首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The rotating basket-paddle dissolution apparatus is a combination of the USP/NF rotating basket and rotating paddle. A comparative dissolution study was performed utilizing this new apparatus and the two USP/NF apparatus at various stirring speeds using non-disintegrating oxalic acid tablets and disintegrating aspirin tablets. The amount of drug released using the new apparatus was significantly higher than the rotating basket but significantly lower than the rotating paddle at each of the stirring speeds studied. The results obtained using this new apparatus were highly reproducible compared to the USP/NF apparatus.  相似文献   

2.
Abstract

The dissolution behaviour of indomethacin from six commercial brands of indomethacin capsules, using the USP rotating basket apparatus and the USP paddle apparatus have been studied. The products showed marked differences in their dissolution profiles. The dissolution rates have been different in different brands, and variation has also been observed depending on the method of testing used. The rotating basket apparatus showed superior discriminating capacity than the paddle method.  相似文献   

3.
Abstract

Four dissolution methods, the rotating basket, the rotating paddle, the rotating basket with paddle and the stationary basket-rotating paddle, were evaluated using capsules and non-disintegrating pellets of salicylic acid. The agitation intensity produced by the rotating basket method was very low and differed significantly throughout the vessel. However, it did not differ significantly at different positions in the stationary basket-rotating paddle method. This method offered considerable advantages and hence appears to be a suitable alternative to the existing compendial methods which have limitations for evaluation of dosage forms which tend to float on the dissolution medium.  相似文献   

4.
Abstract

Hardness, disintegration and dissolution of compressed tablets were assessed by compressing tablets from granulations prepared by dry and wet granulation process of two sections and by composite wet granulation process. Modified USP XVIII apparatus for disintegration, rotating basket apparatus USP XVIII and constant circulation apparatus were employed for measuring dissolution. The constant circulation apparatus was used in the studies as only it proved to be sensitive to reflect the differences in the dissolution rates and was a close analog of physiological situation. Four types of tablets containing acetylsalicylic acid, codeine phosphate and propoxyphene hydrochloride were prepared. Tablets prepared by partial dry and wet granulation process did not show significant differences in the rates of dissolution as compared to those prepared by complete wet granulation process.  相似文献   

5.
Reaching nearly perfect sink conditions is very important in the determination of drug dissolution rates. Many times, the only factor that is taken into consideration in achieving sink conditions is the relation between the drug concentration and its solubility. The analytical conditions of the dissolution assay, as well as the dissolution apparatus, stirring speed, and nature and volume of the dissolution fluid may also influence the dissolution results. The main objective of this work was to study the influence of the stirring rate conditions and of the dissolution apparatus in the diltiazem hydrochloride release from tablets. Diltiazem hydrochloride sustained-release (SR) tablets were tested and the following dissolution parameters were evaluated: t10%, t25%, t50%, dissolution time, mean dissolution time (MDT), and dissolution efficiency (DE) at t120, and at t360. To analyze the release mechanism, several release models were tested, such as Higuchi, zero order, first order, Baker-Lonsdale, Hixson-Crowell, Weibull, and Korsmeyer-Peppas. The similarities between two in vitro dissolution profiles were assessed by the similarity factor f2. The in vitro release kinetics of diltiazem hydrochloride sustained-release tablets were evaluated using the USP 2 (paddle) and USP 4 (flow-through) apparatus.  相似文献   

6.
Abstract

The desirability of good correlations of parameters derived from in vitro dissolution study with parameters derived from in vivo bioavailability study is well established in biopharmaceutics. Reports on several in vitro dissolution apparatus, including the two official USP/NF methods, have appeared in the literature over the years. However, none have been accepted as universal because each apparatus is useful only for the dissolution testing of a specific group of drugs or dosage forms. Comparative dissolution testing was performed using the rotating basket-paddle apparatus and the two official USP/NF apparatus.

A comparative bioavailability study was carried out on four batches of rapidly disintegrating tablets (Formulations A to D) of nitrofurantoin and perphenazine using rabbit as an animal model. Excellent rank order (qualitative) correlations were observed among all combinations of in vitro and in vivo parameters. With the drug nitrofurantoin, an excellent quantitative correlation was found between the dissolution halftime and Cmax or Tmax or AUC. Yet, a repeated run with perphenazine yielded excellent correlation between dissolution halftime and Cmax or Tmax, but poor correlation between dissolution halftime and AUC.  相似文献   

7.
Reaching nearly perfect sink conditions is very important in the determination of drug dissolution rates. Many times, the only factor that is taken into consideration in achieving sink conditions is the relation between the drug concentration and its solubility. The analytical conditions of the dissolution assay, as well as the dissolution apparatus, stirring speed, and nature and volume of the dissolution fluid may also influence the dissolution results. The main objective of this work was to study the influence of the stirring rate conditions and of the dissolution apparatus in the diltiazem hydrochloride release from tablets. Diltiazem hydrochloride sustained-release (SR) tablets were tested and the following dissolution parameters were evaluated: t10%, t25%, t50%, dissolution time, mean dissolution time (MDT), and dissolution efficiency (DE) at t120, and at t360. To analyze the release mechanism, several release models were tested, such as Higuchi, zero order, first order, Baker-Lonsdale, Hixson-Crowell, Weibull, and Korsmeyer-Peppas. The similarities between two in vitro dissolution profiles were assessed by the similarity factor f2. The in vitro release kinetics of diltiazem hydrochloride sustained-release tablets were evaluated using the USP 2 (paddle) and USP 4 (flow-through) apparatus.  相似文献   

8.
The effect of dissolution medium pH on theophylline release from co-compressed matrices composed of a 40% benzyl ester of alginic acid was investigated using both the USP rotating paddle method and a modification of the USP rotating basket method. Release rates for each pH were compared using a measure of the time for approximately 80% release (t80%). Results show release of theophylline from these matrices to be significantly slower at pH 1 than at pH 2 and above. Beyond pH 2, drug release is relatively insensitive to dissolution medium pH but is affected by dissolution method because of the tendency of the alginate to form an adhesive, gel-like layer at pH values higher than four. The drug release characteristics of this polymer, under various pH conditions, make it potentially suitable for use in delayed/controlled release oral delivery systems containing compounds that are acid labile or irritating to the gastric mucosa.  相似文献   

9.
The effect of dissolution medium pH on theophylline release from co-compressed matrices composed of a 40% benzyl ester of alginic acid was investigated using both the USP rotating paddle method and a modification of the USP rotating basket method. Release rates for each pH were compared using a measure of the time for approximately 80% release (t80%). Results show release of theophylline from these matrices to be significantly slower at pH 1 than at pH 2 and above. Beyond pH 2, drug release is relatively insensitive to dissolution medium pH but is affected by dissolution method because of the tendency of the alginate to form an adhesive, gel-like layer at pH values higher than four. The drug release characteristics of this polymer, under various pH conditions, make it potentially suitable for use in delayed/controlled release oral delivery systems containing compounds that are acid labile or irritating to the gastric mucosa.  相似文献   

10.
The in-vitro and in-vivo release of theophylline from an oral sustained release tablet (TheogradR) was studied.

The in-vitro release profiles were determined by means of the rotating basket method, the paddle method and the modified disintegration method, described in the USP XX as apparatus 1, 2 and 3 respectively. Besides a stationary basket-rotating paddle method was used.

It was demonstrated that in the stationary basket-rotating paddle apparatus and in the paddle apparatus at low rotational speeds of the paddle, mild agitation conditions were created. Under these conditions the release of theophylline from the sustained release tablet appeared to be matrix controlled. The leached matrix was found to be structurally very weak. For a matrix type of sustained release tablet this is probably beneficial as it would be less likely to cause accumulation and gastro-intestinal obstruction. In contrast the conditions of agitation in the rotating basket apparatus and in the disintegration apparatus were found to be rather severe. This was partly due to mechanical abrasion of the dosage form caused by the gauze of the basket and the basket-rack respectively, and partly the result of high solvent agitation, especially in the disintegration apparatus. Under these conditions it appeared that the empty matrix of the sustained release tablet eroded during the release process. This was confirmed by the results of studies under non-dissolving circumstances of the drug which showed that in this case only the leached matrix of the sustained release dosage form eroded and not that part of the dosage form from which the drug had not yet been dissolved. The in-vivo absorption appears to relate to the in-vitro release. When the Theograd tablet was taken on an empty stomach, it appeared that the absorption rate could succesfully be simulated by means of the stationary basket-rotating paddle method and the paddle method, both at low rotational speeds of the paddle. It was very likely that in this case the in-vivo release from the sustained release tablet was matrix controlled too. Under these conditions the bioavailability was found to be 65% compared with an oral solution of the drug. In contrast, when the Theograd tablet was taken after a meal, a relative bioavailability of 90% was observed. It was made plausible, that the greatly enhanced bioavailability, observed on postprandial administration of the tablet, was due to partial erosion of the leached matrix. This erosion was caused by the food induced increased motility of the gastro-intestinal tract. Based on the results of this study it is recommended to take TheogradR tablets after a meal.  相似文献   

11.
Abstract

Dissolution studies and a 24 patient randomized double-blind crossover bioavailability study were performed using two commercially-sized batches of an ibuprofen 200 mg tablet formulation (sugar-coated). The batches were equivalent with respect to the USP dissolution test, but differed, particularly from tablet-to-tablet, when a paddle at 50 rpm was substituted, one batch consistently giving a high dissolution and the other consistently giving a low dissolution.

The bioavailability study showed the batches to be bioequivalent, thus prompting an investigation as to why the substitution of a paddle at 50 rpm gave no correlation with bioavailability and should therefore be unsuitable as a standard dissolution test. It was found that soaking tablets in acid prior to using the paddle at 50 rpm (thus simulating more closely the in vivo pH sequence) increased the dissolution rate. The increase is such that the maximum dissolution rate, which also approximates that given by the USP method, is achievable within five minutes, even when the presoak medium is an unbuffered solution of hydrochloric acid at pH 4. A standard presoak procedure was then developed consisting of soaking each tablet for five minutes in 5 ml of USP gastric fluid without pepsin at room temperature and with no agitation. A comprehensive application of this procedure to both batches consistently produced results equivalent to those obtained by the USP method. In particular, there was very little tablet to tablet variation. Studies with formulations of varying bioavailability will be necessary before it can be determined whether this new acid presoak procedure will provide a more meaningful dissolution test compared with the current USP method.  相似文献   

12.
Abstract

Tablet properties of 3 different commercial brands of furosemide tablets from different marufacturers have been investigated. Their dissolution characteristics were determined by using USP rotating basket method and two different pH degrees as the test medium. At pH 4.6 a large variation in the dissolution rate of these brands was observed. The release rate differed from one lot to another.

The effect of methods of tablet processing on furosemide release was also studied. A poor dissolution profile was observed with the tablet prepared by direct compression. The best result was obtained with the wet-granulation and the further study is extended on this process.  相似文献   

13.
Hardness, disintegration and dissolution of compressed tablets were assessed by compressing tablets from granulations prepared by dry and wet granulation process of two sections and by composite wet granulation process. Modified USP XVIII apparatus for disintegration, rotating basket apparatus USP XVIII and constant circulation apparatus were employed for measuring dissolution. The constant circulation apparatus was used in the studies as only it proved to be sensitive to reflect the differences in the dissolution rates and was a close analog of physiological situation. Four types of tablets containing acetylsalicylic acid, codeine phosphate and propoxyphene hydrochloride were prepared. Tablets prepared by partial dry and wet granulation process did not show significant differences in the rates of dissolution as compared to those prepared by complete wet granulation process.  相似文献   

14.
The desirability of good correlations of parameters derived from in vitro dissolution study with parameters derived from in vivo bioavailability study is well established in biopharmaceutics. Reports on several in vitro dissolution apparatus, including the two official USP/NF methods, have appeared in the literature over the years. However, none have been accepted as universal because each apparatus is useful only for the dissolution testing of a specific group of drugs or dosage forms. Comparative dissolution testing was performed using the rotating basket-paddle apparatus and the two official USP/NF apparatus.

A comparative bioavailability study was carried out on four batches of rapidly disintegrating tablets (Formulations A to D) of nitrofurantoin and perphenazine using rabbit as an animal model. Excellent rank order (qualitative) correlations were observed among all combinations of in vitro and in vivo parameters. With the drug nitrofurantoin, an excellent quantitative correlation was found between the dissolution halftime and Cmax or Tmax or AUC. Yet, a repeated run with perphenazine yielded excellent correlation between dissolution halftime and Cmax or Tmax, but poor correlation between dissolution halftime and AUC.  相似文献   

15.
Four dissolution methods, the rotating basket, the rotating paddle, the rotating basket with paddle and the stationary basket-rotating paddle, were evaluated using capsules and non-disintegrating pellets of salicylic acid. The agitation intensity produced by the rotating basket method was very low and differed significantly throughout the vessel. However, it did not differ significantly at different positions in the stationary basket-rotating paddle method. This method offered considerable advantages and hence appears to be a suitable alternative to the existing compendial methods which have limitations for evaluation of dosage forms which tend to float on the dissolution medium.  相似文献   

16.
The in vitro release of ampicillin from 8 brands of ampicillin capsules, using four dissolution apparatus, was determined. These apparatus were the USP dissolution apparatus, the USP paddle stirrer apparatus, the USP disintegration apparatus and the spiral—stirrer apparatus. Significance of the differences in dissolution between brands and between methods were tested. Analysis of variance of the dissolution data showed statistically significant differences between brands and between methods at selected time. The paddle method showed superior discriminating capacity than the other methods. Correlation between the present in vitro data and the previously reported in vivo data, in order to find the apparatus capable to mimic in vivo release of ampicillin from capsules, was also determined.  相似文献   

17.
Abstract

A study has been carried out to investigate the dissolution rate profiles of twelve batches of sugar-coated phenylbutazone tablets belonging to four commercial brands. Using the rotating basket method, significant inter-brand and inter-batch variations in dissolution rates were found. Only two batches of one brand passed the B.P. dissolution limit whilst other batches had percentages dissolution between 0.3 and 58 after 45 min. Batches with poor dissolution characteristics exhibited significant tablet-to-tablet variations in dissolution rates; a finding which was not observed in the relatively fast-dissolving batches. When the paddle method was substituted for the B.P. basket method, the dissolution rates were relatively faster but similar dissolution failure was found. However, the tablet-to-tablet dissolution variability was decreased in some of the batches. The observed differences in dissolution rates of the batches examined were unrelated to their disintegration times. Inspite of the poor dissolution characteristics of most of the batches studied, no apparent chemical degradation was found. It is recommended that when evaluating the dissolution rates of brands of phenylbutazone tablets, a number of batches from each brand should be tested.  相似文献   

18.
Abstract

No official dissolution method exists concerning microparticulate drug delivery systems. The purpose of this work is the evaluation of different dissolution methods commonly used to test the in vitro release behaviour of microparticulate drug delivery systems. The influence of different environmental conditions, as stirring speed, ionic strength and presence of surfactant, on drug release is also evaluated.

Four dissolution methods, based on different equipments (USP dissolution test apparatus, rotating bottle apparatus, shaker incubator, recycling flow through cell), are performed on the same batch of indomethacin loaded poly-D, L-lactide (PDLLA) microspheres prepared by spray drying. The results obtained with the methods tested show the influence of in vitro dissolution method employed and of the environmental conditions on drug release profile.  相似文献   

19.
Abstract

Three enteric coating polymers, cellulose acetate phthalate (CAP), hydroxy propylmethylcellulose phthalate (HP55) and cellulose acetate trimellitate (CAT) were evaluated on two different chemical substrates (soluble and insoluble). Gastric juice resistance was tested by dissolution using USP apparatus (paddle) in Britton buffer at different pH, under sink conditions over 5 hours. It can be said that the resistance of tablets depends on the coating formulation considered and the drug solubility. From our tests it results that CAP is more resistant than CAT for two drugs in intestinal medium and the resistance of HP55 depends on the solubility of the drugs. More, only CAT allows the release in the proximal small intestine for drugs whatever solubiliy.  相似文献   

20.
Abstract

The in vitro dissolution rates of ceftizoxime suppository were compared using a rotating dialysis cell method, a dialysis membrane method and the JP XI rotating basket method. Only small variations in the dissolution rates were found with the rotating dialysis cell method and the rotating basket method, while the dialysis membrane method indicated rather large variation than other methods. In the rotating basket method, it was observed that a part of suppository bases came out through the wire mesh of the basket and spread over the surface of the dissolution medium. In the case of dialysis membrane method, it seemed that the large variations in dissolution rate was depending on a skill of the apparatus used.

As to obtain a good results, a selection of the rotating dialysis cell method was important. In vitro dissolutions of Ceftizoxime(CZX) suppository by using the rotating dialysis cell method were very rapid and also consistent with the absorption characteristics reported previously by Motohiro after rectal dose in pediatric subjects.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号