燃煤电站锅炉实际运行排烟温度一般在130~150 ℃,进一步回收烟气余热有利于降低发电煤耗,减少污染物排放。针对电站锅炉尾部不同位置烟气参数不同的情况,设计了安装在空气预热器后及湿法脱硫装置后的两级热交换器余热回收系统,并结合330 MW燃煤电站锅炉,分析了不同负荷下,两级热交换器的换热量、冷凝水量、两侧介质静压差及发电标准煤耗降低值的变化情况,同时监测了二级热交换器前后烟气中固体颗粒物含量。结果表明:一级热交换器的换热量明显高于二级热交换器,烟气中水分主要在二级热交换器冷凝;标准煤耗降低值高达3.09 g/(kW·h);同时烟气经过二级热交换器后固体颗粒物含量明显降低。为燃煤电站锅炉尾部烟气余热回收利用提供了参考。 相似文献
2.
A mathematical model of heat-and mass transfer processes in surface-type heat exchangers that use mixtures of steam with various
noncondensable gases as heat carriers is presented. The results of numerical calculations are compared with experimental data
reported in the literature. It is shown that the thermal-physical properties of the noncondensable component in a steam-gas
mixture have an essential effect on the distribution of concentrations and temperatures over the heat exchanger length and
on the heat flux transferred in it. 相似文献
3.
换热器传热特性是影响热电联合系统优化调度的关键因素之一。针对热电联合系统,基于传热原理,采用抽汽的三级传热模型来描述换热器的传热过程,利用迭代法计算一定热负荷下的抽汽量,提出计及换热器传热特性的热电、火电、风电的联合调度模型。最后以最小化煤耗量为优化目标,分析换热器传热特性对抽汽传热过程和热电联合系统调度结果的影响。算例表明:增大换热器传热面积、降低换热器出口水温可以不同程度地提高风电消纳能力,降低运行成本,研究结果为电热联合系统优化调度方案提供换热参数选择的依据。 相似文献
4.
5.
热管烟气换热器在湿法脱硫工艺中的应用及比较 总被引:3,自引:0,他引:3
石灰石-石膏湿法烟气脱硫系统中有几种换热器,热管烟气换热器具有传热效率高、流体阻力损失小、烟 气不泄漏、脱硫率高、没有附加动力消耗、运行及维护费用低等优点,该换热器更适合石灰石-石膏湿法烟气脱硫系 统。热管烟气换热器设计、制造时,应注意热管烟气换热器低于酸露点温度区的酸腐蚀;合理控制热管壁温;选择合适 的烟气流速;合理布置管排;采用合适的清灰方式和注意换热器中孔板的密封。 相似文献
6.
7.
烟气脱硫系统回转再生式烟气换热器清洗装置使用效果探讨 总被引:2,自引:0,他引:2
介绍烟气脱硫(FGD)系统中回转再生式烟气换热器(GGH)的用途、原理及应达到的要求。针对GGH在运行中经常出现的堵灰问题,分析不同类型GGH的清洗方式及其效果,并介绍3个电厂GGH清洗装置的使用情况。根据已有的运行经验,提出了防止GGH积灰和提高清洗效果的建议。 相似文献
8.
循环流化床锅炉低温烟气余热回收工艺参数研究 总被引:1,自引:1,他引:0
循环流化床(Circulating Fluidized Bed,CFB)锅炉内石灰石脱硫技术的应用为低温烟气余热的深度回收创造了条件。以东方电厂490 t/h CFB锅炉为研究对象,提出了采用两级烟气冷却器深度回收低温烟气余热的工艺,分析了锅炉低温烟气特性,研究了烟气含湿量、酸露点和排烟温度等参数的关联特性。计算表明,低温烟气余热深度回收工艺排烟温度为40℃。研究结果可为CFB锅炉低温烟气余热深度回收工艺优化提供数据支持。 相似文献
9.
燃煤机组锅炉尾部烟气直接排放会造成大量的余热与水分损失。本文基于陶瓷膜管的选择透过性,利用溴化锂溶液的吸湿性,提出一种膜法半开式吸收式热泵系统,其中多通道陶瓷膜管吸收器吸收烟气中余热与水分,高温发生器、回热发生器及气液分离器实现溴化锂溶液的再生。以某330 MW燃煤机组锅炉为例,分析了不同循环工质参数、不同回热蒸汽流量以及吸收器内热交换量变化对膜法半开式吸收式热泵系统的影响。结果表明:溴化锂溶液的流量与溶液出口温度、脱水量呈正相关变化;吸收器内凝结水吸热量增大会提高脱水量,但会降低溶液出口温度;回热蒸汽流量变化会改变系统内各部分热量分布,增大回热蒸汽流量可以减少驱动热源热量,提高系统热回收性能,但存在限值。 相似文献
10.
11.
滴形管凝结换热性能的实验研究 总被引:3,自引:1,他引:2
李慧君 《中国电机工程学报》2009,29(20):79-84
采用特殊的管子形状和表面是最为常用、有效的强化换热手段。该文以滴形管凝结换热作为研究对象,阐述了烟气中水蒸气凝结换热过程的特点及强化换热的条件。对液滴在圆管和滴管不同位置处的受力进行分析,说明不同管形对液膜层厚度的影响程度。通过回收天然气锅炉排烟余热实验,研究滴形管的凝结换热性能,分析影响换热性能的因素,并与圆形管进行比较。结果表明:烟气通过滴形换热管的压损小于圆管,温差大于圆管,冷却水温升高于圆管,换热系数高于圆管。采用滴形管对于强化凝结换热是一种行之有效的方法。 相似文献
12.
换热器传热特性是影响热电联合系统优化调度的关键因素之一。针对热电联合系统,基于传热原理,采用抽汽的三级传热模型来描述换热器的传热过程,利用迭代法计算一定热负荷下的抽汽量,提出计及换热器传热特性的热电、火电、风电的联合调度模型。最后以最小化煤耗量为优化目标,分析换热器传热特性对抽汽传热过程和热电联合系统调度结果的影响。算例表明:增大换热器传热面积、降低换热器出口水温可以不同程度地提高风电消纳能力,降低运行成本,研究结果为电热联合系统优化调度方案提供换热参数选择的依据。 相似文献
13.
14.
Heating calculation of the surface condensate heat recovery unit (HRU) installed behind the BKZ-420-140 NGM boiler resulting in determination of HRU heat output according to fire gas value parameters at the heat recovery unit inlet and its outlet, heated water quantity, combustion efficiency per boiler as a result of installation of HRU, and steam condensate discharge from combustion products at its cooling below condensing point and HRU heat exchange area has been performed. Inspection results of Samara CHP BKZ-420-140 NGM power boilers and field tests of the surface condensate heat recovery unit (HRU) made on the bimetal calorifier base КСк-4-11 (KSk-4-11) installed behind station no. 2 Ulyanovsk CHP-3 DE-10-14 GM boiler were the basis of calculation. Integration of the surface condensation heat recovery unit behind a steam boiler rendered it possible to increase combustion efficiency and simultaneously decrease nitrogen oxide content in exit gases. Influence of the blowing air moisture content, the excess-air coefficient in exit gases, and exit gases temperature at the HRU outlet on steam condensate amount discharge from combustion products at its cooling below condensing point has been analyzed. The steam condensate from HRU gases is offered as heat system make-up water after degasification. The cost-effectiveness analysis of HRU installation behind the Samara CHP BKZ-420-140 NGM steam boiler with consideration of heat energy and chemically purified water economy has been performed. Calculation data for boilers with different heat output has been generalized. 相似文献
15.
发电机组低负荷下,锅炉省煤器出口烟温往往达不到SCR脱硝装置运行要求.为解决这一问题,对现有省煤器旁路式解决方法进行分析,找出不足,进而提出了省煤器烟气旁路式和限流式加低温换热器的解决方案.在机组低负荷运行时利用这2种新方法,能够在不影响锅炉效率的前提下,实现脱硝装置稳定、高效运行;对于排烟温度较高的锅炉,采用省煤器限流式加低温换热器的方法,能够有效降低锅炉排烟温度,提高锅炉效率. 相似文献
16.
Heat-transfer processes in a countercurrent cyclone heat exchanger are investigated on a pilot installation. Volumetric coefficients of heat transfer from gases to a flow of solid particles are determined during operation with tangentially swirled flow of gas suspension, separation of solid particles on the heat-exchanger walls, and deceleration of flue gas flows as they collide with the charge mixture fed to the apparatus. 相似文献
17.
针对国电电力甘肃酒泉发电厂1号炉脱硫系统烟气换热器换热元件严重损坏的问题,从波纹板箱结构、搪瓷喷涂工艺、蒸汽吹灰压力、烟气换热器的设计等方面进行分析,提出了相应的解决办法。分析结果表明:故障的主要原因是换热元件波纹板箱压紧力不够和搪瓷喷涂工艺存在问题。 相似文献
18.
19.
20.
该文针对目前湿法烟气脱硫技术中关键设备———再生式烟气热交换器存在的一些问题 ,提出了一种以水为换热介质的新型烟气热交换器 ,并以 40 0t/h锅炉烟气为例 ,给出了初步的设计思想和设计结果。图 2表 2参 5 相似文献