首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Automated analysis of submicron particles by computer-controlled scanning electron microscopy is generally possible. The minimum diameter of the detectable particles is dependent on the mean atomic number of the particles and the operating parameters of the scanning microscope. The main limitation with regard to particle size is set by the quality of the particle detection system, which generally is the backscatter electron detector. The accuracy of the results of the x-ray analyses is very often strongly affected by specimen damage, omnipresent especially for environmental particles even at low electron energies and probe currents. With the exception for light elements, the detection limit is approximately 1 wt%. Device-related limitations to automated analysis may be specimen drift and an unreliable autofocus function.  相似文献   

2.
Atomic force microscopy (AFM) and scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS) have been used for both morphological and elemental mass analysis study of atmospheric particles. As part of the geometrical particle analysis, and in addition to the traditional height profile measurement of individual particles, AFM was used to measure the volume relative to the projection area for each particle separately, providing a particle shape model. The element identification was done by the EDS analysis, and the element mass content was calculated based on laboratory calibration with particles of known composition. The SEM-EDS mass measurements from two samples collected at 150 and 500 m above the surface of the Mediterranean Sea were found to be similar to mass calculations derived from the AFM volume measurements. The AFM results show that the volume of most of the aerosols that were identified as soluble marine sulfate and nitrate aerosol particles can be better estimated using cylindrical shapes than spherical or conical geometry.  相似文献   

3.
Vladár AE  Radi Z  Postek MT  Joy DC 《Scanning》2006,28(3):133-141
Experimental nanotips have shown significant improvement in the resolution performance of a cold field emission scanning electron microscope (SEM). Nanotip electron sources are very sharp electron emitter tips used as a replacement for the conventional tungsten field emission (FE) electron sources. Nanotips offer higher brightness and smaller electron source size. An electron microscope equipped with a nanotip electron gun can provide images with higher spatial resolution and with better signal-to-noise ratio. This could present a considerable advantage over the current SEM electron gun technology if the tips are sufficiently long-lasting and stable for practical use. In this study, an older field-emission critical dimension (CD) SEM was used as an experimental test platform. Substitution of tungsten nanotips for the regular cathodes required modification of the electron gun circuitry and preparation of nanotips that properly fit the electron gun assembly. In addition, this work contains the results of the modeling and theoretical calculation of the electron gun performance for regular and nanotips, the preparation of the SEM including the design and assembly of a measuring system for essential instrument parameters, design and modification of the electron gun control electronics, development of a procedure for tip exchange, and tests of regular emitter, sharp emitter and nanotips. Nanotip fabrication and characterization procedures were also developed. Using a "sharp" tip as an intermediate to the nanotip clearly demonstrated an improvement in the performance of the test SEM. This and the results of the theoretical assessment gave support for the installation of the nanotips as the next step and pointed to potentially even better performance. Images taken with experimental nanotips showed a minimum two-fold improvement in resolution performance than the specification of the test SEM. The stability of the nanotip electron gun was excellent; the tip stayed useful for high-resolution imaging for several hours during many days of tests. The tip lifetime was found to be several months in light use. This paper summarizes the current state of the work and points to future possibilities that will open when electron guns can be designed to take full advantage of the nanotip electron emitters.  相似文献   

4.
A method has been developed to characterize large populations of individual respirable particles. With the use of custom data collection and data correlation computer software, the same set of particles can be analyzed in multiple instruments. The method is demonstrated by the analysis of a sample of hard-metal particles. A series of particles are analyzed by Auger electron spectroscopy, and then the same particles are analyzed by scanning electron microscopy-energy dispersive spectroscopy.  相似文献   

5.
A consortium of microorganisms with the capacity to degrade crude oil has been characterized by means of confocal laser scanning microscopy (CLSM), transmission electron microscopy (TEM), and scanning electron microscopy (SEM). The analysis using CLSM shows that Microcoleus chthonoplastes is the dominant organism in the consortium. This cyanobacterium forms long filaments that group together in bundles inside a mucopolysaccharide sheath. Scanning electron microscopy and transmission electron microscopy have allowed us to demonstrate that this cyanobacterium forms a consortium primarily with three morphotypes of the heterotrophic microorganisms found in the Microcoleus chthonoplastes sheath. The optimal growth of Microcoleus consortium was obtained in presence of light and crude oil, and under anaerobic conditions. When grown in agar plate, only one type of colony (green and filamentous) was observed.  相似文献   

6.
Microchemical glass standards were used to validate a quantitation method based on peak-to-background (P/B) ratios from electron probe x-ray microanalysis spectra. This standardless method was applied to the determination of concentrations of individual particles from Malpha or Lalpha lines, as well as from Kalpha lines. The algorithm was tested on particulate glass samples for diameters ranging from 1 to 20 microm. The determined concentrations did not depend on particle size. The certified values for elements were well matched, except for Na, which may migrate under electron bombardment. Finally, classification of qualitative results obtained for aerosol particles was completed by the P/B quantitative method.  相似文献   

7.
We report a simple method to study the elemental content in cultured human adherent cells by electron probe X-ray microanalysis with scanning electron microscopy. Cells were adapted to grow on polycarbonate tissue culture cell inserts, washed with distilled water, plunge-frozen with liquid nitrogen and freeze-dried. Unstained, freeze-dried cultured cells were visualized in the secondary and backscattered electron imaging modes of scanning electron microscopy. With backscattered electron imaging it was possible to identify unequivocally major subcellular compartments, i.e. the nucleus, nucleoli and cytoplasm. X-ray microanalysis was used simultaneously to determine the elemental content in cultured cells at the cellular level. In addition, we propose some improvements to optimize backscattered electron and X-ray signal collection. Our findings demonstrate that backscattered electron imaging offers a powerful method to examine whole, freeze-dried cultured cells for scanning electron probe X-ray microanalysis.  相似文献   

8.
Lorusso GF  Joy DC 《Scanning》2003,25(4):175-180
By applying the basic principles of metrology we discuss how to define the standards that any experimental method to measure resolution has to obey. Our results clearly indicate the need to apply a calibration procedure when designing algorithms to estimate resolution to satisfy accuracy requirements. Similarly, the precision of an algorithm has to be clearly specified. We compare here the performances of a variety of commonly used implementations of published methods, with that of an algorithm based on an approach known to be reliable. Our results confirm that when an algorithm is designed with the clear intent of satisfying metrology requirements, it demonstrates excellent accuracy, precision, and lack of sensitivity to the noise level, as is desirable. As a consequence, the algorithm will have the ability to measure accurately the point spread function convoluted in the image, thus paving the way for quantitative deconvolution techniques.  相似文献   

9.
The objective of this study has been to characterize sialolith, a calcium phosphate deposit that develops in the human oral cavity, by high-resolution field emission scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The morphological and chemical data obtained helped in the determination of their formation mechanism in salivary glands. Sialoliths in the submandibular salivary glands may arise secondary to sialodenitis, but not via a luminal organic nidus. We believe this is the first study that characterizes a sialolith by XPS.  相似文献   

10.
A number of seemingly fibrous particles are found by evaluation of dust measurements of the industrial mineral vermiculite in accordance with German Guideline VDI 3492, part 2 for “measurements of inorganic fibrous particles- SEM method.” A more thorough investigation based upon an extension of the measuring method proves the nonfibrous morphology of practically all of these particles. The basic idea of this extension is to tilt the filter holder of the electron microscope and to check the exact orientation of the particles on the filter, an examination which is necessary to determine their true length and diameter. The result indicates that only very few fibrous particles actually exist. In the case of vermiculite, these fibrous particles are rolled up and detached flakes called “scrolls.” The systematic error inherent in VDI 3492, part 2, without extension can be quantified in the case of vermiculite to have a factor > 50, that is, fibre counts obtained are more than 50 times too high.  相似文献   

11.
Cell biologists probing the physiologic movement of macromolecules and solutes across the fenestrated microvascular endothelial cell have used electron microscopy to locate the postulated pore within the fenestrae. Prior to the advent of in-lens field-emission high-resolution scanning electron microscopy (HRSEM) and ultrathin m et al coating technology, quick-freeze, platinum-carbon replica and grazing thin-section transmission electron microscopy (TEM) methods provided two-dimensional or indirect imaging methods. Wedge-shaped octagonal channels composed of fibrils interwoven in a central mesh were depicted as the filtering structures of fenestral diaphragms in images of platinum replicas enhanced by photographic augmentation. However, image accuracy was limited to replication of the cell surface. Subsequent to this, HRSEM technology was developed and provided a high-fidelity, three-dimensional topographic image of the fenestral surface directly from a fixed and dried bulk adrenal specimen coated with a 1 nm chromium film. First described from TEM replicas, the “flower-like” structure comprising the fenestral pores was readily visualized by HRSEM. High-resolution images contained particulate ectodomains on the lumenal surface of the endothelial cell membrane. Particles arranged in a rough octagonal shape formed the fenestral rim. Digital acquisition of analog photographic recordings revealed a filamentous meshwork in the diaphragm, thus confirming and extending observations from replica and grazing section TEM preparations. Endothelial cell pockets, first described in murine renal peritubular capillaries, were observed in rhesus and rabbit adrenocortical capillaries. This report features recent observations of fenestral diaphragms and endothelial pockets fitted with multiple diaphragms utilizing a Schottky field-emission electron microscope. In-lens staging of bulk and thin section specimens allowed tandem imaging in HRSEM and scanning TEM modes at 25 kV.  相似文献   

12.
A novel secondary electron detection system combining a two‐stage detector head and a differential pumping system is presented. The detector head consisted of a scintillation Everhart‐Thornley detector and a microsphere plate, separating it from the lower vacuum in the intermediate chamber (below 0.1 mbar). The system was arranged asymmetrically, which should contribute to a lower gas leakage through the plate and a longer life span of the plate. The system offered all the advantages of the scintillator detector in a wide range of gas pressures, from high vacuum to those of the order of 10 mbar, typical of high‐pressure scanning electron microscopy.  相似文献   

13.
This study has investigated the potential of environmental electron microscopy techniques for studying the structure of polymer‐based electronic devices. Polymer blend systems composed of F8BT and PFB were examined. Excellent contrast, both topographical and compositional, can be achieved using both conventional environmental scanning electron microscopy (ESEM) and a transmission detector giving an environmental scanning transmission electron microscope (ESTEM) configuration. Controllable charging effects present in the ESEM were observed, giving rise to a novel voltage contrast. This shows the potential of such contrast to provide excellent images of phase structure and charge distributions.  相似文献   

14.
Rouse JH  White ST  Ferguson GS 《Scanning》2004,26(3):131-134
A method for preparing and observing clay platelets for size and shape analysis using scanning electron microscopy (SEM) was developed. Samples of the clay platelets were prepared by polyelectrolyte-assisted adsorption onto a pyrolytic graphite surface. The use of graphite as a substrate was advantageous because of the low number of secondary electrons emitted from it during imaging by SEM. The resulting low background noise allowed the emission from the approximately 1 nm thick clay sheets to be clearly visualized. Images of centrifuged montmorillonite showed large exfoliated platelets with lateral dimensions between 200 and 600 nm. In contrast, uncentrifuged montmorillonite appeared to contain a large amount of unexfoliated clusters. Although it was not possible to obtain high-quality images of the smaller sheets of Laponite RD, the images of this material did contain size features comparable to the approximately 30 nm2 size reported previously using light scattering, as well as transmission electron and atomic force microscopies.  相似文献   

15.
16.
17.
Case studies will be presented in which environmental scanning electron microscopy (ESEM) has been used to provide unique insight into the role of microorganisms in deterioration processes. ESEM is an excellent tool for demonstrating spatial relationships between microorganisms and substrata because hydrated, nonconducting samples can be viewed with a minimum of manipulation. Copper and iron-rich deposits associated with bacteria were detected within corrosion layers on copper and steel surfaces, respectively. Fungal mycelia growing on wooden storage spools were shown to penetrate protective grease on carbon steel wire rope in contact with the spool and to cause localized corrosion. Large numbers of marine bacteria were documented within paint blisters and disbonded regions of fiber-reinforced polymeric composites. In both cases, it appears that microbial gas production resulted in mechanical damage to the substrata.  相似文献   

18.
A digital video plotter (DVP, Leica), the personal computer equivalent of an analytical plotter, was used to measure the coordinates of points chosen from stereo pair images of the surface of frozen hydrated lung imaged at magnifications of 2000 and 5000x with a low-temperature scanning electron microscope (SEM). Rat lung tissue was frozen in vivo with a liquid nitrogen cryoprobe under carefully controlled physiologic conditions. At slow freezing rates, water in the aqueous layer at the surface of the lung segregates into ice crystals (dendrites) which branch in the plane of the surface. Coordinates of points on dendrite surfaces were measured by the DVP and passed to TERRAMODEL (Plus III Software, a land modeling program) where they were used to generate a three-dimensional model, from which surface area and planimetric area of the lung surface were calculated. Additional measurements were made at the top and bottom of the ice structures and a Basic language program was written to calculate the volume of ice on the lung surface. Digital photogrammetry coupled with low-temperature SEM of frozen samples allows measurement of water and water-containing microstructures ubiquitous in biology.  相似文献   

19.
Raynald Gauvin 《Scanning》1999,21(6):388-393
This paper presents a new correction procedure for quantitative x-ray microanalysis in the environmental or variable pressure scanning electron microscope (SEM). This method is based on a plot of the measured intensity as a function of the fraction of nonscattered beam intensity, fp. The theory predicts that the plot should be linear and the corrected intensity is given for fp = 1. The advantage is that such a plot is valid for any measured pressures, which is not the case with the usual pressure correction methods. To use this method, a simple equation is derived to compute fp. Other variations of this correction procedure are also presented. Comparison with measurements performed by Mansfield (1999) show the great consistency of this method.  相似文献   

20.
Griffin BJ 《Scanning》2000,22(4):234-242
An electron-based technique for the imaging of crystal defect distribution such as material growth histories in non- and poorly conductive materials has been identified in the variable pressure or environmental scanning electron microscope. Variations in lattice coherence at the meso-scale can be imaged in suitable materials. Termed charge contrast imaging (CCI), the technique provides images that correlate exactly with emitted light or cathodoluminescence in suitable materials. This correlation links cathodoluminescence and an electron emission. The specific operating conditions for observation of these images reflect a complex interaction between the electron beam, the positive ions generated by electron-gas interactions in the chamber, a biased detector, and the sample. The net result appears to be the suppression of all but very near surface electron emission from the sample, probably from of the order of a few nanometres. Consequently, CCI are also sensitive to very low levels of surface contaminants. Successful imaging of internal structures in a diverse range of materials indicate that the technique will become an important research tool.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号