The International Method for the determination of the colour of beer has been tested by members of the Analysis Committee of the European Brewery Convention on samples of wort produced from a laboratory extract of malt using methods EBC 4.4 and EBC 4.4.5. The method, which relies on the spectrophotometric determination of colour at 430 nm, on clarified worts, is recommended as the designated reference method in place of the current visual method using EBC colour discs. The change will take effect from 1st January 1996. It was judged that precision values were dependent on the intensity of the colour of the sample over the range 3.6 to 25.3 EBC units. Repeatability (r98) and Reproducibility (R98) values of r98 0.18Mean ? 0.28 and R98 = 0.13Mean + 0.46 were obtained over this range.  相似文献   

2.
A method for the determination of pH in wort and beer has been tested for precision by the Analysis Committee of the Institute of Brewing . Over the pH range 3.94 to 5.04 it was judged that precision values were independent of the pH value of the sample. Values for r95 and R95 were 0.025 and 0.129 respectively .  相似文献   

3.
After about fifteen years a study was carried out to determine the variation in results of the N‐nitrosodimethylamine (NDMA) determination in beer and malt carried out in different laboratories, in order to obtain an overall view of the precision of the various methods used. Two collaborative trials were carried out by the EBC Analysis Committee during 1998. Repeatability values (r95) for beer in the range of 0.09 ÷ 0.13 and for malt 0.33 ÷ 0.42 were found. Reproducibility values (R95) for beer in the range of 0.45 ÷ 0.54 and for malt 0.65 ÷ 4.08 were obtained.  相似文献   

4.
1A method, relying on ion chromatography, for the determination of nitrate in beer, has been collaboratively tested by members of the European Brewery Convention (EBC) and the Brewery Convention of Japan (BCOJ). Precision values were judged to be acceptable. Repeatability (r95) and reproducibility (R95) values were 1.5, 0.96, 5.1, and 9.3, 10.4, 13.5 respectively for corresponding mean levels of 6.5, 26.2 and 52.8 mg/litre. However, r95 and R95 values of 1.5 and 2.3 respectively were obtained for an aqueous solution of nitrate ions at a mean level of 20.7 mg/litre. The determination of nitrate is recommended for use and inclusion in Analytica-EBC, as an additional analyte in the International Method which relies on ion chromatography for estimating chloride, sulphate and phosphate.  相似文献   

5.
A procedure relying on high performance liquid chromatography for the estimation of iso-alpha-acids in beer has been collaboratively tested by the IOB Analysis Committee. In addition the trial samples were analysed by the IOB Recommended Method for the measurement of bitterness (BU). It was judged that the results obtained by the HPLC method were not sufficiently precise to permit adoption as a Recommended Method. However, since the method has the advantage of measuring bitterness in terms of iso-alpha-acids, it is suggested as an alternative to that of the Recommended Method. The iso-alpha-acids are absorbed from beer on to a C18 Bond Elut column and then selectively desorbed prior to isocratic analysis by HPLC using an eluting solvent of methanol/water/phosphoric acid/tetrabutylammonium hydroxide and a C18 radialpak cartridge. For both methods the repeatability values (r95) were not dependent upon mean concentration (m) whereas the reproducibility values (R95) were dependent upon concentration. The values of (r53) and (R95) obtained were 2.11 and (1.38 + 0.134 m) over the concentration range 13.8 to 34.0 mg/litre for the HPLC procedure and 1.20 and (0.76 + 0.122 m) over the concentration range 15.4 to 38.6 BU for the Recommended Method.  相似文献   

6.
The Institute of Brewing Analysis Committee has collaboratively tested four methods for the determination of sulphur dioxide in beer over the range 1 to 40 mg/litre. The p-rosaniline method (r95 = 0.51 + 0.10 m. R95 = 0.63 + 0.26 m) was found to have the best precision and is recommended as an alternative to the Monier Williams method (r95 = 0.43 + 0.15 m, R95 = 1.86 + 0.27 m) where high precision at low sulphur dioxide levels is required. The dithiobisnitrobenzoic acid (DTNB) method and the IOB rapid distillation method showed considerably worse precisions.  相似文献   

7.
A method relying on headspace sampling and gas chromatography for the determination of the lower boiling point volatile compounds (fusel oils) in beer, has been approved by the Analysis Committee of the Institute of Brewing (IOB), for inclusion in Recommended Methods of Analysis. In view of the large values obtained for precision in terms of repeatability (r95) and reproducibility (R95) and the differences in gas chromatographic equipment used by individual brewing laboratories, the method is considered not to be ideal, but is given as a guideline only. The IOB Analysis Committee has recommended a method relying on gas chromatography and flame photometric detection for the determination of dimethyl sulphide in beer. Repeatability (r95) and reproducibility (R95) values of 3.3 μg/litre and 3.66+0.168 m μg/litre (where m is concentration), respectively, were obtained over the range 20–50 μg/litre. Methods currently used in brewing laboratories, for the measurement of vicinal diketones, are being surveyed with a view to obtaining a suitable method for collaborative testing by the Analysis Committee.  相似文献   

8.
A viscometric method for estimation of endo beta-glucanase activity in malt has been collaboratively tested by the Institute of Brewing Analysis Committee. Ten participating laboratories analysed five pairs of malt samples in the range 176 to 1238 IRV units. The repeatability (r95) values ranged from 22 to 122 IRV units and the reproducibility (R95) values from 93 to 650 IRV units. The results indicated that R95, but not r95, was dependent on endo beta-glucanase activity. Overall precision values were 76.8 for r95 and 0.506Mean + 4.786 for R95. It was decided that the method would be included in IOB Methods of Analysis but that attention would be drawn to the poor precision values obtained in this and previous collaborative trials.  相似文献   

9.
Two methods for the determination of vicinal diketones in beer have been collaboratively tested by the Analysis Committee of the Institute of Brewing and are recommended for use. Both methods employ gas chromatography and are essentially the same, except that one relies on the use of a packed column and the other on a capillary column. For diacetyl it was judged that repeatability (r95) values were independent of concentration over the range 0.04 to 0.19 mg/litre. Over this range, r95 values for diacetyl of 0.028, 0.020 and 0.026 mg/litre were obtained for capillary, packed columns and combined results respectively. Values for reproducibility (R95) were judged to be dependent on the mean level (m). R95 values were 0.032 + 0.68 m, 0.01 + 0.47 m and 0.005 + 0.67 m were obtained for capillary, packed columns and combined results respectively. For both methods the r95 and R95 values for 2,3-pentanedione were judged to be independent of concentration over the range 0.02 to 0.07 mg/litre. For capillary columns, packed columns and combined results respectively, r95 values were 0.009, 0.009, 0.010 mg/litre and R95 values were 0.037, 0.042 and 0.038 mg/litre.  相似文献   

10.
In the brewing industry, barley malt is often partially replaced with adjuncts (unmalted barley, wheat, rice, sorghum and corn in different forms). It is crucial, however, to preserve constant quality in the beer to meet the expectations of consumers. In this work, how the addition of corn grist (10 and 20%) influences the quality of wort and beer was examined. The following parameters were analysed: wort colour, dimethyl sulphide (DMS) and protein content, non‐fermentable extract, extract drop during fermentation, alcohol content and the attenuation level of the beer, together with filtration performance. The samples (all‐malt, and adjunct at 10 and 20% corn grist) were industrial worts and the beers produced in a commercial brewery (3000 hL fermentation tanks). The application of 10 and 20% corn grist had an effect on the wort colour, making it slightly lighter (11.1 and 10.5°EBC, respectively) than the reference barley malt wort (12.2°EBC). The free amino nitrogen level, DMS and non‐fermentable extract were significantly lower in the worts produced with the adjunct; the alcohol content and attenuation levels were higher in the beers produced with adjunct. The use of corn grist, at the level of up to 20% of total load, appears to affect some of the technological aspects of wort and beer production, but it does not significantly influence the final product characteristics. Copyright © 2014 The Institute of Brewing & Distilling  相似文献   

11.
A combustion method, relying on the Dumas principle, for the determination of total nitrogen in barley and malt, has been collaboratively tested by the Analysis Committee of the European Brewery Convention. Repeatability, r95, and reproducibility, R95, values were 0.063 and 0.116% of dry matter, respectively, for samples with nitrogen contents in the range 1.23 to 1.86% N of dry matter. There was no significant difference between these values for barley and malt. The Analysis Committee approved the adoption of the combustion method for inclusion in Analytica EBC as an alternative method.  相似文献   

12.
A simple spectrophotometric method for the determination of nitrogen in unhopped wort has been tested by the EBC Analysis Committee and accepted for inclusion in Analytica-EBC. The spectrophotometric method is intended as a quick method for routine quality control. It is emphasized that the procedure has to be followed in detail and that the precautions stated under Notes on Procedure are most important. The average precision values obtained for the range 600 to 850 mg/litre were r95=30 and R95 = 104.  相似文献   

13.
The determination of the moisture and nitrogen contents of barley and malt by near infrared spectroscopy (NIRS) has been tested by the Analysis Committee of the European Brewery Convention. In the collaborative trial four samples of barley and malt were analysed by 17 laboratories. Repeatability (r95) and reproducibility (R95) values of 0.3 and 1.5% m/m respectively were obtained for barley moisture over the range 12.7 to 15.8% m/m. For malt moisture these values were 0.2 and 1.3% m/m over the range 4.0 to 4.3% m/m, for barley nitrogen 0.1 and 0.3% m/m on dry matter over the range 1.57 to 2.14% m/m, and for malt nitrogen 0.1 and 0.2% m/m on dry matter over the range 1.58 to 1.82% m/m, respectively.  相似文献   

14.
A method employing gas chromatography for the determination of ethanol in beer has been collaboratively tested by the Analysis Committee of the Institute of Brewing. It was judged that precision values were independent of concentration over the range 0.93 to 6.05% V/V ethanol. Repeatability (r95) and reproducibility (R95) values of 0.061 and 0.136 respectively, were obtained over this range. At a mean level of 9.17% V/V, the r95 and R95 values were 0.154 and 0.284 respectively. This was probably due to dilution errors as the sample had to be diluted to bring it within the linear range of the method. A comparison of the precision values given by the gas chromatographic method, with those obtained in 1991/1992 by 8 laboratories in a major brewing company using 12 sample pairs, for the IOB Recommended Distillation Method, revealed that there is no significant difference between the precision data for the two methods.  相似文献   

15.
A method employing a density meter for the determination of specific gravity (SG) has been tested for the determination of the gravity (G) of beer, aqueous sugar solutions and aqueous ethanol solutions by the Analysis Committee of the Institute of Brewing. The term “gravity”, used throughout this report is defined by the equation G = SG × 1000. Repeatability (r95) and reproducibility (R95) values were calculated over the range 994.6 to 1124.2 gravity. For beer, it was judged that precision values were independent of the gravity of the sample. Values for r95 and R95 were 0.1 and 0.9, respectively, for instruments with a 5 figure display and 0.08 and 0.32, respectively, for instruments with a 6 figure display, over the range 999.1 to 1017.0 gravity. For solutions of ethanol in water, precision was also independent of the gravity of the sample. Values for r95 and R95 were 0.1 and 0.3, respectively, for instruments with a 5 figure display and 0.05 and 0.19, respectively, for instruments with a 6 figure display, over the range 994.6 to 999.1 gravity. For aqueous sugar solutions the values of r95 and R95 increased with increasing gravity. At 1049.3 gravity, values for r95 and R95 were 0.1 and 0.8, respectively, for instruments with a 5 figure display and 0.07 and 0.35, respectively, for instruments with a 6 figure display. At 1124.2 gravity values for r95 and R95 were 0.2 and 1.4, respectively, for instruments with a 5 figure display and 0.16 and 1.35, respectively, for instruments with a 6 figure display.  相似文献   

16.
Methods for the determination of caramel and roasted malt moisture, extract and colour published in Analytica EBC have been collaboratively tested by the European Brewery Convention Analysis Committee, according to the ISO standard 5725. Repeatability (r95) and reproducibility (R95) values are presented.  相似文献   

17.
Two methods, the “Rudin” method and the “Nibem” method have been tested for the determination of foam stability of beer by the Analysis Committee of the Institute of Brewing . For the Rudin method, over the range 90 to 102 seconds, it was judged that precision values were independent of the foam stability of the sample. Values for r95 and R95 were 6 and 22 seconds, respectively . For the Nibem method, precision was also independent of the foam stability of the sample over the range 213 to 246 seconds. Values for r95 and R95 were 22 and 70 seconds, respectively . The two methods ranked the foam stability of the three beers tested differently. This is to be expected, bearing in mind the different principles of the two procedures .  相似文献   

18.
Dark specialty malts are important ingredients for the production of several beer styles. These malts not only impart colour, flavour and antioxidative activity to wort and beer, they also affect the course of wort fermentations and the production of flavour‐active yeast metabolites. The application of considerable levels of dark malt was found to lower the attenuation, mainly as a result of lower levels of fermentable sugars and amino acids in dark wort samples. In fact, from the darkest caramel malts and from roasted malts, practically no fermentable material can be hydrolysed by pilsner malt enzymes during mashing. Compared to wort brewed with 50% pilsner malt and 50% dark caramel malt or roasted malt, wort brewed with 100% pilsner malt contained nearly twice as much fermentable sugars and amino acids. Reduced levels of yeast nutrients also lowered the fermentation rate, ranging from 1.7°P/day for the reference pilsner wort of 9 EBC to 1.1°P/day for the darkest wort (890 EBC units), brewed with 50% roasted malt. This additionally indicates that lower attenuation values for dark wort are partially due to the inhibitory effects of Maillard compounds on yeast metabolism. The application of dark caramel or roasted malts further led to elevated levels of the vicinal diketones diacetyl and 2,3‐pentanedione. Only large levels of roasted malt gave rise to two significant diacetyl peaks during fermentation. The level of ethyl acetate in beer was inversely related to colour, whereas the level of isoamyl acetate appeared to be affected by the use of roasted malt. With large levels of this malt type, negligible isoamyl acetate was generated during fermentation.  相似文献   

19.
A procedure for preparing torrefied products for analysis has been examined and the effects of this procedure on the determination of laboratory extract and colour have been collaboratively tested by the Analysis Committee of the Institute of Brewing. White malts of DP levels 50° and 100° IOB were used as the sources of enzymes in the mixed mash procedure. With these malts r95 and R95 values for extract of the torrefied products ranged from 1.7 to 10.2 and 12.4 to 21.9 resp. on mean extracts ranging from 244 to 270 litre °/kg. The r95 and R95 values for colour ranged from 1.6 to 2.3 and 2.2 to 3.8 resp. on mean colours ranging from 2.7 to 3.5 EBC units.  相似文献   

20.
A method for the determination of boiled wort colour has been collaboratively tested by the Analysis Committee of the European Brewery Convention. In this trial the 14th EBC Standard Malt and two commercial malts were tested by 21 laboratories. Repeatability (r95) and reproducibility (R95) values of 0.33 ? 0.42 and 1.12 ? 1.44 EBC units were obtained respectively at a mean level of 4.7 ? 5.2 EBC units. At a mean level of 8.9 EBC units these respective values were 0.44 and 2.25 EBC units. The data sets could be split into two sub?sets for laboratories using either the included heating plate boiling procedure or the glycerol/oil bath boiling procedure. Statistical analysis of both sub?sets revealed that reproducibility is unambiguously better for the glycerol/oil bath procedure at all levels. For repeatability the situation is less clear. The evaluated method is recommended for inclusion in Analytical?EBC.  相似文献   