首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The objective of this study is to propose and evaluate advanced absorption cycles for the coefficient of performance (COP) improvement and temperature lift enhancement applications. The characteristics of each cycle are assessed from the viewpoints of the ideal cycle COP and its applications. The advanced cycles for the COP improvement are categorized according to their heat recovery method: condensation heat recovery, absorption heat recovery, and condensation/absorption heat recovery. In H2O–LiBr systems, the number of effects and the number of stages can be improved by adding a third or a fourth component to the solution pairs. The performance of NH3–H2O systems can be improved by internal heat recovery due to their thermal characteristics such as temperature gliding. NH3–H2O cycles can be combined with adsorption cycles and power generation cycles for waste heat utilization, performance improvement, panel heating and low temperature applications. The H2O–LiBr cycle is better from the high COP viewpoints for the evaporation temperature over 0°C while the NH3–H2O cycle is better from the viewpoint of low temperature applications. This study suggests that the cycle performance would be significantly improved by combining the advanced H2O–LiBr and NH3–H2O cycles.  相似文献   

2.
An improved system of NH3–H2O–LiBr was proposed for overcoming the drawback of NH3–H2O absorption refrigeration system. The LiBr was added to NH3–H2O system anticipating a decrease in the content of water in the NH3–H2O–LiBr system. An equilibrium cell was used to measure thermal property of the ternary NH3–H2O–LiBr mixtures. The pressure–temperature data for their vapor–liquid equilibrium (VLE) data were measured at ten temperature points between 15–85 °C, and pressures up to 2 MPa. The LiBr concentration of the solution was chosen in the range of 5–60% of mass ratio of LiBr in pure water. The VLE for the NH3–H2O–LiBr ternary solution was measured statically. The experimental results show that the equilibrium pressures reduced by 30–50%, and the amount of component of water in the gas phase reduced greatly to 2.5% at T=70 °C. The experimental results predicted much better characteristics of the new ternary system than the NH3–H2O system for the applications.  相似文献   

3.
This paper proposes a new working fluid for refrigeration cycles utilizing low temperature heat sources. The proposed working fluid consists of the ammonia–water working fluid mixture and a salt. The salt is used to aid the removal of ammonia from the liquid solution. This effect is a manifestation of the well known “salting-out” effect. While the addition of salt improves the generator performance, it also has a detrimental effect on the absorber. The overall effects on the performance of three absorption cycles using the NH3–H2O–NaOH working fluid have been investigated using computer simulations. The results indicated that salting out can lower the generator operating temperature while simultaneously improving the cycle performance. Furthermore, limiting the salt to the generator suggests potential for further improvement in cycle performance.  相似文献   

4.
The advanced energy storage technology proposed and patented by authors can be applied for cooling, heating, dehumidifying, combined cooling and heating, and so on. It is also called the variable mass energy transformation and storage (VMETS) technology in which the masses in one or two storage tanks change continuously during the energy charging and discharging processes. This paper presents an advanced energy storage system using aqueous lithium bromide (H2O–LiBr) as working fluid. As one of VMETS systems, this system is a closed system using two storage tanks. It is used to shift electrical load and store energy for cooling, heating or combined cooling and heating. It is environmental friendly because the water is used as refrigerant in the system. Its working principle and process of energy transformation and storage are totally different from those of the traditional thermal energy storage (TES) systems. The electric energy in off-peak time is mostly transformed into the chemical potential of the working fluid and stored in the system firstly. And then the potential is transformed into cold or heat energy by absorption refrigeration or heat pump mode when the consumers need the cold or heat energy. The key to the system is to regulate the chemical potential by controlling the absorbent (LiBr) mass fraction or concentration in the working fluid with respect to time. As a result, by using a solution storage tank and a water storage tank, the energy transformation and storage can be carried out at the desirable time to shift electric load efficiently. Since the concentration of the working solution in the VMETS cycle varies continuously, the working process of the VMETS system is dynamic. As the first part of our study, the working principle and flow of the VMETS system were introduced first, and then the system dynamic models were developed. To investigate the system characteristics and performances under full-storage and partial-storage strategies, the numerical simulation will be performed in the subsequent paper. The simulation results will be very helpful for guiding the actual system and device design.  相似文献   

5.
Temperature–entropy (Ts) diagrams have the unique capability of being able to quantify processes in terms of both the first and second laws of thermodynamics. Although use of generalised Ts diagrams has been made to indicate or represent generalised absorption cycles, with the exception for NH3/water systems, these diagrams have not been specifically tailored to scale to quantify LiBr/water systems. The main barrier for this is that the diagram needs to represent the necessary properties of both the refrigerant (water) and of the solution (LiBr/water). This paper describes the use of the Ts diagram of water extended with additional curves to represent real and ideal LiBr/water absorption cycles. An explanation is provided on several methods available, including details of the thermodynamic justification of the method that was used, to construct the extended diagrams. Finally, the extended Ts diagram is provided with the representation of a real single-effect LiBr/water absorption refrigeration cycle. This should prove to be a valuable tool for design and research engineers to study and optimise LiBr/water chillers.  相似文献   

6.
The objectives of this paper are to investigate the effect of heat transfer additive and surface roughness of micro-scale hatched tubes on the absorption performance and to provide a guideline for the absorber design. Two different micro-scale hatched tubes and a bare tube are tested to quantify the effect of the surface roughness on the absorption performance. The roughness of the micro-scale hatched tubes ranges 0.39–6.97 μm. The working fluid is H2O/LiBr solution with inlet concentration of 55, 58 and 61 wt.% of LiBr. Normal Octanol is used as the heat transfer additive with the concentration of 400 ppm. The absorber heat exchanger consists of 24 horizontal tubes in a column, liquid distributor at the liquid inlet and the liquid reservoir at the bottom of the absorber. The effect of heat transfer additive on the heat transfer rate is found to be more significant in the bare tube than that in the micro-scale hatched tubes. It is found that the absorption performance for the micro-hatched tube with heat transfer additive becomes up to 4.5 times higher than that for the bare tube without heat transfer additive. It is concluded that the heat transfer enhancement by the heat transfer additive is more significant than that by the micro-scale surface treatment.  相似文献   

7.
General models for the design of the heat exchangers (absorber, generator, condenser and evaporator) of a prototype of an air-cooled absorption chiller of 2 kW for air-conditioning using the pair H2O–LiBr have been developed. An absorption machine of such characteristics has been constructed to be used as a test facility for validating the results obtained from the mathematical models developed. The discrepancies considering the heat exchanged between numerical results and experimental data are under 15% in most cases for all these components except the condenser, where the discrepancies are higher. The conclusions reported will lead to: (i) future improvements of the mathematical simulation models and (ii) improvements in the experimental infrastructure.  相似文献   

8.
The thermodynamic properties (solubility, vapour pressure, density, viscosity, heat capacity and heat of mixing) of the H2O + CH3OH + LiBr + ZnCl2 (9:1 H2O:CH3OH and 1:1 LiBr:ZnCl2 by mass) system using H2O + CH3OH as the working media and LiBr + ZnCl2 as the absorbents were measured. The solubility data were obtained in the temperature range from 270.35 to 389.55 K. The measurements of vapour pressure, density, viscosity and heat capacity were carried out at various temperatures and absorbent concentrations. The differential heat of dilution and differential heat of solution at 298.15 K were measured for solutionw with absorbent concentrations from 0 to 75.2 wt%. The integral heat of mixing data at 298.15 K were obtained from both sets of experimental data. The integral heats of mixing for this quaternary system showed exothermic behaviour. The vapour pressure data were correlated with an Antoine-type equation. An empirical formula for the heat capacity was obtained from experimental data. The experimental data for the basic thermodynamic properties of this quaternary system were compared with those of the basic H2O + LiBr system.  相似文献   

9.
The concept of an air-cooled absorption chiller system is attractive because the cooling tower and the associated installation and maintenance issues can be avoided. However, crystallization of the LiBr–H2O solution then becomes the main challenge in the operation of the chiller, since the air-cooled absorber tends to operate at a higher temperature and concentration level than the water-cooled absorber due to the relative heat transfer characteristics of the coolant. This leads to crystallization of the working fluid. The paper focuses on the crystallization issues and control strategies in LiBr–H2O air-cooled absorption chillers. As a result a novel application opportunity is proposed for the integration of absorption chillers into cooling, heating and power (CHP) systems. This new methodology allows for air cooler operation while avoiding crystallization.  相似文献   

10.
The PVTx properties of H2O + NH3 mixture (0.2607 mole fraction of ammonia) have been measured in the near- and supercritical regions. Measurements were made along 40 liquid and vapor isochores in the range from 120.03 to 727.75 kg m−3 and at temperatures from 301 to 634 K and at pressures up to 28 MPa. Temperatures and densities at the liquid–gas phase transition curve, dew- and bubble-pressure points, and the critical parameters for the 0.7393 H2O + 0.2607 NH3 mixture were obtained using the quasi-static thermograms and isochoric (P–T) break-point techniques. The expanded uncertainty of the density, pressure, temperature measurements at the 95% confidence level with a coverage factor of k = 2 is estimated to be 0.06%, 0.02–0.09%, and 15 mK, respectively.  相似文献   

11.
An environmentally friendly GAX cycle for panel heating: PGAX cycle   总被引:1,自引:0,他引:1  
The objectives of this paper are to develop an environmentally friendly GAX cycle using NH3–H2O for panel heating applications (PGAX), and compare it to a single effect cycle for panel heating applications (PSE cycle). The PGAX cycle can be operated in three different modes with just one hardware — cooling, space heating and panel heating applications. The total COP of the PGAX cycle is higher than that of the PSE cycle due to the internal heat recovery in the GAX component. The UA ratio has more significant effect on the total COP of the PGAX cycle than that of the PSE cycle. The panel heating COP is more significantly affected by the absorber UA variation than the space heating COP. There should be optimum ratios of absorber UAs to provide the highest total COP for a given split ratio of the coolant mass flow rate in the PGAX cycle. The results from the parametric analysis of UA ratio can be used to obtain the best UA combination of the absorbers for given space heating and panel heating capacities. This paper provides the optimum UA values of the absorbers for a given split ratio of the coolant mass flow rate.  相似文献   

12.
13.
This paper is the second part of our study on the advanced energy storage system using H2O–LiBr as working fluid. In the first part, the system working principle has been introduced, and the system dynamic models in the operation process have also been developed. Based on the previous research, this paper focuses on the numerical simulation to investigate the system dynamic characteristics and performances when it works to provide combined air-conditioning and hot water supplying for a hotel located near by Yangzi River in China. The system operation conditions were set as follows: the outdoor temperature was between 29 °C and 38 °C, the maximum air-conditioning load was 1450 kW, the total air-conditioning capacity was 19,890 kWh and the 50 °C hot water capacity for showering was 20 tons which needed heat about 721 kWh on a given day. Under these conditions, the system operation characteristics were simulated under the full- and partial-storage strategies. The simulation results predicted the dynamic characteristics and performances of the system, including the temperature and concentration of the working fluid, the mass and energy in the storage tanks, the compressor intake mass or volume flow rate, discharge pressure, compression ratio, power and consumption work, the heat loads of heat exchanger devices in the system and so on. The results also showed that the integrated coefficient of performances (COPint) of the system were 3.09 and 3.26, respectively, under the two storage strategies while the isentropic efficiency of water vapor compressor was 0.6. The simulation results are very helpful for understanding and evaluating the system as well as for system design, operation and control, and device design or selection in detail.  相似文献   

14.
A method is presented by which the coefficients of performance of advanced absorption cycles can be calculated very quickly if the efficiencies of single-stage heat pumps and heat transformers are known. The method provides detailed results for the heat input or output of the individual exchange units. These values can be used as a basis for comparison of different cycles, for numerical cycle calculations or for estimates of investment costs. Examples are given for heat pumps, refrigerators, heat transformers and heat pump transformers. Numerical results are presented for the working fluid pairs H2O/LiBr and NH3/H2O.

Résumé

A method is presented by which the coefficients of performance of advanced absorption cycles can be calculated very quickly if the efficiencies of single-stage heat pumps and heat transformers are known. The method provides detailed results for the heat input or output of the individual exchange units. These values can be used as a basis for comparison of different cycles, for numerical cycle calculations or for estimates of investment costs. Examples are given for heat pumps, refrigerators, heat transformers and heat pump transformers. Numerical results are presented for the working fluid pairs H2O/LiBr and NH3/H2O.  相似文献   

15.
The objectives of this study are to measure the vapor absorption rate and heat transfer rate for falling film flow of binary nanofluids, and to compare the enhancement of heat transfer and mass transfer under the same conditions of nanofluids. The key parameters are the base fluid concentration of LiBr, the concentration of nanoparticles in weight %, and nanoparticle constituents. The binary nanofluids are H2O/LiBr solution with nanoparticles of Fe and Carbon nanotubes (CNT) with the concentrations of 0.0, 0.01 and 0.1 wt %. The vapor absorption rate increases with increasing the solution mass flow rate and the concentration of Fe and CNT nanoparticles. It is found that the mass transfer enhancement is much more significant than the heat transfer enhancement in the binary nanofluids with Fe and CNT. It is also found that the mass transfer enhancement from the CNT nanoparticles becomes higher than that from the Fe nanoparticles. Therefore, the CNT is a better candidate than Fe nanoparticles for absorption performance enhancement in H2O/LiBr absorption system.  相似文献   

16.
The paper proposes an original linear phenomenological theory (Ph T) of evolution physical mono-, bi- and particular polycomponent gas–liquid interactions with non-ideal mixture. The expressions of the phenomenological factors (entropy source, force, coefficient and coupled heat and mass transfer currents) are deduced. The theory is particularized to the NH3/H2O and other gas–liquid systems used in the thermal absorption technology. The work's conclusions are listed next. The paper raises the problem of ammonia bubble absorption which is difficult to answer with current theory of interface mass transfer and absorption as a surface phenomenon. The heat and mass transfer at the gas–liquid interface is governed by the thermodynamic force, which applies also to solid–liquid, solid–gas, or liquid–liquid, gas–gas type interactions and continuous or discontinuous media. The paper mentions a postulate referring to the force behavior approaching an ideal point, previously formulated by the author. According to its consequence, the mass and heat currents suffer an ideal point approaching (i.p.a.) effect, not mentioned so far in the specialized literature, consisting in a continuous increase of their absolute value by several percent (for a pure component), to several hundred times (for a binary system) when the interacting system approaches an ideal state, as compared to the values of states which are far from the same ideal point. In this way, “far from equilibrium” becomes synonymous to “low interaction”. The classic assessment of the interface mass transfer by analogy with heat transfer lacks basic physics. The (Ph T) satisfactorily explains the problem of ammonia bubble absorption. Absorption is a mass phenomenon, not a surface one. An intensive way of improving absorption is emphasized, which seeks to promote the i.p.a. effect appearance rather than the extensive way currently used, based on increasing gas–liquid interaction area. To this extent, the bubble absorber is hereby proposed for efficient absorption. The i.p.a. effect existence offers an additional chance for a satisfactory explanation of the Marangoni effect.  相似文献   

17.
The objectives of this paper are to investigate the effect of surface roughness of micro-hatching tubes on the absorption performance and to develop an experimental correlation of Nusselt number as a function of the roughness. Two different micro-scale hatched tubes and a bare tube are tested to quantify the effect of the surface roughness on the absorption performance. The roughness of the micro-scale hatched tubes ranges 0.386–11.359 μm. The working fluid is H2O/LiBr solution with inlet concentration of 55, 58 and 61 wt.% of LiBr. The absorber heat exchanger consists of 24 horizontal tubes in a column, liquid distributor at the liquid inlet and the liquid reservoir at the bottom of the absorber. It was found that absorption performance of micro-hatching tubes was improved up to two times compared with the bare tube. An experimental correlation of Nusselt number was developed as a function of the film Reynolds number and the roughness with an error band of ±25%.  相似文献   

18.
The paper describes an experimental plant aimed at simulating and verifying the performances of a single-stage H2O–LiBr absorption machine. The machine is water cooled and it is supplied by hot water produced by an electrical boiler; it is possible to simulate different service conditions by varying the temperatures and the flow rate of water in the external circuits. Measurement facilities allow to record in real time all the main operating parameters of internal and external circuits (temperatures, pressures and flow rates). The paper illustrates the characteristics of the machine and of the plant and the results of various experimental campaigns. In particular, the acquisitions on the plant have tested different service conditions by varying the flow rate and the temperature of the supplying hot water; the energy and energy performances of the plant are presented and compared with data from literature and from a simulation code developed for the plant.The results show that the absorption machine can work, with acceptable efficiency, with input temperatures of about 65–70 °C; this result is interesting for a future supply of the machine with solar energy.  相似文献   

19.
The possibility of using R124 (2-chloro-1,1,1,2,-tetrafluoroethane, CHClFCF3) and organic absorbents as working fluids in absorption heat pumps was investigated. Various classes of organic compounds, all commercially available, were tested as absorbents for possible combination with R124; the absorbents included DMAC (N′, N′-dimethylacetamide, C4H9NO), NMP (N-methyl-2-pyrrolidone, C5H9NO), MCL (N-methyl ε-caprolactam, C7H13NO), DMEU (dimethylethylene urea, C5H10N2O), and DMETEG (dimethylether tetraethyleneglycol, C10H22O5). To evaluate the performance of a candidate refrigerant-absorbent pair in a refrigeration or heat pump cycle, the thermophysical properties of the pure components and the mixture and the equilibrium and transport properties have to be determined, either from experimental data or by prediction methods. The thermal stability of the refrigerant-absorbent must also be tested. A method for the calculation of the concentration in the liquid and gas phases and the excess thermodynamic properties of the mixture as a function of the system temperature and pressure based on our experimental setup is described. On the basis of vapor-liquid equilibrium measurements, density and viscosity measurements and thermostability testing, enthalpy-concentration diagrams were constructed. The performance characteristics of the investigated working fluids in terms of the coefficient of performance (COP) and the circulation ratio (f) were calculated for a single-stage absorption cycle. In terms of overall performance (COP, f and stability) R124-DMAC was found to be the superior combination, followed by R124-NMP, R124-DMEU and R124-MCL (the three pairs for which stability problems were found at high temperatures), and finally by R124-DMETEG.  相似文献   

20.
The objectives of this paper are to develop a new method of wettability measurement, to study the effect of micro-scale surface treatment on the wettability across horizontal tubes and to apply it for numerical analysis of heat and mass transfer in a H2O/LiBr falling film absorber. Three types of tubes with roughness are tested in a test rig. Inlet solution temperature (30–50 °C), concentration (55–62 wt.% of LiBr) and mass flow rate (0.74–2.71 kg/min) are considered as key parameters. Reynolds number ranged from 30 to 120 by controlling the inlet mass flow rate. The wettability on the roughened tubes was higher than that for the smooth tubes. The wettability decreased linearly along the vertical location but was proportional to the solution temperature and mass flow rate. The experimental correlations of the wettability for the smooth and the roughened tubes were developed with error bands of ±20 and ±10%, respectively. These are used for the heat and mass transfer analysis of absorbers with micro-scale hatched tubes.  相似文献   