首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
以过渡金属氧化物CuO为主活性组分,通过复合第二活性组分Co3O4和掺入电子助剂CeO2的考察,研制出适用于催化湿式氧化处理高浓度十二烷基苯磺酸钠(SDBS)废水的复合催化剂。实验结果表明,新制备的复合催化剂有较好的催化活性。通过对反应温度、氧气分压和废水pH值等工艺条件的考察,得出催化湿式氧化处理高浓度SDBS废水适宜的工艺条件为:反应温度为280℃、氧气分压为3 MPa、pH值为8.2,在此条件下用自制的催化剂处理初始COD质量浓度为4 942.1 mg/L的SDBS废水,在120 min内,COD去除率达到88.1%,而在相同条件下未加催化剂的湿式氧化COD去除率只有30.7%。  相似文献   

2.
The effluent from the anaerobic biological treatment of coffee wet processing wastewater (CWPW) contains a non-biodegradable compound that must be treated before it is discharged into a water source. In this paper, the wet hydrogen peroxide catalytic oxidation (WHPCO) process using Al-Ce-Fe-PILC catalysts was researched as a post-treatment system for CWPW and tested in a semi-batch reactor at atmospheric pressure and 25 °C. The Al-Ce-Fe-PILC achieved a high conversion rate of total phenolic compounds (70%) and mineralization to CO(2) (50%) after 5 h reaction time. The chemical oxygen demand (COD) of coffee processing wastewater after wet hydrogen peroxide catalytic oxidation was reduced in 66%. The combination of the two treatment methods, biological (developed by Cenicafé) and catalytic oxidation with Al-Ce-Fe-PILC, achieved a 97% reduction of COD in CWPW. Therefore, the WHPCO using Al-Ce-Fe-PILC catalysts is a viable alternative for the post-treatment of coffee processing wastewater.  相似文献   

3.
Aerobic granulation seems to be an a attractive process for COD removal from industrial wastewater, characterised by a high content of soluble organic compounds. In order to evaluate the practical aspects of the process, comparative experimental tests are performed on synthetic and on industrial wastewater, originating from pharmaceutical industry. Two pilot plants are operated as sequencing batch bubble columns. Focus was put on the feasibility of the process for high COD removal and on its operational procedure. For both wastewaters, a rapid formation of aerobic granules is observed along with a high COD removal rate. Granule characteristics are quite similar with respect to the two types of wastewater. It seems that filamentous bacteria are part of the granule structure and that phosphorus precipitation can play an important role in granule formation. For both wastewaters similar removal performances for dissolved biodegradable COD are observed (> 95%). However, a relatively high concentration of suspended solids in the outlet deteriorates the performance with regard to total COD removal. Biomass detachment seems to play a non-negligible role in the current set-up. After a stable operational phase the variation of the pharmaceutical wastewater caused a destabilisation and loss of the granules, despite the control for balanced nutrient supply. The first results with real industrial wastewater demonstrate the feasibility of this innovative process. However, special attention has to be paid to the critical aspects such as granule stability as well as the economic competitiveness, which both will need further investigation and evaluation.  相似文献   

4.
采用湿式氧化技术处理在生产磺胺间二甲氧嘧啶过程中产生的高浓度有机废水。在反应温度为250℃,初始ρ(COD)为4 575 mg/L,反应时间为2 h,pH值为7~8时,采用湿式双氧水氧化和催化湿式氧化,COD去除率分别为78.3%和92.0%,表明催化湿式氧化具有较好的COD去除效果。同时考察了催化湿式氧化中反应温度、反应时间、废水pH值对COD去除率的影响。  相似文献   

5.
为了有效处理含有复杂有机污染物的高含盐氯碱废水,采用预氧化微电解工艺预处理该类废水。试验结果表明:在曝气充氧条件下,停留时间为4 h、DO质量浓度保持在1.0 mg/L左右时,COD的去除率在25%左右,多种复杂有机污染物可得到有效的降解,为后续好氧生化处理创造了良好条件。采用本文工艺平均处理成本仅为0.08元/m3。  相似文献   

6.
维生素制药废水经过初步生化处理后,出水水质无法满足要求,具有难降解、COD和氨氮浓度高的特点,针对这些特点,本文采用"强化复合曝气水解酸化→高效厌氧复合反应→流离生物接触氧化"连续工艺深度处理维生素制药废水,研究其可行性。处理规模为7.2 m3/d的中型试验结果表明:强化复合曝气水解酸化能使进水B/C值由0.33提高到0.48,提高下一步生化反应的处理效率,当进水CODCr的浓度为150~641 mg/L,氨氮浓度为6~115 mg/L时,平均去除率分别达到84.28%、93.8%,出水COD浓度小于50mg/L,氨氮浓度小于5 mg/L,出水水质能够达到《城镇污水处理厂污染物排放标准》GB18918-2002中的一级A指标,该连续工艺深度处理此类废水具有可行性和稳定性。  相似文献   

7.
The aerated bioreactor is a promising technology for wastewater treatment. Activated carbon fiber (ACF) used as a biomembrane carrier in wastewater disposal has attracted much more concern recently. The high modulus polyacrylonitrile (PAN)-based ACF was successfully used as a biomembrane carrier for hard-to-biodegrade industrial organic wastewater disposal in a lab-scale aerated biomembrane reactor at room temperature. The biocompatibility test shows that the biomembrane grows quickly on the ACF filler (ACFF) surface; bacteria and microzoon can breed on the ACFF surface at high chemical oxygen demand (COD) concentration. The COD removal rate tests show that the ACFF bioreactor has high capability to remove COD.  相似文献   

8.
The paper reports the results of an investigation carried out at lab scale to assess the effectiveness of an innovative technology (SUPERBIO) for treating municipal and/or industrial wastewater. When this technology was applied for treating municipal wastewater, the results showed that even at maximum organic load (i.e. 7 kg COD m(-3) d(-1)), the COD in the treated effluent was lower than 50 mg L(-1). In addition, both ammonia and TKN removal efficiencies resulted in higher than 87% up to an organic load of 5.7 kg COD m(-3) d(-1) corresponding to a nitrogen load of 0.8 kg TKN m(-3) d(-1). Very satisfactory process performances also resulted during tannery wastewater treatment, when a chemical oxidation step (i.e. ozonation) was inserted in the treatment cycle of SUPERBIO. In such an instance, at organic and nitrogen loadings of 3 kgCOD m(-3) d(-1) and 0.20 kg N m(-3) d(-1), COD, NH4+ -N and TSS average removals were 96, 99 and 98%, respectively. Finally, during the whole experimentation, SUPERBIO was always characterised by a very low sludge production. Such a result was ascribed mainly to the characteristics of biomass that grew in the form of very dense granules (i.e. 130 gVSS L(Biomass)(-1) allowing a biomass concentration as high as 50-60 gTSS l(bed)(-1) to be achieved.  相似文献   

9.
The paper reports the results of an experimental investigation aimed at transferring to demonstrative scale an innovative technology (SBBGR-Sequencing Batch Biofilter Granular Reactor) for the treatment of municipal and industrial wastewater by financial support of the EU Life programme. When this technology was applied for treating municipal wastewater, the results showed that the system was able to remove 80-90% of COD, total suspended solids and ammonia independently of the hydraulic residence time investigated (i.e., from 12 to 4 h). In the case of tannery wastewater, chosen as representative of concentrated industrial wastewater, SBBGR technology was suitable for removing 80-90% of the COD, suspended solids and ammonia content up to organic loading values of 3.5 kg COD/m3.d. During both periods, the process was characterised by a very high sludge age value (theta(c) approximately 150 d) that led to a biomass concentration as high as 35 gTSS/L(bed) and a sludge production much lower (5-6 times lower) that than commonly reported for conventional treatment plants.  相似文献   

10.
This work presents preliminary results for distillery wastewater treatment in a MBR equipped with filters prepared from waste fly ash. The system was fabricated locally and employed submerged membranes in the 2-8 microm pore-size range. Distillery wastewater, after anaerobic digestion, was used as the feed and the bioreactor was inoculated with sludge obtained from a local distillery unit. The MBR was operated for around 250 days. The wastewater quality was monitored in terms of COD (chemical oxygen demand), colour, phenol, and MLSS (mixed liquor suspended solids) concentration. An average COD and phenol removal of 36% and 60% respectively was obtained. The maximum suspended solids retention by the ash filter was as high as 98%. The results were encouraging and further trials are currently underway to improve the performance.  相似文献   

11.
Taking account of the high specificity of the organic load of winery effluents, a new biophysical treatment using the stripping of ethanol combined with a final concentration by evaporation has been studied. Two options are proposed: full treatment and pre-treatment. The study of the composition of winery wastewater has shown the large, dominant part of ethanol in the organic load (75 to 99% of the COD). According to a linear correlation between COD and ethanol concentration, the determination of ethanol concentration can be used to estimate the organic load of winery wastewater. Full treatment by stripping and concentration at a pilot plant allows the separation of the wastewater into highly purified water (COD elimination > 99%), a concentrated alcoholic solution usable as bio-fuel and a concentrated by-product. Stripping alone represents an advantageous pre-treatment of winery wastewater. The purification rate reaches 78 to 85% and ethanol is recovered. The process facilitates discharge into a sewage system in view of treatment with domestic effluents and can also improve the efficiency of overloaded or old purification plants. The economical approach of this method demonstrates its competitiveness in comparison with biological treatments: low energy consumed, no sludge.  相似文献   

12.
The use of a membrane bioreactor (MBR) for removal of organic substances and nutrients from slaughterhouse plant wastewater was investigated. The chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) concentrations of slaughterhouse wastewater were found to be approximately 571 mg O2/L, 102.5 mg/L, and 16.25 mg PO4-P/L, respectively. A submerged type membrane was used in the bioreactor. The removal efficiencies for COD, total organic carbon (TOC), TP and TN were found to be 97, 96, 65, 44% respectively. The COD value of wastewater was decreased to 16 mg/L (COD discharge standard for slaughterhouse plant wastewaters is 160 mg/L). TOC was decreased to 9 mg/L (TOC discharge standard for slaughterhouse plant wastewaters is 20 mg/L). Ammonium, and nitrate nitrogen concentrations of treated effluent were 0.100 mg NH4-N/L, and 80.521 mg NO3-N/L, respectively. Slaughterhouse wastewater was successfully treated with the MBR process.  相似文献   

13.
The objective of this study was to characterize the mechanisms of the COD removal in the membrane bioreactor (MBR) process with powdered activated carbon (PAC) addition and to determine its optimal operation, for the removal of residual organic matters (ROM) from biologically treated swine wastewater. The MBR process with PAC showed higher removal efficiency of chemical oxygen demand (COD(Mn)) than that without PAC. When the average COD(Mn) concentration of the influent was 217 mg/L, the average COD(Mn) concentration of the permeate from the MBR with PAC was about 41.5 mg/L, indicating an approximate removal efficiency of 81%. On the other hand, the average COD(Mn) concentration of the permeate from the MBR without PAC was 172 mg/L. The PAC dosage estimated to obtain the above removal efficiency was about 0.74 g per litre of influent. Among the total residual organics removed by PAC-added MBR, 46.5% was removed by PAC adsorption, 20.8% by biodegradation, 4.4% by membrane separation, and 9.3% by enhanced microorganism activity. From these results, the MBR process with PAC was considered as a very useful treatment process for the reduction of COD(Mn) in biologically treated swine wastewater.  相似文献   

14.
The performance of aerobic submerged packed bed reactors was studied for the treatment of domestic wastewater using different kinds of packing materials with high specific areas (760-1,200 m(2)/m(3)). The tested materials were ceramic spheres, crushed tezontle, grains of high density polyethylene (HDPE), of low density polyethylene (LDPE) and of polypropylene (PP), cubes of polyurethane (PU) and polyethylene tape (SESSIL). The bioreactors were operated in continuous regime, applying organic loads in the range of 0.8-6.0 g COD.m(-2).d(-1). The obtained specific COD removal rates were very similar in all the reactors when they were operated at organic loads up to 2.0 g COD.m(-2).d(-1), after which differences in effectiveness appeared and the best results were determined in the reactors with SESSIL, LDPE and PU. Very low TSS, O&G and turbidity were obtained in all the effluents. The NH(3)-N and TN removals were dependent on the dissolved oxygen (DO) concentration and the removals at DO of 5 mg/l were 84-99% and 61-74% respectively. The best removals were determined in the reactors with PU, SESSIL and LDPE. The reactor with tezontle had also a good performance when operated with loads up to 1.0 g TN.m(-2).d(-1). The best phosphate removals (38-49%) were obtained in the reactors with PU, tezontle, ceramic sheres and SESSIL.  相似文献   

15.
One of the major challenges of anaerobic technology is its applicability for low strength wastewaters, such as sewage. The lab-scale design and performance of a novel Gradual Concentric Chambers (GCC) reactor treating low (165+/-24 mg COD/L) and medium strength (550 mg COD/L) domestic wastewaters were studied. Experimental data were collected to evaluate the influence of chemical oxygen demand (COD) concentrations in the influent and the hydraulic retention time (HRT) on the performance of the GCC reactor. Two reactors (R1 and R2), integrating anaerobic and aerobic processes, were studied at ambient (26 degrees C) and mesophilic (35 degrees C) temperature, respectively. The highest COD removal efficiency (94%) was obtained when treating medium strength wastewater at an organic loading rate (OLR) of 1.9 g COD/L.d (HRT = 4 h). The COD levels in the final effluent were around 36 mg/L. For the low strength domestic wastewater, a highest removal efficiency of 85% was observed, producing a final effluent with 22 mg COD/L. Changes in the nutrient concentration levels were followed for both reactors.  相似文献   

16.
This study focuses on the practical application of high concentration powdered activated carbon coupled membrane bio-reactor to domestic wastewater reclamation. The study was conducted in three parts, such as analysis of secondary domestic wastewater effluent, design and operation parameter evaluation and reclaimed water quality estimation for stream restoration. The organic concentration was 25.2-80.2 mgCOD(Cr)/L for the effluent of three domestic wastewater treatment plants. Around 50-75% of the COD was low molecular substances less than 1,000 which were quite biodegradable. The sawdust PAC was estimated to be proper adsorbent for the organics in the secondary effluents. Its Freundlich constant, K value was 5.847 and 1/n, 0.36. Using a system consists of single reactor with high concentration PAC (80 g/L) and submerged hollow fiber MF membrane module with nominal pore size of 0.1 microm, design and operation parameters were obtained, such as HRT of the bioreactor (2.5 hr), PAC concentration (80 g/L), the initial flux (less than 0.5 m/day) and intermittent suction cycle (12 min. suction and 3 min. idling). Organic removal by the system was high enough to produce reclaimed water for urban stream restoration The effluent organic concentration was at the level of 2 mg/L in terms of TOC (around 5 mg/L as COD(Cr)). Substances with molecular weight cut off < 1,000 were removed mostly by adsorption and biodegradation. Those above 1,000 were rejected at PAC cake layer on the membrane and gradually degraded by microorganisms during extended contact.  相似文献   

17.
The performance of an anaerobic mesophilic packed bed reactor, with a mixture of GAC and tezontle, followed by an aerobic suspended growth system was studied for the treatment of organic chemical wastewater with a high COD concentration (22-29 g/L). The testing of the anaerobic-aerobic system was conducted in an experimental set-up for almost 2.5 years. Different operational conditions were evaluated. The anaerobic reactor showed performance stability and COD removals higher than 80% were obtained with loads up to 16.6 kg x m(-3) x d(-1). The acclimation of the aerobic biomass to the substrate in the anaerobic effluent was very quick and COD removals higher than 94% were obtained even at high organic loads. The combined anaerobic-aerobic system allowed total COD removals higher than 99.5% and the accomplishment of the discharge requirements of 200 mgCOD/L when the anaerobic reactor was operated with loads of 8-11 kg x m(-3)x d(-1) and the aerobic reactor with 0.33 kg x kg(-1) x d(-1), being the total HRT of 4.4. The average TKN removal in the anaerobic-aerobic system was 97%, the average for the anaerobic reactor being 52% and that one for the aerobic system being 94%.  相似文献   

18.
Catalytic abatement of solutions of 1,000 mg/L in phenol, ortho and para nitrophenol and ortho and para cresols was acomplished by using two catalytic systems. Fenton's reagent was used at 50 degrees C by adding 10 mg/L of ferrous cation and different dosages of H2O2. The mixture was reacting isothermically in a batch way during 3 hours. Catalytic wet oxidation (CWO) was carried out by using a commercial Activated Carbon, Industrial React FE01606A, CWO runs were carried out in a fixed bed reactor (FBR) with concurrent upflow. Temperature and oxygen pressure of the reactor were set to 160 degrees C and 16 bar, respectively. While phenols are quicky oxidised by the Fenton reagent higher mineralisation was obtained in the CWO process.  相似文献   

19.
Heterogeneous catalytic ozonation (HCO) of wastewater is gaining both research and industrial interests. It is proved to be an advanced oxidation process since it involves hydroxyl radicals as oxidation species. Few studies have been carried out to test HCO in the treatment of landfill leachates. This work has been carried out to test three types of catalysts: activated carbon (AC), expanded perlite (EP) and titanium dioxide (TiO2) combined with ozone at 80 g/m3 gas concentration for the treatment of a leachate generated by Jebel Chakir landfill site near Tunis-capital of Tunisia. The work has shown a reduction in COD of about 45% and an increase in biodegradability (BOD5/COD) from 0.1 to 0.34. A catalyst concentration of 0.7 g/L was found optimal for the treatment of the leachate.  相似文献   

20.
Factors affecting nitrogen removal by nitritation/denitritation.   总被引:4,自引:0,他引:4  
Nitrogen removal from wastewater with high nitrogen concentration and low COD/N ratio via nitrite is advantageous. The specific character of the sludge liquor enables the application of such a method. The factors affecting process efficiency were studied. From the factors followed pH, NH4+/NH3 and NO2-/HNO2 concentration and distribution seem to be most important, using sequencing batch reactor technology and treating wastewater with high NH4+ concentration (above 1 g/l). The efficient oxidation of N-NH4+ to nitrite was achieved at a minimal nitrate production. Primary sludge was used as an internal source of substrate for the denitritation because of the organic substrate deficiency of the sludge liquor. The denitritation can be controlled by dosing of the primary sludge and can be complete. There are two operational alternatives of sludge liquor pretreatment: without pH control--lower operational costs and N-removal up to 65% and with pH control--higher operational costs and N-removal close to complete.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号