首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We present a simple and versatile scheme for characterising amplitude and phase modulation by an active element, such as a deformable mirror, in the pupil plane of a high NA microscope. By placing a mirror in the vicinity of the focal plane of the objective and recording images of the reflected focal spot on a camera, we show that reliable measurements of the influence function of the mirror actuators in the pupil plane of the objective can be obtained using an iterative electric field retrieval algorithm. Compared to direct wavefront sensors, the proposed method allows characterisation for a variety of objectives with different NA and pupil sizes without modification of the setup, requires minimal space inside the microscope, and can be used with pulsed sources such as used for multiphoton microscopy. In order to validate our method, we compare our data to the results obtained with a Shack-Hartmann wavefront sensor, and show that comparable precision is achieved.  相似文献   

2.
3.
Confocal or multiphoton microscopes, which deliver optical sections and three‐dimensional (3D) images of thick specimens, are widely used in biology. These techniques, however, are sensitive to aberrations that may originate from the refractive index structure of the specimen itself. The aberrations cause reduced signal intensity and the 3D resolution of the instrument is compromised. It has been suggested to correct for aberrations in confocal microscopes using adaptive optics. In order to define the design specifications for such adaptive optics systems, one has to know the amount of aberrations present for typical applications such as with biological samples. We have built a phase stepping interferometer microscope that directly measures the aberration of the wavefront. The modal content of the wavefront is extracted by employing Zernike mode decomposition. Results for typical biological specimens are presented. It was found for all samples investigated that higher order Zernike modes give only a small contribution to the overall aberration. Therefore, these higher order modes can be neglected in future adaptive optics sensing and correction schemes implemented into confocal or multiphoton microscopes, leading to more efficient designs.  相似文献   

4.
自适应光学系统中非共轭问题对波前校正的影响   总被引:2,自引:2,他引:0  
在常规的自适应光学系统中,变形镜与波前传感器满足共轭位置关系以保证最好的校正效果。现基于角谱理论,通过对光场线性传输过程的仿真,分析了波前传感器偏离与变形镜共轭的位置的情况下波前校正效果所受到的影响。结果表明,波前传感器偏离共轭位置的距离增大和共轭位置波前的增大,均会导致校正效果变差。  相似文献   

5.
Live imaging in cell biology requires three‐dimensional data acquisition with the best resolution and signal‐to‐noise ratio possible. Depth aberrations are a major source of image degradation in three‐dimensional microscopy, causing a significant loss of resolution and intensity deep into the sample. These aberrations occur because of the mismatch between the sample refractive index and the immersion medium index. We have built a wide‐field fluorescence microscope that incorporates a large‐throw deformable mirror to simultaneously focus and correct for depth aberration in three‐dimensional imaging. Imaging fluorescent beads in water and glycerol with an oil immersion lens we demonstrate a corrected point spread function and a 2‐fold improvement in signal intensity. We apply this new microscope to imaging biological samples, and show sharper images and improved deconvolution.  相似文献   

6.
Lateral resolution that exceeds the classical diffraction limit by a factor of two is achieved by using spatially structured illumination in a wide-field fluorescence microscope. The sample is illuminated with a series of excitation light patterns, which cause normally inaccessible high-resolution information to be encoded into the observed image. The recorded images are linearly processed to extract the new information and produce a reconstruction with twice the normal resolution. Unlike confocal microscopy, the resolution improvement is achieved with no need to discard any of the emission light. The method produces images of strikingly increased clarity compared to both conventional and confocal microscopes.  相似文献   

7.
We describe a new design for an aberration-corrected low energy electron microscope (LEEM) and photo electron emission microscope (PEEM), equipped with an in-line electron energy filter. The chromatic and spherical aberrations of the objective lens are corrected with an electrostatic electron mirror that provides independent control over the chromatic and spherical aberration coefficients Cc and C3, as well as the mirror focal length, to match and correct the aberrations of the objective lens. For LEEM (PEEM) the theoretical resolution is calculated to be ∼1.5 nm (∼4 nm). Unlike previous designs, this instrument makes use of two magnetic prism arrays to guide the electron beam from the sample to the electron mirror, removing chromatic dispersion in front of the mirror by symmetry. The aberration correction optics was retrofitted to an uncorrected instrument with a base resolution of 4.1 nm in LEEM. Initial results in LEEM show an improvement in resolution to ∼2 nm.  相似文献   

8.
A method for evaluating the performance of microscope objectives on two types of confocal scanning optical microscope is presented. Of these two confocal microscope types, off-axis beam-scanning systems are found to require microscope objectives which have been corrected for flatness of field as well as for spherical aberration and astigmatism in order to obtain maximum axial and laterial resolution. In the case of on-axis specimen-scanning microscopes, less highly corrected objective lenses (not corrected for flatness of field) may in practice prove to have superior resolving properties.  相似文献   

9.
Automated imaging of extended tissue volumes using confocal microscopy   总被引:1,自引:0,他引:1  
Confocal microscopy enables constitutive elements of cells and tissues to be viewed at high resolution and reconstructed in three dimensions, but is constrained by the limited extent of the volumes that can be imaged. We have developed an automated technique that enables serial confocal images to be acquired over large tissue areas and volumes. The computer-controlled system, which integrates a confocal microscope and an ultramill using a high-precision translation stage, inherently preserves specimen registration, and the user control interface enables flexible specification of imaging protocols over a wide range of scales and resolutions. With this system it is possible to reconstruct specified morphological features in three dimensions and locate them accurately throughout a tissue sample. We have successfully imaged various samples at 1-mum voxel resolution on volumes up to 4 mm3 and on areas up to 75 mm2. Used in conjunction with appropriate embedding media and immuno-histochemical probes, the techniques described in this paper make it possible to routinely map the distributions of key intracellular structures over much larger tissue domains than has been easily achievable in the past.  相似文献   

10.
Traditional confocal microscopy uses a physical aperture barrier to prevent out-of-focus light from reaching the detector. The physical nature of a conventional aperture limits control over the system confocality. We describe a new line scanning confocal microscope that eliminates a need for a physical aperture by employing a software-controllable rolling shutter on a CMOS camera. A confocal image is obtained by synchronizing motion of the rolling shutter and the laser line scanning over a sample. Confocal resolution of this microscope is adjustable in real time and independently established for each fluorescence channel by changing the rolling shutter width. This technology has been implemented in the IN Cell Analyzer 6000 system by GE Healthcare.  相似文献   

11.
Based on the principle of laser-feedback interferometry (LFI), a laser-feedback microscope (LFM) has been constructed capable of providing an axial (z) resolution of a target surface topography of ~ 1 nm and a lateral (x, y) resolution of ~ 200 nm when used with a high-numerical-aperture oil-immersion microscope objective. LFI is a form of interferometry in which a laser's intensity is modulated by light re-entering the illuminating laser. Interfering with the light circulating in the laser resonant cavity, this back-reflected light gives information about an object's position and reflectivity. Using a 1-mW He–Ne (λ = 632·8 nm) laser, this microscope (PHOEBE) is capable of obtaining 256 × 256-pixel images over fields from (10 μm × 10 μm) to (120 μm × 120 μm) in ~ 30 s. An electromechanical feedback circuit holds the optical pathlength between the laser output mirror and a point on the scanned object constant; this allows two types of images (surface topography and surface reflectivity) to be obtained simultaneously. For biological cells, imaging can be accomplished using back-reflected light originating from small refractive-index changes (> 0·02) at cell membrane/water interfaces; alternatively, the optical pathlength through the cell interior can be measured point-by-point by growing or placing a cell suspension on a higher-reflecting substrate (glass or a silicon wafer). Advantages of the laser-feedback microscope in comparison to other confocal optical microscopes include: the simplicity of the single-axis interferometric design; the confocal property of the laser-feedback microscope (a virtual pinhole), which is achieved by the requirement that only light that re-enters the laser meeting the stringent frequency, spatial (TEM00), and coherence requirements of the laser cavity resonator mode modulate the laser intensity; and the improved axial resolution, which is based on interferometric measurement of optical amplitude and phase rather than by use of a pinhole as in other types of confocal microscopes.  相似文献   

12.
We have built a fibre optic confocal reflectance microscope capable of imaging biological tissue in near real time. The measured lateral resolution is 3 µm and axial resolution is 6 µm. Images of epithelial cells, excised tissue biopsies, and the human lip in vivo have been obtained at 15 frames s?1. Both cell morphology and tissue architecture can be appreciated from images obtained with this microscope. This device has the potential to enable reflected light confocal imaging of internal organs for in situ detection of pathology.  相似文献   

13.
Spatial resolution and the sensitivity to detect a fluorophore are the two most important optical parameters that characterize a confocal microscope. However, these are rather difficult to estimate quantitatively. We show that fluorescence correlation spectroscopy (FCS) provides an easy and reliable measure of these quantities. We modify existing schemes for performing FCS on a commercial confocal microscope to carry out these measurements, and provide an analysis routine that can yield the relevant quantities. Our method does not require any modification of the confocal microscope, yet it yields a robust measure of the resolution and sensitivity of the instrument.  相似文献   

14.
We compare the axial sectioning capability of multifocal confocal and multifocal multiphoton microscopy in theory and in experiment, with particular emphasis on the background arising from the cross‐talk between adjacent imaging channels. We demonstrate that a time‐multiplexed non‐linear excitation microscope exhibits significantly less background and therefore a superior axial resolution as compared to a multifocal single‐photon confocal system. The background becomes irrelevant for thin (< 15 µm) and sparse fluorescent samples, in which case the confocal parallelized system exhibits similar or slightly better sectioning behaviour due to its shorter excitation wavelength. Theoretical and experimental axial responses of practically implemented microscopes are given.  相似文献   

15.
A tandem scanning confocal microscope (TSCM) is currently being used to obtain high-resolution images of the human cornea in vivo. Advantages of confocal microscopy for in vivo imaging include optical sectioning and increased contrast through removal of scattered light. We have adapted the TSCM to view the retina in vivo by constructing an applanating lens and fitting the microscope with an imaging-intensifying camera of increased sensitivity. The microscope uses a spinning disc with 40,000 holes, each of 30 microns diameter, and a 100 W mercury arc lamp light source with a 455 nm long pass filter. The applanating lens is composed of three elements, two of which are movable for focusing. Images of a rabbit retina were obtained in vivo revealing the nerve fiber layer and blood vessels around the optic disc. The power density at the retina was calculated to be 3 mW/cm2, which is well below the power levels of a direct or indirect ophthalmoscope. Magnification of the retinal image was approximately 60x and a 1 mm wide area of retina was in view. This prototype TSCM system demonstrates that images of a retina in vivo are obtainable with confocal microscopy and that the sharpness is comparable to standard fundus camera photography. Further modifications to improve the light level and alterations in the design of the objective should improve the quality of the images obtained and achieve the enhanced resolution of which, in theory, the confocal microscope is capable.  相似文献   

16.
A straightforward and transparent model, based on Gaussian beam optics, for the axial r 0 resolution of a confocal microscope is presented. A confocal Raman microscope was used to determine the axial confocality in practice. The axial response of a thin planar object was measured for three different objectives, two pinhole sizes and a slit. The results show that, in the case of a confocal configuration, the response calculated with the model provides a good prediction of the axial resolution of the confocal microscope.  相似文献   

17.
In this paper we show how a tightly focused pump beam can be used to alter the local refractive index of the sample. This local variation acts as a scattering site, which enables resolution exceeding that of a conventional scanning microscope to be obtained in the far field. The improvement in resolution depends on a number of factors which are discussed in the paper, including the optical configuration (confocal or non-confocal), the thermal properties of the sample, the 'strength' of the object and the duration of the heating pulse. Experimental results confirming the theoretical predictions are presented; these demonstrate more than 25% improvement in edge response compared with a conventional scanning system.  相似文献   

18.
Three-dimensional (3-D) image analysis algorithms and experimental results that demonstrate the feasibility of fully automated tracing of neurons from fluorescence confocal microscopy data are presented. The input to the automated analysis is a set of successive optical slices that have been acquired using a confocal scanning laser microscope. The output of the system is a labelled graph representation of the neuronal topology that is spatially aligned with the 3-D image data. A variety of topological and metric analyses can be carried out using this representation. For instance, precise measurements of volumes, lengths, diameters and tortuosities can be made over specific portions of the neuron that are specified in terms of the graph representation. The effectiveness of the method is demonstrated for a set of sample fields featuring selectively stained neurons. Additional work will be needed to refine the method for unsupervised use with complex data involving multiple intertwined neurons and extremely fine dendritic structures.  相似文献   

19.
The bilateral scanning approach to confocal microscopy is characterized by the direct generation of the image on a two-dimensional (2-D) detector. This detector can be a photographic plate, a CCD detector or the human eye, the human eye permitting direct visualization of the confocal image. Unlike Nipkow-type systems, laser light sources can be used for excitation. A design called a carousel has been developed, in which the bilateral confocal scan capability can be added to an existing microscope so that rapid exchange and comparison between confocal and non-confocal imaging conditions is possible. The design permits independent adjustment of confocal sectioning properties with lateral resolutions better than, or, in the worst case equivalent to, those available in conventional microscopy. The carousel can be considered as a stationary optical path in which certain imaging conditions, such as confocality, are defined and operate on part of the imaging field. The action of the bilateral scan mirror then extends this image condition over the whole field. A number of optical arrangements for the carousel are presented which realize various forms of confocal fluorescence and reflection imaging, with point, multiple point or slit confocal detection arrangements. Through the addition of active elements to the carousel direct stereoscopic, ratio, time-resolved and other types of imaging can be achieved, with direct image formation on a CCD, eye or other 2-D detectors without the need to modify the host microscope. Depending on the photon flux available, these imaging modes can run in real-time or can use a cooled CCD at (very) low light level for image integration over an extended period.  相似文献   

20.
To examine many of the imaging capabilities of confocal scanning laser microscopes rapidly and reliably over the whole field of view three simple, easily prepared specimens are required: a mirror positioned on a carefully measured shallow gradient, a film of highly fluorescent material and a rectangular grid with a readily defined centre. Using these specimens the adjustment of any combination of confocal scanning laser visualization system and light microscope can be examined throughout the field of view. The effects of misalignment of the various subcomponents of a confocal scanning laser microscope on both the axial spread function of a plane and the shading pattern over the image field are described. Finally, where the design of the confocal optics permits, the three specimens can be used to facilitate the alignment of the various components to the optimal level achievable.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号