首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A direct, extraction‐free spectrophotometric method was developed for the determination of benzalkonium bromide (BAK). The method is based on the formation of mixed dye–surfactant aggregates between alizarin green (AG) and BAK in alkaline medium by measuring the decrease in absorbance of AG at 460 and 700 nm. Beer's law was obeyed in the concentration range 3–40 μg mL?1 with good precision and accuracy. The limits of detection were 0.4 μg mL?1 at 460 nm and 0.3 μg mL?1 at 700 nm, which reduced to 0.2 μg mL?1 by combining the absorbance at the two wavelengths. The proposed method was successfully applied to the determination of BAK in disinfectant solution and eye drops. The analytical results of the real samples were in good agreement with those of an HPLC method.  相似文献   

2.
徐红  刘红 《化工时刊》2009,23(3):38-40
基于偶氮蓝与溴代十六烷基吡啶相互作用而导致溶液吸收光谱的变化,用褪色光度法对该体系进行了研究。在pH=5.2的缓冲溶液中,偶氮蓝在531nm波长处有一强的特征吸收峰,当在其溶液中加入溴代十六烷基吡啶后,溶液发生褪色反应,吸光度差值与溴代十六烷基吡啶浓度成正比。最佳条件下,溴代十六烷基吡啶的浓度在0~60μg/25mL范围内遵守比尔定律,检测限(3σ)为0.22μg/mL。方法用于溴代十六烷基吡啶的测定,回收率为97.3%-103.7%。  相似文献   

3.
测量不确定度是表征被测量值的分散性,并与测量结果相联系的参数。在此通过对纳氏试剂光度法测定水中氨氮不确定度的来源进行分析,将不确定度分解为氨氮标准使用液配制过程中引入的、样品测定过程中引入的、分析仪器引入的各不确定,并对各个分量进行量化,计算各分量的相对标准不确定度和拓展不确定度,最终给出测定结果报告和评定结果分析。  相似文献   

4.
曾义 《当代化工》2014,(9):1903-1904
针对室内空气家中的甲醛特点,对传统的乙酰丙酮分光光度法在采样时间、样品收集、采样流量等方面进行优化,优化后的空气质量测定方法提高了室内空气监测准确性、拥有简便性快捷性的特点。对某市12户住宅室内的甲醛含量进行了检测,其中8户住宅超过了国家室内空气质量标准GB/T18883-2002规定的甲醛质量浓度0.1 mg/m3。  相似文献   

5.
采用分光光度法对十六烷基三甲基溴化铵(CTAB)-Al(Ⅲ)-铬天青S(CAS)三元络合物体系进行了研究。研究发现,在pH=6.0的B-R缓冲液中,CTAB的加入导致Al(Ⅲ)-CAS二元络合体系的吸光度增加,并在640 nm波长处产生最大吸收。实验结果表明,当5.0×10-4mol.L-1的CAS溶液用量为1.00 mL,20μg·L-1的Al(Ⅲ)溶液用量为1.00 mL时,CTAB质量浓度(ρ)在5~100 mg·L-1范围内与体系吸光度(A)呈良好的线性关系,线性方程为A=0.223 41ρ-0.042 37,相关系数r=0.999 9。该法用于环境水样中CTAB的测定,加标回收率为97%~103%。  相似文献   

6.
贺彦 《广东化工》2012,39(15):162-163
液氯泄露是自来水厂重大安全事故之一,因此,漏氯安全装置成为上级主管部门和水厂安全生产监查的主要项目。中山市稔益水厂安装的是氧化还原型漏氯安全吸收装置,装霞内的氯气吸收液主要成分是氯化亚铁。水厂规定对该装置的氯化亚铁浓度进行定期检测,频率为每月一次。因《生活饮用水标准检验方法》中没有氯化亚铁的测定方法,因此,氯化亚铁的检测需参考《生活饮用水标准检验方法》铁的检测方法以及《工业氯化铁国家标准》的检测方法,通过对两种氯化亚铁的检测方法进行对比分析,找出最适合的方法作为本水厂的日常检测方法。  相似文献   

7.
钟仙芳  王洪敏  费海州 《玻璃》2014,41(12):11-14
为提高公司质量控制技术,对中性交联剂、酸性交联剂和气相二氧化硅的氯离子含量进行分析。考察不同条件对氯离子含量测定的影响。本文采用4种方法进行对比,得出的结论能够对氯离子分析方法的选择提供一定的参考。  相似文献   

8.
何伟平 《广州化工》2015,(2):218-219
介绍了苯扎溴铵的反应原理及生产工艺。分析了其生产过程中的物质、工艺、设备等危险有害因素;结果表明其生产过程中涉及二甲胺、氯化苄、二甲基苄胺等危险化学品;若生产工艺和设备缺陷导致泄漏等,则存在火灾、爆炸、中毒等危险有害因素。并提出了安全管理、主要工艺技术和装置、设备检维修、事故应急救援等安全对策措施,建议安全设计和生产活动中应充分考虑这些危险有害因素,加强安全预防。  相似文献   

9.
比较分析了水中四氯乙烯含量的两种测定方法,并给出参考意见。  相似文献   

10.
卢海燕  林丽芬  张琰 《广州化工》2013,41(6):133-135
分别采用连续流动注射法和传统分光光度法测定水样中总氰化物的含量。对检测结果进行统计学中的F和t检验,结果表明这两种方法测得的结果数据无显著性差异,精密度、准确度等指标均符合分析标准要求。连续流动注射法的自动化程度更高,操作更简便、灵敏度更高。  相似文献   

11.
在H2SO4介质中,偏二甲肼对溴酸钾氧化甲基橙有一定的负催化作用,据此建立了负催化动力学光度法测定偏二甲肼的新方法。其线性范围为0.02~0.08μg/mL,检出限为1.3×10-2μg/mL。通过实验确定了测定的最佳条件。该方法简单、灵敏度高、稳定性好,用于水样中微量偏二甲肼的测定,效果良好。  相似文献   

12.
溴甲酚紫光度法测定阳离子表面活性剂的含量   总被引:6,自引:4,他引:2  
秦宗会  谭蓉 《日用化学工业》2006,36(6):392-394,408
在pH 6.40的NaH2PO4-Na2HPO4缓冲液中,溴甲酚紫与十六烷基溴化吡啶(CPB)和十六烷基三甲基溴化铵(CTAB)反应,形成离子缔合物,最大褪色波长均在588 nm处。CPB和CTAB的浓度分别在1.5×10-6mol/L~1.8×10-5mol/L和1.0×10-6mol/L~1.6×10-5mol/L遵守比耳定律,表观摩尔吸光系数分别为2.83×104L.mol-1.cm-1和3.23×104L.mol-1.cm-1,检测限分别为5.12×10-7mol/L和4.75×10-7mol/L,回收率为97.4%~104.1%。方法有高的灵敏度和良好的选择性,可用于水样中阳离子表面活性剂的测定。  相似文献   

13.
In this study, a novel azocalix[4]arene derivative, 5,11,17-tris[(1-naphtyl)azo]-25,26,27,28-tetrahydroxy-calix[4]arene (NAC4) bearing napthyl groups on the upper rim was synthesized. Its complexation behavior for alkali, alkaline-earth and various heavy metal ions (Li+, Na+, K+, Rb+, Cs+, Mg2+, Ca2+, Sr2+, Ba2+, Pb2+, Hg2+, Ni2+, Cd2+, Cu2+, Zn2+, Co2+, Fe2+, Cr3+, Ag+) was investigated by spectroscopic and voltammetric methods. This chemosensor exhibits decreased absorbance in the presence of Hg2+ and a unique absorbance quenching effect only for Cr3+. In addition, a new absorption band centered at 565 nm with the formation of the 1:1 host–guest complex (Cr3+-NAC4) was observed in the case of Cr3+, leading to an obvious color change from light orange to dark lilac. In voltammetric experiments, Cr3+ ions decreased voltammetric peaks of NAC4, whereas no significant changes occurred in the presence of the other metal ions. The Benesi–Hildebrand method was used to determine a logarithmic value of 3.76 for the association constant of the complex between Cr3+ and NAC4.  相似文献   

14.
周培  束影 《广东化工》2012,39(17):146+148
文章利用二苯碳酰二肼试剂在酸性条件下与六价铬反应,生成二苯碳酰二肼铬,化合物呈紫红色.在波长540 nm处有最大吸收峰。对制冷机中溴化锂溶液中的总铬进行测定,对总铬测定则采用先氧化,使铬全部转化为六价,然后再与二苯碳酰二肼反应。实验测定铬范围为0.020~0.20 mg/L,精密度±5%。样品回收率98%~102%,对样品稍加处理便能测定,方法简便。  相似文献   

15.
氯离子扩散系数是评价混凝土结构抗氯离子渗透性能和使用寿命的重要指标,选择一种快速、准确的测试方法至关重要.本文以非稳态电迁移实验(Rapid Chloride Migration,RCM)为基准,与国内外常用的几种氯离子扩散系数快速测试法比较,总结每种方法的特点及适用范围,建立RCM法与其他测试方法的相关性.结果表明:...  相似文献   

16.
本文对测定香荚兰果荚含水量的两种标准方法──国际标准[1]和法国标准[2]进行了研究和比较,并在实验中采用两种方法同时测定香荚兰果荚的含水量,实验结果表明,两种方法测得的结果是一致的。  相似文献   

17.
《分离科学与技术》2012,47(9):1260-1264
In this paper, two methods for measuring the equilibrium vapor sorption in polymers are critically compared and data on sorption of toluene, p-xylene, hexane, cyclohexane, and heptane in low density polyethylene are reported. The vapor phase calibration method (VPC) was used to measure vapor sorption at low vapor activities in air (below 0.01), and the gravimetric method was used to measure sorption over wide range of activities of pure vapors (0.1–0.9). The Flory-Huggins interaction parameter (in amorphous phase) varied between 1.00 for cyclohexane and 1.19 for toluene. The resulting confidence intervals are conjunctive, indicating that both methods provide consistent results.  相似文献   

18.
硫酸亚铁法和亚硫酸氢钠法是目前处理含六价铬废水常用的方法,但它们的处理工艺存在着明显的不同,通过试验研究、对比,指明了在不同的场合采用适宜的方法可以获得更佳的综合效果,从而为生产实践中电镀铬废水的处理提供参考.  相似文献   

19.
混凝土中氯离子渗透性测定的电化学方法   总被引:9,自引:0,他引:9  
史美伦  张雄 《硅酸盐通报》1998,17(6):55-59,63
本文提出了三种测定氯离子在混凝土中渗透性的简易的电化学方法,可用来代替较为复杂的ASTM建议的电学方法。方法简单省时,可靠性好,其中两法可用通用的电化学仪器进行测量,另一方法可以得到关于影响渗透性的务因素的信息。  相似文献   

20.
两种测定氧化铝载体孔结构方法的误差分析   总被引:1,自引:0,他引:1  
氮气吸附法和压汞法都是对氧化铝载体孔结构测定应用最广泛的方法,从原理、仪器和样品的具体情况三方面对氮气吸附法和压汞法进行了比较,分析了误差来源。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号