Many factors affect the airflow patterns, thermal comfort, contaminant removal efficiency and indoor air quality at individual workstations in office buildings. In this study, four ventilation systems were used in a test chamber designed to represent an area of a typical office building floor and reproduce the real characteristics of a modern office space. Measurements of particle concentration and thermal parameters (temperature and velocity) were carried out for each of the following types of ventilation systems: (a) conventional air distribution system with ceiling supply and return; (b) conventional air distribution system with ceiling supply and return near the floor; (c) underfloor air distribution system; and (d) split system. The measurements aimed to analyse the particle removal efficiency in the breathing zone and the impact of particle concentration on an individual at the workstation. The efficiency of the ventilation system was analysed by measuring particle size and concentration, ventilation effectiveness and the indoor/outdoor ratio. Each ventilation system showed different airflow patterns and the efficiency of each ventilation system in the removal of the particles in the breathing zone showed no correlation with particle size and the various methods of analyses used.  相似文献   

2.
This paper describes tests of thermal comfort and air distribution performance of two relatively new occupant-controlled localized ventilation (also called task ventilation) systems. The first is a raisd-floor distribution system providing air through grilles in the floor panels, and the second is a desk-mounted unit supplying conditioned air at desktop level. The tests were performed in a new controlled environment chamber (CEC) having unique capabilities for detailed studies of space conditioning and thermal comfort in office environments. Measurements were made in a mockup of a typical partitioned open-plan office, and the resulting temperature and air velocity distributions are reported for a variety of system- and locally controlled conditions. Comfort model predictions are presented to describe the degree of environmental control and range of occupant comfort levels produced in the workstations. The results are also compared to those produced by a conventional ceiling supply system. The tests investigated the effects of supply volume, supply location, supply vent orientation, supply/return temperature difference, heat load density, and workstation size and layout. Temperature differences in the range of 1–2.5°C were observed between adjacent workstations, and local air velocities in the vicinity of outlets could exceed 3 m/s. Such wide-ranging values could violate existing comfort standards (ASHRAE, 1981; ISO, 1984), if strictly interpreted. However since these systems put the local thermal conditions within the workstations under the direct control of their occupants, it is recommended that the standards grant exceptions to such systems.  相似文献   

3.
Influence of air supply parameters on indoor air diffusion   总被引:6,自引:0,他引:6  
This paper presents the field distributions of air velocity, temperature, contaminant concentration, and thermal comfort in an office with displacement ventilation for different air supply parameters such as the effective area, shape, and dimension of the diffuser and the turbulence intensity, flow rate, and temperature of the air supplied. The research is conducted numerically by using an airflow computer program based on a low-Reynolds-number k-ε model of turbulence. It can be concluded that the effective area, shape, and dimension of the diffuser and the turbulence intensity of the air supplied have little effect on the room air diffusion except at floor level. The influence of the flow rate and temperature of the air supplied is very significant on the air diffusion as well as on the thermal comfort and indoor air quality.  相似文献   

4.
下送上回通风方式目前得到了广泛的研究应用,其供冷运行时就是置换通风,但同样一套通风系统在一些地区的寒冷季节则有可能需要作供暖运行.为了获得下送上回通风系统在分别作供冷与供暖运行时的具体性能参数,本文应用实验测试与计算流体力学(CFD)模拟的方法研究了置于环境实验室内的某办公环境.研究中分析比较了该办公环境内的空气速度、温度以及追踪气体污染物的浓度分布.研究结果表明,下送上回通风方式作供冷运行时空气温度及污染物浓度分层现象明显,空气处于半混合状态,置换效果较好;作供暖运行时,温度及污染物浓度趋于均匀,通风系统性能接近于混合送风系统,不具备良好的抑制交叉污染的能力.  相似文献   

5.
This study compares thermal environment of two air distribution systems in an office setting. Airflow, heat and mass (water vapor and contaminant gas) transfer in steady-state condition are modeled for an underfloor air distribution system and an overhead air distribution system. The models include a typical cubicle in a large office floor with a chair, a desk with a personal computer on top, and heat sources such as seated person, desktop computer, and lights. For underfloor air distribution system, cool air enters the occupied zone through an inlet located at the floor level supplying a vertical upward inflow. Three different locations of the inlet diffuser are considered. For overhead air distribution, the inlet is located on the ceiling with slower and cooler inflow. Three inlet angles are considered. For both systems, the air return location is on the ceiling at the same place. Distributions of velocity, temperature, relative humidity, and contaminant concentration in various cases for both systems are computed. Thermal comfort factors are assessed for the two systems. The results are compared among cases of each system, as well as between two typical cases of the two systems and to experimental data for an actual office building given in literature. The results provide a detailed understanding of air transport and its consequence on thermal comfort and indoor air quality that are useful for office building air conditioner design. It is found that underfloor system gives better performance than overhead system in contaminant removal and significantly in energy saving while maintaining the same thermal comfort condition.  相似文献   

6.
We analyzed 1994 sick leave for 3,720 hourly employees of a large Massachusetts manufacturer, in 40 buildings with 115 independently ventilated work areas. Corporate records identified building characteristics and IEQ complaints. We rated ventilation as moderate (approximately 25 cfm/person, 12 ls-1) or high (approximately 50 cfm/person, 24 ls-1) outdoor air supply based on knowledge of ventilation systems and CO2 measurements on a subset of work areas, and used Poisson regression to analyze sick leave controlled for age, gender, seniority, hours of non-illness absence, shift, ethnicity, crowding, and type of job (office, technical, or manufacturing worker). We found consistent associations of increased sick leave with lower levels of outdoor air supply and IEQ complaints. Among office workers, the relative risk for short-term sick leave was 1.53 (95% confidence 1.22-1.92) with lower ventilation, and 1.52 (1.18-1.97) in areas with IEQ complaints. The effect of ventilation was independent of IEQ complaints and among those exposed to lower outdoor air supply rates the attributable risk of short-term sick leave was 35%. The cost of sick leave attributable to ventilation at current recommended rates was estimated as $480 per employee per year at Polaroid. These findings suggest that net savings of $400 per employee per year may be obtained with increased ventilation. Thus, currently recommended levels of outdoor air supply may be associated with significant morbidity, and lost productivity on a national scale could be as much as $22.8 billion per year. Additional studies of IEQ impacts on productivity and sick leave, and the mechanisms underlying the apparent association are needed.  相似文献   

7.
《Building and Environment》2002,37(3):241-255
The primary functions of mechanical ventilation systems include the delivery of outdoor air to the occupants, the removal of indoor contaminants and the maintenance of thermal comfort conditions in the occupied zones. Air exchange effectiveness can be employed to characterise the ventilation air mixing within a room. This paper presents our findings pertaining to air exchange effectiveness values in a seven-storey office building. Tracer gas analysis, based on concentration decay method, is employed to determine these values. The results indicate air flow patterns in the occupied zones which approximate “perfect mixing”. The measured concentration levels of indoor air pollutants are also found to be within reasonable limits.  相似文献   

8.
Lam KS  Chan FS  Fung WY  Lui BS  Lau LW 《Indoor air》2006,16(2):86-97
A study was carried out to investigate the feasibility of achieving ultra low respirable suspended particulates (RSP) in commercial offices without major modification of existing ventilation systems by enhancing the particulates removal efficiency of existing central ventilation systems. Four types of filters which include pre-filters, cartridge filters, bag filters and high efficiency particulates air (HEPA) filters were tested in a commercial building in Causeway Bay. The results show that an RSP objective of <20 microg/m3 could be met by removing RSP from both the return air and outdoor air supply simultaneously. This level of performance is classed as 'excellent' by the Hong Kong Government, Environmental Protection Department. Filters with efficiency that exceed 80% placed both in the return air and outdoor air were sufficient to meet the objective. It is not necessary to install HEPA filters to achieve the 'excellent' class. The outdoor air filter has great influence on the steady state indoor RSP concentration while the effective cleaning rate is governed by the return air filter. Higher efficiency filters increased the static drop but the volume flow of the air fan was not affected significantly. The additional cost incurred was <5% of the existing operation cost. PRACTICAL IMPLICATIONS: This paper reports a field study of RSP control for an indoor office environment. The results are directly applicable to building service engineering in the design of ventilation systems using air-handling units. Field observations indicated that indoor RSP in an office environment could be suppressed below 20 microg/m3 within 1 h by the simultaneous filtration of outdoor air and return air. Outdoor air filtration has a great influence on the steady state indoor concentration and return air filtration governs the cleaning rate. It is believed that the results of this study could be extended to the cleaning of other indoor pollutants such as volatile organic compounds.  相似文献   

9.
This paper presents a case to investigate the effect of partitions in an office on the performance of under floor air supply ventilation system via computational fluid dynamics. The assessment is in terms of thermal comfort and indoor air quality with the use of a validated computer model. The results indicate that the partitions may significantly affect airflow and performance of a under floor air supply ventilation system. In particular, the presence of a gap above the partition wall is able to improve air distribution owing to less air re-circulation in the upper zone. Its effect on thermal comfort and indoor air quality indicators are evaluated.  相似文献   

10.
Dimensioning of dilution ventilation is often made using the perfect mixing approximation, assuming uniform contaminant concentration throughout the room space. However, the contaminant removal efficiency and effectiveness of air conditioning system should be accounted for during design. The effectiveness is in this context used as a measure of the contaminant distribution uniformity within the occupied zone. Influence of an occupied zone obstruction level, air distribution method, air change rate, cooling load and contaminant source non-uniformity on the contaminant removal efficiency and occupied zone contaminant concentration uniformity were studied in scale model. The room air distribution method results in contaminant concentration non-uniformity inside the occupied zone. A method was developed to take this into account during the design of air distribution system. Contaminant supply non-uniformity was found to have great influence on the concentration non-uniformity with two tested air distribution methods.  相似文献   

11.
He G  Yang X  Srebric J 《Indoor air》2005,15(5):367-380
This paper presents the experimental and numerical modeling of contaminant dispersion in a full-scale environmental chamber with different room air distribution systems. For the experimental modeling, an area source with uniform emissions of a hypothetical contaminant (SF6) from the entire floor surface is designed and constructed. Two different types of ventilation are studied: displacement and mixing ventilation. A computer model for predicting the contaminant dispersion in indoor spaces was validated with experimental data. The validated model is used to study the effects of airflow and the area-source location on contaminant dispersion. Results show that the global airflow pattern has a strong impact on the distribution of the contaminants. In general, the personal exposure could be estimated by analyzing the relative source positions in the airflow pattern. Accordingly, the location of an exhaust diffuser may not greatly affect the airflow pattern, but can significantly affect the exposure level in the room. PRACTICAL IMPLICATIONS: When designing ventilation in addition to bringing fresh air to occupants, it is important to consider the removal of contaminants released in the off-gassing of building materials. Typical indoor off-gassing examples are emissions of volatile organic compounds from building enclosure surfaces such as flooring and painted walls. In this study, we conducted experimental and numerical modeling of different area sources in a mock-up office setup, with displacement or mixing ventilation. Displacement ventilation was as successful as mixing ventilation in removing the contaminant source from the floor area. Actually, the most important consideration in the removal of these contaminants is the relative position of the area source to the main airflow pattern and the occupied zone.  相似文献   

12.
Mai HK  Chan DW  Burnett J 《Indoor air》2003,13(3):311-312
In a typical air-conditioned office, the thermal comfort and indoor air quality are sustained by delivering the amount of supply air with the correct proportion of outdoor air to the breathing zone. However, in a real office, it is not easy to measure these airflow rates supplied to space, especially when the space is served by a variable air volume (VAV) system. The most accurate method depends on what is being measured, the details of the building and types of ventilation system. The constant concentration tracer gas method as a means to determine ventilation system performance, however, this method becomes more complicated when the air, including the tracer gas is allowed to recirculate. An accurate measurement requires significant resource support in terms of instrumentation set up and also professional interpretation. This method deters regular monitoring of the performance of an airside systems by building managers, and hence the indoor environmental quality, in terms of thermal comfort and indoor air quality, may never be satisfactory. This paper proposes a space zone model for the calculation of all the airflow parameters based on tracer gas measurements, including flow rates of outdoor air, VAV supply, return space, return and exfiltration. Sulphur hexafluoride (SF6) and carbon dioxide (CO2) are used as tracer gases. After using both SF6 and CO2, the corresponding results provide a reference to justify the acceptability of using CO2 as the tracer gas. The validity of using CO2 has the significance that metabolic carbon dioxide can be used as a means to evaluate real time airflow rates. This approach provides a practical protocol for building managers to evaluate the performance of airside systems.  相似文献   

13.
The effects of air filtration and ventilation on indoor particles were investigated using a single-zone mathematical model. Particle concentration indoors was predicted for several I/O conditions representing scenarios likely to occur in naturally and mechanically ventilated buildings. The effects were studied for static and dynamic conditions in a hypothetical office building. The input parameters were based on real-world data. For conditions with high particle concentrations outdoors, it is recommended to reduce the amount of outdoor air delivered indoors and the necessary reduction level can be quantified by the model simulation. Consideration should also be given to the thermal comfort and minimum outdoor air required for occupants. For conditions dominated by an indoor source, it is recommended to increase the amount of outdoor air delivered indoors and to reduce the amount of return air. Air filtration and ventilation reduce particle concentrations indoors, with the overall effect depending on efficiency, location and the number of filters applied. The assessment of indoor air quality for specific conditions could be easily calculated by the model using user-defined input parameters.  相似文献   

14.
Scientific literature on the effects of ventilation on health, comfort, and productivity in non-industrial indoor environments (offices, schools, homes, etc.) has been reviewed by a multidisciplinary group of European scientists, called EUROVEN, with expertise in medicine, epidemiology, toxicology, and engineering. The group reviewed 105 papers published in peer-reviewed scientific journals and judged 30 as conclusive, providing sufficient information on ventilation, health effects, data processing, and reporting, 14 as providing relevant background information on the issue, 43 as relevant but non-informative or inconclusive, and 18 as irrelevant for the issue discussed. Based on the data in papers judged conclusive, the group agreed that ventilation is strongly associated with comfort (perceived air quality) and health [Sick Building Syndrome (SBS) symptoms, inflammation, infections, asthma, allergy, short-term sick leave], and that an association between ventilation and productivity (performance of office work) is indicated. The group also concluded that increasing outdoor air supply rates in non-industrial environments improves perceived air quality; that outdoor air supply rates below 25 l/s per person increase the risk of SBS symptoms, increase short-term sick leave, and decrease productivity among occupants of office buildings; and that ventilation rates above 0.5 air changes per hour (h-1) in homes reduce infestation of house dust mites in Nordic countries. The group concluded additionally that the literature indicates that in buildings with air-conditioning systems there may be an increased risk of SBS symptoms compared with naturally or mechanically ventilated buildings, and that improper maintenance, design, and functioning of air-conditioning systems contributes to increased prevalence of SBS symptoms.  相似文献   

15.
F. Kalmár 《Indoor air》2015,25(3):297-306
At the University of Debrecen, a new method and equipment for personalized ventilation has been developed. This equipment makes it possible to change the airflow direction during operation with a time frequency chosen by the user. The developed office desk with integrated air ducts and control system permits ventilation with 100% outdoor air, 100% recirculated air, or a mix of outdoor and recirculated air in a relative proportion set by the user. It was shown that better comfort can be assured in hot environments if the fresh airflow direction is variable. Analyzing the time step of airflow direction changing, it was found that women prefer smaller time steps and their votes related to thermal comfort sensation are higher than men's votes.  相似文献   

16.
The importance of the intake positioning height above the floor level on the performance of “ductless” personalized ventilation (“ductless” PV) in conjunction with displacement ventilation (DV) was examined with regard to the quality of inhaled air and of the thermal comfort provided. A typical office room with two workstations positioned one behind the other was arranged in a full-scale room. Each workstation consisted of a table with an installed “ductless” PV system, PC, desk lamp and seated breathing thermal manikin. The “ductless” PV system sucked the clean and cool displacement air supplied over the floor at four different heights, i.e. 2, 5, 10 and 20 cm and transported it direct to the breathing level. Moreover, two displacement airflow rates were used with a supply temperature adjusted in order to maintain an exhaust air temperature of 26 °C. Two pollution sources, namely air exhaled by one of the manikins and passive pollution on the table in front of the same manikin were simulated by constant dosing of tracer gases. The results show that the positioning of a “ductless” PV intake height up to 0.2 m above the floor will not significantly influence the quality of inhaled air and thermal comfort.  相似文献   

17.
采用CFD的方法对不同通风方式的典型的办公室内污染物的去除进行了模拟,介绍并比较了换气效率和通风效率作为有效的室内空气品质参数在通风设计和实地测量中的应用:总共进行了3个不同的数值模拟计算,总结实验结果得出:在不知道室内污染源时,采用换气效率比较评价室内通风设计方案;而对于已知室内污染源及释放率的情况,采用通风效率作为评价标准将更准确,以便能详细地给出污染物排除情况。基于本文的研究,空调系统设计者可以根据特定的情况选择适当的参数来指导空调通风系统的设计。  相似文献   

18.
影响通风房间浓度因素的分析   总被引:2,自引:0,他引:2  
涂光备  李景广 《暖通空调》2002,32(3):103-105
根据房间通风效率,计算了常见的混合式通风系统的污染物稳定浓度,定量分析了影响稳定浓度的因素,如通风效率、预处理设备的效率、回风率等。认为就给定系统而言,提高通风效率特别是相对效率、提高送风量、设置空气预处理设备是降低室内污染物浓度、降低新风量的有效措施。  相似文献   

19.
Mechanical ventalation system performance involves the provision of adequate amuunts of outdoor air, uniform distribution of ventilation air within the occupied space, and the maintenance of thermal comfort. Standard measurement techniques exist to evaluate thermal comfort and air change rates in mechanically ventilated buildings; procedures to evaluate air distribution or ventilation effectiveness in the field are still being developed. This paper presents measuremetlts of air change rates and ventilation effectivenes in an office/library building in Washington, DC. The tracer gas decay technique was used to measure whole building air change rates. The air change rates during the measurement period were essentially constant at about 0.8 air changes per hour, somewhat below the design specification and above the minimum recmmmded in ASHRAE Standard 62-1989. Ventilation effectiveness was investigated at several locations within the building through the measurement of local tracer gas decay rate and mean local age of air. The ventilation effectiveness measurements serve as an investigation of the applicability of the m e a s u r r n procedures employed, providing insight into the measurement issue of establishing initial conditions, the spatial variation in test results within a building, and the repeatabildy between tests. The results of the ventilation effectiveness meusurements are consistent with good distrhtion of the outdoor air by the ventilation system and good mixing within the occupied space.  相似文献   

20.
A liquid desiccant based dedicated outdoor air-chilled ceiling (DOAS-CC) system is proposed to serve a multi-zone space. The outdoor airflow rate and the supply air humidity ratio are two crucial variables in such a system, which significantly influence indoor thermal comfort, indoor air quality and energy consumption. Two strategies are presented to optimize these two variables in the study. They are the demand-controlled ventilation (DCV) strategy and the supply air humidity ratio set-point reset strategy. To evaluate the performances of these two strategies, a basic control strategy, i.e., the strategy adopting constant ventilation flow rate and constant supply air humidity ratio, is selected as the benchmark. Performances of the two strategies in terms of indoor air temperature, relative humidity and CO2 concentration as well as energy consumption are analyzed using simulation tests. The results show that the supply air humidity ratio set-point reset strategy is effective for the indoor air humidity control. It can save about 19.4% of total energy consumption during the whole year. The DCV-based ventilation strategy can further reduce about 10.0% of energy consumption.  相似文献   