The purpose of this investigation is to improve the study of the characteristics of noncollinear acoustooptic tunable filters (AOTFs) used in imaging spectroscopy. Three filters were characterized and the results compared with tuning models to verify that device operation can be reliably predicted in advance. All these devices use tellurium dioxide as the interaction medium and have large geometric apertures for spectroscopic imaging applications in the spectral range 0.5-3.5 microm. The device characteristics that we studied were compared with the results of AOTF models, and the spectral and angular dependence of acoustic frequency and bandpass width for both output polarization states were confirmed by measurements. One of the AOTFs was used as a dispersive element coupled to external imaging optics. We summarize measurements of the basic spectral and imaging characteristics in this configuration.  相似文献   

2.
This article presents analysis and optimization of a microfluidic particle filter that uses acoustic radiation forces to remove particles larger than a selected size by adjusting the driving conditions of the piezoelectric transducer (PZT). Operationally, the acoustic filter concentrates microparticles to the center of the microchannel, minimizing undesirable particle adsorption to the microchannel walls. Finite element models predict the complex two-dimensional acoustic radiation force field perpendicular to the flow direction in microfluidic devices. We compare these results with experimental parametric studies including variations of the PZT driving frequencies and voltages as well as various particle sizes (0.5-5.0 microm in diameter). These results provide insight into the optimal operating conditions and show the efficacy of our device as a filter with an adjustable effective pore size. We demonstrate the separation of Saccharomyces cerevisiae from MS2 bacteriophage using our acoustic device. With optimized design of our microfluidic flow system, we achieved yields of greater than 90% for the MS2 with greater than 80% removal of the S. cerevisiae in this continuous-flow sample preparation device.  相似文献   

3.
We describe the design, construction, and operation of a hyperspectral microarray scanner for functional genomic research. The hyperspectral instrument operates with spatial resolutions ranging from 3 to 30 microm and records the emission spectrum between 490 and 900 nm with a spectral resolution of 3 nm for each pixel of the microarray. This spectral information, when coupled with multivariate data analysis techniques, allows for identification and elimination of unwanted artifacts and greatly improves the accuracy of microarray experiments. Microarray results presented in this study clearly demonstrate the separation of fluorescent label emission from the spectrally overlapping emission due to the underlying glass substrate. We also demonstrate separation of the emission due to green fluorescent protein expressed by yeast cells from the spectrally overlapping autofluorescence of the yeast cells and the growth media.  相似文献   

4.
Novel high-throughput sample preparation strategies for MALDI imaging mass spectrometry (IMS) and profiling are presented. An acoustic reagent multispotter was developed to provide improved reproducibility for depositing matrix onto a sample surface, for example, such as a tissue section. The unique design of the acoustic droplet ejector and its optimization for depositing matrix solution are discussed. Since it does not contain a capillary or nozzle for fluid ejection, issues with clogging of these orifices are avoided. Automated matrix deposition provides better control of conditions affecting protein extraction and matrix crystallization with the ability to deposit matrix accurately onto small surface features. For tissue sections, matrix spots of 180-200 microm in diameter were obtained and a procedure is described for generating coordinate files readable by a mass spectrometer to permit automated profile acquisition. Mass spectral quality and reproducibility was found to be better than that obtained with manual pipet spotting. The instrument can also deposit matrix spots in a dense array pattern so that, after analysis in a mass spectrometer, two-dimensional ion images may be constructed. Example ion images from a mouse brain are presented.  相似文献   

5.
The design and performance of guided shear horizontal surface acoustic wave (guided SH-SAW) devices on LiTaO3 substrates are investigated for high-sensitivity chemical and biochemical sensors in liquids. Despite their structural similarity to Rayleigh SAW, SH-SAWs often propagate slightly deeper within the substrate, hence preventing the implementation of high-sensitivity detectors. The device sensitivity to mass and viscoelastic loading is increased using a thin guiding layer on the device surface. Because of their relatively low shear wave velocity, various polymers including poly(methyl methacrylate) (PMMA) and cyanoethyl cellulose (cured or cross-linked) are investigated as the guiding layers to trap the acoustic energy near the sensing surface. The devices have been tested in biosensing and chemical sensing experiments. Suitable design principles for these applications are discussed with regard to wave guidance, electrical passivation of the interdigital transducers from the liquid environments, acoustic loss, and sensor signal distortion. In biosensing experiments, using near-optimal PMMA thickness of approximately 2 microm, mass sensitivity greater than 1500 Hz/(ng/mm2) is demonstrated, resulting in a minimum detection limit less than 20 pg/mm2. For chemical sensor experiments, it is found that optimal waveguide thickness must be modified to account for the chemically sensitive layer which also acts to guide the SH-SAW. A detection limit of 780 (3 x peak-to-peak noise) or 180 ppb (3 x rms noise) is estimated from the present measurements for some organic compounds in water.  相似文献   

6.
High-resolution clinical systems operating near 15 MHz are becoming more available; however, they lack sensitive harmonic imaging modes for ultrasound contrast agent (UCA) detection, primarily due to limited bandwidth. When an UCA is driven to nonlinear oscillation, a very wideband acoustic transient response is produced that extends beyond 15 MHz. We propose a novel strategy using two separate transducers at widely separated frequencies and arranged confocally to simultaneously excite and receive acoustic transients from UCAs. Experiments were performed to demonstrate that this new mode shows similar resolution, higher echo amplitudes, and greatly reduced attenuation compared to transmission at a higher frequency, and superior resolution compared to transmission and reception at a lower frequency. The proposed method is shown to resolve two 200 microm tubes with centers separated by 400 microm. Strong acoustic transients were detected for rarefaction-first 1-cycle pulses with peak-negative pressures above 300 kPa. The results of this work may lead to uses in flow and/or targeted imaging in applications requiring very high sensitivity to contrast agents.  相似文献   

7.
The first demonstration, to the best of our knowledge, of continuous-wave (cw) difference-frequency generation (DFG) in LiInS2 crystal is reported. Wide spectral coverage (5.5-11.3 microm) has been obtained with angle and wavelength tuning for type II (eoe) critically phase-matched parametric interaction. The phase-matching conditions in cw DFG have been investigated, which allowed us to improve the Sellmeier parameters by use of a two-pole dispersion equation. An effective nonlinear coefficient deff = 6.9 +/- 0.8 pm/V has been determined at approximately 7 microm relative to the well-known nonlinear coefficient d36 of AgGaS2, which yields a power-conversion efficiency of approximately 12.4 microW/(W2 cm). We evaluated the high-resolution spectral characteristics of the DFG source by recording C2H2 and SO2 spectra.  相似文献   

8.
Hanssen L 《Applied optics》2001,40(19):3196-3204
An integrating-sphere system has been designed and constructed for multiple optical properties measurement in the IR spectral range. In particular, for specular samples, the absolute transmittance and reflectance can be measured directly with high accuracy and the absorptance can be obtained from these by simple calculation. These properties are measured with a Fourier transform spectrophotometer for several samples of both opaque and transmitting materials. The expanded uncertainties of the measurements are shown to be less than 0.003 (absolute) over most of the detector-limited working spectral range of 2 to 18 microm. The sphere is manipulated by means of two rotation stages that enable the ports on the sphere to be rearranged in any orientation relative to the input beam. Although the sphere system is used for infrared spectral measurements, the measurement method, design principles, and features are generally applicable to other wavelengths as well.  相似文献   

9.
We use an alternating phase-shifting mask design method (APSMDM) to design and fabricate a specially designed surface acoustic wave (SAW) filter mold that has a linewidth pattern of only 5 microm (not small). A basic SAW filter mold [having a general interdigital transducer (IDT) pattern] also is fabricated for comparison. A near-field phase shift lithographic (NFPSL) process is applied in the fabrication of the narrow gap SAW devices, during which process the narrow gaps and short optical distance (SOD) electrodes are derived. We note that, in this way, important features (such as floating electrodes, high-metallization ratio, and a narrow gap structure) for enhancing the performance of high-efficiency SAW devices can be produced simultaneously. In addition, the other half of the special IDT pattern strips can be derived by using this APSMDM. This causes a decrease in the periodicity of the IDT pattern and, therefore, a decrease in the acoustic wavelength, in turn leading to an increase in the deltaf (deltaf is the difference in frequency between the harmonic and its adjacent harmonic) and a decrease in the insertion loss. A 2.75 GHz SAW filter is fabricated using the APSMDM with a mold with only 5-microm wide linewidth fingers.  相似文献   

10.
Sato M  Wakaki I  Watanabe Y  Tanno N 《Applied optics》2005,44(13):2471-2481
We describe the fundamental characteristics of a synthesized light source (SLS) consisting of two low-coherence light sources to enhance the spatial resolution for optical coherence tomography (OCT). The axial resolution of OCT is given by half the coherence length of the light source. We fabricated a SLS with a coherence length of 2.3 microm and a side-lobe intensity of 45% with an intensity ratio of LED1:LED2 = 1:0.5 by combining two light sources, LED1, with a central wavelength of 691 nm and a spectral bandwidth of 99 nm, and LED2, with a central wavelength of 882 nm and a spectral bandwidth of 76 nm. The coherence length of 2.3 microm was 56% of the shorter coherence length in the two LEDs, which indicates that the axial resolution is 1.2 microm. The lateral resolution was measured at less than 4.4 microm by use of the phase-shift method and with a test pattern as a sample. The measured rough surfaces of a coin are illustrated and discussed.  相似文献   

11.
We investigated the size-dependent electrical conductivities of indium zinc oxide stripes with different widths from 50 nm to 4 microm and with the same thickness of 50 nm deposited by RF magnetron sputtering. The size of the indium zinc oxide stripes was controlled by e-beam lithography. The distance of the two Ti/Au Ohmic electrodes along the indium zinc oxide stripes was kept constant at 25 microm. The electrical conductivity decreased as the size of the indium zinc oxide stripes decreased below a critical width (80 nm). The activation energy, derived from the electric conductivity versus temperature measurement, was dependent on the dimensions of indium zinc oxide stripes. These results can be understood as stemming from surface charge trapping from the absorption of oxygen and/or water vapor, which leads to an increase in the energy difference between the conduction energy band and the Fermi energy.  相似文献   

12.
The electrical reflection coefficient r(e) and velocity shift (Deltanu/nu)(e) for grooves has never been formulated. All previous calculations for r(e) and (Deltanu/nu)(e) have used formulas valid for the reflection of a surface acoustic wave (SAW) from an array of conducting strips. However, the discontinuity in electrical boundary conditions leading to these formulas does not exist in groove gratings. A new expression for the electrical reflection coefficient and velocity shift for some material overlays is derived from both the variational principle and perturbation theory. The results for various substrates are compared to show the agreement between the two approaches. The implications of this new formulation for the design of grooved arrays on various materials are discussed, effectively resolving the discrepancy between theory and experiment.  相似文献   

13.
We are developing kilopixel arrays of TES microcalorimeters to enable high-resolution x-ray imaging spectrometers for future x-ray observatories and laboratory astrophysics experiments. Our current array design was targeted as a prototype for the X-ray Microcalorimeter Spectrometer proposed for the International X-ray Observatory, which calls for a 40×40-pixel core array of 300?μm devices with 2.5?eV energy resolution (at 6?keV). Here we present device characterization of our 32×32 arrays, including x-ray spectral performance of individual pixels within the array. We present our results in light of the understanding that our Mo/Au TESs act as weak superconducting links, causing the TES critical current (I c ) and transition shape to oscillate with applied magnetic field (B). We show I c (B) measurements and discuss the uniformity of these measurements across the array, as well as implications regarding the uniformity of device noise and response. In addition, we are working to reduce pixel-to-pixel electrical and thermal crosstalk; we present recent test results from an array that has microstrip wiring and an angle-evaporated copper backside heatsinking layer, which provides copper coverage on the four sidewalls of the silicon wells beneath each pixel.  相似文献   

14.
We have developed an optical delivery device (catheter) capable of transmitting broadband infrared light (IR wavelengths from 2 to 10 microm) for both diagnostic and therapeutic applications. The catheter is 1.68 mm in outer diameter and 1 m in length. It consists of two hollow glass waveguides coupled to a high-refractive-index optic tip. The IR light interacts with the tissue at the optic-tissue interface to measure the spectral signatures and perform therapy on the tissue at this interface. Fourier-transform IR spectrophotometer light is used to obtain the spectral signatures, and an IR free-electron laser (FEL) is used to study the therapeutic interaction of evanescent waves with the tissue. We present our catheter design; preliminary IR spectroscopy of aorta, blood, fatty tissue, and muscle; and IR FEL therapy on atheroslerotic aorta.  相似文献   

15.
Biological cells are complex objects that have the potential to act as templates for the subsequent construction of nanoscale structures. We demonstrate the ability to controllably and reversibly manipulate individual, live bacterial cells across micron-sized electrical gaps, and to detect bridging directly through changes in the electrical response. Our model system, Bacillus mycoides, is a rod-shaped bacterium approximately 800 nm wide and 5 microm long, similar in size and shape to many inorganic nanowires.  相似文献   

16.
Previous studies dealing with contrast agent microbubbles have demonstrated that ultrasound (US) can significantly influence the movement of microbubbles. In this paper, we investigated the influence of the acoustic radiation force on individual air bubbles using high-speed photography. We emphasize the effects of the US parameters (pulse length, acoustic pressure) on different bubble patterns and their consequences on the translational motion of the bubbles. A stream of uniform air bubbles with diameter ranging from 35 microm to 79 microm was generated and insonified with a single US pulse emitted at a frequency of 130 kHz. The bubble sizes have been chosen to be above, below, and at resonance. The peak acoustic pressures used in these experiments ranged from 40 kPa to 120 kPa. The axial displacements of the bubbles produced by the action of the US pulse were optically recorded using a high-speed camera at 1 kHz frame rate. The experimental results were compared to a simplified force balance theoretical model, including the action of the primary radiation force and the fluid drag force. Although the model is quite simple and does not take into account phenomena like bubble shape oscillations and added mass, the experimental findings agree with the predictions. The measured axial displacement increases quasilinearly with the burst length and the transmitted acoustic pressure. The axial displacement varies with the size and the density of the air bubbles, reaching a maximum at the resonance size of 48 microm. The predicted displacement values differ by 15% from the measured data, except for resonant bubbles for which the displacement was overestimated by about 40%. This study demonstrates that even a single US pulse produces radiation forces that are strong enough to affect the bubble position.  相似文献   

17.
Techniques for manipulating, separating, and trapping particles and cells are highly desired in today's bioanalytical and biomedical field. The microfluidic chip-based acoustic noncontact trapping method earlier developed within the group now provides a flexible platform for performing cell- and particle-based assays in continuous flow microsystems. An acoustic standing wave is generated in etched glass channels (600x61 microm2) by miniature ultrasonic transducers (550x550x200 microm3). Particles or cells passing the transducer will be retained and levitated in the center of the channel without any contact with the channel walls. The maximum trapping force was calculated to be 430+/-135 pN by measuring the drag force exerted on a single particle levitated in the standing wave. The temperature increase in the channel was characterized by fluorescence measurements using rhodamine B, and levels of moderate temperature increase were noted. Neural stem cells were acoustically trapped and shown to be viable after 15 min. Further evidence of the mild cell handling conditions was demonstrated as yeast cells were successfully cultured for 6 h in the acoustic trap while being perfused by the cell medium at a flowrate of 1 microL/min. The acoustic microchip method facilitates trapping of single cells as well as larger cell clusters. The noncontact mode of cell handling is especially important when studies on nonadherent cells are performed, e.g., stem cells, yeast cells, or blood cells, as mechanical stress and surface interaction are minimized. The demonstrated acoustic trapping of cells and particles enables cell- or particle-based bioassays to be performed in a continuous flow format.  相似文献   

18.
Metamaterials are composite materials whose material properties(acoustic, electrical, magnetic, or optical, etc.) are determined by their constitutive structural materials, especially the unit cells. The development of metamaterials continues to redefine the boundaries of materials science. In the field of electromagnetic research and beyond, these materials offer excellent design flexibility with their customized properties and their tunability under external stimuli. In this paper, we first provide a literature review of metamaterials with a focus on the technology and its evolution. We then discuss steps in the industrialization process and share our own experience.  相似文献   

19.
Domain-engineered pyroelectric radiometer   总被引:2,自引:0,他引:2  
Lehman J  Eppeldauer G  Aust JA  Racz M 《Applied optics》1999,38(34):7047-7055
We built a large-area domain-engineered pyroelectric radiometer with high spatial and spectral response uniformity that is an excellent primary transfer standard for measurements in the near- and the mid-infrared wavelength regions. The domain engineering consisted of inverting the spontaneous polarization over a 10-mm-diameter area in the center of a uniformly poled, 15.5 mm x 15.5 mm square, 0.25-mm-thick LiNbO(3) plate. Gold black was used as the optical absorber on the detector surface, and an aperture was added to define the optically sensitive detector area. Our results indicate that we significantly reduced the acoustic sensitivity without loss of optical sensitivity. The detector noise equivalent power was not exceptionally low but was nearly constant for different acoustic backgrounds. In addition, the detector's spatial-response uniformity variation was less than 0.1% across the 7.5-mm-diameter aperture, and reflectance measurements indicated that the gold-black coating was spectrally uniform within 2%, from 800 to 1800 nm. Other detailed evaluations of the detector include detector responsivity as a function of temperature, electrical frequency response, angular response, and field of view.  相似文献   

20.
Zhang E  Laufer J  Beard P 《Applied optics》2008,47(4):561-577
A multiwavelength backward-mode planar photoacoustic scanner for 3D imaging of soft tissues to depths of several millimeters with a spatial resolution in the tens to hundreds of micrometers range is described. The system comprises a tunable optical parametric oscillator laser system that provides nanosecond laser pulses between 600 and 1200 nm for generating the photoacoustic signals and an optical ultrasound mapping system based upon a Fabry-Perot polymer film sensor for detecting them. The system enables photoacoustic signals to be mapped in 2D over a 50 mm diameter aperture in steps of 10 microm with an optically defined element size of 64 microm. Two sensors were used, one with a 22 microm thick polymer film spacer and the other with a 38 mum thick spacer providing -3 dB acoustic bandwidths of 39 and 22 MHz, respectively. The measured noise equivalent pressure of the 38 microm sensor was 0.21 kPa over a 20 MHz measurement bandwidth. The instrument line-spread function (LSF) was measured as a function of position and the minimum lateral and vertical LSFs found to be 38 and 15 microm, respectively. To demonstrate the ability of the system to provide high-resolution 3D images, a range of absorbing objects were imaged. Among these was a blood vessel phantom that comprised a network of blood filled tubes of diameters ranging from 62 to 300 microm immersed in an optically scattering liquid. In addition, to demonstrate the applicability of the system to spectroscopic imaging, a phantom comprising tubes filled with dyes of different spectral characteristics was imaged at a range of wavelengths. It is considered that this type of instrument may provide a practicable alternative to piezoelectric-based photoacoustic systems for high-resolution structural and functional imaging of the skin microvasculature and other superficial structures.  相似文献   