首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
《Exergy》2001,1(2):112-121
An exergy analysis of a solid polymer fuel cell power system for transportation applications is reported. The analysis was completed by implementing the fundamental governing second law equations derived for the system into a fuel cell performance model developed previously. The model analyzes all components of the system including the fuel cell stack and the air compression, hydrogen supply, and cooling subsystems. From the analysis, it was determined that the largest destruction of exergy within the system occurs inside the fuel cell stack. Other important sources of exergy destruction include irreversibilities within the hydrogen ejector and the air compressor, and the exergy associated with the heat rejected from the radiator. The results may aid efforts to optimize fuel cell systems.  相似文献   

2.
This study deals with the thermodynamic analysis of molten carbonate fuel cell combined with a gas turbine, based on the first- and second-law of thermodynamics. The mass, energy, entropy and exergy balance equations are written and applied to the system and its components. Some parametric studies are performed to investigate the change of system performance through energy and exergy efficiencies with the change of operating conditions. The irreversibilities occuring in different devices of the integrated system are also investigated through the exergy destruction analysis in these devices. The maximum output work of the MCFC is estimated to be 314.3 kW for an operating temperature of 650 °C. The overall energy and exergy efficiencies achieved for this system are 42.89% and 37.75%, respectively.  相似文献   

3.
建立了质子交换膜燃料电池(PEMFC)堆的热力学分析模型,研究了运行温度、气体分压和阳极流量等工作参数对燃料电池堆能量效率和火用效率的影响。结果表明:对气体加压,能提高热力学能效率和火用效率;温度升高时,系统性能无明显变化;阳极流量增加时,系统的热力学能效率和火用效率有所降低。  相似文献   

4.
In this study, a comprehensive performance analysis of a transportation system powered by a PEM fuel cell engine system is conducted thermodynamically both through energy and exergy approaches. This system includes system components such as a compressor, humidifiers, pressure regulator, cooling system and the fuel cell stack. The polarization curves are studied in the modeling and compared with the actual data taken from the literature works before proceeding to the performance modeling. The system performance is investigated through parametric studies on energy, exergy and work output values by changing operating temperature, operating pressure, membrane thickness, anode stoichiometry, cathode stoichiometry, humidity, reference temperature and reference pressure. The results show that the exergy efficiency increases with increase of temperature from 323 to 353 K by about 8%, pressure from 2.5 to 4 atm by about 5%, humidity from 97% to 80% by about 10%, and reference state temperature from 253 to 323 K by about 3%, respectively. In addition, the exergy efficiency increases with decrease of membrane thickness from 0.02 to 0.005 mm by about 9%, anode stoichiometry from 3 to 1.1 by about 1%, and cathode stoichiometry from 3 to 1.1 by about 35% respectively.  相似文献   

5.
A tubular solid oxide fuel cell (TSOFC) module fed by methane is modelled and analyzed thermodynamically from the exergy point of view in this paper. The model of TSOFC module consists of mixer, pre-reformer, internal reforming fuel cell group, afterburner and internal pre-heater components. The model of the components forming module is given based on mass, energy and exergy balance equations. The developed thermodynamic model is simulated, and the obtained performance characteristics are compared and validated with the experimental data taken from the literature concerning TSOFC module. For exergetic performance analysis, the effects of operating variables such as current density, pressure, and fuel utilization factor on exergetic performances (module exergy efficiency, module exergetic performance coefficient, module exergy output and total exergy destruction rate, and components' exergy efficiencies, exergy destruction rates) are investigated. From the analysis, it is determined that the biggest exergy loss stems from exhaust gasses. Other important sources of exergy destruction involve fuel cell group and afterburner. Consequently, the developed thermodynamic model is expected to provide not only a convenient tool to determine the module exergetic performances and component irreversibility but also an appropriate basis to design complex hybrid power generation plants.  相似文献   

6.
以燃料重整的固体氧化物燃料电池发电系统为研究对象,通过数值模拟方法对固体氧化物燃料电池发电系统的性能、(火用)损、(火用)效率以及多变量运行参数优化进行了分析。研究结果表明:重整反应中燃料利用系数、电池工作温度、水碳比、电堆电流密度等参数对系统性能影响显著;电堆工作在不同电流密度下都有其对应的最佳工作温度、最佳燃料利用系数工况点;水碳比会改变重整反应产氢量,从而影响电化学反应速率,空气加热器的(火用)损所占份额最大;优化后的系统效率及(火用)效率为0.480 9和0.462 6,效率提升约4%。  相似文献   

7.
This paper examines an integrated gasification and solid oxide fuel cell (SOFC) system with a gas turbine and steam cycle that uses heat recovery of the gas turbine exhaust. Energy and exergy analyses are performed with two different types of coal. For the two different cases, the energy efficiency of the overall system is 38.1% and 36.7%, while the exergy efficiency is 27% and 23.2%, respectively. The effects of changing the reference temperature on the exergy destruction and exergy efficiency of different components are also reported. A parametric study on the effects of changing the pressure ratio on the component performance is presented.  相似文献   

8.
In this paper, a fuel cell power generation system fed by hydrogen is analyzed by different performance criteria over the entire range of potential operating conditions. First law efficiency and net power output are considered for conventional energetic indices of performance, and exergy destruction rate is taken into consideration as an exergetic performance criteria. A new exergetic criterion called the exergetic performance coefficient (EPC) is introduced and is applied to the system model based on zero-dimensional approach. The system model consists of the following components: fuel cell stack, afterburner, fuel and air compressors, and heat exchangers. The effects of the operating conditions on the system performance are studied parametrically. The obtained results based on the exergetic performance coefficient criterion are compared with first law efficiency, power output and exergy destruction rate. Results show that design insights of fuel cell systems can be considerably improved when conventional energetic analyses are supplemented with EPC criterion.  相似文献   

9.
The proton exchange membrane (PEM) fuel cell (PEMFC) is equipped with a series of auxiliary components which consume considerable amount of energy. It is necessary to investigate the design and operation of the PEMFC power system for better system performance. In this study, a typical PEMFC power system is developed, and a thermodynamic model of the system is established. Simulation is carried out, and the power distribution of each auxiliary component in the system, the net power and power efficiency of the system are obtained. This power system uses cooling water for preheating inlet gases, and its energy-saving effect is also verified by the simulation. On this basis, the exergy analysis is applied on the system, and the indexes of the system exergy loss, exergy efficiency and ecological function are proposed to evaluate the system performance. The results show that fuel cell stack and heat exchanger are the two components that cause the most exergy loss. Furthermore, the system performance under various stack inlet temperatures and current densities is also analyzed. It is found that the net power, energy efficiency and exergy efficiency of the system reach the maximum when the stack inlet temperature is about 348.15 K. The ecological function is maintained at a high level when the stack inlet temperature is around 338.15 K. Lower current density increases the system ecological function and the power and exergy efficiencies, and also helps decrease the system exergy loss, but it decreases the system net power.  相似文献   

10.
In the present study, the first and second law of thermodynamics have been used to analyze in detail the performance of a double absorption (lift) heat transformer operating with the water–lithium bromide mixture. A mathematical model was developed to estimate the coefficient of performance (COP), the exergy coefficient of performance (ECOP), the total exergy destruction in the system (ΨTD) and the exergy destruction (ΨD) in each one of the main components, as a function of the system temperatures, the efficiency of the economizer (EFEC), the gross temperature lift and flow ratio (FR). The results showed that the generator is the component with the highest irreversibilities or exergy destruction contributing to about 40% of the total exergy destruction in the whole system, reason why this component should be carefully designed and optimized. The results also showed that the COP and ECOP increase with increase in the generator, the evaporator and the absorber–evaporator temperatures and decrease with the absorber and condenser temperatures. Finally, it was observed that the COP and ECOP are very dependent of the FR and the economizer efficiency (EFEC) values. Also the optimum operating region of the analyzed system is shown in the present study. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
In this study, we deal with the exergoeconomic analysis of a proton exchange membrane (PEM) fuel cell power system for transportation applications. The PEM fuel cell performance model, that is the polarization curve, is previously developed by one of the authors by using the some derived and developed equations in literature. The exergoeconomic analysis includes the PEM fuel cell stack and system components as compressor, humidifiers, pressure regulator and the cooling system. A parametric study is also conducted to investigate the system performance and cost behaviour of the components, depending on the operating temperature, operating pressure, membrane thickness, anode stoichiometry and cathode stoichiometry. For the system performance, energy and exergy efficiencies and power output are investigated in detail. It is found that with an increase of temperature and pressure and a decrease of membrane thickness the system efficiency increases which leads to a decrease in the overall production cost. The minimization of the production costs is very crucial in commercialization of the fuel cells in transportation sector.  相似文献   

12.
The present work is employed in two sections. Firstly the effect of different parameters such as pressure, temperature and anode and cathode channel depth on the performance of the proton exchange membrane (PEM) fuel cell was experimentally studied. The experimental result shows a good accuracy compared to other works.Secondly a semi-empirical model of the PEM fuel cell has been developed. This model was used to study the effect of different operating conditions such as temperature, pressure and air stoichiometry on the exergy efficiencies and irreversibilities of the cell.The results show that the predicted polarization curves are in good agreement with the experimental data and a high performance was observed at the channel depth of 1.5 mm for the anode and 1 mm for the cathode. Furthermore the results show that increase in the operating temperature and pressure can enhance the cell performance, exergy efficiencies and reduce irreversibilities of the cell.  相似文献   

13.
Proton-exchange membrane fuel cell (PEMFC) and liquid hydrogen are gaining attention as a power generation system and alternative fuel of ship. This study proposes a novel PEMFC system, integrated with the organic Rankine cycle–direct expansion cycle (ORC-DEC), which exploits cold exergy from liquid hydrogen and low temperature waste heat generated by the PEMFC for application in a liquid hydrogen fueled ship. A thermodynamic model of each subsystem was established and analyzed from the economic, energy, and exergy viewpoints. Moreover, parametric analysis was performed to identify the effects of certain key parameters, such as the working fluid in the ORC, pressure exerted by the fuel pump, cooling water temperature of the PEMFC, and the stack current density on the system performance. The results showed that the proposed system could generate 221 kW of additional power. The overall system achieved an exergy and energy efficiency of 43.52 and 40.45%, respectively. The PEMFC system had the largest exergy destruction, followed by the cryogenic heat exchanger. Propane showed the best performance among the several investigated ORC working fluids and the system performance improved with the increase in the cooling water temperature of the PEMFC. The economic analysis showed that the average payback time of ORC-DEC was 11.2 years and the average net present value (NPV) was $295,268 at liquid hydrogen costing $3 to $7, showing the potential viability of the system.  相似文献   

14.
An exergy analysis was performed considering the combustion of methane and agro-industrial residues produced in Portugal (forest residues and vines pruning). Regarding that the irreversibilities of a thermodynamic process are path dependent, the combustion process was considering as resulting from different hypothetical paths each one characterized by four main sub-processes: reactant mixing, fuel oxidation, internal thermal energy exchange (heat transfer), and product mixing. The exergetic efficiency was computed using a zero dimensional model developed by using a Visual Basic home code. It was concluded that the exergy losses were mainly due to the internal thermal energy exchange sub-process. The exergy losses from this sub-process are higher when the reactants are preheated up to the ignition temperature without previous fuel oxidation. On the other hand, the global exergy destruction can be minored increasing the pressure, the reactants temperature and the oxygen content on the oxidant stream. This methodology allows the identification of the phenomena and processes that have larger exergy losses, the understanding of why these losses occur and how the exergy changes with the parameters associated to each system which is crucial to implement the syngas combustion from biomass products as a competitive technology.  相似文献   

15.
This paper analyzes an integrated HyS cycle (hybrid sulfur cycle), isobutane cycle and electrolyzer for hydrogen production. The operating parameters such as concentration, pressure and temperature are varied to investigate their effects on the energy and exergy efficiencies of the system with/without heat recovery and integration, as well as the decomposer and rate of hydrogen produced. A new heat exchanger network is also developed to recover heat within the HyS cycle in the most efficient manner. The exergy destruction rate in each component is analyzed and discussed. From the results, increasing the pressure is beneficial up to 3222 kPa, after which the performance remains constant. The exergy efficiency varies more significantly with operating parameters than the energy efficiency. The maximum exergy destruction occurs in the heat exchanger so this component should be the focus to enhance the overall performance of the system.  相似文献   

16.
Based on the recent improvements in high-temperature fuel cells, distributed power generation fuel cell system of small scale (~hundreds kilowatts) has been widely investigated. To improve the system efficiency, most developments focused on the fuel cell stack, but little was paid attention to the intrinsic exergy destructions at the other parts of a typical configuration. The main objective of this study is to investigate a feasibility of reducing the exergy destruction in the reforming process of fuel cell system, by using a homogeneous charge compression ignition (HCCI) engine as a replacement of existing reforming subsystems, i.e. steam methane reforming (SMR), partial oxidation (POX), or autothermal reforming (ATR), in a solid oxide fuel cell (SOFC) system. To do this, parametric studies with exergy analysis were conducted by using in-house 1-D SOFC and 0-D HCCI simulation models. In results, due to the work production from HCCI reforming engine in addition to the work of the fuel stack, it is demonstrated that HCCI-SOFC system has higher system efficiency than partial oxidation (POX) and autothermal reforming (ATR) systems, which use similar partial oxidation reaction for reformer operation. Furthermore, because of no requirement for catalyst, the HCCI system demonstrates wider operating range than that of POX and ATR systems. When compared to the steam methane reforming (SMR)-SOFC system, the HCCI-SOFC system has the lower total work but slightly higher exergetic system efficiency, mainly caused by large amount of heat exergy needed to operate endothermic reforming process in the SMR process. Based on our simulation data, the exergetic efficiency of the HCCI-SOFC system shows 6.0%, 2.1% and 0.4% higher than POX, ATR and SMR systems at the highest efficiency points of each strategy, while 5.5%, 5.8% and 3.8% higher than POX, ATR and SMR systems at 99% methane conversion points in each reformer, respectively.  相似文献   

17.
In this study, the energy and exergy analysis of Al-Hussein power plant in Jordan is presented. The primary objectives of this paper are to analyze the system components separately and to identify and quantify the sites having largest energy and exergy losses. In addition, the effect of varying the reference environment state on this analysis will also be presented. The performance of the plant was estimated by a component-wise modeling and a detailed break-up of energy and exergy losses for the considered plant has been presented. Energy losses mainly occurred in the condenser where 134 MW is lost to the environment while only 13 MW was lost from the boiler system. The percentage ratio of the exergy destruction to the total exergy destruction was found to be maximum in the boiler system (77%) followed by the turbine (13%), and then the forced draft fan condenser (9%). In addition, the calculated thermal efficiency based on the lower heating value of fuel was 26% while the exergy efficiency of the power cycle was 25%. For a moderate change in the reference environment state temperature, no drastic change was noticed in the performance of major components and the main conclusion remained the same; the boiler is the major source of irreversibilities in the power plant. Chemical reaction is the most significant source of exergy destruction in a boiler system which can be reduced by preheating the combustion air and reducing the air–fuel ratio.  相似文献   

18.
In this paper, energy and exergy analyses for a 1.2 kWp Nexa PEM fuel cell unit in a solar-based hydrogen production system is undertaken to investigate the performance of the system for different operating conditions using experimental setup and thermodynamic model. From the model results, it is found that there are reductions in energy and exergy efficiencies (about 14%) with increase in current density. These are consistent with the experimental data for the same operating conditions. A parametric study on the system and its parameters is undertaken to investigate the changes in the efficiencies for variations in temperature, pressure and anode stoichiometry. The energy and exergy efficiencies increase with pressure by 23% and 15%, respectively. No noticeable changes are observed in energy and exergy efficiencies with increase in temperature. The energy and exergy efficiencies decrease with increase in anode stoichiometry by 17% and 14%, respectively. These observations are reported for the given range of current density as 0.047–0.4 A/cm2. The results and analyses show that the PEM fuel-cell system has lower exergy efficiencies than the corresponding energy efficiencies due to the irreversibilities that are not considered by energy analysis. In comparison with experimental data, the model is accurate in predicting the performance of the proposed fuel-cell system. The parametric and multivariable analyses show that the option of selecting appropriate set of conditions plays a significant role in improving performance of existing fuel-cell systems.  相似文献   

19.
In this paper, a modeling of the Solid Oxide Electrolysis Cell (SOEC), through energetic, exergetic and electrochemical modeling approaches, is conducted, and its performance, particularly through exergy efficiency, is analyzed under various operating conditions and state properties for optimum hydrogen production. In a comprehensively performed parametric study, at a single electrolysis cell scale, the effects of varying some operating conditions, such as temperature, pressure, steam molar fraction and the current density on the cell potential and hence the performance are investigated. In addition, at the electrolyzer system scale, the overall electrolyzer performance is investigated through energy and exergy efficiencies, in addition to the system's power density consumption, hydrogen production rate, heat exchange rates and exergy destruction parameters. The present results show that the overall solid oxide electrolyzer energy efficiency is 53%, while the exergy efficiency is 60%. The exergy destruction at a reduced operating temperature increases significantly. This may be overcome by the integration of this system with a source of steam production.  相似文献   

20.
This study investigates the performance of a combined industrial molten carbonate fuel cell (MCFC) system, including a turbo expander, which was recently installed by Enbridge Inc. in Toronto, Canada. It entails a comprehensive thermodynamic analysis regarding energy and exergy calculations, subject to varying operating conditions. Furthermore, a simplified and novel method is used for a cost analysis to assess the amortization of the system. The results from the base case study suggest that an overall energy efficiency as high as 60% is achievable while fuel cell stack energy and exergy efficiencies of 50.6% and 49.3%, respectively, are reached. The cost analysis indicates that the amortization of the system may take up to 15 years of operational time, depending on the price of electricity and natural gas. However, carbon offsets may make a paramount contribution to the overall savings and economic viability of future combined MCFC systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏