共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
Hydrostatic leveling system(HLS) is widely used in precision engineering survey,especially the alignment of particle accelerator,and the tidal effects on the measurement accuracy of HLS is non-ignorable.thus studies on tidal effects on the HLS is vital.A set of HLS was installed in Jingxian seismostation for verifying the methods to handle the tidal effects on the readings of HLS.Harmonic analysis of the data recorded by HLS and DSQ water tube clinometers in Jingxian seismostation and contrastive analysis of the results are completed.The tilt tide can be well reflected in the data of the both instruments and the results are both reliable.The reasons of the difference between the results are analyzed in this paper.Besides,a validation study based on the measurement data of the HLS used in SPring-8 storage ring for tidal correction on the reading of HLS is completed.The research establishes a foundation for HLS to be applied in micron-level precision alignment of particle accelerator in the future. 相似文献
3.
4.
5.
本文搭建了一套由温湿度传感器、激光位移传感器、高精度位移平台组成的实验系统。采用控制变量法,分别以环境因素及位移为变量,对固定在同一位移平台的静力水准系统(HLS)与线位置探测器(WPS)进行两组实验。实验结果表明:温度是影响HLS测量精度的主要因素,通过温度补偿,可得到较为精确的结果;湿度变化改变张紧线的下垂量,从而影响WPS的测量精度。在环境稳定的情况下,WPS与HLS对同一点的测量结果差值的均方根误差最大为0.003 37 mm,在误差允许范围内,因此两者可组合使用。 相似文献
6.
压力和温度对静力水准系统精度影响分析 总被引:1,自引:1,他引:1
静力水准系统(Hydrostatic leveling system,HLS)的工作介质是液体.由于纯净水的诸多优点,在本系统中采用水作为工作介质.液体的特性是极易受到外界的影响而改变它的物理形态.在HLS系统中,压力、温度等因素对系统的测量有着非常大的影响.本文分别分析了压力和温度对静力水准系统测量精度的影响.为了消除压力的影响,在系统设计的时候采用了密封钵体和钵体之间用等压气管连接的办法,保证系统在工作时每个钵体中的工作液体表面上的大气压是一致的.温度的影响包括水管中温度梯度的影响和钵体之间温度差异的影响.通过分析,对于水管中温度梯度的影响,只要在安装系统时保证水管的垂直高差足够小,就可以忽略;而对于钵体之间的温度差异的影响,在每个钵体传感器中都安装了温度传感器,实时地测量钵体的温度,并和CCD测量数据同时采集,通过理论计算得到温度修正公式,对每个钵体中的CCD读数进行温度修正.通过实验数据分析,可以把温度的影响修正到允许的误差范围以内. 相似文献
7.
8.
The site of Shanghai Synchrotron Radiation Facility (SSRF) is of complicated geological conditions, and a system to monitor the uneven subsidence of foundation and key parts (different kinds of magnets) of the accelerators is a necessity. Considering actual conditions of the accelerator structure and the assembling place, a new type of sensor of hydrostatic levelling system (HLS) has been designed. In order to obtain the required measurement accuracy, every HLS's sensor was strictly calibrated. In this paper, we introduce the special calibration method to establish the HLS. The method has been used in the calibration for vessel sensor for SSRF. 相似文献
9.
合肥光源原有的辐射监测系统是为衰减运行模式而设计建造的。为了更好地促进用户实验的科研产出,合肥光源正在进行恒流运行关键系统改造。在改造中,为了保障实验人员和设备的安全,根据恒流运行要求增加了辐射剂量监测点和完善了安全联锁功能。系统基于EPICS开发,由探测器、通讯模块、数据采集监测软件、数据分析系统等组成。该系统既能监测光源区及周边的辐射剂量率水平,还具备计算积分剂量、历史剂量查询以及必要的安全联锁等功能。新系统已经运行三个多月,系统稳定可靠,能很好地满足合肥光源恒流运行模式对辐射监测的要求。 相似文献
10.
11.
The Hefei light source(HLS) has been upgraded into HLS II, with increased brightness and stability. In this paper, the new injection system is described. Elegant program is used to simulate the particles motion in 6D phase space. In the process of tracking simulation of electrons, the system tolerances and magnet errors are introduced. Influences to the injection efficiency from beam injection deviation are studied. These provide important reference for realizing the Top-up injection. 相似文献
12.
13.
In this paper,the nature and origin of single event effects (SEE) are studied by injecting laser pulses into different circuit blocks,combining with analysis to map pulse width modulators circuitry in the microchip die.A time-domain error-identification method is used in the temporal characteristic analysis of SEE.SEE signatures of different injection times are compared.More serious SEE are observed when the laser shot occurs on a rising edge of the device output for blocks of the error amplifier,current sense comparator,and T and SR latches. 相似文献
14.
15.
16.
During the Phase II project of NSRL, a turn by turn BPM (Beam Position Monitor) system is proposed for storage ring diagnostics which engages log-ratio electronics circuit to measure machine properties of the HLS (Hefei Light Source) storage ring. The log-ratio processor works at 408 MHz, twice the RF frequency of HLS. Modern logarithmic amplifiers with wide dynamic range, great bandwidth, good logarithmic conformance, and low cost are attractive for beam position measurements. Injection kicker and the stripline-electrode resonant exciting methods are used to excite beam for nonlinear beam dynamics and phase space studies of stored beam. Up to 2 seconds of data acquisition is ensured. In this paper we present the performance of each component and preliminary test results of the turn-by-turn BPM system. 相似文献
17.
A new beam-based alignment (BBA) measurement system with AC k-modulation module was developed recently at Hefei Light Source (HLS), which equipped the quadrupole magnets on the storage ring with a current shunt system which was able to vary the magnet current of a given quadrupole at a given frequency. The corresponding closed orbit oscillation amplitude measured for different beam positions in the quadrupole reached a minimum when the beam was centered in the quadrupole. Amplitude estimation algorithms of software lock-in amplifier and interpolated FFT were discussed. A V-shaped curve was used to determine the offset; a method using a parabola fit to determine the offset was also discussed. This BPM-to-quadrupole offset was determined at HLS with an accuracy of ~50 mum. The reproducibility of the beam based alignment using this technique is about 20 mum (RMS) 相似文献
18.
19.
Beam instrumentation and diagnostics for HLS 总被引:1,自引:0,他引:1
The beam diagnostic instrumentation for the Heifei Light Source(HLS) is described ,It provides sufficient parameters for machine study during the commisioning and common operation.The measured results are presented. 相似文献
20.
XIAO Yunyun SUN Baogen GU Liming LU Ping WANG Jigang TANG Leilei YANG Yongliang ZHOU Zeran XU Hongliang 《核技术(英文版)》2012,(2):70-74
As an important part of the beam diagnostic system, the synchrotron light beam position measurement has a very high value in the high quality and high stability light source applied research. A new photon beam position monitor based on position-sensitive detector (PSD) has been developed to measure the photon beam position in vertical and horizontal directions at the same time at HLS (Hefei Light Source). The new PBPM based on the PSD has fast response speed, high sensitivity and wide dynamic range. This PBPM system also includes the C4674 signal processing circuit, NI USB-9215 data acquisition device and the LABVIEW data acquisition program. This PBPM system has been calibrated vertically and horizontally on-line, and then has been applied in the beam line B3EA of HLS to measure the position of the synchrotron light. As the results shown, the resolution of the system is better than 3 mm. 相似文献