首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
本文论述了人体组织对γ射线的吸收给SPECT图像造成的影响,通过分析对比人体衰减的各种校正办法,提出了我们的新方法,采用偏置的线源和平行缝准直器,产生倾斜的扇形束投影,在同一台SPECT上获取透射型和发射型两种数据,从透射型数据重建出人体衰减系数的三维分布图。然后对发射型图像作精确的校正。  相似文献   

2.
An SPECT system dedicated to small animal imaging shall be of a millimeter spatial resolution or even better.This study was aimed at achieving 0.5-mm spatial resolution for a small animal SPECT system at low cost.It was developed from a single-head clinical SPECT scanner,with a seven-pinhole collimator and a four-degree-offreedom motion control stage.Several key techniques were developed,including high-resolution image reconstruction algorithm,high accuracy geometrical calibration method,and optimized system matrix derivation scheme.The system matrix was derived from Monte-Carlo simulation and de-noised by fitting each point spread function to a two dimensional Gaussian function.Experiments of point source and ultra micro hot rod phantom were conducted.With a spatial resolution of 0.5-0.6 mm,this system provides a practical way for low-cost high-resolution animal imaging on a clinic SPECT system.  相似文献   

3.
OMEGA500型单光子电脑断层(SPECT)系统是美国制造的一种比较先进的核医学系统。最近,由于采用了SENTINEL微处理器,使该系统以崭新的面目出现。 新设计的SENTINEL数字微处理器代替了原来OMEGA500中的某些电子学线路,可以提供一套系统校刻参数。这些校刻参数能提高SPECT系统总的性能,包括能量分辨率、线性度和均匀性。  相似文献   

4.
SPECT的衰减校正   总被引:1,自引:0,他引:1  
综述了常见的SPECT衰减校正方法,包括前、后校正法,本征法和迭代法。简要介绍了各种方法的基本原理并对各种方法的特点作了比较分析。从校正后图像的噪声特性、失真度、方法的运算速度有适用于何种脏器的重建等方面作了有关阐述。有助于系统理解不同的衰减校正方法,也对SPECT临床应用选择适当的衰减校正方法有所帮助。  相似文献   

5.
Properties of two algorithms for iterative reconstruction of SPECT images, LS-MLEM and LS-OSEM,are studied and compared with the ML-EM algorithm in this paper. By using projection data of heavy-noise, their effectiveness in improving SPECT image quality is evaluated. A phantom with hot and cold lesion is used in the investigation. The reconstructed images using LS-MLEM or LS-OSEM show that there is not a rapid increase in image noise,and the "best" estimate is assuming that the reconstructed images satisfy the statistical model. The major advantage of using LS-MLEM or LS-OSEM algorithm in SPECT imaging is in their ability to accurately control for heavy-noise. And LS-OSEM algorithm obviously improves the convergence rate.  相似文献   

6.
采用一种新颖的查找表法来实施有序子集期望值最大化(OSEM)的针孔SPECT图像重建算法,有效地将针孔响应修正包含在查找表中,进而实现高分辨针孔SPECT的三维图像重建。标准Jaszczak模具的成像实验结果表明:该方法不但能显著减少图像重建过程的计算时间和内存占用,且能显著改善重建图像的分辨率。因此,查找表法是能够快速实现针孔SPECTOSEM图像重建算法,并能将针孔响应修正包含在查找表中以获取高分辨断层图像的有效方法。  相似文献   

7.
本文探讨了SPECT/CT校准体模和重建方法的选择,以用于临床SPECT/CT的准确活度定量。分别对活度已知的点源、大圆柱、小圆柱3种校准体模进行SPECT/CT扫描,然后对每个断层数据依次采用4种重建方法(FBP、OSEM、OSEM+AC、OSEM+AC+SC)进行重建,并据此计算校准因子。将小圆柱作为活度定量的对象进行定量误差计算。OSEM+AC和OSEM+AC+SC的平均相对定量误差均小于10%,FBP和OSEM的平均相对定量误差均大于20%。OSEM+AC的平均相对定量误差在采用小圆柱做校准体模时与OSEM+AC+SC无显著差异,而在采用大圆柱和点源时,分别较OSEM+AC+SC的小3.38%和6.48%(P<0.05)。3种体模的对比中,采用OSEM+AC时差异不显著,采用其他重建方法时差异显著。采用OSEM+AC+SC时,小圆柱作校准体模的定量误差较大圆柱和点源的结果分别小3.92%和6.42%(P<0.05)。结果表明,基于CT和迭代算法的衰减校正可有效提升活度定量准确性,但散射校正的效果不佳;校准体模应尽可能与目标定量对象相似。合理选择校准体模和重建方法,可有效提升SPECT/CT的活度定量准确性。  相似文献   

8.
谢文煌  谢志淳 《核技术》1998,21(11):675-679
为了探讨SPECT对小儿脑梗塞(CCI)的诊断价值,对26例患儿采用SPECT局部脑血流灌注(rCP)显像与CT对比研究,结果表明,脑梗塞灶及远隔区域的rCP减少,SPECT和CT的阳性率分别为92.3%(24/26)和84.5%(22/26),两者无显著性差异(P〉0.05),而发病2天以内9例的SPECT阳性率100%(9/9)显著高于CT55.6%(5/9)(P〈0.05),提示SPECT显  相似文献   

9.
杨炯  管一晖 《核技术》1994,17(11):702-704
选择能反映SPECT性能的九项指标(平面显像部分:固有空间分辨率,系统空间分辨率,固有均匀性,能量分辨率,线性度,最大计数率;断层显像部分:断层分辨率,断层均匀性,旋转中心漂移),用组织等效材料制备了点源、线源和断层分辨率模型,并应用断层均匀性模型、四象限铅栅模型和线性模型对我院1988年5月引进的Elscint公司的APEX409AGSPECT进行了测试,并将测试结果与1988年有关测试结果相比较。  相似文献   

10.
刘侃峰  张彩霞 《同位素》2010,23(3):173-176
观察了131I-组胺-吲哚美辛(131I-His-IN)对荷Lewis肺癌大鼠的SPECT显像及内照射治疗效果,为肿瘤诊断及治疗提供依据。以灌胃的方式给荷Lewis肺癌的模型鼠131I-His-IN,并对灌药后的荷瘤鼠行SPECT显像及病理观察。结果显示,肿瘤部位与肿瘤以外各显影区域的131I-His-IN放射性计数比随时间延长明显升高,即131I-His-IN在肿瘤区的相对停留时间较长;病理结果显示肿瘤坏死组织随时间推移而增多。以上结果表明,131I-His-IN具有诊断肿瘤原发灶、远处转移灶的作用,对肿瘤具有双重治疗的作用,是当前进行肿瘤诊断及治疗的一种有效方法。  相似文献   

11.
上海市核医学显像仪器质控检测结果评估   总被引:2,自引:0,他引:2  
为了解上海市核医学显像仪器SPECT、γ-相机、扫描机的运转状况,促进显像仪器质量的提高.将系统模型、Hoffman脑模型置于显像床上,按各医院最佳临床常规显像条件采集,采用低能高分辨准直器.按各医院常规方法进行图像重建.甲状腺模型主要用于检测γ-相机分辨率.上海市目前20家医院有SPECT 22台,其中双探头8台,单探头14台.8台双探头SPECT,两探头固有均匀性目测较一致者5台,14台单探头固有均匀性较好者占11台;双探头SPECT的热区分辨率约为9-10mm,单探头约为11-12mm.双探头的冷区分辨率约为10mm,单探头约为11mm或12mm.断层线性显示,2台双探头4台单探头断层线性目测有歪曲,脑显像的图像不太理想.γ相机目前有6台,2台已停止使用,2台均匀度不均匀,2台均匀度目测尚均匀,固有分辨率为3-4mm.扫描机2台,仅能扫描出甲状腺模型的外形,不能分辨甲状腺"热"区和"冷"区.质控结果表明,上海市核医学显像仪器整体运行状况尚可,但应加快仪器的更新.  相似文献   

12.
刘兴党  刘永昌 《核技术》1996,19(11):646-648
对15例儿童癫痫进行发作间期SPECT脑局部血流显像,部分患者同时进行了EEG、CT、MRI检查。结果显示SPECT阳性率最高,EEG次之,CT、MRI检出率的低于前二者,表明SPECT脑血流显像是诊断儿童癫痫灶的有效方法,且对癫痫儿童的预后,局部脑血流变化与临床表现的演变之间关系等研究有帮助。  相似文献   

13.
1Introduction The rapid advance in molecular biology and the increasing use of transgenic mice as models of human biology and diseases have led to significant interests in the development of noninvasive,high-resolution,in vivo imaging techniques for small animals[1-4].Medi-cal imaging techniques including ultrasound(US),computed tomography(CT),magnetic resonance im-aging(MRI),positron emission tomography(PET),and single-photon emission computed tomography(SPECT),are contributing to this …  相似文献   

14.
建立了一种使用99Tcm-ECD为显像剂,SPECT为显像装置,不抽血定量测定局部脑血流的方法。两个不同年龄组正常志愿者共20例,通过静脉弹丸式注射99Tcm-ECD,利用动态显像和感兴趣区勾画技术获取大脑半球及主动脉弓的时间放射性曲线,同时对曲线进行死时间校正,结合图形分析方法确立脑血流灌注率(Ku),大脑半球的灌注指数(BPI)获得平均脑血流量(mCBF)。结果显示:20例正常人的脑血流值分别为53.81±5.27 mL(100 g)-1.min-1(5~16岁),47.19±4.99 mL(100 g)-1.min-1(22~32岁),不同年龄组间有显著差异。本测定方法具有无创性,实际工作中的可操作性等特点,在临床上便于广泛开展,有一定应用价值。  相似文献   

15.
樊卫  张力 《核技术》1998,21(11):672-674
选择49例非何杰金淋巴瘤和小细胞肺癌等患者,采用常规CHOP和CAV方案进行的治疗,定期用SPECT检测患者左心功能,评价阿霉素(ADM)对心肌的毒性作用,结果表明,化疗前后EF(射血分数)PER(高峰射血率)和PFR(高峰充盈率)值比较,差别有显著性(P〈0.05),体内的ADM累积量愈大,EF,PER和PFR值下降愈大,并以PFR变化最敏感,提示SPECT心功能测定是评价患者ADM心肌毒性的每  相似文献   

16.
本研究的目的旨在按NEMA标准设计一套通用的SPECT质量控制测试系统,供各种型号SPECT的验收,性能比较和常规质控使用。本系统以国内相当普及的IBM PC系列机作为工作平台。性能测试数据在不同型号的SPECT上采集后,通过计算机接口传送到IBM PC机,使用一个统一的软件进行测算。 本文包括接口设计和SPECT测试程序设计两部分,讨论了RS232串行接口管理程序的编制,SPECT测试程序数学模型和设计技巧,对SPECT测试程序设计中普遍遇到的问题做了详细分析、计算与讨论。SPECT质控测试系统包括11个子程序,用于测量γ相机和SPECT的主要性能指标。该系统在OMEGA 500/MCS 560 SPECT上使用,结果表明:系统操作简便、速度快、通用性好,能客观地反映SPECT的性能。  相似文献   

17.
符合线路SPECT-18FDG显像诊断肺癌的研究   总被引:5,自引:0,他引:5  
苗积生  王火强  潘惠忠 《核技术》2000,23(5):305-307
用双探头ECT进行^18FDG符合线路显像,探讨对肺癌的诊断价值。39例未确诊的肺部病变患者,禁食4h静脉注入37-111MBq^18FDG。静休1-2h在胸部行断层显像,用叠代法重建。检测病灶区与对侧对照区核素的浓聚比值,超过1.3为显像阳性。根据显像结果与肺癌诊断的灵敏度为93%(25/27),特异性83%(10/12),符合率90%(35/39),本显像技术对肺癌诊断有较好的应用价值。  相似文献   

18.
断层屏蔽SPECT成像法探讨   总被引:2,自引:0,他引:2  
赵经武  苏为宁 《核技术》2006,29(8):638-640
本文以空间积分原理为基础,以逐渐逼近法为图像重建的核心,探讨了可实现断层屏蔽的SPECT成像的途径.与传统的SPECT成像方法比较,它具有高的灵敏度和数据获取速度快的特点.由于无须用机械装置将γ照相机旋转,消除了运动带来的误差,提高了成像的质量.本文用线性方程组的松弛解法对无散射和无噪音的二维空间的模拟数据进行了验算,证明逐渐逼近法能逐渐逼近到放射性分布区域,并能基本给出分布形式.  相似文献   

19.
SPECT、CT对脊柱关节病的诊断价值   总被引:1,自引:0,他引:1  
李俊雄  黄旭璇  欧阳亮  林琛 《同位素》2002,15(3):185-187
为探讨CT、SPECT对脊柱关节病(SpA)的诊断价值,将临床诊断为SpA的102例患者,包括强直性脊柱炎(AS)63例,未分化脊柱关节病(uSpA)39例,分别进行CT骶髂关节扫描及SPECT全身及骶髂关节局部骨显像。结果显示,SPECT对AS的诊断总阳性率为50.8%(32/63),而且随着病情的发展而下降。CT对检查uSpA的阳性率仅为15.4%(6/39),远低于SPECT的阳性率82.1%(32/39)。因此,SPECT作为早期诊断SpA尤其是uSpA较敏感,并可作为AS治疗监测的重要手段,对临床SpA诊治具有重要意义。  相似文献   

20.
Conventional single-orbit cone beam tomography suffers from incomplete sampling and an inadequate three-dimensional (3D) reconstruction algorithm. The commonly used Feldkamp reconstruction algorithm simply extends the two-dimensional (2D) fan beam algorithm to 3D cone beam geometry. A truly 3D reconstruction formulation based on the 3D Fourier slice theorem is derived for a single-orbit cone beam SPECT. In the formulation, a nonstationary filter which depends on the distance from the central plane of the cone beam is derived and applied to the 2D projection data in directions along and normal to the axis of rotation. This algorithm was evaluated using both computer simulation and experimental measurements. Significant improvement in image quality was demonstrated in terms of decreased artifacts and distortions in cone beam reconstructed images. However, compared with the Feldkamp algorithm, a fivefold increase in processing time is required  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号