1.
This paper reports on the results of a neutron trial performance test sponsored by the European Commission and organised by EURADOS. As anticipated, neutron dosimetry results were very dependent on the dosemeter type and the dose calculation algorithm. Fast neutron fields were generally well measured, but particular problems were noted in the determination of intermediate energy fields and large incident angles, demonstrating the difficulties of neutron personal dosimetry. Of particular concern from a radiological protection point of view was the large number of results underestimating personal dose equivalent. A considerable over-response was noted in a few cases.  相似文献   

2.
3.
During 2000 a trial performance test for individual monitoring services in Europe was organised by the European Radiation Dosimetry Group (EURADOS), covering whole-body beta/photon, whole-body neutron and extremity beta/photon dosimetry for both monoenergetic and simulated workplace fields. The UK National Radiological Protection Board (NRPB), which supplies routine dosemeters to some 50,000 wearers in the UK and overseas, participated in this trial performance test. This paper presents the results obtained for the NRPB whole-body TLD, neutron (PADC) and extremity dosimetry services and comments on their performance in comparison with the overall results.  相似文献   

4.
EURADOS (European Radiation Dosimetry Group) has implemented a database of facilities and equipment for dosimetry research in the European Union. The database can be accessed freely by interested scientists via a user-friendly World Wide Web interface. Interested operators and owners of facilities can make information available to the dosimetric community by using a standardised format for information collection. The submitted data is completely in the hands of the information provider.  相似文献   

5.
Translated from Izmeritel'naya Tekhnika, No. 10, pp. 48–49, October, 1990.  相似文献   

6.
In August 2009, almost 1000 passive extremity dosemeters were irradiated at the Dosimetry Laboratory Seibersdorf as part of the EURADOS intercomparison IC2009. Forty-four European individual monitoring services participated, with a total of 59 dosimetry systems (46 finger ring, 4 finger tip and 9 wrist/ankle dosemeter systems). Additionally, finger-ring dosemeters from the Dosimetry Service Seibersdorf were irradiated in a non-competitive manner. Dosemeter irradiations on rod and pillar phantoms in four photon-radiation fields complying with the ISO standard 4037 were performed with personal dose equivalent values (H(p)(0.07)) ranging from 4 to 480 mSv. Traceability was established by using an air-kerma-calibrated monitor ionisation chamber together with the X-ray facility as well as a calibrated (137)Cs gamma radiation field with a collimated beam geometry. The ISO-tabulated conversion coefficients from air kerma free-in-air to H(p)(0.07) were applied, resulting in the main contribution to the expanded measurement uncertainties.  相似文献   

7.
8.
This paper reports the results of an investigation carried out to determine the suitability of using a commercially available photodiode for dosimetry in mammography thereby providing a low cost dosemeter with a direct reading of the radiation dose. A mammographic X-ray generator (Siemens Mammomat 1000) with tube potential in the 23-30 kV range and a constant potential X-ray generator (Pantak) with a W/Mo anode/filter combination were used in this study. The results showed that the photodiode response is highly linear within mammographic dose ranges and that the energy dependence was <3% at tube potentials of 25-30 kV. Good agreement was observed between the incident air kerma measured with both the photodiode and the ionization chamber. These results show the viability of using the photodiode as a dosemeter system in mammography.  相似文献   

9.
This trial was undertaken to assess extremity dosemeters, which were made available to Devonport Royal Dockyard and determine the most suitable to the site. The trial included operational and laboratory-based exposures. Operational exposures were within a submarine reactor compartment and a waste storage area. Laboratory exposures were undertaken using (241)Am, (137)Cs and (60)Co sources to compare and contrast the dosemeters energy response. In addition, the low dose response and the response if placed in the incorrect orientation were also assessed. Ten passive and two active dosemeters were tested, with three highlighted as the most technically suitable, DSTL Harshaw DXT-RAD, HPA Harshaw EXT-RAD and the AMEC Panasonic UD-807A. The most technically suitable dosemeter was the DSTL Harshaw DXT-RAD, due to good responses within all aspects of the trial and the user's preference for the ring type design. The John Caunt ED2 electronic dosemeter 2 (ED2) also performed well, but suffered radio frequency interference.  相似文献   

10.
Different approaches for the measurement of a relatively small gamma dose in strong fields of thermal and epithermal neutrons as used for Boron Neutron Capture Therapy (BNCT) have been studied with various thermoluminescence detectors (TLDs). CaF(2):Tm detectors are insensitive to thermal neutrons but not tissue-equivalent. A disadvantage of applying tissue-equivalent (7)LiF detectors is a strong neutron signal resulting from the unavoidable presence of (6)Li traces. To overcome this problem it is usual to apply pairs of LiF detectors with different (6)Li content. The experimental determination of the thermal neutron response ratio of such a pair at the Geesthacht Neutron Facility (GeNF) operated by PTB enables measurement of the photon dose. In the experimental mixed field of thermal neutrons and photons of the TRIGA reactor at Mainz the photon dose measured with different types of (7)LiF/(nat)LiF TLD pairs agree within a standard uncertainty of 6% whereas the CaF(2):Tm detectors exhibit a photon dose by more than a factor of 2 higher. It is proposed to determine suitable photon energy correction factors for CaF(2):Tm detectors with the help of the (7)LiF/(nat)LiF TLD pairs in the radiation field of interest.  相似文献   

11.
A sensitometric study of Kodak XV and EDR-2 radiographic films (Eastman Kodak Company, Rochester, NY) was performed using photons ranging from 75 kV to 18 MV and electrons ranging from 6 to 20 MeV. To investigate the applicability of the EDR-2 film for clinical radiation dosimetry, percentage depth-doses, profiles and distributions in open and dynamically wedged fields were measured using film and compared with data from a linear diode. Moreover, conventional quality assurance dose parameters were measured, including open-field dose profiles to determine flatness and symmetry of photon and electron beams. Finally, film was employed to validate dose distributions produced by complex computerised treatment planning techniques. Our conclusion is that the EDR-2 film is an effective tool for relative dosimetry of photon and electron beams.  相似文献   

12.
Within EURADOS working group 2, a system for self-sustained intercomparisons for individual monitoring services for external radiation was developed. With the intercomparison results, the participants can show compliance within their quality management system, compare their results with those from other participants and develop plans for improvement of their system. The costs of the exercises are covered by the participants fees. In this programme, the first intercomparison exercise for whole-body dosemeters has been executed in 2008 with 62 participating dosimetry systems from participants across Europe. In general, film systems show the largest deviations, although the results of some participants indicate that it is possible to achieve results with a film system with similar quality as for thermoluminescence dosimetry (TLD) systems. A second intercomparison has been organised for extremity dosemeters in 2009. For 2010 it is planned to organise a second intercomparison for whole-body dosemeters.  相似文献   

13.
The direct ion storage (DIS) dosemeter is a new type of electronic dosemeter from which the dose information for both Hp(10) and Hp(0.07) can be obtained instantly at the workplace by using an electronic reader unit. The number of readouts is unlimited and the stored information is not affected by the readout procedure. The accumulated dose can also be electronically reset by authorised personnel. The DIS dosemeter represents a potential alternative for replacing the existing film and thermoluminescence dosemeters (TLDs) used in occupational monitoring due to its ease of use and low operating costs. The standard version for normal photon and beta dosimetry, as well as a developmental version for neutron dosimetry, have been characterised in several field studies. Two new small size variations are also introduced, including a contactless readout device and a militarised version optimised for field use.  相似文献   

14.
The ENEA fast neutron dosemeter is based on a planar PADC (poly allyl diglycol carbonate) placed in a polyethylene holder. The CR-39 (registered trademark of PPG Industries Inc.) material, produced by Intercast Europe S.p.A., has been used in the routine of the Individual Monitoring Service (IMS) since 1998. Since then, acceptance tests on average sheet background track density and sheet neutron sensitivity have been made on new batches as a quality control within a quality assurance programme of the IMS of ENEA-Institute for Radiation Protection (IRP). Dosemeters were irradiated with a 241Am-Be source at ENEA-IRP and processed through a chemical etching procedure (pre-etching with 40% KOH water solution 6.25 N and 60% ethyl alcohol at 70 degrees C followed by 12 h of etching in 6.25 N KOH water solution). In this paper we present the analysis of acceptance testing data for more than 30 sheets of CR-39 plastic produced in 1998, 1999 and 2000. Moreover, we compare the performance of sheets of CR-39 of standard composition with that of sheets of CR-39 with the addition of DOP (dioctylphthalate), in different concentrations, on the hasis of average background density, neutron sensitivity and background fluctuation that limit the lower detectable dose. This study demonstrates the need for acceptance tests to assure the quality of the dosimetric performance of these dosemeters, which is considerably dependent on the quality of the CR-39 plastic.  相似文献   

15.
In vivo dosimetry was implemented for treatments of head and neck cancers in the large fields. Diode and thermoluminescence dosemeter (TLD) measurements were carried out for the linear accelerators of 6 MV photon beams. ESTRO in vivo dosimetry protocols were followed in the determination of midline doses from measurements of entrance and exit doses. Of the fields monitored by diodes, the maximum absolute deviation of measured midline doses from planned target doses was 8%, with the mean value and the standard deviation of -1.0 and 2.7%. If planned target doses were calculated using radiological water equivalent thicknesses rather than patient geometric thicknesses, the maximum absolute deviation dropped to 4%, with the mean and the standard deviation of 0.7 and 1.8%. For in vivo dosimetry monitored by TLDs, the shift in mean dose remained small but the statistical precision became poor.  相似文献   

16.
An analysis of doses to tooth enamel and to organs was carried out to develop a method that can predict the organ doses and the effective dose by electron spin resonance (ESR) dosimetry using tooth samples for external photon exposure. Absorbed dose to tooth enamel and organ doses were obtained by Monte Carlo calculations using the EGS4 code in combination with a mathematical human model with a newly defined teeth part. The calculations gave quantitative relations between tooth enamel dose and organ doses for some cases of external photon exposure. It was also found that tooth enamel dose depends more significantly on energy of incident photons than the other organ dose or the effective dose. The obtained data are to be useful for the assessment of individual dose in past exposure events by the ESR dosimetry using tooth enamel.  相似文献   

17.
以车载娱乐电子模块为例阐述了自动化生产线中产品功能测试系统的开发,系统使用了当今先进的测试仪器,通过系统总线协调整个系统工作,从而测试生产线生产的产品是否合格.系统采用LabWindows开发环境,开发了友好的人机界面,通过数据库系统纪录存储数据,并开发了生产控制系统,保证生产过程中产品流动的单向性.生产实践证明,该系统运行稳定可靠,测试结果一致性好,并且可以推广到其他电子产品的生产测试中.  相似文献   

18.
Once the EC Directive 96/29 has been implemented into national regulation across Europe, the coordination of dosimetry laboratories for the monitoring of occupational exposures becomes the principal aim to achieve. Within this framework the European Radiation Dosimetry Group, EURADOS, carried out an Action on 'Harmonisation of Individual Monitoring' (2000-2004) to promote coordination in the field of individual monitoring of occupational exposures throughout Europe. With reference to internal exposures, the main aims were the completion of a catalogue of internal dosimetry services and an inventory of methods and techniques used for individual monitoring at European internal dosimetry facilities. At the end of this EURADOS Action, a report was published in Radiation Protection Dosimetry in 2004. The information collected related to various topics: the equipments used for the measurement of internal exposures, calibration and sensitivity data, the methods applied for the assessment of internal doses, Quality Control procedures, Quality Assurance Programmes in the facilities and legal requirements. The information to be presented here will give a general overview of the actual status of individual monitoring for internal exposures in Europe.  相似文献   

19.
为严格测试汽车发电机性能,并匹配生产线的快速自动化生产,在对汽车发电机工作原理与性能测试深入分析的基础上,设计了由工控机、变频器、传动电机、电子负载等组成的机电一体化汽车交流发电机性能自动测试装置,实现发电机空载性能、负载性能及调节器性能测试。设计经典PID和模糊PID控制器快速调节发电机电压、电流和转速,提高了测试的快速性和稳定性,确保产品出厂质量。该装置已成功应用于德国、日本、伊朗等汽车电器生产企业。  相似文献   

20.
In recent years, several papers dealing with eye lens dosimetry have been published as epidemiological studies are implying that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. For that reason, the necessity to monitor the eye lens may become more important than it was before. However, only few dosemeters for the appropriate quantity H(p)(3) are available. Partial-body dosemeters are usually designed to measure the quantity H(p)(0.07) calibrated on a rod phantom representing a finger while a slab phantom much better represents the head. Therefore, in this work it was investigated whether dosemeters designed for the quantity H(p)(0.07) calibrated on a rod phantom can also be worn on the head (close to the eyes) and still deliver correct results (H(p)(0.07) on a head). For that purpose, different types of partial-body dosemeters from routine use were irradiated at different photon energies on both a rod and a slab phantom. It turned out that their response values are within ±5% independent of the phantom if the quantity value for the respective phantom is used. Thus, partial-body dosemeters designed for the quantity H(p)(0.07) calibrated on a rod phantom may be worn on the head and used to monitor the eye lens dose due to photon radiation via the measurement of H(p)(0.07) on the head.  相似文献   