首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The breakage of overhead covered conductors on distribution lines resulting from the short-circuit arcs caused by lightning flash becomes a challenge as the application of covered conductors increases on distribution lines. Based on various methodologies and devices developed to avoid the covered conductor breakage in the world, novel arc-guided devices, including arcing protection hardware with barbs, clamping post composite insulator, and barb electrode clamping post porcelain/composite insulator are presented in this paper. Experimental results are also presented to validate these new developed devices. Devices based on the developed technologies have been widely applied on the power grids in China successfully.  相似文献   

2.
分析了我国当前配电网分支线保护配置方案及其对用户年平均停电损失的影响,为降低用户年平均停电损失,提出一种分支线保护选配方法。该方法将分支线路分为3类,综合考虑分支线路负荷容量、长度等因素,通过比较配置不同保护时的用户年平均停电损失,选取最优配置方案,为现场选配分支线保护提供技术支持。为方便现场使用,对选配方法进行合理的简化处理,并通过实例分析验证了该选配方法能够有效减少用户年平均停电损失。  相似文献   

3.
近年来,不断发生的输电线路外力破坏事故严重威胁着电网的安全运行,研究开发有效的防外力破坏装置是解决问题的关键.结合外力破坏类型对我国现阶段输电线路外力破坏现状进行了概述,分析了各种防外力破坏监测装置中应用的监测技术,讨论了相关技术的特点,提出了基于智能监测技术的综合监测模型.最后通过实际案例说明如何选择、安装防外力破坏装置,同时对防外力破坏监测技术的发展提出了相关建议.  相似文献   

4.
本文详细讨论了经实践证明非常有效的高压输电线路防冰雪措施——防冰球和防冰环的作用原理与设计。并从复冰和积雪的形成机理,防冰球和防冰环的受力分析等几个方面进行了定性和定量分析,据此推出了防冰球和防冰环的设计公式。  相似文献   

5.
在分析分布式电源不同的短路特性的基础上,提出了利用自适应速断保护和故障分量保护作为分布式发电系统的保护方案,故障发生后,首先利用自适应速断保护,通过故障信息算出系统等效阻抗,同时判断出故障类型,代入自适应速断整定公式,设定速断动作阈值;其次,当自适应速断保护不满足动作要求时,利用故障前后电流,算出故障分量电流,以故障电流作为后备保护。本方案只需对传统保护进行软件升级,无需增添任何硬件成本,完全实现无通道线路保护,且当某个保护元件失灵时仍可保证跳开故障线路。通过对正常运行系统和孤岛进行仿真,结果证明了该方法的可靠性和可行性。  相似文献   

6.
城市配电线路绝缘化和防雷措施   总被引:2,自引:0,他引:2  
介绍了我国北京及日本等地城市配电线路换为绝缘线后发生的雷击断线事故 ,从理论上对雷击绝缘线断线的原因进行了分析 ,并以模拟试验对理论分析进行了验证和计算。证实了配电线路换为绝缘线后 ,如不采取相应的防雷措施 ,绝缘线断线事故会大幅上升。建议采取提高绝缘子的 50 %的放电电压 ,或按一定间距装置杆上避雷器或放电间隙等办法以起到避雷作用 ,以减少事故的发生  相似文献   

7.
差异化的防雷措施在输电线路中得到了广泛应用,取得了良好的效果。而由于配电线路在结构特点、防雷设置等方面与输电线路存在较大差异,差异化防雷措施在配电线路中的应用需要进行一定的修正。通过分析,认为差异化防雷措施在配电线路中应用首先应针对单条线路进行雷害风险评估,继而提出了针对性的防雷措施,特殊条件下输电线路中的防雷措施也可借鉴用于配电线路防雷。  相似文献   

8.
冯大千 《广西电力》2007,30(4):58-61
对各电压等级电力线路避雷特性进行了分析,对提高架空电力线路耐雷水平的可能性与可行性进行了技术探讨,提出了有见地的建议。  相似文献   

9.
袁超 《电气自动化》2021,43(2):9-10,37
由照明灯杆发展而来的综合杆作为道路杆上设施搭载平台,搭载监控设施、信号灯和交通标志等.杆体与人接触的几率远远高于照明灯杆,综合杆配电线路的故障防护必须受到重视.探讨TN-S系统和TT系统综合杆配电线路的故障防护方案,对配电电缆规格、保护电器参数和配电线路长度的选择提出建议,确保综合杆的正常运行及人身安全.实例分析为综合...  相似文献   

10.
矿山电网漏电保护的研究   总被引:3,自引:0,他引:3  
陈奎  陈士军  唐轶 《电气应用》2004,(11):61-64
分析了矿山电网供电的特点 ,给出了附加直流电源的电流与系统绝缘电阻的关系 ,系统正常运行与漏电故障时导纳的变化。提出了基于附加直流电源和导纳 (有功导纳 )增量原理的漏电保护新判据。介绍了基于这些原理的微机漏电保护装置 ,经现场运行表明选线准确、可靠。  相似文献   

11.
胡延东 《电气开关》2011,(5):47-49,54
介绍了应用在煤矿井下各种漏电保护的原理和特点,分析了漏电故障的电气特征,指出了各种漏电保护的应用条件和使用中存在的问题。  相似文献   

12.
配电线路雷击跳闸事故主要由感应雷过电压引起,目前线路的雷电防护常采用装设线路型避雷器和保护间隙。为了评估线路防雷措施的雷电防护效果,采用H覬idalen的仿真计算模块,搭建10 k V配电线路感应雷过电压的仿真模型并仿真线路的感应雷过电压幅值及其沿线分布,确定感应雷过电压最严重时的工况条件,并仿真研究了装设避雷器及保护间隙对线路感应雷过电压防护作用以及安装密度不同时线路感应雷过电压的影响。  相似文献   

13.
Covered conductors have been widely used on overhead distribution lines, and are very easily broken by short-circuit arcs caused by direct lightning strokes or lightning induced overvoltages. The analysis and comparison of all measures and devices to prevent breakage of covered conductors applied in different countries are presented. All of these methods are classified into three categories according to their operation principles, and according to their functions, these methods are summarized into the arc-blocked method and the arc-guided method.  相似文献   

14.
阐述了配电变压器防雷接线的特点,分析了配电系统中过电压产生的机理,指出了配电系统防雷保护存在的主要问题,提出了几种主要的防雷保护措施.  相似文献   

15.
由于10kV配电网结构差异性大,配电线路保护整定值在依据规范的保护整定计算方法基础上,还需要根据具体情况,作一些特殊的考虑,以满足保护可靠性、速动性、选择性、灵敏性的要求。介绍了通过多年实践摸索出的、针对不同电网10kV配电线路的、综合考虑多种因素实用并可靠的保护整定方法。  相似文献   

16.
介绍了10kV智能型配电开关的实际运用效果,分析了10kV智能型配电开关在配电线路中的保护数据,并通过对接地保护、速断保护、过流保护的动作次数及分布进行归类统计和分析,结果表明:智能型配电开关在配电自动化线路应用后所带来的供电可靠性提高、管理水平提升等积极效果,解决了传统开关设备无法监测、故障人工查找时间长、停电面积大的缺点。  相似文献   

17.
针对太原市供电架空线路入地改造工程中施工细节、设计变更、管理协调等方面存在及可能涉及的问题进行了总结和分析,并且提出了解决问题的原则和办法.  相似文献   

18.
针对配电网的特点和故障定位的难题,对传统的故障定位方法进行了分析。在总结这些方法的基础上,提出了利用多种信息来构造一种基于行波-直流法的综合定位方法。本文在深入研究C型行波定位法的基础上,为了更明确地确定故障的具体位置,提出了采用直流注入法作为补充的行波-直流综合故障定位方法,其目的是利用不同方法的互补性来提高故障定位的准确性。该方法分2步进行定位,首先利用C型行波法确定故障距离,然后利用直流法确定故障分支。这种行波-直流综合故障定位方法充分利用了行波法[1]操作简单、定位速度快,以及直流定位法应用范围广、能准确确定故障分支的优点,可以实现精确故障定位。理论分析和ATP仿真结果表明:综合方法不受网络结构、分布电容和线路参数的影响,能够准确地确定配电网单相接地故障位置。  相似文献   

19.
花瓣形配电网具有高可靠供电的特点,其拓扑结构比传统的配电网更加复杂.针对联络线后备保护在变电站附近故障时隔离时间较长的问题,提出了一种新的后备保护方案.首先利用多端差动保护的思想判别出故障联络线所在的花瓣环,再根据各段联络线有功功率的变化趋势判断故障联络线,从而触发断路器跳闸隔离故障,并研究了主保护与后备保护的配合问题...  相似文献   

20.
孔佳琦  夏志坚 《电气开关》2020,(2):62-67,71
耐雷水平低、雷击跳闸率高的配电网是电网防雷的薄弱环节。本文为了研究HALPGD改善35kV配电线路的防雷效果,首先应用电磁暂态计算程序(electromagnetic transient program,EMTP)对安装了HALPGD的广西钦州某典型35kV配电线路的耐雷水平进行了仿真分析,分析得到在有、无避雷线情况下,1基塔、3基塔、5基塔装设HALPGD后线路耐雷水平最高可分别提高1.9倍、8.9倍和12.6倍及分别提高2.2倍、6.9倍和9.8倍;其次,基于规程法建立相应的雷击跳闸率数学模型,并结合该条线路相关参数进行计算,得出在有、无HALPGD条件下年平均雷击跳闸次数为分别为0.0742次/(100km·a)和3.668次/(100km·a),降低幅度达到97.98%,最后与实际监测雷击跳闸率数据(实际二者为0.5303次/(100km·a和4.08次/(100km·a))进行对比,分析可知计算结果与实际几乎相同。最终充分验证HALPGD一定程度上提高了线路的防雷效果。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏