Frequency regulation in a generation mix having large wind power penetration is a critical issue, as wind units isolate from the grid during disturbances with advanced power electronics controllers and reduce equivalent system inertia. Thus, it is important that wind turbines also contribute to system frequency control. This paper examines the dynamic contribution of doubly fed induction generator (DFIG)-based wind turbine in system frequency regulation. The modified inertial support scheme is proposed which helps the DFIG to provide the short term transient active power support to the grid during transients and arrests the fall in frequency. The frequency deviation is considered by the controller to provide the inertial control. An additional reference power output is used which helps the DFIG to release kinetic energy stored in rotating masses of the turbine. The optimal speed control parameters have been used for the DFIG to increases its participation in frequency control. The simulations carried out in a two-area interconnected power system demonstrate the contribution of the DFIG in load frequency control.  相似文献   

2.
文章在传统转子动能虚拟惯性控制策略基础上,提出了一种考虑直流侧电容存储能量的风电机组虚拟惯性控制策略。该策略在建立转子动能和系统频率偏差关系的基础上,建立了风电变流器直流侧电容电压和系统频率偏差的函数关系,在频率事件下能够充分利用电容所存储的能量来增强电网的惯性,提高电网的频率调节能力。最后,通过PSCAD/EMTDC仿真验证了所提控制策略的有效性。  相似文献   

3.
Among the available options for renewable energy integration in existing power system, wind power is being considered as one of the suited options for future electrical power generation. The major constraint of wind power generating system (WPGS) is that it does not provide inertial support because of power electronic converters between the grid and the WPGS to facilitate frequency stabilization. The proposed control strategy suggests a substantial contribution to system inertia in terms of short-term active power support in a two area restructured power system. The control scheme uses fuzzy logic based design and takes frequency deviation as input to provide quick active power support, which balances the drop in frequency and tie-line power during transient conditions. This paper presents a comprehensive study of the wind power impact with increasing wind power penetration on frequency stabilization in restructured power system scenario. Variation of load conditions are also analyzed in simulation studies for the same power system model with the proposed control scheme. Simulation results advocates the justification of control scheme over other schemes.  相似文献   

4.
为解决大规模风电并网带来的系统频率稳定性降低问题,风电机组通过虚拟惯量控制可为系统提供短期频率支撑,然而惯性响应期间风电机组转速收敛缓慢,导致一部分转子动能被无故浪费;转速恢复阶段的有功突变易造成频率二次跌落。为此,提出基于转矩极限的改进风电机组虚拟惯量控制策略,实现在释放较少动能的前提下提供与传统策略相同的频率响应服务;并在频率步入准稳态时,借助时变功率函数开始转速恢复,实现转速快速恢复的同时缓解二次频率跌落。基于EMTP-RV仿真软件搭建包含风电场的电力系统模型,验证了所提策略的有效性。  相似文献   

5.
Among the several wind generation technologies, variable-speed wind turbines utilizing doubly fed induction generators (DFIG) are gaining momentum in the power industry. Increased penetration of these wind turbine generators displaces conventional synchronous generators which results in erosion of system frequency. With this assertion, the paper analyzes the dynamic participation of DFIG for frequency control of an interconnected two-area power system in restructured competitive electricity market. Frequency control support function responding proportionally to frequency deviation is proposed to take out the kinetic energy of wind turbine for improving the frequency response of the system. Impacts of varying wind penetration in the system and varying active power support from DFIG on frequency control have been investigated. The presence of thyristor controlled phase shifter (TCPS) in series with the tie-line and Superconducting Magnetic Energy Storage (SMES) at the terminal of one area in conjunction with dynamic active power support from DFIG results in optimal transient performance for PoolCo transactions. Integral gains of AGC loop and parameters of TCPS and SMES are optimized through craziness-based particle swarm optimization (CRPSO) in order to have optimal transient responses of area frequencies, tie-line power deviation and DFIG parameters.  相似文献   

6.
This paper investigates the physical capability of double‐fed induction generator (DFIG) wind turbines for inertial support of frequency response. Frequency stability is modeled using the DFIG electromechanical and generator controller dynamics, and a destabilizing effect is demonstrated in low‐inertia systems. To improve response, a synchronous reference frame DFIG controller is proposed that acts by following low‐frequency grid dynamics and adds a fast acting proportional plus integral (PI)‐controlled frequency‐responsive component to existing qd current commands. The proposed controller is derived in a straightforward manner using only the DFIG dynamic equations and is designed using pole/zero placement techniques. Laboratory experiments using a micro‐scale DFIG wind turbine with hub‐emulating flywheel prove better capability for transient frequency regulation even under extreme load change. The result is a DFIG controller that balances the appearance of transients in electrical and mechanical systems. Value is achieved in providing immediate continuous inertial response to support load change. The proposed frequency response can improve the use of existing physical inertia from wind turbines.  相似文献   

7.
Throughout Europe there is an increasing trend of connecting high penetrations of wind turbines to the transmission networks. This has resulted in transmission system operators revising their grid code documents for the connection of large wind farms. These specifications require large MW capacity wind farms to have the ability to assist in some of the power system control services currently carried out by conventional synchronous generation. These services include voltage and frequency control. It is now recognized that much of this new wind generation plant will use either fixed speed induction generator (FSIG)‐ or doubly fed induction generator (DFIG)‐based wind turbines. The addition of a control loop to synthesize inertia in the DFIG wind turbine using the power electronic control system has been described. The possibility of deloading wind turbines for frequency response using blade pitch angle control is discussed. A pitch control scheme to provide frequency response from FSIG and DFIG wind turbines is also described. A case study of an FSIG wind turbine with frequency response capabilities is investigated. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

8.
Frequency support from doubly fed induction generator wind turbines   总被引:2,自引:0,他引:2  
An assessment on the capability of a doubly fed induction generator (DFIG) wind turbine for frequency regulation is presented. Detailed aerodynamic, structural and electrical dynamic models were used in this study. A control loop acting on the frequency deviation was added to the inertia contributing loop in order to enhance the inertia support from the DFIG wind turbine. The possibility of de-loading a wind turbine to provide primary and secondary frequency response was discussed. A frequency droop controller was examined where the droop is operating on the electronic torque set point below its maximum speed and is operating on the pitch demand at maximum speed. It is also shown that by reducing the generator torque set point the DFIG wind turbine can provide high frequency response  相似文献   

9.
针对风光并网会降低系统惯量、削弱系统调频能力的问题,综合考虑水电机组同步惯量、风电场和光伏电站的虚拟惯量和下垂控制作用,提出含风光水的多机系统动态频率响应模型,推导系统频率变化率约束、最低点频率偏差约束和准稳态频率偏差约束。基于此,为实现清洁能源利用最大化,以弃风、弃光、弃水最小及水库调度期末蓄能最大为目标,兼顾梯级水电、风电、光伏和发电系统的多种运行约束,构建风光水互补发电系统短期优化调度模型,并使用混合整数线性规划方法进行求解。最后通过算例仿真验证所提模型的有效性和适用性。  相似文献   

10.
Emphasis in this article is on the design of a co‐ordinated voltage control strategy for doubly fed induction generator (DFIG) wind turbines that enhances their capability to provide grid support during grid faults. In contrast to its very good performance in normal operation, the DFIG wind turbine concept is quite sensitive to grid faults and requires special power converter protection. The fault ride‐through and grid support capabilities of the DFIG address therefore primarily the design of DFIG wind turbine control with special focus on power converter protection and voltage control issues. A voltage control strategy is designed and implemented in this article, based on the idea that both converters of the DFIG (i.e. rotor‐side converter and grid‐side converter) participate in the grid voltage control in a co‐ordinated manner. By default the grid voltage is controlled by the rotor‐side converter as long as it is not blocked by the protection system, otherwise the grid‐side converter takes over the voltage control. Moreover, the article presents a DFIG wind farm model equipped with a grid fault protection system and the described co‐ordinated voltage control. The whole DFIG wind farm model is implemented in the power system simulation toolbox PowerFactory DIgSILENT. The DFIG wind farm ride‐through capability and contribution to voltage control in the power system are assessed and discussed by means of simulations with the use of a transmission power system generic model developed and delivered by the Danish Transmission System Operator Energinet.dk. The simulation results show how a DFIG wind farm equipped with voltage control can help a nearby active stall wind farm to ride through a grid fault, without implementation of any additional ride‐through control strategy in the active stall wind farm. Copyright © 2006 John Wiley &Sons, Ltd.  相似文献   

11.
汪正军  高静方  赵冰  丁亮  曹扬 《太阳能学报》2022,43(10):138-143
针对现有风电场虚拟惯量协调控制在风电机组调频辅助功率协调分配方面的研究,提出一种基于风速预测的风电场虚拟惯量响应场级协同分配策略,具体是通过经验模式分解(EMD)和BP神经网络训练风速时序序列获得风速时序模型,预测短时段内的风速,根据实时转速和预测风速计算惯量分配权重因子,根据频率变化计算全场惯量响应值,通过惯量分配权重因子结合变流器容量限值给单机分配惯量响应值。该控制策略成功应用于云南某148.5 MW风电场站级调频测试,验证了算法的有效性。  相似文献   

12.
Synchronous and fixed-speed induction generators release the kinetic energy of their rotating mass when the power system frequency is reduced. In the case of doubly fed induction generator (DFIG)-based wind turbines, their control system operates to apply a restraining torque to the rotor according to a predetermined curve with respect to the rotor speed. This control system is not based on the power system frequency and there is negligible contribution to the inertia of the power system. A DFIG control system was modified to introduce inertia response to the DFIG wind turbine. Simulations were used to show that with the proposed control system, the DFIG wind turbine can supply considerably greater kinetic energy than a fixed-speed wind turbine.  相似文献   

13.
The purpose of this paper is to improve the control performance of the variable speed, constant frequency doubly-fed induction generator in the wind turbine generation system by using fuzzy logic controllers. The control of the rotor-side converter is realized by stator flux oriented control, whereas the control of the grid-side converter is performed by a control strategy based on grid voltage orientation to maintain the DC-link voltage stability. An intelligent fuzzy inference system is proposed as an alternative of the conventional proportional and integral (PI) controller to overcome any disturbance, such as fast wind speed variation, short grid voltage fault, parameter variations and so on. Five fuzzy logic controllers are used in the rotor side converter (RSC) for maximum power point tracking (MPPT) algorithm, active and reactive power control loops, and another two fuzzy logic controllers for direct and quadratic rotor currents components control loops. The performances have been tested on 1.5 MW doubly-fed induction generator (DFIG) in a Matlab/Simulink software environment.  相似文献   

14.
With increasing wind power penetration, transient responses of doubly-fed-induction-generator (DFIG) based wind turbines gain attentive focus. Accurate prediction of transient performance of DFIG under grid faults is required with increasing wind power penetration. Taking into account the main flux saturation and deep-bar effect, this paper concentrates on transient responses and stability of the DFIG system under symmetrical grid faults. Their roles played in the enhancement of system transient stability are clarified. The analyses proposed contribute greatly to proper selection, design and coordination of protection devices and control strategies as well as stability studies.  相似文献   

15.
Increasing levels of wind generation have resulted in an urgent need for the assessment of their impact on frequency control of power systems. The displacement of conventional generation with wind generation will result in erosion of system frequency. The paper analyzed the dynamic participation of doubly fed induction generator (DFIG) to system frequency responses of two-area interconnected power system having variety of conventional generating units. Frequency control support function responding proportionally to frequency deviation is proposed to take out the kinetic energy of turbine blades in order to improve the frequency response of the system. Impacts of different wind penetrations in the system and varying active power support from wind farm on frequency control have been investigated. Integral gains of AGC loop are optimized through craziness-based particle swarm optimization (CRPSO) in order to have optimal transient responses of area frequencies, tie-line power deviation and DFIG parameters.  相似文献   

16.
针对电力系统发生大扰动时,双馈风电机组采用现有下垂控制方法不能充分利用自身旋转动能为电网提供频率响应服务,提出一种计及电网频率偏差的变系数双馈风力发电机组频率控制策略。该方法通过将下垂系数与电网频率偏差耦合,可根据电网频率变化量灵活地调节下垂系数,实现在系统发生大扰动时风电机组更有效地为电力系统提供频率支撑,并借助EMTP-RV仿真平台搭建含高比例风电渗透率的电力系统模型,验证所提控制策略的有效性。仿真结果表明,在不同风速场景下,当电力系统发生不同扰动时,双馈风电机组采用该策略均可有效提升自身频率响应能力,减少系统最大频率偏差,特别是在大扰动场景下,效果更加明显。  相似文献   

17.
Fault ride-through capability of DFIG wind turbines   总被引:2,自引:0,他引:2  
This paper concentrates on the fault ride-through capability of doubly fed induction generator (DFIG) wind turbines. The main attention in the paper is, therefore, drawn to the control of the DFIG wind turbine and of its power converter and to the ability to protect itself without disconnection during grid faults. The paper provides also an overview on the interaction between variable-speed DFIG wind turbines and the power system subjected to disturbances, such as short circuit faults. The dynamic model of DFIG wind turbine includes models for both mechanical components as well as for all electrical components, controllers and for the protection device of DFIG necessary during grid faults. The viewpoint of the paper is to carry out different simulations to provide insight and understanding of the grid fault impact on both DFIG wind turbines and on the power system itself. The dynamic behaviour of DFIG wind turbines during grid faults is simulated and assessed by using a transmission power system generic model developed and delivered by the Danish Transmission System Operator Energinet.dk in the power system simulation toolbox PowerFactory DIgSILENT. The data for the wind turbines are not linked to a specific manufacturer, but are representative for the turbine and generator type used in variable-speed DFIG wind turbines with pitch control.  相似文献   

18.
赵熙临  吴恒  付波  查冰  罗维 《可再生能源》2021,39(3):388-394
文章提出了利用风电输出特征对微电网进行频率控制的方法.该方法首先对电网一、二次调频的双时间尺度特征进行了阐述,分析了风机虚拟惯性与桨距角调整两种输出控制方法,并讨论了此两种方式在时间尺度上与电网一、二次调频的对应关系.在此基础上,设计了风机虚拟惯性参与系统一次调频,桨距角调整参与二次调频的混合频率控制方法.最后以风、光...  相似文献   

19.
Libao Shi  Zheng Xu  Jin Hao  Yixin Ni 《风能》2007,10(4):303-320
This paper shows a model of a doubly fed induction generator (DFIG) including a simplified model of a wind turbine for the purpose of transient stability analysis of large‐scale power systems with great wind farms penetration. The wind turbine model and the DFIG model are systematically deducted in this paper. Specially, the improved model of rotor‐side converter and the simplified grid‐side converter model are considered in our work. The corresponding machine–network interface solution based on the synchronously rotating common x‐y reference frame is elaborately issued in this paper. Furthermore, a method is proposed to calculate the DFIG initial conditions as well. A simplified model of the turbine is used excluding among other components the pitch control. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

20.
A control strategy for compensating AC network voltage unbalance using doubly fed induction generator (DFIG)-based wind farms is presented. A complete DFIG dynamic model containing both the rotor and grid side converters is used to accurately describe the average and ripple components of active/reactive power, electromagnetic torque and DC bus voltage, under unbalanced conditions. The principle of using DFIG systems to compensate grid voltage unbalance by injecting negative sequence current into the AC system is described. The injected negative sequence current can be provided by either the grid side or the rotor side converters. Various methods for coordinating these two converters are discussed and their respective impacts on power and torque oscillations are described. The validity of the proposed control strategy is demonstrated by simulations on a 30 MW DFIG-based wind farm using Matlab/Simulink during 2 and 4% voltage unbalances. The proposed compensation strategy can not only ensure reliable operation of the wind generators by restricting torque, DC link voltage and power oscillations, but also enable DFIG-based wind farms to contribute to rebalancing the connected network.  相似文献   