首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The foundation for saliva-based diagnostics is the development of a complete catalog of secreted proteins detectable in saliva. Besides protein complexity, the greatest bioanalytical challenge facing comprehensive analysis of saliva samples is related to the large variation of protein relative abundances including the presence of high-abundance proteins such as amylases, mucins, proline-rich proteins (PRPs), and secretory IgA complex. Among a number of electrokinetic separation techniques, transient capillary isotachophoresis/capillary zone electrophoresis (CITP/CZE) specifically targets trace amounts of proteins and thus reduces the range of relative protein abundances for providing unparallel advantages toward the identification of low-abundance proteins. By employing a CITP/CZE-based multidimensional separation platform coupled with electrospray ionization-tandem mass spectrometry (ESI-tandem MS), a total of 6112 fully tryptic peptides are sequenced at a 1% false discovery rate (FDR), leading to the identification of 1479 distinct human SwissProt protein entries. By comparing with capillary isoelectric focusing (CIEF) as another electrokinetics-based stacking approach, CITP/CZE not only offers a broad field of application but also is less prone to protein/peptide precipitation during the analysis. The ultrahigh resolving power of CITP/CZE is evidenced by the large number of distinct peptide identifications measured from each CITP fraction together with the low peptide fraction overlapping among identified peptides. Furthermore, when evaluating the protein sequence coverage by the number of distinct peptides mapping to each protein identification, the CITP-based proteome technology similarly achieves the superior performance with 674 proteins (46%) having three or more distinct peptides, 288 (19%) having two distinct peptides, and 517 (35%) having a single distinct peptide.  相似文献   

2.
An integrated proteome concentration/separation approach involving on-line combination of capillary isoelectric focusing (CIEF) with capillary reversed-phase liquid chromatography (CRPLC) is developed for providing significant analyte concentration and extremely high resolving power toward protein and peptide mixtures. Upon completion of analyte focusing, the self-sharpening effect greatly restricts analyte diffusion and contributes to analyte stacking in narrowly focused bands with a concentration factor of approximately 240. In addition to analyte focusing, CIEF as the first separation dimension resolves proteins/peptides on the basis of their differences in pI and offers greater resolving power than that achieved in strong cation exchange chromatography. The grouping of two highly resolving and completely orthogonal separation techniques of CIEF and CRPLC, together with analyte focusing and concentration, significantly enhances the dynamic range and sensitivity of conventional mass spectrometry toward the identification of low-abundance proteins. The CIEF-based multidimensional separation/concentration platform enables the identification of a greater number of yeast soluble proteins than methods presented in the literature, yet requires a protein loading of only 9.6 microg. This protein loading is 2-3 orders of magnitude lower than those employed by the reported non-gel-based proteome techniques. The distribution of a codon adaptation index value for identified yeast proteins approximates to that predicted for the entire yeast proteome and supports the capability of CIEF-based proteome separation technology for achieving comprehensive proteome analysis. By reducing the inner diameter of chromatography columns from 180 microm to 100 microm, the required protein loading is further decreased from 9.6 microg to 960 ng, illustrating the potential usage of this proteome technology for the analysis of protein profiles within small cell populations or limited tissue samples.  相似文献   

3.
This study demonstrates the ability to perform sensitive proteome analysis on the limited protein quantities available through tissue microdissection. Capillary isoelectric focusing combined with nano-reversed-phase liquid chromatography in an automated and integrated platform not only provides systematic resolution of complex peptide mixtures based on their differences in isoelectric point and hydrophobicity but also eliminates peptide loss and analyte dilution. In comparison with strong cation exchange chromatography, the significant advantages of electrokinetic focusing-based separations include high resolving power, high concentration and narrow analyte bands, and effective usage of electrospray ionization-tandem MS toward peptide identifications. Through the use of capillary isoelectric focusing-based multidimensional peptide separations, a total of 6866 fully tryptic peptides were detected, leading to the identification of 1820 distinct proteins. Each distinct protein was identified by at least one distinct peptide sequence. These high mass accuracy and high-confidence identifications were generated from three proteome runs of a single glioblastoma multiforme tissue sample, each run consuming only 10 microg of total protein, an amount corresponding to 20,000 selectively isolated cells. Instead of performing multiple runs of multidimensional separations, the overall peak capacity can be greatly enhanced for mining deeper into tissue proteomics by increasing the number of CIEF fractions without an accompanying increase in sample consumption.  相似文献   

4.
High-efficiency capillary isoelectric focusing of peptides   总被引:6,自引:0,他引:6  
Several approaches are presently being developed for global proteome characterization that are based upon the analysis of polypeptide mixtures resulting from digestion of (often complex) mixtures of proteins. Improved methods for peptide analysis are needed that provide for sample concentration, higher resolution separations, and direct compatibility with mass spectrometry. In this work, methods for the high-efficiency capillary isoelectric focusing (CIEF) separation of peptides have been developed that provide for simultaneous sample concentration and separation according to peptide isoelectric point. Under typical nondenaturing CIEF conditions, peptides are concentrated approximately 500-fold, and peptides present at < 1 ng/ microL were detectable using conventional UV detection. CIEF separations of peptides provided much faster measurements of isoelectric points compared with conventional isoelectric focusing in gels. Very small differences in peptide isoelectric points (deltapI approximately 0.01) could be resolved, High-efficiency CIEF separations for complex peptide mixtures from tryptic digestion of yeast cytosol fractions were obtained and showed significant improvement over those obtained using capillary zone electrophoresis and packed capillary reversed-phase liquid chromatography.  相似文献   

5.
This paper demonstrates a ultraviolet (UV)-embossed polymeric chip for protein separation by capillary isoelectric focusing (CIEF) and identification by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The polymeric chip was replicated by a UV-embossing technique using a soft rubber mold. Five diverse widely investigated families of UV-cured formulations were examined for MALDI ionization efficiency of bovine serum albumin (BSA) samples spotted on the polymer surfaces. The signal and signal-to-noise ratio from the polyester formulation were each 12 times those obtained with PMMA (a commonly used polymer material for MALDI) at picomole sample concentration. A polyester chip was successfully used to carry out CIEF to separate proteins, followed by MALDI-TOF-MS identification. Issues related to the successful chip fabrication and protein separation and identification are discussed.  相似文献   

6.
Capillary isoelectric focusing of yeast cells   总被引:2,自引:0,他引:2  
In the present work, capillary isoelectric focusing (CIEF) methods were developed for the separation and identification of yeast cells. Yeast cells (approximately 4-microm diameter) cultured to various phases of growth were shown to be reproducibly resolved by CIEF using 100-microm-i.d. fused-silica capillaries coated with hydroxypropyl methylcellulose. Separation efficiencies corresponding to peak capacities of >4000 were obtained. The suitable cell concentration range for obtaining repeatable elution in CIEF separations was found to be quite low (<3 cells/microL). CIEF experiments showed that yeast cell populations at early log, mid log, and stationary growth phases differ in isoelectric point, with values ranging from 5.2 to 6.4. The broader application of CIEF are projected for microorganism identification and separation based upon growth conditions.  相似文献   

7.
An integrated gel protein identification technology is developed and demonstrated for the effective ( approximately 90% recovery), rapid (less than 5 min), and sensitive identification (as low as 1 ng gel protein loading) of gel-resolved proteins using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). This integrated technology involves on-line combination of electronic protein transfer with nanoscale proteolytic digestion in a capillary platform, enabling electrokinetic-based protein extraction and stacking, real-time proteolytic cleavage of extracted proteins, and direct deposition of protein digests onto MALDI targets. By revisiting the yeast two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) in similar isoelectric point and molecular mass ranges as studied by Gygi and co-workers (Gygi, S. P.; Corthals, G. L.; Zhang, Y.; Rochon, Y.; Aebersold, R. Proc. Natl. Acad. Sci. U.S.A. 2000, 97, 9390-9395), we are additionally able to identify a large number of low abundance proteins with codon adaptation index (CAI) values of <0.2 and increase the proteome coverage to nearly 50%. The CAI value distribution for identified yeast proteins now more closely approximates that predicted for the entire yeast proteome. We further note that the current single-capillary methodology can be easily expanded to a multiplexed capillary platform as a ultrahigh throughput and greatly effective tool for linking 2-D PAGE with MS, particularly for the analysis of low-abundance proteins.  相似文献   

8.
Zhang Z  Du X  Li X 《Analytical chemistry》2011,83(4):1291-1299
A novel integrated concentration/separation approach involving online combination of sweeping with electrokinetic injection and analyte focusing by micelle collapse (AFMC) with heart-cutting two-dimensional (2D) capillary electrophoresis (CE) in a single capillary was developed for analysis of Herba Leonuri and mouse blood samples. First, a new sweeping with an electrokinetic injection preconcentration method was developed to inject a large volume sample solution and significantly enhance detection sensitivity. Then, the preconcentration scheme was integrated to the 2D-CE to provide significant analyte concentration and extremely high resolving power. The sample was preconcentrated by sweeping with electrokinetic injection and separated in first dimension micellar electrokinetic chromatography (MEKC). Then, only a desirable fraction of the first dimension separation was transferred into the second dimension of the capillary by pressure and further analyzed by capillary zone electrophoresis (CZE) acting as the second dimension. As the key to successful integration of MEKC and CZE, an AFMC step was integrated between the two dimensions to release analytes from the micelle interior to a liquid zone and to overcome the sample zone diffusion caused by mobilization pressure. The injected sample plug lengths for flavonoids under 15 kV for 60 min were experimentally estimated as 546 cm. The dual concentration methods resulted in the increased detection factors of 6000-fold relative to the traditional pressure injection method. The relative standard deviation (RSD) values of peak height, peak area, and migration time were 2.7-4.5%, 1.9-4.3%, and 4.7-6.8% (n = 10), respectively. The limits of detection (S/N = 3) were in the range of 7.3-36.4 ng/L, and the theoretical plate numbers (N) were in the range of 1.7-4.3 × 10(4) plates/m. This method has been successfully applied to determine flavonoids in Herba Leonuri and postdosing mouse blood samples. The pharmacokinetic study also demonstrated that the proposed concentration/separation method was convenient and sensitive and would become an attractively alternative method for online sample concentration and separation in complex samples.  相似文献   

9.
Liu H  Zhang L  Zhu G  Zhang W  Zhang Y 《Analytical chemistry》2004,76(21):6506-6512
The construction and evaluation of an on-column etched fused-silica porous junction for on-line coupling of capillary isoelectric focusing (CIEF) with capillary zone electrophoresis (CZE) are described. Where two separation columns were integrated on a single piece of fused-silica capillary through the etched approximately 4 to 5-mm length porous junction along the capillary. The junction is easily prepared by etching a short section of the capillary wall with HF after removing the polyimide coating. The etched section becomes a porous glass membrane that allows only small ions related to the background electrolyte to pass through when high voltage is applied across the separation capillary. The primary advantages of this novel porous junction interface over previous designs (in which the interface is usually formed by fracturing the capillary followed by connecting the two capillaries with a section of microdialysis hollow fiber membrane) are no dead volume, simplicity, and ruggedness, which is particularly well suited for an on-line coupling capillary electrophoresis-based multiple dimensional separation system. The performance of the 2D CIEF-CZE system constructed by such an etched porous junction was evaluated by the analyses of protein mixtures.  相似文献   

10.
A stepwise mobilization strategy has been developed for the elution of complex protein mixtures, separated by capillary isoelectric focusing (CIEF) for detection using on-line electrospray ionization mass spectrometry (ESI-MS). Carrier polyampholytes are used to establish a pH gradient as well as to control the electroosmotic flow arising from the use of uncoated fused-silica capillaries. Elution of focused protein zones is achieved by controlling the mobilization pressure and voltage, leaving the remaining protein zones focused inside the capillary. Protein zones are stepwise eluted from the capillary by changing the mobilization conditions. Stepwise mobilization improves separation resolution and simplifies coupling with multistage MS (i.e., MSn) analysis since it allows more effective temporal control of protein elution from the CIEF capillary. We also describe a modified configuration for coupling CIEF with ESI-MS using a coaxial sheath flow interface that facilitate the automation of on-line CIEF-ESI-MS analyses. The stepwise mobilization strategy is demonstrated for the analysis of standard protein mixtures and soluble E. coli lysate proteins using CIEF-ESI-MS. These results indicate that inlet pressure or voltage programming to control the elution of the protein zones from the capillary (i.e., gradient mobilization) may allow for the optimization of the mobilization conditions and provide higher resolution for CIEF separation of complex mixtures with on-line MS.  相似文献   

11.
The separations of peptide and protein mixtures in capillary zone electrophoresis (CZE) at various solution conditions were studied with the direct control of electroosmosis. The zeta potential at the aqueous/capillary interface and the resulted electroosmosis in the presence of an electric field were directly controlled by using an additional electric field applied from outside of the capillary. The controlled electroosmotic flow affected the migration time and zone resolution of peptide and protein mixtures. The changes in the magnitude and polarity of the zeta potential caused the various degrees of peptide and protein adsorption onto the capillary through the electrostatic interactions. The separation efficiencies of peptide and protein mixtures were enhanced due to the reduction in peptide and protein adsorption at the capillary wall. The direct manipulations of the separation efficiency and resolution of peptide and protein mixtures in CZE were demonstrated by simply controlling the zeta potential and the electroosmotic flow with the application of an external electric field.  相似文献   

12.
In capillary electrokinetic chromatography, neutral analytes can be injected by electroosmotic flow directly from a sample matrix into a separation buffer containing an electrokinetic vector with an opposite mobility. Analytes are injected at the velocity of electroosmotic flow but are retained at the interface of the sample matrix co-ion and separation buffer micelle zones as analyte/micelle complexes. A simple electrokinetic chromatography system containing sodium dodecyl sulfate as the micellar agent with borate as the buffering electrolyte included in the separation buffer and in the sample matrix to provide continuous conductivity was investigated. Concentrations of the micelle, methanol, and borate in the separation buffer were explored to increase maximum injection length of neutral analytes. Reducing the analyte velocity in the separation buffer without substantially decreasing the velocity of the analyte during injection from the sample vial allowed greatly extended sample plug injection lengths. It is presently possible to inject sample solvent volumes equivalent to approximately 7 effective capillary lengths (180 cm) with a 50-microm-i.d. capillary (24.5 cm effective capillary length), total volume of sample injection approximately 3.5 microL Equations describing the injection process and maximum injection lengths for this mode of stacking in electrokinetic capillary chromatography are introduced. The result of this work leads to a postulated generalization of electrokinetic stacking injection maximums for electrophoretic processes, and the concept of orthogonal analyte stacking/injection systems is discussed.  相似文献   

13.
Tang Q  Harrata AK  Lee CS 《Analytical chemistry》1996,68(15):2482-2487
On-line capillary isoelectric focusing (CIEF)-electrospray ionization mass spectrometry (ESIMS) as a two-dimensional separation system is employed for high-resolution analysis of hemoglobin variants A, C, S, and F. The effects of moving ionic boundary inside the CIEF capillary and MS scan rate on the separation resolution and mass detection of hemoglobin variants are investigated. The formation of a moving ionic boundary due to the replacement of background electrolyte counterions with sheath liquid counterions can be minimized by combining cathodic mobilization with a gravity-induced hydrodynamic flow. Hemoglobin variants F and A, with a pI difference of 0.05 pH unit, are almost baseline resolved and identified in CIEF-ESIMS. The concentration detection limit for each hemoglobin variant is in the range of 10(-)(8) M, comparable to that obtained in two-dimensional gel electrophoresis using silver staining. Initial preconcentration during the focusing step and the use of single-ion monitoring scan mode are responsible for improving detection limits.  相似文献   

14.
An on-line two-dimensional (2D) capillary electrophoresis (CE) system consisting of capillary isoelectric focusing (CIEF) and capillary gel electrophoresis (CGE) was introduced. To validate this 2D system, a dialysis interface was developed by mounting a hollow fiber on a methacrylate resin plate to hyphenate the two CE modes. The two dimensions of capillary shared a cathode fixated into a reservoir in the methacrylate plate; thus, with three electrodes and only one high-voltage source, a 2D CE framework was successfully established. A practical 2D CIEF-CGE experiment was carried out to deal with a target protein, hemoglobin (Hb). After the Hb variants with different isoelectric points (pIs) were focused in various bands in the first-dimension capillary, they were chemically mobilized one after another and fed to the second-dimension capillary for further separation in polyacrylamide gel. During this procedure, a single CIEF band was separated into several peaks due to different molecular weights. The resulting electrophoregram is quite different from that of either CIEF or CGE; therefore, more information about the studied Hb sample can be obtained.  相似文献   

15.
On-line combination of capillary isoelectric focusing (CIEF) with electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry is demonstrated for high-resolution analysis of model proteins, human hemoglobin variants, and Escherichia coli proteins. The acquisition of high-resolution mass spectra of hemoglobin beta chains allows direct identification of hemoglobin variants A and C, differing in molecular mass by 1 Da. Direct mass determination of cellular proteins separated in the CIEF capillary is achieved using their isotopic envelopes obtained from ESI-FTICR. The factors which dictate overall performance of CIEF-ESI-FTICR, including duty cycle, mass resolution, scan rate, and sensitivity, are discussed in the context of protein variants and cell lysates analyzed in this study.  相似文献   

16.
We describe the preparation and performance of high-efficiency 70 cm x 20 microm i.d. silica-based monolithic capillary LC columns. The monolithic columns at a mobile-phase pressure of 5000 psi provide flow rates of approximately 40 nL/min at a linear velocity of approximately 0.24 cm/s. The columns provide a separation peak capacity of approximately 420 in conjunction with both on-line coupling with microsolid-phase extraction and nanoelectrospray ionization-mass spectrometry. Performance was evaluated using a Shewanella oneidensis tryptic digest, and approximately 15-amol detection limits for peptides were obtained using a conventional ion trap and MS/MS for peptide identification. The sensitivity and separation efficiency enabled the identification of 2367 different peptides covering 855 distinct S. oneidensis proteins from a 2.5-microg tryptic digest sample in a single 10-h analysis. The number of identified peptides and proteins approximately doubled when the effective separation time was extended from 200 to 600 min. The number of identified peptides increased from 32 to 390 as the injection amount was increased from 0.5 to 100 ng. Both the run-to-run and column-to-column reproducibility for proteomic analyses were also evaluated.  相似文献   

17.
Cao CX  He YZ  Li M  Qian YT  Gao MF  Ge LH  Zhou SL  Yang L  Qu QS 《Analytical chemistry》2002,74(16):4167-4174
The paper presents a novel on-line transient moving chemical reaction boundary method (tMCRBM) for simply but efficiently stacking ionizable analytes in high-salt matrix in capillary zone electrophoresis (CZE). The powerful function and stability of the tMCRBM are elucidated with the ionizable test analytes of L-phenylalanine (Phe) and L-tryptophan (Trp) in the matrix with 85.6-165.6 mM sodium ion and further compared with the normal CZE of Phe and Trp samples dissolved in running buffer. The results verify that (1) the on-line tMCRBM mode can evidently increase separation efficiency, peak height, and resolution, (2) with the mode, the analytes in a 28-cm high-salt matrix plug can be stacked successfully and further separated well, (3) the values of relative standard deviation of peak height, peak area, and migrating time range from 3.9% to 6.1%; the results indicate the high stability of the technique of tMCRBM-CZE. The techniques implies obvious potential significance for those ionizable analytes, e.g., protein, peptide, and weak alkaline or acidic compound, in such matrixes as serum, urine, seawater, and wastewater, with high salt, which has a deleterious effect on isotachophoresis (ITP) and especially on electrostacking and field-amplified sample injection (FASI). The mechanism of stacking of zwitterionic analytes in a high-salt matrix by the tMCRBM relies on non-steady-state isoelectric focusing (IEF) but not on transient ITP, electrostacking, and FASI.  相似文献   

18.
An on-column mechanism for electrokinetically injecting long sample plugs with simultaneous stacking of neutral analytes in capillary electrokinetic chromatography is presented. On-column stacking methods allow for the direct injection of long sample plugs into the capillary, with narrowing of the analyte peak width to allow for an increase in the detected signal. Low-pressure injections (approximately 50 mbar) are commonly used to introduce sample plugs containing neutral analytes. We demonstrate that injection can be accomplished by applying an electric field from the sample vial directly into the capillary, with neutral analytes injected by electroosmotic flow at up to 1 order of magnitude faster than the corresponding pressure injections. Since stacking occurs simultaneously with electrokinetic injection, stacking is initiated at the capillary inlet, resulting in an increased length of capillary remaining for separation. Reproducibility obtained for peak height and peak area with electroosmotic flow injection is comparable to that obtained with the pressure injection mode, while reproducibility of analysis time is markedly improved. Electrokinetic stacking of neutral analytes utilizing electroosmotic flow is demonstrated with discontinuous (high conductivity, high mobility) as well as continuous (equal conductivity, equal mobility) sample electrolytes. Injecting neutral analytes by electroosmotic flow affords a 10-fold or greater decrease in analysis times when capillaries of 50-microm i.d. or smaller are used. This stacking method should be exportable to dynamic pH junction stacking and electrokinetic chromatography with capillary arrays. Equations describing this electrokinetic injection mode are introduced and stacking of a neutral analyte on a microchip by electrokinetic injection using a simple cross-T channel configuration is demonstrated.  相似文献   

19.
Feng YL  Zhu J 《Analytical chemistry》2006,78(18):6608-6613
A new on-line capillary zone electrophoresis/mass spectrometry (CZE/MS), constant pressure-assisted electrokinetic injection (PAEKI), for the analysis of negatively charged nucleotides is reported. PAEKI uses an applied pressure to counterbalance the reverse electroosmotic flow in the capillary column during sample injection, while taking advantage of the field amplification in the sample medium. At balance, the running buffer in the column is stationary, permitting potentially unlimited injection time, and hence unlimited sample enrichment power. The ability of PAEKI to maintain a narrow sample zone over a long injection time seems to be a result of the formation of a high ion concentration band at the boundary of the two media due to rapid deceleration of the migrating ions at the boundary. The injected amount of analytes proved to be linearly proportional to both the field amplification factor, which is expressed as the ratio of resistivities of sample medium to running buffer, and the injection time, which extended up to 1200 s in CZE/MS and 3600 s in CZE/UV. For a 300-s on-line PAEKI injection in CZE/MS, 3 orders of magnitude sample enhancement (5000-fold enrichment) could be observed for the four single nucleotides without compromising separation efficiency and peak shape, and an achievement of detection limits between 0.04 and 0.07 ng/mL. With appropriate sample cleanup, PAEKI can be used in the analysis of single nucleotides in enzyme-digested DNA.  相似文献   

20.
Proteomics analysis based-on reversed-phase liquid chromatography (RPLC) is widely practiced; however, variations providing cutting-edge RPLC performance have generally not been adopted even though their benefits are well established. Here, we describe an automated format 20 kpsi RPLC system for proteomics and metabolomics that includes on-line coupling of micro-solid phase extraction for sample loading and allows electrospray ionization emitters to be readily replaced. The system uses 50 microm i.d. x 40-200 cm fused-silica capillaries packed with 1.4-3-microm porous C18-bonded silica particles to obtain chromatographic peak capacities of 1000-1500 for complex peptide and metabolite mixtures. This separation quality provided high-confidence identifications of >12 000 different tryptic peptides from >2000 distinct Shewanella oneidensis proteins (approximately 40% of the proteins predicted for the S. oneidensis proteome) in a single 12-h ion trap tandem mass spectrometry (MS/MS) analysis. The protein identification reproducibility approached 90% between replicate experiments. The average protein MS/MS identification rate exceeded 10 proteins/min, and 1207 proteins were identified in 120 min through assignment of 5944 different peptides. The proteomic analysis dynamic range of the 20 kpsi RPLC-ion trap MS/MS was approximately 10(6) based on analyses of a human blood plasma sample, for which 835 distinct proteins were identified with high confidence in a single 12-h run. A single run of the 20 kpsi RPLC-accurate mass MS detected >5000 different compounds from a metabolomics sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号