 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, a magnesium alloy (AZ91) was coated with calcium phosphate using potentiostatic pulse-potential and constant-potential methods and the in vitro corrosion behaviour of the coated samples was compared with the bare metal. In vitro corrosion studies were carried out using electrochemical impedance spectroscopy and potentiodynamic polarization in simulated body fluid (SBF) at 37 °C. Calcium phosphate coatings enhanced the corrosion resistance of the alloy, however, the pulse-potential coating performed better than the constant-potential coating. The pulse-potential coating exhibited ~ 3 times higher polarization resistance than that of the constant-potential coating. The corrosion current density obtained from the potentiodynamic polarization curves was significantly less (~ 60%) for the pulse-deposition coating as compared to the constant-potential coating. Post-corrosion analysis revealed only slight corrosion on the pulse-potential coating, whereas the constant-potential coating exhibited a large number of corrosion particles attached to the coating. The better in vitro corrosion performance of the pulse-potential coating can be attributed to the closely packed calcium phosphate particles.  相似文献   

2.
The effect of addingd-fructose to simulated body fluid(SBF) on the corrosion behavior of AZ31 magnesium(Mg) alloy at 37.C and at a pH of 7.4 was studied by potentiodynamic polarization(PDP), electrochemical impedance spectroscopy(EIS), potentiostatic polarization and hydrogen(H2) collecting techniques,Raman spectroscopy technique, scanning electron microscopy(SEM), energy dispersive spectroscopy(EDS), X-ray diffraction(XRD), X-ray photoelectron spectroscopy analysis(XPS) and Fourier transformed infrared(FTIR). The results demonstrated that the addition of fructose enhanced the deposition of phosphates forming thick and compact corrosion products, which inhibited the transmission of aggressive ions into the Mg substrate. As a result, both the anodic dissolution of Mg and negative difference effect(NDE) were suppressed. Thus, the corrosion resistance of AZ31 Mgalloy in SBF was significantly improved.  相似文献   

3.
In vitro corrosion resistance of Lotus-type porous Ni-free stainless steels   总被引:1,自引:0,他引:1  
The corrosion behavior of three kinds of austenitic high nitrogen Lotus-type porous Ni-free stainless steels was examined in acellular simulated body fluid solutions and compared with type AISI 316L stainless steel. The corrosion resistance was evaluated by electrochemical techniques, the analysis of released metal ions was performed by inductively coupled plasma mass spectrometry (ICP-MS) and the cytotoxicity was investigated in a culture of murine osteoblasts cells. Total immunity to localized corrosion in simulated body fluid (SBF) solutions was exhibited by Lotus-type porous Ni-free stainless steels, while Lotus-type porous AISI 316L showed very low pitting corrosion resistance evidenced by pitting corrosion at a very low breakdown potential. Additionally, Lotus-type porous Ni-free stainless steels showed a quite low metal ion release in SBF solutions. Furthermore, cell culture studies showed that the fabricated materials were non-cytotoxic to mouse osteoblasts cell line. On the basis of these results, it can be concluded that the investigated alloys are biocompatible and corrosion resistant and a promising material for biomedical applications.  相似文献   

4.
The present research reports the synthesis of an innovative nanostructured composite film containing biphasic calcium phosphate (BCP) by the micro arc oxidation (MAO) method on AZ31 magnesium alloy. Nanometric structure of the used hydroxyapatite powder and the coatings were characterized by means of transmission and field-emission scanning electron microscope, respectively. Electrochemical behaviors of the pure MAO and nanocomposite films were also evaluated by electrochemical impedance spectroscopy and potentiodynamic polarization tests in simulated body fluid (SBF) environment. The results showed higher corrosion resistance of nanocomposite film compared to pure MAO coating, which was related to the blocking feature of the nanoparticles from the diffusing of the corrosive medium through the substrate. In addition, by immersing the specimens in simulated body fluid, greater apatite forming ability of the nanocomposite coating was proved.  相似文献   

5.
Titanium and cobalt alloys, as well as some stainless steels, are among the most frequently used materials in orthopaedic surgery. In industrialized countries, stainless steel devices are used only for temporary implants due to their lower corrosion resistance in physiologic media when compared to other alloys. However, due to economical reasons, the use of stainless steel alloys for permanent implants is very common in developing countries. The implantation of foreign bodies is sometimes necessary in the modern medical practice. However, the complex interactions between the host and the can implant weaken the local immune system, increasing the risk of infections. Therefore, it is necessary to further study these materials as well as the characteristics of the superficial film formed in physiologic media in infection conditions in order to control their potential toxicity due to the release of metallic ions in the human body. This work presents a study of the superficial composition and the corrosion resistance of AISI 316L stainless steel and the influence of its main alloying elements when they are exposed to an acidic solution that simulates the change of pH that occurs when an infection develops. Aerated simulated body fluid (SBF) was employed as working solution at 37 °C. The pH was adjusted to 7.25 and 4 in order to reproduce normal body and disease state respectively. Corrosion resistance was measured by means of electrochemical impedance spectroscopy (EIS) and anodic polarization curves.  相似文献   

6.
The corrosion behavior of pure Mg,AZ31,and AZ91D were evaluated in various in vitro and in vivo environments to investigate the potential application of these metals as biodegradable implant materials.DC polarization tests and immersion tests were performed in different simulated body solutions,such as distilled(DI) water,simulated body fluid(SBF) and phosphate buffered solution(PBS).Mg/Mg alloys were also implanted in different places in a mouse for in vivo weight loss and biocompatibility investigations.The in vivo subcutis bio-corrosion rate was lower than the corrosion rate for all of the in vitro simulated corrosive environments.The Mg/Mg alloys were biocompatible based on histology results for the liver,heart,kidney,skin and lung of the mouse during the two months implantation.Optical microscopy and scanning electron microscopy were carried out to investigate the morphology and topography of Mg/Mg alloys after immersion testing and implantation to understand the corrosion mechanisms.  相似文献   

7.
The main purpose of this paper is to investigate the effect of corrosion on mechanical behaviors of the Mg-Zn-Zr alloy immersed in simulated body fluid (SBF) with different immersion times. The corrosion behavior of the materials in SBF was determined by immersion tests. The surfaces of the corroded alloys were examined by SEM. The tensile samples of the extruded Mg-2Zn-0.8Zr magnesium alloy were immersed in the SBF for 0, 4, 7, 10, 14, 21 and 28 d. The tensile mechanical behaviors of test samples were performed on an electronic tensile testing machine. SEM was used to observe the fracture morphology. It was found that with extension of the immersion time, the ultimate tensile strength (UTS), yield strength (YS) and elongation (EL) of the Mg-2Zn-0.8Zr samples decreased rapidly at first and then decreased slowly. The main fracture mechanism of the alloy transformed from ductile fracture to cleavage fracture with the increasing immersion times, which can be attributed to stress concentration and embrittlement caused by pit corrosion.  相似文献   

8.
A phosphating treatment was applied to Mg–Mn–Zn alloy in order to improve the corrosion resistance. Surface morphology and phase constitute were observed and identified by SEM, EDS, SAXS, XRD and XPS. SEM observation showed that a rough and crystalline reaction layer was formed on the surface of Mg alloy. With the increasing of phosphating time, the layer became thicker and denser. It has been showed that the reaction layer was mainly composed of brushite (CaHPO4 · 2H2O). Small amount of Zn2+ was also detected by XPS and EDS. The corrosion resistance of the phosphated samples was measured by the electrochemical polarization and the immersion test in comparison with the bare alloy. The results manifested that the corrosion resistance of Mg alloy was improved by the phosphating treatment, and the corrosion resistance increased with the increase of the phosphating time within 50 min. Immersion tests showed that the phosphate layer could protect magnesium alloy from fast corrosion. The brushite layer has been transformed into hydroxyapatite (HA) during the immersion in the simulated body fluid (SBF) solution, which suggested the brushite layer could provide good biocompatibility.  相似文献   

9.
D. Krupa  J. Baszkiewicz  A. Barcz  A. Biliński 《Vacuum》2007,81(10):1310-1313
The corrosion resistance and bioactivity of Ti6Al4V alloy after calcium-ion implantation were examined. Polished samples were implanted with a dose of 1017 Na+/cm2 at a beam energy of 25 keV. The chemical composition of the surface layer formed during the implantation was determined by XPS and SIMS. The bioactivity of the samples was evaluated by soaking them in a simulated body fluid (SBF) at 37 °C for 168 and 720 h. The corrosion resistance in SBF at 37 °C was determined by electrochemical methods after exposure in SBF for various times. The surfaces of the samples before and after examinations were observed by optical microscopy, SEM-EDS and AFM.The results of the corrosion examinations indicated that under stationary conditions and after short-term exposures, the calcium-ion implanted titanium alloy had an increased corrosion resistance, but during the anodic polarization, calcium-implanted samples underwent pitting corrosion. The microscopic observations show that the precipitations of calcium phosphates are present on the surface, but they do not form a continuous layer.  相似文献   

10.
The key to use magnesium alloys as suitable biodegradable implants is how to adjust their degradation rates. We report a strategy to prepare biocompatible ceramic coating with improved biocorrosion resistance property on AZ91D alloy by microarc oxidation (MAO) in a silicate-K2ZrF6 solution with and without Ca(H2PO4)2 additives. The microstructure and biocorrosion of coatings were characterized by XRD and SEM, as well as electrochemical and immersion tests in simulated body fluid (SBF). The results show that the coatings are mainly composed of MgO, Mg2SiO4, m-ZrO2 phases, further Ca containing compounds involve the coating by Ca(H2PO4)2 addition in the silicate-K2ZrF6 solution. The corrosion resistance of coated AZ91D alloy is significantly improved compared with the bare one. After immersing in SBF for 28 d, the Si-Zr5-CaO coating indicates a best corrosion resistance performance.  相似文献   

11.
张雅静  时贵安  郭廷廷  陆前 《材料导报》2016,30(Z2):361-364
镁合金降解速率过快限制了其作为生物医用材料的应用,对镁合金降解速率的控制成为了研究的热点。采用仿生法在MgZnSrCa合金基体表面形成羟基磷灰石涂层。利用X射线衍射仪、扫描电子显微镜及能谱仪对涂层结构、形貌和成分进行分析和观察。通过失重法、析氢法、pH值测定等方法,研究不同涂层形貌的合金试样在人体模拟体液(SBF)中的降解速率。实验结果表明:羟基磷灰石(HA)涂层可以降低合金的降解速率,可以通过控制涂层形貌对合金的降解速率进行控制。  相似文献   

12.
Groove pressing (GP) has been successfully adopted to achieve fine grain size up to 7 μm in AZ31 magnesium alloy with an initial grain size of 55 μm. The effect of microstructural evolution and surface features on wettability, corrosion resistance, bioactivity and cell adhesion were investigated with an emphasis to study the influence of deposited phases when the samples were immersed in simulated body fluid (SBF 5 ×). The role of microstructure was also evaluated without any surface treatments or coatings on the material. GPed samples exhibit improved hydrophilicity compared to the annealed sample. After immersion in SBF, specimens were characterized using scanning electron microscopy (SEM), energy dispersive X-ray (EDAX) analysis and X-ray diffraction (XRD) methods. More amount of white precipitates composed of hydroxyapatite and magnesium phosphate along with magnesium hydroxide was observed on the surfaces of groove pressed specimens as compared to the annealed specimens with an increase in immersion time in SBF. Corrosion behavior of the samples estimated using potentiodynamic polarization curves indicate good corrosion resistance for GPed samples before and after immersion in SBF. The MTT assay using rat skeletal muscle (L6) cells revealed that both the processed and unprocessed samples are nontoxic and cell adhesion was promising for GPed sample.  相似文献   

13.
Magnesium alloys are very biocompatiable and show promise for use in orthopaedic implant. Significant progress of research on bioabsorbable magnesium stents and orthopaedic bones has been achieved in recent years. The issues on degradation, hydrogen evolution, and corrosion fatigue and erosion corrosion of magnesium alloys and various influencing factors in simulated body fluid (SBF) are discussed. The research progress on magnesium and its alloys as biomaterials and miscellaneous approaches to enhancement in corrosion resistance is reviewed. Finally the challenges and strategy for their application as orthopaedic biomaterials are also proposed.  相似文献   

14.
The chemical and physical processes of magnesium in simulated body fluid (SBF) were investigated. The corrosion rate of magnesium was measured after 3, 5, 7, 14 and 21 days of immersion, respectively. It was found that the corrosion rate decreased with increasing immersion time, while the pH of SBF changed inversely. Network-like cracks and pits were the main damages resulting from corrosion, and the localized buildup of chloride ions was the major cause of pit formation.  相似文献   

15.
Dicalcium phosphate dihydrate (DCPD) coating was deposited on the substrate surface of magnesium alloy with solution treatment. The microstructures and corrosion behaviors of the DCPD-coated samples before and after immersion in simulated body fluid (SBF) for different times were investigated. It is important to note that DCPD was not only transformed into hydroxyapatite (HA) but also induced HA precipitation after immersion in SBF. An HA-like coating was generated on the substrate surface in a two step process involving an initial coating with DCPD, resulting in the corrosion resistance increasing along with the corrosion mechanism changing with increase to soaking time.  相似文献   

16.
Hydroxyapatite (HA) was coated onto pure magnesium (Mg) with an MgF2 interlayer in order to reduce the surface corrosion rate and enhance the biocompatibility. Both MgF2 and HA were successfully coated in sequence with good adhesion properties using the fluoride conversion coating and aerosol deposition techniques, respectively. In a simulated body fluid (SBF), the double layer coating remarkably enhanced the corrosion resistance of the coated Mg specimen. The in vitro cellular responses of the MC3T3-E1 pre-osteoblasts were examined using a cell proliferation assay and an alkaline phosphatase (ALP) assay, and these results demonstrated that the double coating layer also enhanced cell proliferation and differentiation levels. In the in vivo study, the HA/MgF2 coated Mg corroded less than the bare Mg and had a higher bone-to-implant contact (BIC) ratio in the cortical bone area of the rabbit femora 4 weeks after implantation. These in vitro and in vivo results suggested that the HA coated Mg with the MgF2 interlayer could be used as a potential candidate for biodegradable implant materials.  相似文献   

17.
Magnesium alloy stent has been employed in animal and clinical experiment in recent years. It has been verified to be biocompatible and degradable due to corrosion after being implanted into blood vessel. Mg–Y–Gd–Nd alloy is usually used to construct an absorbable magnesium alloy stent. However, the corrosion resistant of as cast Mg–Y–Gd–Nd alloy is poor relatively and the control of corrosion rate is difficult. Aiming at the requirement of endovascular stent in clinic, a new biomedical Mg–Zn–Y–Nd alloy with low Zn and Y content (Zn/Y atom ratio 6) was designed, which exists quasicrystals to improve its corrosion resistance. Additionally, sub-rapid solidification processing was applied for preparation of corrosion-resisting Mg–Zn–Y–Nd and Mg–Y–Gd–Nd alloys. Compared with the as cast sample, the corrosion behavior of alloys in dynamic simulated body fluid (SBF) (the speed of body fluid: 16 ml/800 ml min−1) was investigated. The results show that as sub-rapid solidification Mg–Zn–Y–Nd alloy has the better corrosion resistance in dynamic SBF due to grain refinement and fine dispersion distribution of the quasicrystals and intermetallic compounds in α-Mg matrix. In the as cast sample, both Mg–Zn–Y–Nd and Mg–Y–Gd–Nd alloys exhibit poor corrosion resistance. Mg–Zn–Y–Nd alloy by sub-rapid solidification processing provides excellent corrosion resistance in dynamic SBF, which open a new window for biomedical materials design, especially for vascular stent application.  相似文献   

18.
Corrosion tests for medical materials are often performed in simulated body fluids (SBF). When SBF are used for corrosion measurement, the open question is, how well they match the conditions in the human body. The aim of the study was to compare the corrosion behaviour of different experimental magnesium alloys in human whole blood and PBSminus (phosphate buffered saline w/o Ca and Mg) as a simulated body fluid by gravimetric weight measurements and microscopic evaluation. Eight different experimental magnesium alloys, containing neither Mn nor other additives, were manufactured. With these alloys, a static immersion test in PBSminus and a dynamic test using the Chandler-loop model with human whole blood over 6 h were performed. During the static immersion test, the samples were weighed every hour. During the dynamic test, the specimens were weighed before and after the 6 h incubation period in the Chandler-loop. From both tests, the total mass change was calculated for each alloy and the values were compared. Additionally, microscopic pictures from the samples were taken at the end of the test period. All alloys showed different corrosion behaviour in both tests, especially the alloys with high aluminium content, MgAl9 and MgAl9Zn1. Generally, alloys in PBS showed a weight gain due to generation of a microscopically visible corrosion layer, while in the blood test system a more or less distinct weight loss was observed. When alloys are ranked according to corrosion susceptibility, the results differ also between the test systems. The MgAl9 alloy, showing the most pronounced corrosion in PBS, was one of the least corroding alloys under simulated in vivo conditions in blood. Thus, the ranking concerning clinical suitability of the magnesium alloys tested in this study is different, depending on the used electrolyte and the kind of method. For a possible clinical use, the alloy MgAl9Zn1 might be preferable for further investigations.  相似文献   

19.
Blood triggered corrosion of magnesium alloys   总被引:1,自引:0,他引:1  
Intravascular stents manufactured out of bioabsorbable magnesium (Mg) or Mg-alloys are considered as auspicious candidates for the next stent generation. However, before clinical application numerous physical and biological tests, especially to predict the clinically highly important degradation kinetics in vivo, have to be performed. In a Chandler-Loop model, the initial degradation of eight different magnesium alloys during 6 h in contact with human whole blood was investigated. The magnesium release varied between 0.91 ± 0.33 mg/cm2 (MgAl9Zn1) and 2.57 ± 0.38 mg/cm2 (MgZn1). No correlation could be found with Mg release data obtained after immersion in simulated body fluid (SBF). This pilot study showed that Mg corrosion is highly influenced by the biological test environment (SBF or blood, etc.) and that a modified Chandler-Loop model with human whole blood may be superior to predict corrosion of Mg alloys under clinical conditions than the SBF models presently used.  相似文献   

20.
The effect of a hybrid coating, calcium phosphate (CaP) + polylactic acid (PLA), on a magnesium alloy on its in vitro degradation (general and localized) behaviour was studied for potential load-bearing biodegradable mini-implant applications. CaP was coated on a magnesium alloy, AZ91, using an electrochemical deposition method. A spin coating method was used to coat PLA on the CaP coated alloy. In vitro degradation performance of the alloy with hybrid coating was evaluated using electrochemical impedance spectroscopy (EIS) in simulated body fluid (SBF). The EIS results showed that the hybrid coating enhanced the degradation resistance of the alloy by more than two-order of magnitude as compared to the bare alloy and one-order of magnitude higher than that of the CaP coated alloy, after 1 h exposure in simulated body fluid (SBF). Long-term (48 h) EIS results also confirmed that the hybrid coating performed better than the bare alloy and the CaP coated alloy. Importantly, the hybrid coating improved the localized degradation resistance of the alloy significantly, which is critical for better in service mechanical integrity.  相似文献   