首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Apartments account for over 60% of total residential buildings and consume a significant portion of primary energy in South Korea. Various energy efficiency measures have been implemented for both new apartment constructions and existing apartment retrofits. Old apartment structures have poor thermal performances, resulting in a high energy consumption. The South Korean government initiated retrofitting projects to improve the energy efficiency in old apartments. Apartment owners typically replace old windows with high-performance windows; however, there is still a demand for better and more innovative retrofit methods for a highly improved energy efficiency. This paper proposes an advanced double-skin façade (DSF) system to replace existing balcony windows in old apartments. Considering the cold climate conditions of Seoul, South Korea, it mainly discusses heating energy savings. Three case models were developed: Base-Case with existing apartment, Case-1 with typical retrofitting, and Case-2 with the proposed DSF system. The EnergyPlus simulation program was used to develop simulation models for a floor radiant heating system. A typical gas boiler was selected for low-temperature radiant system modeling. The air flow network method was used to model the proposed DSF system. Five heating months, i.e., November to March, and one representative day, i.e., January 24, were selected for detailed analysis. The main heat loss areas consist of windows, walls, and infiltration. The results reveal that the apartment with the DSF retrofit saves 38.8% on the annual heating energy compared to the Base-Case and 35.2% compared to Case-1.  相似文献   

2.
This study uses bottom-up modeling framework in order to quantify potential energy savings and emission reduction impacts from the implementation of energy efficiency programs in the building sector in China. Policies considered include (1) accelerated building codes in residential and commercial buildings, (2) increased penetration of district heat metering and controls, (3) district heating efficiency improvement, (4) building energy efficiency labeling programs and (5) retrofits of existing commercial buildings.Among these programs, we found that the implementation of building codes provide by far the largest savings opportunity, leading to an overall 17% reduction in overall space heating and cooling demand relative to the baseline. Second are energy efficiency labels with 6%, followed by reductions of losses associated with district heating representing 4% reduction and finally, retrofits representing only about a 1% savings.  相似文献   

3.
Energy saving is a high-priority in developed countries. For this reason, energy-efficient measures are being increasingly implemented in all sectors. The residential sector is responsible for an important part of the energy consumption in the world. Most of this energy is used in heating, cooling, and artificial ventilation systems.With a view to developing energy-efficient structures, this article provides an overview of building design criteria that can reduce the energy demand for the heating and cooling of residential buildings. These criteria are based on the adoption of suitable parameters for building orientation, shape, envelope system, passive heating and cooling mechanisms, shading, and glazing. An analysis was made of previous studies that evaluated the influence of these parameters on the total energy demand and suggested the best design options. This study is useful for professionals who are responsible for decision-making during the design phase of energy-efficient residential buildings.  相似文献   

4.
The Yangtze River Basin in China is characterised by hot-and cold-humid climates in summer and winter, respectively. Thus, increased demand for heating and cooling energy according to the season, as well as poor indoor thermal comfort, are inevitable. To overcome this problem, this study focused on the influence of passive design and heating, ventilation, and air conditioning equipment performance on the energy performance of residential buildings, and explored potential energy-saving technology paths involving passive design and improved coefficient of performance through a multi-objective and multi-parameter optimisation technique. A large-scale questionnaire survey covering a typical city was first conducted to identify family lifestyle patterns regarding time spent at home, family type, air conditioner use habits, indoor thermal comfort, etc. Then, the actual heating and cooling energy consumption and information of model building were determined for this region. Subsequently, the design parameters of an individual building were simulated using Energyplus to investigate the cooling and heating energy consumption for a typical residential building with an air conditioner. The results indicated an improvement of approximately 30% in energy efficiency through optimisation of the external-wall insulation thickness and the external-window and shading performance, and through use of appropriate ventilation technology. Thus, a multi-objective and multi-parameter optimisation model was developed to achieve comprehensive optimisation of several design parameters. Experimental results showed that comprehensive optimisation could not only reduce cooling and heating energy consumption, but also improve the thermal comfort level achieved with a non-artificial cooling and heating source. Finally, three energy-saving technology paths were formulated to achieve a balance between indoor thermal comfort improvement and the target energy efficiency(20 kWh/(m2?a)). The findings of this study have implications for the future design of buildings in the Yangtze River Basin, and for modification of existing buildings for improved energy efficiency.  相似文献   

5.
封闭式阳台作为居住建筑延伸空间,是被动式附加阳光间的一种形式.该文通过分析封闭阳台型式、围护结构热工性能、太阳辐射强度、外遮阳等因素对阳台温差修正系数α的影响,推荐给出严寒、寒冷、夏热冬冷地区代表城市居住建筑不同型式封闭阳台适用于工程应用的温差修正系数简便计算公式,为准确评估封闭阳台这类附加阳光间对供暖房间增益效果提供...  相似文献   

6.
Measurements of the thermal behaviour of two residential buildings equipped with a green roof system have been performed in Athens, Greece. Experimental data have been used to calibrate detailed simulation tools and the specific energy and environmental performance of the planted roofs system has been estimated in detail. Simulations have been performed for free‐floating and thermostatically controlled conditions. The expected energy benefits as well as the possible improvements of the indoor thermal comfort have been assessed. It is found that green roofs have a limited contribution to the heating demand of insulated buildings operating under the Mediterranean climate. On the contrary, the green roof system is found to contribute highly to reduce the cooling load of thermostatically controlled buildings. For the considered residential buildings, a cooling load decrease of about 11% has been calculated. In parallel, it is found that green roofs contribute to improve thermal comfort in free‐floating buildings during the summer period. The expected maximum decrease of the indoor air and roof surface temperatures is close to 0.6°C. Such a decrease contributes to reduce by 0.1 the summer absolute Predicted Mean Vote Comfort Index levels in the building. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
针对咸阳市某节能住宅小区供冷供热的需求,依据建筑节能规范指标要求,进行围护结构热工设计与计算。结合当地丰富的浅层地下水资源条件,确定了利用地下水源热泵系统对该住宅小区进行供冷供热方案。对系统经济性和节能性进行计算与分析,对比分析了建筑围护结构和空调系统对建筑节能的贡献率,指出了建筑节能集成效益的优势。  相似文献   

8.
The housing sector is a major consumer of energy. Studies on the future energy demand under climate change which also take into account future changes of the building stock, renovation measures and heating systems are still lacking. We provide the first analysis of the combined effect of these four influencing factors on the future energy demand for room conditioning of residential buildings and resulting greenhouse gas (GHG) emissions in Germany until 2060. We show that the heating energy demand will decrease substantially in the future. This shift will mainly depend on the number of renovated buildings and climate change scenarios and only slightly on demographic changes. The future cooling energy demand will remain low in the future unless the amount of air conditioners strongly increases. As a strong change in the German energy mix is not expected, the future GHG emissions caused by heating will mainly depend on the energy demand for future heating.  相似文献   

9.
Heating, cooling and lighting appliances in buildings account for more than one third of the world's primary energy demand and there are great potentials, which can be obtained through better applications of the energy use in buildings. In this regard, the building sector has a high potential for improving the quality match between energy supply and demand because high temperature sources are used to meet low-temperature heating needs. Low exergy (or LowEx) systems are defined as heating or cooling systems that allow the use of low valued energy, which is delivered by sustainable energy sources (i.e., through heat pumps, solar collectors, either separate or linked to waste heat, energy storage) as the energy source. These systems practically provide heating and cooling energy at a temperature close to room temperature while the so-called LowEx approach, which has been and still being successfully used in sustainable buildings design.The present study comprehensively reviews the studies conducted on LowEx heating and cooling systems for establishing the sustainable buildings. In this context, an introductory information is given first. Next, energy utilization and demand in buildings are summarized while various exergy definitions and sustainability aspects along with dead (reference) state are described. LowEx heating and cooling systems are then introduced. After that, LowEx relations used to estimate energy and exergy demand in buildings and key parameters for performance assessment and comparison purposes are presented. Finally, LowEx studies and applications conducted are reviewed while the last section concludes. The exergy efficiency values of the LowEx heating and cooling systems for buildings are obtained to range from 0.40% to 25.3% while those for greenhouses vary between 0.11% and 11.5%. The majority of analyses and assessments of LowEx systems are based on heating of buildings.  相似文献   

10.
Sung-Hwan Cho  Kee-Shik Shin  M. Zaheer-Uddin   《Energy》1995,20(12):1225-1236
The effect of slat angle and absorptance on the heating and cooling loads of buildings in Seoul (South Korea) has been studied. An analytical model of a window system with venetian blinds is developed and validated with published experimental data. The validated model has been successfully incorporated into the TRNSYS computer program. Hour-by-hour heating/cooling loads of a typical building, with and without venetian blinds, are compared. Results show that the use of windows with venetian blinds can reduce the building heating load by about 5% and cooling loads by as much as 30%.  相似文献   

11.
This article reports investigations of a residential building in Serbian conditions energized by electricity from photovoltaics (PVs), and the electricity grid. The building uses electricity to run its space heating system, lighting and appliances, and to heat domestic hot water (DHW). The space heating system comprises floor heaters, a water-to-water heat pump, and a ground heat exchanger. The PV system generates electricity that either may be consumed by the building or may be fed-in the electricity grid. The electricity grid is used as electricity storage. Three residential buildings are investigated. The first residential building has PVs that yearly produce smaller amount of electricity than the heating system requires. This is a negative-net energy building (NNEB). The second building has the PVs that produce the exact amount of electricity that the entire building annually needs. This is a zero-net energy building (ZNEB). The third building has PVs that entirely cover the south-facing roof of the building. This is a positive-net energy building (PNEB). These buildings are presented by a mathematical model, partially in an EnergyPlus environment. For all buildings, simulations by using EnergyPlus software would give the generated, consumed, and purchased energy with time step, and monthly and yearly values. For sure, these buildings would decrease demand for electricity during summer, however they will increase this demand during winter when there is no sun and start of space heating is required. Depending on the size of PV array this building will be either NNEB, or ZNEB, or PNEB. However it is crucial for such a building to be connected to the electricity grid. The smaller payback for investment in the PV array is obtained for buildings with larger size of PV array. The feed-in tariff for the generation of electricity in Serbia should be under the constant watch to be corrected accordingly for larger penetration of this technology in the Serbian market.  相似文献   

12.
The residential sector plays an important role in the energy system of developing countries. In this paper we introduce a bottom up simulation model for household energy use. The model describes energy demand for several end-use functions based on a set of physical drivers, such as floor space and heating degree days. The model also recognizes different population groups: i.e. urban and rural households, each distinguishing five income quintiles. The model is applied to analyze possible future developments of residential energy use in five developing world regions: India, China, South East Asia, South Africa and Brazil. We find that in each of these regions cooking is currently the main end-use function, but that other functions, such as space heating, cooling and appliances become more important. At the same time, energy consumption slowly shifts towards modern fuels. The model also shows that climate policy can reduce residential energy emissions, but could also slow down the energy transition away from traditional fuels in low income classes.  相似文献   

13.
According to one survey on energy consumption in Iran, commercial and building sector consume more energy than any other economic sectors. For example, about 38% of total energy that consumed in year 2001 has been used for space heating. Insulation in external walls of buildings has an important role to reduce the environmental effects on indoor space condition. Therefore, always using insulation is an alternative to avoid from the energy loss. In this paper, the effects of the using of a proper insulation on the energy saving in Iranian buildings are studied. For this purpose, an integrative modelling is used for simulation of the energy consumption in buildings. It is shown that energy consumption per square meter of buildings can be reduced up to 35.2% when insulation is used for external walls.  相似文献   

14.
To analyze the effect of energy conservation policies on energy consumption of residential buildings, the characteristics of energy consumption and indoor thermal comfort were investigated in detail in Tianjin, China, based on official statistical yearbook and field survey data. A comprehensive survey of 305 households indicates that the mean electricity consumption per household is 3215 kWh/a, in which annual cooling electricity consumption is 344 kWh/a, and the mean natural gas consumption for cooking is 103.2 m3/a. Analysis of 3966 households data shows that space heating average intensity of residential buildings designed before 1996 is 133.7 kWh/(m2·a), that of buildings designed between 1996 and 2004 is 117.2 kWh/(m2·a), and that of buildings designed after 2004 is 105.0 kWh/(m2·a). Apparently, enhancing the performance of envelops is effective in reducing space heating intensity. Furthermore, the results of questionnaires show that 18% of the residents feel slightly warm and hot respectively, while 3% feel slightly cold in winter. Therefore, the electricity consumption in summer will rise for meeting indoor thermal comfort.  相似文献   

15.
Abstract

A simplified and accurate hybrid model is proposed to analyze, evaluate, and predict space heating energy consumption and indoor temperature in residential buildings connected to district heating systems. With classical engineering equations of thermodynamic laws, this method uses physical and empirical modeling to describe heat exchangers in real-time. Furthermore, the model has optimized the cost of computation and enhanced the prediction accuracy. It is revealed this method can accurately predict the residential heat load and indoor temperature with the maximum error of ±10%. The architectural parameter, outdoor temperature, and wind velocity have decisive effects on the heat energy demand.  相似文献   

16.
It is generally accepted that climate changes will have a major effect on our lives. However, buildings will also be faced with climate changes, and these changes will have an impact on indoor comfort, energy demands and the efficiency of building services, especially on those supporting free cooling and free heating. In order to predict the expected changes in a building's thermal response during its lifetime, it is necessary to look at the climate changes predicted for the future. In our study, the climate changes were considered by using simplified mathematical models combined with available test reference years to establish ‘corrected test reference years’. A transient simulation tool, TRNSYS, was used to simulate the indoor climate and the useful energy demand for the heating and cooling of different buildings with different free‐cooling techniques. In order to predict the expected changes in a building's thermal response, the meteorological parameters for the moderate, continental climate region of Slovenia were taken into account. The study shows that during a building's lifetime, significant changes in useful energy demands can be expected—a decrease in the useful energy demand for heating of between 23 and 40% and an up‐to‐38‐times increase in the useful energy needed for mechanical cooling. In buildings without mechanical cooling, the efficiency of the different free‐cooling techniques should be increased by between 100 and 200% to ensure the same living comfort. The results presented in the study confirm that it is necessary to evaluate the consequences of global climate changes from the point of view of energy use in buildings, their construction and the buildings' service installations. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

17.
In the context of rapid urbanization and new construction in rural China, residential building energy consumption has the potential to increase with the expected increase in demand. A process-based hybrid life-cycle assessment model is used to quantify the life-cycle energy use for both urban and rural residential buildings in China and determine the energy use characteristics of each life cycle phase. An input–output model for the pre-use phases is based on 2007 Chinese economic benchmark data. A process-based life-cycle assessment model for estimating the operation and demolition phases uses historical energy-intensity data. Results show that operation energy in both urban and rural residential buildings is dominant and varies from 75% to 86% of life cycle energy respectively. Gaps in living standards as well as differences in building structure and materials result in a life-cycle energy intensity of urban residential buildings that is 20% higher than that of rural residential buildings. The life-cycle energy of urban residential buildings is most sensitive to the reduction of operational energy intensity excluding heating energy which depends on both the occupants' energy-saving behavior as well as the performance of the building itself.  相似文献   

18.
建筑形式对太阳能热利用的影响研究   总被引:1,自引:0,他引:1  
简毅文 《太阳能学报》2007,28(1):108-112
以上海地区的住宅建筑为研究对象,通过模拟分析的方法,采用DeST软件计算确定建筑逐时的采暖、空调能耗,研究分析窗墙比对建筑全年采暖能耗、全年空调能耗以及全年采暖、空调总能耗的影响规律,研究分析太阳辐射热增加所导致采暖能耗的降低幅度与外围护结构保温性能两者之间的定量关系。计算结果表示在夏季外窗遮阳和夜间通风的条件下,加大南向窗墙比可增强太阳能的热利用效率,降低建筑全年的采暖、空调总能耗;而外围护结构保温性能的增强则可降低室内向室外散热的程度,相应提高对冬季太阳辐射的热利用程度,从而达到降低采暖能耗的目的。  相似文献   

19.
The need for simple yet accurate techniques for assessing the thermal performances of buildings is discussed, particularly in relation to residential buildings in Australia. A method is presented for calculating heating or cooling load requirements in terms of indoor temperatures in totally unconditioned (i.e. free-running) buildings. The method accounts for thermal capacitance in the building fabric and intermittent heating or cooling. It can also allow for climatic variability from day to day. The method is a generalization of the variable base degree-day technique which has recently achieved prominence in the United States of America.  相似文献   

20.
王君  王矗垚  季杰 《新能源进展》2021,9(4):300-310
针对新徽派民居中存在的建筑能耗大、热舒适性差及室内空气品质低等问题,探索在保持建筑典型特点的前提下,将太阳能光伏光热建筑一体化(BIPV/T)新技术和新方法在新徽派民居中综合运用。文章主要基于作者团队最新的研究,探讨了兼顾“黛瓦”的光伏瓦技术、兼顾“粉壁”的集热-除甲醛多效墙体技术、兼顾“马头墙”的通风-除菌杀毒多效太阳能烟囱技术、兼顾“青砖”的光伏装饰技术、兼顾“门楼”的平板型PV/T技术、兼顾“花格窗”的碲化镉光伏通风窗技术在新徽派民居中应用的可行性。通过一典型案例设计,基于Energyplus软件对其全年发电量、热水、室温、房间冷热负荷及通风性能进行模拟研究。结果表明,BIPV/T技术可以在发电的同时降低空调负荷、改善室内环境,节能效果显著。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号