 共查询到20条相似文献,搜索用时 109 毫秒
1.
The responses of TLD-1010, TLD-700 and TLD-600 thermoluminescence dosemeters to the radiation field inside a water tank enclosing an isotopic 241Am-Be neutron source are analysed. Separate contributions coming from thermal neutrons, neutrons with energies above thermal and gamma rays to the total response of the three types of TLD are obtained. This is accomplished by assuming that the gamma responses for materials with different 6Li enrichments are identical and that the neutron response of TLD-700 is negligible compared to TLD-100 and TLD-600. The last assumption is tested by Monte Carlo simulations of the neutron energy spectrum at the points where the TLDs are irradiated.  相似文献   

2.
Biological data is necessary for estimation of protection from neutrons, but there is a lack of data on biological effects of neutrons for radiation protection. Radiological study on fast neutrons has been done at the National Institute of Radiological Sciences. An intense neutron source has been produced by 25 MeV deuterons on a thick beryllium target. The neutron energy spectrum, which is essential for neutron energy deposition calculation, was measured from thermal to maximum energy range by using an organic liquid scintillator and multi-sphere moderated 3He proportional counters. The spectrum of the gamma rays accompanying the neutron beam was measured simultaneously with the neutron spectrum using the organic liquid scintillator. The transmission by the shield of the spurious neutrons originating from the target was measured to be less than 1% by using the organic liquid scintillator placed behind the collimator. The measured neutron energy spectrum is useful in dose calculations for radiobiology studies.  相似文献   

3.
K. Jahn  M. Jckel  K. Brunner 《低温学》1983,23(12):667-669
Measurements of the thermal conductivity and of the dielectric properties of an epoxy-resin irradiated by fast and thermal neutrons are presented. The discussion of the experimental results accounts for the radiation dose and energy of neutrons.  相似文献   

4.
The response functions of 25.4 cm (length) x 25.4 cm (diameter) NE213 organic liquid scintillator have been measured for neutrons in the energy range from 20 to 800 MeV at the Heavy-Ion Medical Accelerator in Chiba (HIMAC) and at the Research Center for Nuclear Physics (RCNP) of Osaka University. At HIMAC, white (continuous) energy spectrum neutrons were produced by the 400 MeV per nucleon carbon ion bombardment on a thick graphite target, whose energy spectrum has already been measured by Kurosawa et al., [Nucl. Sci. Eng. 132, 30 (1999)] and the response functions of the time-of-flight-gated monoenergetic neutrons in a wide energy range from 20 to 800 MeV were simultaneously measured. At RCNP, the quasi-monoenergetic neutrons were produced via 7Li(p,n)7Be reaction by 250 MeV proton beam bombardment on a thin 7Li target, and the TOF-gated 245 MeV peak neutrons were measured. The absolute peak neutron yield was obtained by the measurement of 478 keV gamma rays from the 7Be nuclei produced in a Li target. The measured results show that the response functions for monoenergetic neutrons < 250 MeV have a recoil proton plateau and an edge around the maximum light output, which increases with increasing incident neutron energy, on the other hand > 250 MeV, the plateau and the edge become unclear because the proton range becomes longer than the detector size and the escaping protons increase. It can be found that the efficiency of the 24.5 cm (diameter) x 25.4 cm (length) NE213 for the 250 MeV neutrons is -10 times larger than the 12.7 cm (length) x 12.7 cm (diameter) NE213, which is widely used as a neutron spectrometer.  相似文献   

5.
The structure of the survival curve of melanoma cells irradiated by 14 MeV neutrons displays unusual features at very low dose rate where a marked increase in cell killings at 0.05 Gy is followed by a plateau for survival from 0.1 to 0.32 Gy. In parallel a simulation code was constructed for the interaction of 14 MeV neutrons with cellular cultures. The code describes the interaction of the neutrons with the atomic nuclei of the cellular medium and of the external medium (flask culture and culture medium), and is used to compute the deposited energy into the cell volume. It was found that the large energy transfer events associated with heavy charged recoils can occur and that a large part of the energy deposition events are due to recoil protons emitted from the external medium. It is suggested that such events could partially explain the experimental results.  相似文献   

6.
Two batches of diodes, with different structural ratios (the ratio of area and thickness), were made using different manufacturing processes. The energy response of the first batch to 15 kinds of monoenergetic neutrons ranging from 180 keV to 17.56 MeV was tested, and the neutron source response of both batches to 239Pu-Be neutron source was measured. The energy deposition in the diodes irradiated by 1 keV to 20 MeV monoenergetic neutrons was calculated with simulation procedure. The response curve of the experimental results showed an approximately similar trend to that of theoretical computation. Based on the results of the neutron source response experiments, it was concluded that the response of fast neutron varied linearly with the structural ratio of the detectors.  相似文献   

7.
For the purposes of radiological protection, it is important to analyse profiles of the particle field inside a human body irradiated by high energy hadrons, since they can produce a variety of secondary particles which play an important role in the energy deposition process, and characterise their radiation qualities. Therefore Monte Carlo calculations were performed to evaluate dose distributions in terms of the linear energy transfer of ionising particles (dose-LET distribution) using a newly developed particle transport code (Particle and Heavy Ion Transport code System, PHITS) for incidences of neutrons, protons and pions with energies from 100 MeV to 200 GeV. Based on these calculations, it was found that more than 80% and 90% of the total deposition energies are attributed to ionisation by particles with LET below 10 keV microm(-1) for the irradiations of neutrons and the charged particles, respectively.  相似文献   

8.
A phoswitch-type detector has been developed for monitoring neutron doses in high-energy accelerator facilities. The detector is composed of a liquid organic scintillator (BC501A) coupled with ZnS(Ag) sheets doped with 6Li. The dose from neutrons with energies above 1 MeV is evaluated from the light output spectrum of the BC501A by applying the G-function, which relates the spectrum to the neutron dose directly. The dose from lower energy neutrons, on the other hand, is estimated from the number of scintillations emitted from the ZnS(Ag) sheets. Characteristics of the phoswitch-type detector were studied experimentally in some neutron fields. It was found from the experiments that the detector has an excellent property of pulse-shape discrimination between the scintillations of BC501A and the ZnS(Ag) sheets. The experimental results also indicate that the detector is capable of reproducing doses from thermal neutrons as well as neutrons with energies from one to several tens of megaelectronvolts (MeV).  相似文献   

9.
Measurement Techniques - Issues in enhancing the precision of the determination of the mean energy and the type of energy distribution (spectrum form) of neutrons from Sb–Be and Ra–Be...  相似文献   

10.
During radiation therapy with an ion beam, the production of secondary particles like neutrons, protons and heavier ions contribute to the dose delivered to tumour and healthy tissues outside the treated volume. Also, the secondary particles leaving the patient are of interest for radiation background around the ion-therapy facility. Calculations of secondary particle production and the dose absorbed by water, soft tissue and a multi-material phantom simulating the heterogeneous media of the patient body were performed for protons, helium, lithium and carbon ions in the energy range up to 400 MeV u(-1). The Monte Carlo code SHIELD-HIT for transport of protons and light ions in tissue-like media was used in these studies. The neutron ambient dose-equivalent, H*(10), was determined for neutrons leaving the water phantom irradiated with different light ion beams. The comparison of calculated secondary particle production in the water and PMMA phantoms irradiated with helium and carbon ions shows satisfactory agreement with experimental data.  相似文献   

11.
Energy distributions of secondary charged particles were calculated in tissue substitutes irradiated by neutrons from 0.14 to 65 MeV, using the Particle and Heavy Ion Transport code System. The calculations were compared with experimental data measured by tissue equivalent proportional counters (TEPC). It is found that the calculated distributions of the lineal energy, y, generally agree well with the measured ones for neutrons from several 100 keV to 15 MeV. In the case of 40 and 65 MeV neutron irradiations, wall effects of TEPC should be considered and the fluence of alphas is underestimated by the calculations. Integrated dose contributions of the secondary charged particles are generally in good agreement with those of the measured ones.  相似文献   

12.
Y. Hayashiuchi  T. Okada 《低温学》1984,24(3):127-132
The neutron irradiation effects on cryostability of composite superconductors for fusion reactors are studied based on Maddock's condition. In particular, to estimate the effects of 14 MeV neutrons we assumed that the irradiation-induced degradation of critical temperature, critical current density and conductivity of stabilizer are determined by the damage energy depending on the neutron energy spectrum. The cryostability is found to decrease sensitively with increasing the fraction α of fusion neutrons with energy of 10 ~ 14 MeV to the total neutrons, ie, the Cu/superconductor ratio Rns, to stabilize the conductor, must be increased remarkably with increasing α as well as the total dose of the neutron fluence. For the small Rns (~4) the stabilized overall current density decreases by several ten percents even at the fluence when Tc and Jc change by only a few percent. This effect is dominated by the severe increase of ρ.  相似文献   

13.
A monolithic silicon telescope, consisting of a DeltaE and an E stage-detector ( approximately 1.9 microm and 500 microm thick, respectively), was coupled to a polyethylene converter in order to investigate the feasibility of a solid state microdosimeter with respect to the field-funnelling effect. This work discusses the preliminary results of an analytical approach for the correction of a spectrum measured with this silicon-based microdosimeter for tissue-equivalence and geometrical effects. The device was irradiated with 2.7 MeV monoenergetic neutrons at the INFN-Laboratori Nazionali di Legnaro (Legnaro, Italy). The non tissue-equivalence of silicon was corrected by exploiting the signals generated in the E-stage. The correction for the sensitive volume geometry was optimised by taking into account the track length distribution of the recoil-protons generated in the converter. The derived dose distribution of the energy imparted per event was compared to the one measured with a cylindrical tissue-equivalent proportional counter (TEPC). The agreement is satisfactory.  相似文献   

14.
Several INTEGRAL n-type HPGe detectors have been irradiated by fast neutrons and their degradation studied through the analysis of line shapes. The availability of three different fast neutron beams (5, 16 and 6–70 MeV) allowed a quantitative analysis of the importance of the neutron energy on the amount of damage. A comparison is made with the degradation induced by high-energy proton irradiations. Transient effects on the measured resolution are reported after high voltage cut-off on degraded detectors.  相似文献   

15.
Values for the dose equivalent are required for radiation protection purposes, but determination of such values can be quite difficult for high energy radiations. The accurate determination of personal dose equivalents in accelerator radiation fields requires the propel use of appropriate radiological quantities and units, knowledge of the dose equivalent response of the personal dosemeters used, measurement or calculation of the fluence spectrum in the workplace and the fluence spectrum of the reference radiation used to calibrate the dosemeters, in addition to knowledge of the appropriate fluence-to-dose equivalent conversion coefficients. This information can then be used to select the appropriate dosemeters, set up the optimum calibration conditions, or to establish correction factors that account for differences in the calibration and workplace fluence spectra. High energy neutrons account for a significant fraction of the dose equivalent received by workers at accelerator facilities, and this work discusses the procedures and methods needed to determine dose equivalent produced by neutrons in the vicinity of high energy particle accclerators.  相似文献   

16.
The effect of irradiation with the reactor radiation spectrum components on the strength and antifriction characteristics of St. 45 steel and armco iron was studied. It was shown that bombardment with fast neutrons leads to an increase in the strength and wear resistance of materials, while the temporary reduction in strength due to irradiation may be associated with the influence of thermal neutrons. The strength of quenched structures is increased as a result of irradiation not only with a mixed spectrum but also with fast neutrons.  相似文献   

17.
We report measurements of the emission time distributions (pulse shapes) as functions of energy for neutrons emerging from two heavily irradiated, ambient-temperature polyethylene moderators in IPNS. A time-focused crystal spectrometer arrangement provided resolution such that instrumental broadening was insignificant; cooling the Ge monochromator to 10 K provided adequate reflectivity in the high energy region. Measurements covered the range 2.5 < E < 1000 meV.We introduce a novel set of functions which fit the pulse shapes over the entire range of energies with four wavelength-independent parameters.  相似文献   

18.
Passive detectors, as albedo or track-etch, still dominate the field of neutron personal dosimetry, mainly due to their low-cost, high-reliability and elevated throughput. However, the recent appearance in the market of electronic personal dosemeters for neutrons presents a new option for personal dosimetry. In addition to passive detectors, electronic personal dosemeters necessitate correction factors, concerning their energy and angular response dependencies. This paper reports on the results of a method to evaluate personal dosemeters for workplace where neutrons are present. The approach here uses few instruments and does not necessitate a large mathematical workload. Qualitative information on the neutron energy spectrum is acquired using a simple spectrometer (Nprobe), reference values for H*(10) are derived from measurements with ambient detectors (Studsvik, Berthold and Harwell) and angular information is measured using personal dosemeters (electronic and bubbles dosemeters) disposed in different orientations on a slab phantom.  相似文献   

19.
In radiotherapy with external beams, healthy tissues surrounding the target volumes are inevitably irradiated. In the case of neutron therapy, the estimation of dose to the organs surrounding the target volume is particularly challenging, because of the varying contributions from primary and secondary neutrons and photons of different energies. The neutron doses to tissues surrounding the target volume at the Louvain-la-Neuve (LLN) facility were investigated in this work. At LLN, primary neutrons have a broad spectrum with a mean energy of about 30 MeV. The transport of a 10×10 cm2 beam through a water phantom was simulated by means of the Monte Carlo code MCNPX. Distributions of energy-differential values of neutron fluence, kerma and kerma equivalent were estimated at different locations in a water phantom. The evolution of neutron dose and dose equivalent inside the phantom was deduced. Measurements of absorbed dose and of dose equivalent were then carried out in a water phantom using an ionization chamber and superheated drop detectors (SDDs). On the beam axis, the calculations agreed well with the ionization chamber data, but disagreed significantly from the SDD data due to the detector's under-response to neutrons above 20 MeV. Off the beam axis, the calculated absorbed doses were significantly lower than the ionization chamber readings, since gamma fields were not accounted for. The calculated data are doses from neutron-induced charge particles, and these agreed with the values measured by the photon-insensitive SDDs. When exposed to the degraded spectra off the beam axis, the SDD offered reliable estimates of the neutron dose equivalent.  相似文献   

20.