused shaped hole. Film cooling effectiveness and surrounding thermal and flow fields are documented for operation with various blowing ratios. It is shown that the two-stage cylindrical hole can improve film cooling effectiveness at higher blowing ratios. The primary hole with two secondary holes can enhance film cooling performance by creating anti-kidney vortex pairs that will weaken jet liftoff caused by the kidney vortex pair that is created by the primary hole. The tri-circular shaped hole provides better film cooling effectiveness values only near the hole, but worse at downstream positions. The two-stage structure for the tri-circular shaped hole provides better film coverage because it changes the flow structure inside the delivery channel and decreases jet penetration into the passage flow.  相似文献   

12.
The film cooling performance of chevron holes with different inclination angles and exit lateral diffusion angles has been studied experimentally and numerically. The inclination angles include 35° and 55°. The exit lateral diffusion angles include 20° and 25°. The film cooling effectiveness, heat transfer coefficient and discharge coefficient were measured on a flat plate model by transient liquid crystal measurement technique under four blowing ratios. The results show that the large inclination angle reduces the film cooling effectiveness. The influence of diffusion angle has two aspects: the large diffusion angle leads to mainstream ingestion and decreases film cooling effectiveness at M=1.0 and 1.5; however, the large diffusion angle increases the film cooling effectiveness at high blowing ratio of 2.0, because the larger hole exit area decreases the normal momentum component of the film jet. The large inclination angle decreases the heat transfer coefficient in the right downstream region at M=0.5 and 1.0. The large diffusion angle enhances the heat transfer in the right downstream of the holes in M=0.5~1.5 conditions. The chevron hole with large inclination angle generally has the highest discharge coefficient.  相似文献   

13.
An experimental investigation of the film cooling performance of louver schemes using Thermochromic Liquid Crystal technique is presented in this paper. The louver scheme allows the cooling flow to pass through a bend and encroach with the blade material (impingement effect), then exit to the outer surface of the aerofoil through the film cooling hole. The cooling performance of the louver scheme was analyzed for blowing ratios ranging from 0.5 to 1.5 and for a density ratio of 0.94. The results showed that the louver scheme enhances the local and the average film cooling effectiveness, and the net heat flux reduction better than other published film hole configurations. The louver scheme also provides a wide extensive spread of the secondary flow over the outer surface, thus enhancing the lateral film cooling performance over the downstream surface area. Moreover, the louver scheme produces a lower heat transfer ratio than other film hole geometries at low and high blowing ratios. As a result, the louver scheme is expected to reduce the gas turbine airfoil’s outer surface temperature by provide superior cooling performance than other film cooling schemes hence increasing the airfoil life time.  相似文献   

14.
Internal channel cooling is employed in advanced gas turbines blade to allow high inlet temperatures so as to achieve high thrust/weight ratios and low specific fuel consumption. The objective of the present work is to study the effect of rib height to the hydraulic diameter ratio on the local heat transfer distributions in a double wall ribbed square channel with 90° continuous attached and 60° V-broken ribs. The effect of detachment of the rib in case of broken ribs on the heat transfer characteristics is also presented. Reynolds number based on duct hydraulic diameter is ranging from 10,000 to 30,000. A thin stainless steel foil of 0.05 mm thickness is used as heater and infrared thermography technique is used to obtain the local temperature distribution on the surface. The images are captured in the periodically fully developed region of the channel. It is observed that the heat transfer augmentations in the channel with 90° continuous attached ribs increase with increase in the rib height to hydraulic diameter ratio (e/D) but only at the cost of the pressure drop across the test section. The enhancements caused by 60° V-broken ribs are higher than those of 90° continuous attached ribs and also result in lower pressure drops. But, with an increase in the rib height, the enhancements are found to decrease in channel with broken ribs. The effect of detachment incase of broken ribs is not distinctly observed. The heat transfer characteristics degraded with increase in the rib height in both attached and detached broken ribbed cases.  相似文献   

15.
李广超  吴冬  张魏  吴超林 《动力工程》2012,32(5):368-372
为了获得吹风比对新型气膜冷却孔冷却效率的影响规律,利用Fluent软件求解Navier-Stokes方程,对吹风比分别为0.5、1.0、1.5和2.0时单入口-双出口孔射流冷却效率进行了数值模拟计算,得到了不同吹风比下的流场和冷却效率.结果表明:吹风比对冷却效率有很大影响;随着吹风比的提高,不同次孔方位角下的冷却效率变化规律也不相同;当次孔方位角γ=30°时,吹风比为1.0时的冷却效率最高;当γ=45°时,冷却效率随着吹风比提高而提高;当γ=60°时,冷却效率随着吹风比提高而降低;在研究高吹风比对气膜冷却效率的影响时,γ=45°最佳.  相似文献   

16.
Measurements of heat transfer coefficient (h) are presented for single jets with streamwise angles of 30°, 60° and 90° with a short but engine representative hole length (L/D=4). The freestream Reynolds number (ReD) is 8563, and the blowing ratio (M) ranges from 0.33 to 2. The results are presented in the form of h/h0 which is the ratio of heat transfer coefficient with film cooling to that without. Both local values and laterally averaged ones are presented, the latter refers to the averaged value across the central hole. The corresponding measurements of effectiveness are presented in a companion paper [C.H.N. Yuen, R.F. Martinez-Botas, Int. J. Heat Mass Transfer, Part I]. In general, only slight variations in h/h0 occurred as the blowing ratio was increased with the single 30° hole, in some contrast to the corresponding effectiveness measurements presented in the companion paper [Yuen and Martinez-Botas, Part I]. The single 60° and 90° jets yielded a smaller heat transfer coefficient than the 30° jet.  相似文献   

17.
Experimental investigations have been carried out to study the effect of combined wedge ribs and winglet type vortex generators (WVGs) on heat transfer and friction loss behaviors for turbulent airflow through a constant heat flux channel. To create a reverse flow in the channel, two types of wedge (right-triangle) ribs are introduced: wedge ribs pointing downstream and pointing upstream. The arrangements of both rib types placed inside the opposite channel walls are in-line and staggered arrays. To generate longitudinal vortex flows through the tested section, two pairs of the WVGs with the attack angle of 60° are mounted on the test channel entrance. The test channel has an aspect ratio, AR = 10 and height, H = 30 mm with a rib height, e/H = 0.2 and rib pitch, P/H = 1.33. The flow rate in terms of Reynolds numbers is based on the inlet hydraulic diameter of the channel ranging from 5000 to 22,000. The presence of the combined ribs and the WVGs shows the significant increase in heat transfer rate and friction loss over the smooth channel. The Nusselt number and friction factor values obtained from combined the ribs and the WVGs are found to be much higher than those from the ribs/WVGs alone. In conjunction with the WVGs, the in-line wedge pointing downstream provides the highest increase in both the heat transfer rate and the friction factor while the staggered wedge pointing upstream yields the best thermal performance.  相似文献   

18.
Experimental tests have been performed to investigate the film cooling performance of converging slot-hole (console) rows on the turbine blade. Film cooling effectiveness of each single hole row is measured under three momentum flux ratios based on the wide-band liquid crystal technique. Measurements of the cooling effectiveness with all the hole rows open are also carried out under two coolant–mainstream flux ratios. Film cooling effectiveness of cylindrical hole rows on the same blade model is measured as a comparison. The results reveal that the trace of jets from both consoles and cylindrical holes is converging on the suction surface and expanding on the pressure surface by the influence of the passage vortex, while the influence of passage vortex on the jets from consoles is weaker. The film coverage area and the film cooling effectiveness of single/multiple console row(s) are much larger than those of single/multiple cylindrical hole row(s). When the console row is discrete and the diffusion angle of the console is not very large, the adjacent jets cannot connect immediately after ejecting out of the holes and the cooling effectiveness in the region between adjacent holes is relatively lower. On the pressure surface, the film cooling effectiveness of console rows increases notably with the increasing of momentum flux ratio or coolant–mainstream flux ratio. But on the suction side, the increase in cooling effectiveness is not very notable for console row film cooling as the coolant flux increases. Moreover, for the film cooling of single console row at the gill region of the suction surface, the jets could lift off from the blade surface because of the convex geometry of the suction surface.  相似文献   

19.
Abstract

Combined with infrared thermography experiments, large-eddy simulation was used for studying trench film cooling on C3X vane model at the mainstream Reynolds number of 2.5?×?105 based on the chord length, and nominal blowing ratios of 0.5 and 1.5. The instantaneous and time-averaged characteristics for trench film cooling were analzyed in detail. Inside the trench, a pair of recirculation vortices promotes the coolant spreading on spanwise direction, mitigates the jet penetration into mainstream, and improves cooling effectiveness. On pressure surface, hairpin vortices play the dominate role in the unsteady flow fields. Downstream of the trench, a streamwise vortex pair corresponding to anti-CRVP (Counter rotating vortex pair) is generated on both sides of hairpin structures, and causes high turbulent fluctuation. On suction surface, the mainstream boundary layer transits from laminar to turbulent flow in the upstream of the coolant exit, and large numbers of small-scale vortices dominate the flow dynamics. Spectrum analysis of pressure signals shows that, on pressure surface, trench and round-hole film cooling both exhibit strong periodicity. On suction surface, randomness is more pronounced. The statistical characteristics of velocity and temperature fluctuations were also discussed in detail. Overall, significant cooling augmentation by trench hole is seen on both the suction and pressure surfaces, especially at high blowing ratio.  相似文献   

20.
不同叶顶结构对燃气透平动叶顶部气膜冷却性能的影响   总被引:2,自引:1,他引:1  
对不同叶顶结构的GE-E3叶片的气膜冷却现象进行了数值研究,比较了三种不同的叶顶结构:平顶、凹槽顶和平顶开槽孔结构在叶顶部的流动和冷却现象,并分析了吹风比对这三种结构的冷却性能的影响。发现凹槽顶和平顶开槽孔在结构上具有相似性;在叶顶开槽后,既降低了射流动量,又降低了顶端泄漏流速,有助于提高冷却效果,同时由于凹槽顶的槽比开槽孔的槽大,冷却气体和燃气在槽内充分混合,使得凹槽顶结构具有最高的冷却效率值和最低的换热系数值,平顶开槽孔结构次之。  相似文献   