首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this investigation, boiling incipience and bubble dynamics on a microheater with a geometry of 100 μm × 100 μm fabricated with MEMS technology are evaluated using a high-speed digital camera. For the purpose of comparison with conventional boiling heat transfer, boiling incipience and bubble dynamics are also studied on a carefully selected microheater with a fabricated defect (i.e., a microcavity on the heater surface). Of industrial interest are the effects of dissolved gases on boiling incipience and bubble dynamics, which are also discussed in detail. The possible nucleation temperature (or incipience temperature) is analyzed and discussed from the perspective of the measured bulk temperature of the microheater and a 3D heat conduction numerical model. The time-resolved bubble dynamics (i.e., the bubble size evolution, interface velocity and interface acceleration) are all presented along with high-speed digital images. Based upon this investigation, it is clear that explosive boiling can take place on a smooth surface no matter how slow the heating rate, and dissolved gases have a significant influence on the incipience temperature and bubble behavior. Furthermore, this study illustrates that the classical kinetics of boiling can explain the explosive boiling occurring on a smooth surface in principle and can provide a useful guide for the design of microscale heat transfer and/or MEMS devices. Although unexpected, due to the gravitational effects, Marangoni flow on the vapor–liquid interface induced by the temperature gradient was also observed.  相似文献   

2.
To elucidate the mechanism and characteristics of boiling heat transfer in a micro‐channel vaporizer, the experimental investigation of the micro‐layer thickness that formed between the heating surface and vapor generated was important. The micro‐layer thickness was measured applying the laser extinction method for channel gap sizes of 0.5, 0.3, and 0.15 mm. It was clarified that the gap size, the rate of bubble growth, and the distance from the incipient bubble site have an effect on the micro‐layer thickness in a micro‐channel boiling system. The initial micro‐layer thickness grew with an increase of the velocity of bubble forefront to moderate the value of the velocity. In the region of greater velocity, the thickness was constant for each gap. The distributions of the initial thickness of micro‐layer on the heat transfer surface were shown. © 2005 Wiley Periodicals, Inc. Heat Trans Asian Res, 35(1): 35–46, 2006; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.20096  相似文献   

3.
The present study is an experimental investigation of nucleate boiling heat transfer mechanism in pool boiling from wire heaters immersed in saturated FC-72 coolant and water. The vapor volume flow rate departing from a wire during nucleate boiling was determined by measuring the volume of bubbles from the wire utilizing the consecutive-photo method. The effects of the wire size on heat transfer mechanism during a nucleate boiling were investigated, varying 25 μm, 75 μm, and 390 μm, by measuring vapor volume flow rate and the frequency of bubbles departing from a wire immersed in saturated FC-72. One wire diameter of 390 μm was selected and tested in saturated water to investigate the fluid effect on the nucleate boiling heat transfer mechanism. Results of the study showed that an increase in nucleate boiling heat transfer coefficients with reductions in wire diameter was related to the decreased latent heat contribution. The latent heat contribution of boiling heat transfer for the water test was found to be higher than that of FC-72. The frequency of departing bubbles was correlated as a function of bubble diameters.  相似文献   

4.
A four-zone flow boiling model is presented to describe saturated flow boiling heat transfer mechanisms in a microchannel of rectangular cross-section. The boiling process in the microchannel is assumed to be a cyclic passage of four zones: (i) liquid-slug zone, (ii) elongated bubble zone, (iii) partially-dryout zone, and (iv) fully-dryout zone. The existence of the partially-dryout zone in this model is proposed to take into consideration of corner effects on boiling heat transfer in the microchannel. To verify this new model, an experimental study was carried out to investigate flow boiling heat transfer of water in a microchannel having a rectangular cross-section with a hydraulic diameter of 137 μm (202 μm in width and 104 μm in depth) with a length of 30 mm under three-side heating condition. The data for bubble nucleation frequency was correlated in terms of the Boiling number, which was used to determine the heat transfer coefficient. It is found that the present four-zone flow boiling model successfully predicts trends of boiling heat transfer data in a microchannel with a rectangular cross-section, having a sharp peak at low vapor quality depending on the mass flow rate. The predictions of flow boiling heat transfer coefficient in the microchannel are found in good agreement with experimental data with a MAE of 13.9%.  相似文献   

5.
Heat transfer associated with a vapor bubble sliding along a downward-facing inclined heater surface was studied experimentally using holographic interferometry. Volume growth rate of the bubbles as well as the rate of heat transfer along the bubble interface were measured to understand the mechanisms contributing to the enhancement of heat transfer during sliding motion. The heater surface was made of polished silicon wafer (length 185 mm and width 49.5 mm). Experiments were conducted with PF-5060 as test liquid, for liquid subcoolings ranging from 0.2 to 1.2 °C and wall superheats from 0.2 to 0.8 °C. The heater surface had an inclination of 75° to the vertical. Individual vapor bubbles were generated in an artificial cavity at the lower end of the heater surface. High-speed digital photography was used to measure the bubble growth rate. The temperature field around the sliding bubble was measured using holographic interferometry. Heat transfer at the bubble interface was calculated from the measured temperature field. Results show that for the range of parameters considered the bubbles continued to grow, with bubble growth rates decreasing with increasing liquid subcooling. Heat transfer measurements show that condensation occurs on most of the bubble interface away from the wall. For the parameters considered condensation accounted for less than 12% of the rate heat transfer from the bubble base. In this study the heater surface showed no drop in temperature as a result of heat transfer enhancement during bubbles sliding.  相似文献   

6.
7.
A new cooling scheme is proposed where the primary working fluid flowing through a micro-channel heat sink is pre-cooled to low temperature using an indirect refrigeration cooling system. Cooling performance was explored using HFE 7100 as working fluid and four different micro-channel sizes. High-speed video imaging was employed to help explain the complex interrelated influences of hydraulic diameter, micro-channel width, mass velocity and subcooling on cooling performance. Unlike most prior two-phase micro-channel heat sink studies, which involved annular film evaporation due high void fraction, the low coolant temperatures used in this study produced subcooled flow boiling conditions. Decreasing coolant temperature delayed the onset of boiling, reduced bubble size and coalescence effects, and enhanced CHF. Heat fluxes in excess of 700 W/cm2 could be managed without burnout. Premature CHF occurred at low mass velocities and was caused by vapor flow reversal toward the inlet plenum. This form of CHF was eliminated by decreasing coolant temperature and/or increasing flow rate.  相似文献   

8.
A photographic study was carried out for the subcooled flow boiling of water to elucidate the rise characteristics of single vapor bubbles after the departure from nucleation sites. The test section was a transparent glass tube of 20 mm in inside diameter and the flow direction was vertical upward; liquid subcooling was parametrically changed within 0–16 K keeping system pressure and liquid velocity at 120 kPa and 1 m/s, respectively. The bubble rise paths were analyzed from the video images that were obtained at the heat flux slightly higher than the minimum heat flux for the onset of nucleate boiling. In the present experiments, all the bubbles departed from their nucleation sites immediately after the inception. In low subcooling experiments, bubbles slid upward and consequently were not detached from the vertical heated wall; the bubble size was increased monotonously with time in this case. In moderate and high subcooling experiments, bubbles were detached from the wall after sliding for several millimeters and migrated towards the subcooled bulk liquid. The bubbles then reversed the direction of lateral migration and were reattached to the wall at moderate subcooling while they collapsed due to the condensation at high subcooling. It was hence considered that the mechanisms of the heat transfer from heated wall and the axial growth of vapor volume were influenced by the difference in bubble rise path. It was observed after the inception that bubbles were varied from flattened to more rounded shape. This observation suggested that the bubble detachment is mainly caused by the change in bubble shape due to the surface tension force.  相似文献   

9.
10.
Flow boiling in microchannels is favored by the heat transfer community due to the high heat transfer rates that can be obtained with lower mass flow rates. However, the heat transfer rates for flow boiling in microchannels are impacted by flow reversals and flow instabilities. An open microchannel structure was recently proposed to reduce the impact of the flow boiling instabilities. Subcooled flow boiling experiments were conducted in open microchannels using deionized water. The open microchannels had 6 parallel channels with a 0.3 mm uniform thickness gap above them The channels were fabricated on a 6 mm × 40 mm copper block. The channels were 0.5 mm wide and 0.3 mm deep with 0.43 mm wide fins between them. Flow visualizations were performed with a high-speed CCD camera with the results showing that the flow regimes in the open microchannels differ from those in closed microchannels with stratified flow and no flow instability. Two types of confined bubbles were observed with characterizations of the effects of the bubbles on each other. The heat transfer mechanisms for flow boiling in open microchannels are also described.  相似文献   

11.
An experiment is carried out here to investigate the evaporation heat transfer and associated evaporating flow pattern for refrigerant R-134a flowing in a horizontal narrow annular duct. The gap of the duct is fixed at 1.0 and 2.0 mm. In the experiment, the effects of the duct gap, refrigerant vapor quality, mass flux and saturation temperature and imposed heat flux on the measured evaporation heat transfer coefficient hr are examined in detail. For the duct gap of 2.0 mm, the refrigerant mass flux G is varied from 300 to 500 kg/m2 s, imposed heat flux q from 5 to 15 kW/m2, vapor quality xm from 0.05 to 0.95, and refrigerant saturation temperature Tsat from 5 to 15 °C. While for the gap of 1.0 mm, G is varied from 500 to 700 kg/m2 s with the other parameters varied in the same ranges as that for δ = 2.0 mm. The experimental data clearly show that the evaporation heat transfer coefficient increases almost linearly with the vapor quality of the refrigerant and the increase is more significant at a higher G. Besides, the evaporation heat transfer coefficient also rises substantially at increasing q. Moreover, a significant increase in the evaporation heat transfer coefficient results for a rise in Tsat, but the effects are less pronounced in the narrower duct at a low imposed heat flux and a high refrigerant mass flux. Furthermore, the evaporation heat transfer coefficient increases substantially with the refrigerant mass flux except at low vapor quality. We also note that reducing the duct gap causes a significant increase in hr. In addition to the heat transfer data, photos of R-134a evaporating flow taken from the duct side show the change of the dominant two-phase flow pattern in the duct with the experimental parameters. Finally, an empirical correlation for the present measured heat transfer coefficient for the R-134a evaporation in the narrow annular ducts is proposed.  相似文献   

12.
This study examines the pressure drop and heat transfer characteristics of annular condensation in rectangular micro-channels with three-sided cooling walls. A theoretical control-volume-based model is proposed based on the assumptions of smooth interface between the annular liquid film and vapor core, and uniform film thickness around the channel’s circumference. Mass and momentum conservation are applied to control volumes encompassing the liquid film and the vapor core separately. The model accounts for interfacial suppression of turbulent eddies due to surface tension with the aid of a new eddy diffusivity model specifically tailored to shear-driven turbulent films. The model predictions are compared with experimental pressure drop and heat transfer data for annular condensation of FC-72 along 1 × 1 mm2 parallel channels. The condensation is achieved by rejecting heat to a counterflow of water. The data span FC-72 mass velocities of 248–367 kg/m2 s, saturation temperatures of 57.8–62.3 °C, qualities of 0.23–1.0, and water mass flow rates of 3–6 g/s. The data are also compared to predictions of previous separated flow mini/micro-channel and macro-channel correlations. While some of the previous correlations do provide good predictions of the average heat transfer coefficient, they fail to capture axial variation of the local heat transfer coefficient along the channel. The new model accurately captures the pressure drop and heat transfer coefficient data in both magnitude and trend, evidenced by mean absolute error values of 3.6% and 9.3%, respectively.  相似文献   

13.
This second part of a two-part study concerns heat transfer characteristics for FC-72 condensing along parallel, square micro-channels with a hydraulic diameter of 1 mm, which were formed in the top surface of a solid copper plate. Heat from the condensing flow was rejected to a counter flow of water through channels brazed to the underside of the copper plate. The FC-72 condensation heat transfer coefficient was highest near the channel inlet, where the annual liquid film is thinnest. The heat transfer coefficient decreased along the micro-channel because of the film thickening and eventual collapse of the annular regime. Notable heat transfer enhancement was observed for annular flow regions of the micro-channel associated with interfacial waves. Comparing the present data to predictions of previous annular condensation heat transfer correlations shows correlations intended for macro-channels generally provide better predictions than correlations intended specifically for mini/micro-channels. A new condensation heat transfer coefficient correlation is proposed for annular condensation heat transfer in mini/micro-channels. The new correlation shows excellent predictive capability based on both the present FC-72 data and a large database for mini/micro-channel flows amassed from eight previous sources.  相似文献   

14.
Flow boiling heat transfer experiments using R134a were carried out for jet impingement on smooth and enhanced surfaces. The enhanced surfaces were circular micro pin fins, hydrofoil micro pin fins, and square micro pin fins. The effects of saturation pressure, heat flux, Reynolds number, pin fin geometry, pin fin array configuration, and surface aging on flow boiling heat transfer characteristics were investigated. Flow boiling experiments were carried out for two different saturation pressures, 820 kPa and 1090 kPa. Four jet exit velocities ranging from 1.1–4.05 m/s were investigated. Flow boiling jet impingement on smooth surfaces was characterized by large temperature overshoots, exhibiting boiling hysteresis. Flow boiling jet impingement on micro pin fins displayed large heat transfer coefficients. Heat transfer coefficients as high as 150,000 W/m2 K were observed at a relatively low velocity of 2.2 m/s with the large (D = 125 μm) circular micro pin fins. Jet velocity, surface aging, and saturation pressure were found to have significant effects on the two-phase heat transfer characteristics. Subcooled nucleate boiling was found to be the dominant heat transfer mechanism.  相似文献   

15.
Dispersed flow film boiling heat transfer in vertical narrow annular gaps with gap sizes of 1.0, 1.5 and 2.0 mm was experimentally investigated with de-ionized water as the working fluid at low mass velocities. Comparisons of the experimental data with established correlations show that the correlations are not accurate for small gaps. The influences of the heating mode (only one tube heating or both tubes heated), the gap size and the tube diameter were analyzed. The data was correlated in the form of the Groeneveld equation with a modified wall temperature factor as use in the Polomik correlation and a modified gap size factor as use in the Yun and Muthu correlation. A new correlation was developed for dispersed flow film boiling heat transfer based on the experimental data for 1.0–2.0 mm gaps.  相似文献   

16.
The rapid increase of heat flux in high performance electronic devices has necessitated the development of high capacity thermal management techniques that can support extremely high heat transfer rates. Flow boiling in microgap is very promising for this purpose due to its high heat transfer rate and ease of fabrication. However, the effects of microgap dimension on heat transfer and pressure drop characteristics along with flow visualization have not been investigated extensively. This paper focuses on flow boiling experiments of deionized water in silicon microgap heat sink for ten different microgap dimensions from a range of 80 μm–1000 μm to determine the most effective and efficient range of microgap dimensions based on heat transfer and pressure drop performance. High speed flow visualization is conducted simultaneously along with experiments to illustrate the bubble characteristics in the boiling flow in microgap. The results of this study show that confinement in flow boiling occurs for microgap sizes 500 μm and below and confined slug/annular flow is the main dominant regime whereas physical confinement does not occur for microgap sizes 700 μm and above and bubbly flow is the dominant flow regime. The microgap is ineffective below 100 μm as partial dryout strikes very early and the wall temperature is much higher for a fixed heat flux as microgap size increases above 500 μm. In addition, results show that pressure drop and pressure fluctuation decrease with the increases of gap size whereas wall temperature and wall temperature fluctuation increase with the increases of gap size. A strong dependence of heat transfer coefficient on microgap sizes is observed for microgap sizes 500 μm and below. However, the heat transfer coefficient is independent of microgap size for microgap sizes 700 μm and above.  相似文献   

17.
An experiment is carried out here to investigate flow boiling heat transfer and associated bubble characteristics of FC-72 on a heated micro-pin-finned silicon chip flush-mounted in the bottom of a horizontal rectangular channel. Besides, three different micro-structures of the chip surface are examined, namely, the smooth, pin-finned 200 and pin-finned 100 surfaces. The pin-finned 200 and 100 surfaces, respectively, contain micro-pin-fins of size 200 μm × 200 μm × 70 μm (width × length × height) and 100 μm × 100 μm × 70 μm. The pitch of the fins is equal to the fin width for both surfaces. The effects of the FC-72 mass flux, imposed heat flux, and surface micro-structures of the silicon chip on the FC-72 saturated flow boiling characteristics are examined in detail. The experimental data show that an increase in the FC-72 mass flux causes a delay in the boiling incipience. However, the flow boiling heat transfer coefficient is not affected by the coolant mass flux. But adding the micro-pin-fin structures to the chip surfaces can effectively enhance the single-phase convection and flow boiling heat transfer. Moreover, the mean bubble departure diameter and active nucleation site density are reduced for a rise in the FC-72 mass flux. A higher coolant mass flux results in a higher mean bubble departure frequency. Furthermore, larger bubble departure diameter, higher bubble departure frequency, and higher active nucleation site density are observed at a higher imposed heat flux. We also note that adding the micro-pin-fins to the chips decrease the bubble departure diameter and increase the bubble departure frequency. However, the departing bubbles are larger for the pin-finned 100 surface than the pin-finned 200 surface but the bubble departure frequency exhibits an opposite trend. Finally, empirical equations to correlate the present data for the FC-72 single-phase liquid convection and saturated flow boiling heat transfer coefficients and for the bubble characteristics are provided.  相似文献   

18.
Experiments are conducted here to investigate subcooled flow boiling heat transfer and associated bubble characteristics of FC-72 on a heated micro-pin-finned silicon chip flush-mounted on the bottom of a horizontal rectangular channel. In the experiments the mass flux is varied from 287 to 431 kg/m2 s, coolant inlet subcooling from 2.3 to 4.3 °C, and imposed heat flux from 1 to 10 W/cm2. Besides, the silicon chips contain three different geometries of micro-structures, namely, the smooth, pin-finned 200 and pin-finned 100 surfaces. The pin-finned 200 and 100 surfaces, respectively, contain micro-pin-fins of size 200 μm × 200 μm × 70 μm (width × length × height) and 100 μm × 100 μm × 70 μm. The measured data show that the subcooled flow boiling heat transfer coefficient is reduced at increasing inlet liquid subcooling but is little affected by the coolant mass flux. Besides, adding the micro-pin-fin structures to the chip surface can effectively raise the single-phase convection and flow boiling heat transfer coefficients. Moreover, the mean bubble departure diameter and active nucleation site density are reduced for rises in the FC-72 mass flux and inlet liquid subcooling. Increasing coolant mass flux or reducing inlet liquid subcooling results in a higher mean bubble departure frequency. Furthermore, larger bubble departure diameter, higher bubble departure frequency, and higher active nucleation site density are observed as the imposed heat flux is increased. Finally, empirical correlations for the present data for the heat transfer and bubble characteristics in the FC-72 subcooled flow boiling are proposed.  相似文献   

19.
An experimental study of the heater size effect on micro boiling is reported in detail. Using a 1.66-ms-wide heating pulse, boiling in subcooled water was investigated on a series of micron/submicron thin film Pt heaters with various feature sizes ranging from 0.5 μm to 70 μm. It was found that there existed a critical heater size (10 μm): single spherical bubble generation with heater’s feature size less than 10 μm; oblate vapor blanket on the heater surface with the size larger than 10 μm. The bubble dynamics was studied by the visualization of the bubble nucleation process with a high-speed CCD. The onset bubble nucleation temperature was measured by using each Pt heater as a resistive temperature sensor. The formation of the oblate vapor blanket was attributed to the condensation effect of the vapor outside the superheated zone. The analysis was further validated by generating spherical bubble on heater with size larger than 10 μm with a longer heating pulse.  相似文献   

20.
The boiling heat transfer of refrigerant R-134a flow in horizontal small-diameter tubes with inner diameter of 0.51, 1.12, and 3.1 mm was experimentally investigated. Local heat transfer coefficient and pressure drop were measured for a heat flux ranging from 5 to 39 kW/m2, mass flux from 150 to 450 kg/m2 s, evaporating temperature from 278.15 to 288.15 K, and inlet vapor quality from 0 to 0.2. Flow patterns were observed by using a high-speed video camera through a sight glass at the entrance of an evaporator. Results showed that with decreasing tube diameter, the local heat transfer coefficient starts decreasing at lower vapor quality. Although the effect of mass flux on the local heat transfer coefficient decreased with decreasing tube diameter, the effect of heat flux was strong in all three tubes. The measured pressure drop for the 3.1-mm-ID tube agreed well with that predicted by the Lockhart–Martinelli correlation, but when the inner tube diameter was 0.51 mm, the measured pressure drop agreed well with that predicted by the homogenous pressure drop model. With decreasing tube diameter, the flow inside a tube approached homogeneous flow. The contribution of forced convective evaporation to the boiling heat transfer decreases with decreasing the inner tube diameter.  相似文献   