Recently, studies suggest that the average indoor temperature is typically >30°C and that the maximum temperature can reach 37.5°C in hot-humid areas. However, the effects caused by increasing the humidity at high indoor temperatures are not clear. In this study, twelve female and twelve male subjects were exposed to different operative temperature (26.6, 30.6, and 37.4°C) and relative humidity (50% and 70%) in a climate chamber. Data concerning thermal sensation, perceived air quality, and Sick Building Syndrome (SBS) were collected during 190-min-long exposure to each thermal condition. Heart rate, respiration rate, respiratory ventilation rate, mean skin temperature, and eardrum temperature were measured. It was found that increasing the relative humidity from 50% to 70% at 26 and 30°C had no significant effects on the physiological responses, thermal comfort, perceived air quality, or SBS symptoms of the subjects. However, when the temperature was elevated to 37°C, the heart rate, respiration rate, respiratory ventilation rate, mean skin temperature, and eardrum temperature increased significantly as a result of the increase in the relative humidity from 50% to 70%. The subjects felt hotter and more uncomfortable, and they found indoor air quality was more difficult to accept. The subjects are acclimatized to hot environments and more tolerant to heat. Therefore, the results are applicable to the acclimated people living in hot-humid climate.  相似文献   

2.
This study assessed the effects of clothing and air temperature combinations on workplace productivity and physiological response. Ten male Japanese subjects were exposed to six combinations of clothing (0.3 clo and 0.9 clo) and air temperature (16°C, 26°C, and 36°C) during which cognitive performance (Bourdon and calculation tests), manual motor performance (finger-tapping test), and physiological responses (heart rate, blood pressure, and skin and oral temperatures) were measured. Both cold exposure and lower clothing levels likely increased the Bourdon test performance. Calculation test performance tended to be affected by exposure to cold or neutral temperatures at the beginning of the test. Cold exposure undermined manual motor performance (especially when combined with fewer clothing items) while heat exposure significantly increased heart rate. Both cold exposure and higher clothing level during heat exposure increased blood pressure. Body temperature, particularly mean skin temperature, increased with higher air temperature and was significantly influenced by clothing insulation during cold exposure. These results provide novel evidence for the effects of clothing and air temperature (particularly cold) on human productivity and physiological responses in humans.  相似文献   

3.
This study investigated whether adjusting clothing to remain in neutral thermal comfort at moderately elevated temperature is capable of avoiding negative effects on perceived acute subclinical health symptoms, comfort, and cognitive performance. Two temperatures were examined: 23°C and 27°C. Twelve subjects were able to remain thermally comfortable at both temperatures by adjusting their clothing. They rated the physical environment, their comfort, the intensity of acute subclinical health symptoms, and their mental load, and they performed a number of cognitive tasks. Their physiological reactions were monitored. Their performance of several tasks was significantly worse at 27°C, and they reported increased mental load at this temperature. Skin temperature and humidity and respiration rate were higher, while blood oxygen saturation (SpO2) and pNN50 were lower at this temperature, the latter indicating increased stress. It is inferred that the observed physiological responses were mainly responsible for the negative effects on performance, as the subjects did not indicate any increased intensity of acute subclinical health symptoms although perceived air quality was worse at the higher temperature. The present results suggest that moderately elevated temperatures should be avoided even if thermal comfort can be achieved, as it may lead to reduced performance.  相似文献   

4.
In a warm and humid climate, increasing the temperature set point offers considerable energy benefits with low first costs. Elevated air movement generated by a personally controlled fan can compensate for the negative effects caused by an increased temperature set point. Fifty‐six tropically acclimatized persons in common Singaporean office attire (0.7 clo) were exposed for 90 minutes to each of five conditions: 23, 26, and 29°C and in the latter two cases with and without occupant‐controlled air movement. Relative humidity was maintained at 60%. We tested thermal comfort, perceived air quality, sick building syndrome symptoms, and cognitive performance. We found that thermal comfort, perceived air quality, and sick building syndrome symptoms are equal or better at 26°C and 29°C than at the common set point of 23°C if a personally controlled fan is available for use. The best cognitive performance (as indicated by task speed) was obtained at 26°C; at 29°C, the availability of an occupant‐controlled fan partially mitigated the negative effect of the elevated temperature. The typical Singaporean indoor air temperature set point of 23°C yielded the lowest cognitive performance. An elevated set point in air‐conditioned buildings augmented with personally controlled fans might yield benefits for reduced energy use and improved indoor environmental quality in tropical climates.  相似文献   

5.
In this study, 30 subjects were exposed to different combinations of air temperature (Ta: 24, 27, and 30°C) and CO2 level (8000, 10 000, and 12 000 ppm) in a high-humidity (RH: 85%) underground climate chamber. Subjective assessments, physiological responses, and cognitive performance were investigated. The results showed that as compared with exposure to Ta = 24°C, exposure to 30°C at all CO2 levels caused subjects to feel uncomfortably warm and experience stronger odor intensity, while increased mental effort and greater intensity of acute health symptoms were reported. However, no significant effects of Ta on task performance or physiological responses were found. This indicated that subjects had to exert more effort to maintain their performance in an uncomfortably warm environment. Increasing CO2 from 8000 to 12 000 ppm at all Ta caused subjects to report higher rates of headache, fatigue, agitation, and feeling depressed, although the results were statistically significant only at 24 and 27°C. The text typing performance and systolic blood pressure (SBP) decreased significantly at this exposure, whereas diastolic blood pressure (DBP) and thermal discomfort increased significantly. These effects suggest higher arousal/stress. No significant interaction effect of Ta and CO2 concentration on human responses was identified.  相似文献   

6.
In this study, we examined the cognitive performance of subtropically acclimatized subjects at an extreme high indoor temperature and the effect of decreased humidity on the cognitive performance at the high temperature. Forty-eight healthy subjects experienced the three exposure conditions: 26°C/relative humidity (RH) 70%, 39°C/RH50%, and 39°C/RH70% in a climate chamber. During 140-minute-long exposures to each thermal condition, they were required to perform cognitive tests that assess the perception, spatial orientation, concentration, memory, and thinking abilities. Meanwhile, their heart rate, core temperature, skin temperature, blood pressure, and body weight were measured and subjective responses, that is, thermal comfort, perceived air quality, and acute health symptoms were investigated. At the relative humidity of 70%, increasing indoor temperature from 26°C to 39°C caused a significant decrease in the accuracy of these cognitive tests. However, when the relative humidity decreased from 70% to 50% at 39°C, the accuracy of the cognitive tests increased significantly. Accordingly, the physiological and subjective responses of the subjects changed significantly with the changes in indoor temperature and humidity, which provided a basis to the variation in the cognitive performance. These results indicated that decreasing indoor humidity at extreme high temperature could improve the impaired cognitive performance.  相似文献   

7.
The extensive research interests in environmental temperature can be linked to human productivity / performance as well as comfort and health; while the mechanisms of physiological indices responding to temperature variations remain incompletely understood. This study adopted a physiological sensory nerve conduction velocity (SCV) as a temperature‐sensitive biomarker to explore the thermoregulatory mechanisms of human responding to annual temperatures. The measurements of subjects’ SCV (over 600 samples) were conducted in a naturally ventilated environment over all four seasons. The results showed a positive correlation between SCV and annual temperatures and a Boltzmann model was adopted to depict the S‐shaped trend of SCV with operative temperatures from 5°C to 40°C. The SCV increased linearly with operative temperatures from 14.28°C to 20.5°C and responded sensitively for 10.19°C‐24.59°C, while tended to be stable beyond that. The subjects’ thermal sensations were linearly related to SCV, elaborating the relation between human physiological regulations and subjective thermal perception variations. The findings reveal the body SCV regulatory characteristics in different operative temperature intervals, thereby giving a deeper insight into human autonomic thermoregulation and benefiting for built environment designs, meantime minimizing the temperature‐invoked risks to human health and well‐being.  相似文献   

8.
《Energy and Buildings》2005,37(1):65-75
The ONDOL is a conventional floor heating system in Korea. Eight healthy college students volunteered as the subjects to investigate the buttock responses to contact with 10 types of the ONDOL covering materials: mortar, plywood, artificial marble, PVC, rubber foam, tempered glass, steel, insulation mortar, carpet, and aluminum. The temperature of water supply flowing into the floor coil underneath the floor surface was altered from 15 to 40 °C at 5 °C intervals. Floor surface temperature, skin temperature including buttock and subjective thermal sensation were monitored. The study revealed that the lower the contact coefficient of covering material, the more stable the temperature fluctuations in the floor surface and the buttock skin were. The floor finishing material should be chosen by the heat flux based on the heating load, and the friendship to human body. Using regression analysis, the neutral temperature of the buttock was determined at 32.6 °C.  相似文献   

9.
An extended study of the effect of moderate thermal stress on the performance of tasks simulating aspects of industrial work has been under way since 1977. Factory workers were used as test subjects, each being exposed to a single test condition for a full shift in a mobile climate laboratory.Analyses completed so far reveal a fall in the performance of manipulative tasks of approximately 10% when finger skin temperatures (FST) fall to 20°C, and a further 10% at about 12°C. The FST of black male subjects typically reached these values at air temperatures about 4°C higher than gave rise to similar FST's in white subjects.For many of the tasks the air temperature which produced best performance in the range 20–38°C, was 32°C at a relative humidity of 25%. The subjects nevertheless reported preferred temperatures in the expected range of 20–23°C.  相似文献   

10.
The aim of the study was to determine the effect of a temperature of 29°C on performance in tasks involving different cognitive demands and to assess the effect on perceived performance, subjective workload, thermal comfort, perceived working conditions, cognitive fatigue, and somatic symptoms in a laboratory with realistic office environment. A comparison was made with a temperature of 23°C. Performance was measured on the basis of six different tasks that reflect different stages of cognitive performance. Thirty‐three students participated in the experiment. The exposure time was 3.5 h in both thermal conditions. Performance was negatively affected by slightly warm temperature in the N‐back working memory task. Temperature had no effect on performance in other tasks focusing on psychomotor, working memory, attention, or long‐term memory capabilities. Temperature had no effect on perceived performance. However, slightly warm temperature caused concentration difficulties. Throat symptoms were found to increase over time at 29°C, but no temporal change was seen at 23°C. No effect of temperature on other symptoms was found. As expected, the differences in thermal comfort were significant. Women perceived a temperature of 23°C colder than men.  相似文献   

11.
Draft is unwanted local convective cooling. The draft risk model of Fanger et al. (Energy and Buildings 12 , 21‐39, 1988) estimates the percentage of people dissatisfied with air movement due to overcooling at the neck. There is no model for predicting draft at ankles, which is more relevant to stratified air distribution systems such as underfloor air distribution (UFAD) and displacement ventilation (DV). We developed a model for predicted percentage dissatisfied with ankle draft (PPDAD) based on laboratory experiments with 110 college students. We assessed the effect on ankle draft of various combinations of air speed (nominal range: 0.1‐0.6 m/s), temperature (nominal range: 16.5‐22.5°C), turbulence intensity (at ankles), sex, and clothing insulation (<0.7 clo; lower legs uncovered and covered). The results show that whole‐body thermal sensation and air speed at ankles are the dominant parameters affecting draft. The seated subjects accepted a vertical temperature difference of up to 8°C between ankles (0.1 m) and head (1.1 m) at neutral whole‐body thermal sensation, 5°C more than the maximum difference recommended in existing standards. The developed ankle draft model can be implemented in thermal comfort and air diffuser testing standards.  相似文献   

12.
F. Zhang  R. de Dear 《Indoor air》2017,27(1):78-93
As one of the most common strategies for managing peak electricity demand, direct load control (DLC) of air‐conditioners involves cycling the compressors on and off at predetermined intervals. In university lecture theaters, the implementation of DLC induces temperature cycles which might compromise university students' learning performance. In these experiments, university students' learning performance, represented by four cognitive skills of memory, concentration, reasoning, and planning, was closely monitored under DLC‐induced temperature cycles and control conditions simulated in a climate chamber. In Experiment 1 with a cooling set point temperature of 22°C, subjects’ cognitive performance was relatively stable or even slightly promoted by the mild heat intensity and short heat exposure resulting from temperature cycles; in Experiment 2 with a cooling set point of 24°C, subjects’ reasoning and planning performance observed a trend of decline at the higher heat intensity and longer heat exposure. Results confirm that simpler cognitive tasks are less susceptible to temperature effects than more complex tasks; the effect of thermal variations on cognitive performance follows an extended‐U relationship with performance being relatively stable across a range of temperatures. DLC appears to be feasible in university lecture theaters if DLC algorithms are implemented judiciously.  相似文献   

13.
Formaldehyde is one of the most common indoor air pollutants in Chinese residences. This study introduces a novel laminated plate with adjustable surface temperature to remove gaseous formaldehyde. The plate is fabricated with activated carbon, polyimide, and copper foil via thermal compression. The plate can be regenerated in situ by applying a direct current to the copper foil. Adsorption‐regeneration cycle tests were conducted to evaluate the plate's formaldehyde removal performance. The overall removal efficiency of the fabricated laminated plate with glue mass fraction of 25% and thickness of 1.5 mm was about 30% at the face velocity of 0.8‐1.2 m/s. The pressure drop was about 5 Pa. Its removal ability can be regenerated in situ in 8 minutes by increasing the surface temperature to 80°C. The fabricated laminated plate showed good durability after 52 cycles of adsorption‐regeneration tests. The results indicate that the proposed laminated plate can enhance the purifying efficiency and enlarge the life span of ordinary, cheap sorbents. It makes cheap materials with low performance suitable for air purification.  相似文献   

14.
An experimental investigation of an evacuated tube solar air collector coupled to a latent thermal energy store for generating hot air when no solar radiation is incident was undertaken. Acetamide was used as a phase change material (PCM). The latent thermal energy store was integrated with the manifold of the solar collector and water was used as the working fluid transferring solar gain to the air being heated. The maximum measured temperature differential between the heated air and the ambient air was 37°C and 20.2°C during conditions of incident and non-incident solar radiation, respectively. This occurred using a circular fin configuration at a flow rate of 0.018?kg?s?1. The efficiency at low (0.018?kg?s?1) air flow rates was 0.05–0.50 times less as compared to high (0.035?kg?s?1) air flow rates. This system has advantages over systems using sensible storage as it can be used after sunset due to better heat storing capacity of the PCM.  相似文献   

15.
Several studies have already reported on the various effects of high temperature on the mechanical properties of fiber reinforced concrete (FRC). Some of these effects include changes in; compressive strength, compression toughness and splitting tensile strength. None of the previous studies have investigated the changes that might occur on the post-crack flexural response and flexural toughness. Post-crack (or peak) response and toughness is considered one of FRC’s key beneficial characteristics – as the purpose of adding fibers is to increase the energy absorption and load carrying capacity after an initial crack. In this study, the flexural toughness test according to ASTM C1018 was carried out on two types of concrete: plain concrete and fiber reinforced concrete with three different types of fiber (steel, polypropylene, and polyethylene) at 0.5% and 1.0% by volume fractions. Prior to the flexural test, the specimens were put in an oven chamber and subjected to high temperatures using the ISO/TR834 standards of: 400 °C, 600 °C and 800 °C. The results showed the typical load–deflection response of FRC was a double-peak response. The first peak represented the properties of concrete matrix and the second peak represented the properties of the fibers used. Under flexural load, instead of dropping (or remaining unchanged), the post-peak load and the toughness were found to increase at lower temperatures (400 °C) and later, decreased as the temperature increased (600 °C and 800 °C). Fiber type and content also played an important role. At a temperature of 400 °C, all FRCs exhibited higher flexural strength and increased post-peak response and toughness. A significant decrease in strength, toughness and load–deflection response was observed with synthetic or plastic FRC (PFRC) when the temperature approached 800 °C. When steel FRC (SFRC) was used, those effects were relatively small. It appears, SFRC has better heat resistance than the PFRC. The density (measured by ultrasonic pulse velocity) was found to decrease more in the PFRC than in the SFRC.  相似文献   

16.
This study examined airborne emissions from cigarette butts for styrene, 2-methyl-2-cyclopenten-1-one, naphthalene, triacetin, and nicotine. Ten experiments were conducted by placing butts in a stainless steel chamber and measuring the chemical concentrations in chamber air. Emission rates were determined from the concentrations. Triacetin and nicotine concentrations were roughly 50% of initial concentrations after 100 hours, while concentrations of other chemicals decayed to less than 10% of initial concentrations within 24 hours. Initial emission rates per cigarette butt ranged from 200 to 3500 ng h−1. Triacetin and nicotine emission rates at 25°C were 1.6 to 2.2 times higher than the rates at 20°C, while the emission rates of other chemicals at 25°C were 1.1 to 1.3 times higher than the rates at 20°C only during the first sampling period. The chemical concentrations and emission rates at 30°C were comparable or lower than the values at 25°C, possibly due to different batches of cigarettes used. The 24-hours emitted mass of nicotine from a cigarette butt at 25°C could be up to 14% of the literature reported nicotine masses emitted from a burning cigarette.  相似文献   

17.
Conditions in which exhaled and dermally emitted bioeffluents could be sampled separately or together (whole‐body emission) were created. Five lightly dressed males exhaled the air through a mask to another, identical chamber or without a mask to the chamber in which they were sitting; the outdoor air supply rate was the same in both chambers. The carbon dioxide concentration in the chamber with exhaled air was 2000 ppm. Chamber temperatures were 23°C or 28°C, and ozone was present or absent in the supply airflow. When dermally emitted bioeffluents were present, the perceived air quality (PAQ) was less acceptable, and the odor intensity was higher than when only exhaled bioeffluents were present. The presence or absence of exhaled bioeffluents in the unoccupied chamber made no significant difference to sensory assessments. At 28°C and with ozone present, the odor intensity increased and the PAQ was less acceptable in the chambers with whole‐body bioeffluents. The concentrations of nonanal, decanal, geranylacetone, and 6‐MHO were higher when dermally emitted bioeffluents were present; they increased further when ozone was present. The concentration of squalene then decreased and increased again at 28°C. Dermally emitted bioeffluents seem to play a major role in the sensory nuisance experienced when occupied volumes are inadequately ventilated.  相似文献   

18.
Streaklike coherent structures are consistently observed in boundary layer flames, but their role in modifying heat and mass transfer remains unknown. In the following experiment, a non-reactive thermal plume was employed to study analogous streaks in an environment where the local source of buoyancy could be directly modified. A horizontal hot plate was exposed to crossflow, and infrared thermography was successfully employed to capture thermal traces of streaks on the surface. Post-processing of surface temperature data enabled the quantification of important properties of streaks, such as location, spacing, width, and strength. The distribution of streak spacing was found to have a lognormal distribution. Mean streak spacing and width increased with downstream distance, indicating the amplification and aggregation of coherent structures. Streak spacing decreased when either the hot plate temperature increased from 150 °C to 300 °C or the wind speed increased from 0.5 to 1.2 m/s. Streaks were seen to modify the spanwise distribution of heat transfer to the surface, most notably when the hot plate temperature was increased from 150 °C to 300 °C.  相似文献   

19.
An experimental study of air heating system was carried out using a parabolic trough collector with a U-tube aluminium heat exchanger. An evacuated tube placed at the focal length of the parabolic trough collected the solar radiations reflected from the surface of parabolic trough. The air was used as a working fluid, which was heated by passing it through a U-shaped aluminium heat exchanger placed inside the evacuated tube. It was found that efficiency of the parabolic trough collector depends on the mass flow rate, solar intensity and use of fins. It was observed that by using fins at a high mass flow rate of 4.557?kg/h, the maximum temperature of 126°C was achieved which is 13.27% more than the maximum temperature obtained without fins. Furthermore, for a low-mass-flow rate of 1.69?kg/h, the maximum temperature obtained was 149°C.  相似文献   

20.
ABSTRACT

The thermal comfort of rural residents in China is studied to improve their living conditions and safeguard agricultural development. The present study recruited 30 healthy young people (50% male and 50% female) from rural areas of the hot and humid region of China and exposed them to a wide range of temperatures (20–32°C) and humidities (50% and 70%) in a climate chamber. Both the psychological and physiological responses were observed. The thermal neutral standard effective temperature (SET) was determined to be 26.8°C and the 90% thermal acceptable SET range was 22.9–30.7°C. Mean skin temperature and skin wetness were found to be good predictors for thermal comfort in the neutral-cool and neutral-warm conditions, respectively. When compared with the previous results from similar studies of urban participants living in naturally ventilated buildings, a significant divergence is found. Rural participants reported the same thermal sensation but felt more comfortable and acceptable under identical cool or warm conditions. Rural participants had the same neutral temperature, but a much wider acceptable temperature range. The reason for these differences between rural and urban people may be attributed to differences in local culture, expectations and environmental cognition.  相似文献   