共查询到19条相似文献,搜索用时 156 毫秒
1.
2.
土壤样品以HNO3(5.0mL)-HF(4.0mL)-H2O2(1.0mL)在一定的温度和时间下微波消解处理后,用火焰原子吸收光谱法测定样品中铜、铅、锌、镉及镍元素含量.在最佳工作条件下测定各金属元素含量,各元素的加标回收率在95.8%~103.4%之间,标准工作曲线的线性相关系数均大于0.99,该方法测定结果的相对标... 相似文献
3.
4.
建立了微波消解-原子吸收分光光度法测定土壤中痕量铜、锌、铅、镍、铬的方法。优化微波消解条件,通过硝酸-盐酸-氢氟酸-高氯酸体系消解液对土壤样品进行消解,样品经消解浓缩后定容至5 mL,在仪器最佳的条件进行测定。结果表明:铜、锌、铅、镍、铬5种金属元素均呈现良好的线性关系,相关系数范围为0.999 3~0.999 9,检出限范围分别为0.5,1.0,6.0,1.2,0.7 mg/kg,测定下限分别为2.0,4.0,24.0,4.8,2.8 mg/kg,平均回收率范围为86.8%~109%,相对偏差范围在2.67%~5.78%。该方法稳定性好,操作简单,灵敏度高,满足土壤中铜、锌、铅、镍、铬测定。 相似文献
5.
微波消解-石墨炉原子吸收法测软胶囊中的铅 总被引:1,自引:0,他引:1
文章采用了微波消解处理样品,研究了石墨炉原子吸收光谱法测定软胶囊中铅的适宜条件,建立了石墨炉原子吸收光谱法测定软胶囊中铅的方法.利用标准加入法和塞曼效应校正背景,铅的线性范围为0~50μg/L,回收率为90%~110%. 相似文献
6.
7.
原子吸收光谱法测定精四氯化钛中铁铜镍铅 总被引:1,自引:1,他引:0
为了快速准确地测定精四氯化钛中铁、铜、镍、铅含量,采用火焰原子吸收光谱法测定,用盐酸直接溶解样品,用标准加入法测定。测定铁、铜、镍、铅最佳实验条件为:灯电流分别为7,6,7,7 mA;燃烧器高度分别为11,12,12,12 mm;狭缝宽分别为0.2,0.4,0.4,0.4 nm;V乙炔/V空气(以下简称燃助比)分别为1/6,1.5/6,1.5/6,2/8。方法的检出限量:铁为0.098μg/mL,铜为0.082μg/mL,镍为0.064μg/mL,铅为0.121μg/mL。研究结果表明:盐酸直接溶样能减少样品的污染,加标回收率为97%~103%,相对标准偏差小于3%。方法简便、快速、准确。 相似文献
8.
9.
10.
采用微波消解-火焰原子吸收光谱法测定阿胶中铜的含量。微波消解阿胶样品具有方便、快捷、污染少特点,并且可以完全消解样品;方法考查了8种牌号的阿胶产品,方法检出限为0.006μg/mL,方法的加标回收率97.8%~108.0%,相对标准偏差小于2%,结果令人满意。 相似文献
11.
罗汉果中含有丰富的营养物质,分析其中的微量元素的含量,对于指导人们的健康饮食具有十分重要的意义。本文研究了用微波消解-ICP-AES对罗汉果中Cu、 Zn、 Fe、 Mn、 Na、 Ca 6种元素进行测定的方法。优化了ICP-AES的工作参数,考察了消解液的种类及用量对测定结果的影响,选择消解液为 HNO3:HClO4=10:3(φ)。六种元素的检出限在0.005~0.021μg/mL之间,相对标准偏差( RSD)均小于8%,回收率为95.7%~103.4%。该方法用于罗汉果中微量元素的测定,结果令人满意。 相似文献
12.
Determination of copper, lead, and nickel in edible oils by plasma and furnace atomic spectroscopies
Lori B. Allen Paul H. Siitonen Harold C. Thompson Jr. 《Journal of the American Oil Chemists' Society》1998,75(4):477-481
An atmospheric pressure microwave digestion procedure is described for the determination of copper, lead, and nickel in edible
oils. The digestion procedure is compatible with either inductively coupled plasma atomic emission spectrometry (ICP-AES)
or graphite furnace atomic absorption spectrometry (GFAAS). Instrument conditions are specified to allow the simultaneous
determination of all three metals for each sample introduction. Method detection limits were element-specific but equal to
or less than 50 ng/g with ICP-AES and 30 ng/g with GFAAS. Results from spike and recovery experiments at levels of 50, 100,
and 200 ng/g are reported for corn and soybean oil. For soybean oil, recoveries at 100 ng/g were 90, 100, and 106%, respectively,
for copper, lead, and nickel with ICP-AES, and 89, 106, and 96%, respectively, with GFAAS. Recoveries for corn oil spiked
at 100 ng/g were 93, 95, and 103%, respectively, for copper, lead, and nickel with ICP-AES, and 90, 117, and 100%, respectively,
with GFAAS. Day-to-day reproducibility was demonstrated by similar method recoveries and reproducibilities in independent
analysis of two canola oil sample sets that were spiked at 100 ng/g. 相似文献
13.
比较了火焰原子吸收光谱法测定指甲中钙的两种前处理方法。样品分别采用非完全消化法与微波消解法进行前处理,研究了钙的最佳工作条件,且考察了释放剂硝酸锶的影响。两种方法测得钙含量基本一致,相对误差小于0.94%。方法检出限分别为0.04μg/mL、0.03μg/mL,相对标准偏差分别为1.75%、1.05%。两种方法测定钙的结果都令人满意,非完全消化法速度快,微波消解法灵敏度较高,可根据实际情况选择前处理方法。 相似文献
14.
采用火焰法、石墨炉法,样品消解后直接测定中药材丹参、白芍中重金属铜、铅、镉的含量。结果表明:重金属铜在0~0.8μg/mL、铅在0~80μg/L、镉在0~0.8μg/L范围线性关系良好,相关系数分别为0.995 6、0.996 3、0.999 4;丹参、白芍中所含铜、铅、镉均符合《中国药典》规定。本法简单、快速、灵敏,适用于中药材中微量重金属的测定,结果满意。 相似文献
15.
16.
铜离子与1-(2-吡啶偶氮)-2-萘酚(PAN)反应,生成疏水性的络合物,在助溶剂乙醇的作用下,被萃取到三氯甲烷相中,用分光光度法测定三氯甲烷相中的Cu2+-PAN,建立了析相富集-分光光度法测定水样中痕量铜的分析方法。对影响络合反应和相分离的各种条件进行了优化。在选择的实验条件下,铜的质量浓度在0.50~15μg/mL范围内与吸光度呈线性关系,相关系数为0.999 57,方法的检出限为0.089μg/mL,对铜浓度为5.0μg/mL的样品溶液进行7次平行测定,相对标准偏差为1.67%。该方法用于水样中铜的测定,回收率在95.6%~101.5%之间。 相似文献
17.
18.