共查询到20条相似文献,搜索用时 15 毫秒
1.
Sam AK Sirelkhatim DA Hassona RK Hassan RE Hag Musa E Ahmed MM 《Radiation protection dosimetry》2002,102(2):169-174
This study was conducted at the request of authorities in western Darfour State, to address the public concern about the levels of radioactivity in the area of Jebel Mun situated at Sudan-Chad international boundaries. It has been identified as a high background radiation area through aerial geological surveys conducted in late 1970s. The ambient gamma dose in the area was measured with the aid of a hand-held dose rate meter (Mini-Rad, Series 1000) and the surface rock samples were collected and analysed for their radioactivity content using a high-resolution gamma spectrometry equipped with HPGe with relative efficiency of 18%. The activity concentrations of 238U, 232Th and 40K were found to range from 39-253 Bq.kg(-1), 41-527 Bq.kg(-1) and 77-3027 Bq.kg(-1), respectively. From the values of the standard deviation it was concluded that the activity concentration of the considered primordial radionuclides was highly scattered (localised) which in turn indicates non-uniformity in the geological features and/or formations. 238U activity concentration corresponds to equivalent mass concentration of 7.77+/-6.12 ppm (3.19-20.73 ppm), which is of no economic importance. Samples are enriched in thorium relative to uranium as reflected by the Th:U mass ratio which ranges from 3 to 17. The absorbed dose rate in air as estimated from the measured activity concentrations of the primordial radionuclides using the DRCFs (dose rate conversion factors) falls within the range of 70-522 nGy.h(-1) with an average of 221+/-130 nGy.h(-1). It corresponds to an annual effective dose equivalent averaged of 0.27 mSv. The regression analysis has shown that the correlation between calculated and the measured ambient dose rate is marginally significant (r2 = 0.59). The 232Th series is the major producer of the surface radioactivity followed by 40K as they contribute 48% and 32% of the total absorbed dose, respectively. 相似文献
2.
3.
The medical radioisotope (201)Tl is produced by a cyclotron through the (203)Tl(p, 3n)(201)Pb reaction in the nuclear medicine research group of Agricultural, Medical and Industrial Research Schools in Iran. The produced (201)Pb decays to (201)Tl by electron capture. One of the most important problems that may occur is malfunction of a part of target or beam line, so that it needs the bombardment to be stopped and the problem fixed. In this work, induced radioactivity of the target, aluminium case of target, beam line and concrete walls of the thallium target room were calculated by Monte Carlo method. Then by using the results of the Monte Carlo simulation, the whole body absorbed dose to cyclotron personnel during repair and after stopping the bombardment, were assessed at different places of target room. 相似文献
4.
Wambersie A Menzel HG Gahbauer RA Jones DT Michael BD Paretzke H 《Radiation protection dosimetry》2002,99(1-4):445-452
Absorbed dose is a quantity which is scientifically rigorously defined and used to quantify the exposure of biological objects, including humans, to ionising radiation. There is, however, no unique relationship between absorbed dose and induced biological effects. The effects induced by a given absorbed dose to a given biological object depend also on radiation quality and temporal distribution of the irradiation. In radiation therapy, empirical approaches are still used today to account for these dependencies in practice. In hadron therapy (neutrons, protons, ions), radiation quality is accounted for with a diversity of (almost hospital specific) methods. The necessity to account for temporal aspects is well known in external beam therapy and in high dose rate brachytherapy. The paper reviews the approaches for weighting the absorbed dose in radiation therapy, and focusses on the clinical aspects of these approaches, in particular the accuracy requirements. 相似文献
5.
This study assesses the level of background radiation for Kayseri province of Turkey. Natural radionuclide activity concentrations in soil samples were determined using high-resolution gamma spectroscopy. Outdoor gamma dose measurements in air at 1 m above ground level were determined using a portable gamma scintillation detector. The obtained results of uranium and thorium series as well as potassium ((40)K) are discussed. The present data were compared with the data obtained from different areas in Turkey. From the measured gamma-ray spectra, the average activity concentrations were determined for (238)U (range from 3.91 to 794.25 Bq kg(-1)), (232)Th (range from 0.68 to 245.55 Bq kg(-1)) and (40)K (range from 23.68 to 2718.71 Bq kg(-1)). The average activity concentrations of (238)U, (232)Th and (40)K were found to be 35.51, 37.27 and 429.66 Bq kg(-1), respectively, and 11.53 Bq kg(-1) for the fission product (137)Cs. The highest values of (238)U, (232)Th and (40)K concentrations (794.25 Bq kg(-1), 245.55 Bq kg(-1), 2718.71 Bq kg(-1), respectively) were observed in abnormal samples at Hayriye village. The average outdoor gamma dose rate in air at 1 m above the ground was determined as 114.43 nGy h(-1). Using the data obtained in this study, the average annual effective dose for a person living in Kayseri was found to be about 140.34 μSv. 相似文献
6.
Wieser A 《Radiation protection dosimetry》2012,149(1):71-78
Electron paramagnetic resonance dosimetry with tooth enamel has been proved to be a reliable method to determine retrospectively exposures from photon fields with minimal detectable doses of 100 mGy or lower, which is lower than achievable with cytogenetic dose reconstruction methods. For risk assessment or validating dosimetry systems for specific radiation incidents, the relevant dose from the incident has to be calculated from the total absorbed dose in enamel by subtracting additional dose contributions from the radionuclide content in teeth, natural external background radiation and medical exposures. For calculating organ doses or evaluating dosimetry systems the absorbed dose in enamel from a radiation incident has to be converted to air kerma using dose conversion factors depending on the photon energy spectrum and geometry of the exposure scenario. This paper outlines the approach to assess individual dose contributions to absorbed dose in enamel and calculate individual air kerma of a radiation incident from the absorbed dose in tooth enamel. 相似文献
7.
8.
Ajayi OS 《Radiation protection dosimetry》2002,98(4):441-444
The average outdoor absorbed dose rate in air and the average annual effective dose equivalent due to terrestrial gamma radiation from 40K, 238U and 232Th in rocks in Ondo and Ekiti States, Southwestern Nigeria have been evaluated from measurements of the concentrations of these radionuclides in this environmental material. The concentration measurements were obtained using a very sensitive gamma spectroscopic system consisting of a 7.6 cm x 7.6 cm NaI(Tl) scintillation detector coupled to a computerised ACCUSPEC installation. The average absorbed dose rate and average annual effective dose equivalent was found to be 8.33 +/- 2.76 nGy x h(-1) and 8.7 +/- 2.9 microSv x y(-1) respectively. 相似文献
9.
针对我国用于肿瘤治疗水中吸收剂量测量的剂量计不能直接溯源到水吸收剂量,无法与国际水吸收剂量测量方法接轨的问题,该文研制60Coγ射线水中吸收剂量绝对测量装置。为配合国内肿瘤治疗的水吸收剂量测量,对现有剂量计升级,使其更便于水吸收剂量测量,并对升级9606B剂量计的重复性、非线性和电离室的能量响应进行测试。结果表明:该剂量计的重复性、非线性、电离室能量响应均好于JJG 912——2010《治疗水平电离室剂量计》和IEC 60731——2011《用于放射治疗的电离室剂量计》中对相应参数的要求。 相似文献
10.
11.
Assessment of Terrestrial Gamma Radiation in Sudan 总被引:2,自引:0,他引:2
Sam A.K.; Ahmed M.M.O.; El Khangi F.A.; El Nigumi Y.O.; Holm E. 《Radiation protection dosimetry》1997,71(2):141-145
12.
13.
14.
Schlegel DR 《Radiation protection dosimetry》2004,110(1-4):819-821
A computational method is presented that transfers the spectral neutron fluence from the measuring position to a reference point in a biological sample. The method is applied to the determination of the absorbed dose in adult blood irradiated with monoenergetic neutrons of 0.035 and 14.8 MeV. 相似文献
15.
16.
17.
18.
《Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment》1999,361(2-3):540-547
High-energy electron storage rings generate energetic bremsstrahlung photons through radiative interaction of the particle beam with the residual gas molecules and other components inside the storage ring. At synchrotron radiation facilities, where beamlines are channeled out of the storage ring, a continuous bremsstrahlung spectrum, with a maximum energy of the stored particle beam, will be present. At the advanced photon source (APS), where the stored beam energy is 7 GeV, bremsstrahlung generated in the straight sections of the insertion device beamlines, which are a total of 15.38 m in length, can be significant. The contribution from each bremsstrahlung interaction adds up to produce a narrow mono-directional bremsstrahlung beam that comes down through the insertion device beamlines. The resulting absorbed dose distributions by this radiation in a 300 mm×300 mm×300 mm tissue substitute cube phantom were measured with LiF:Mg,Ti (TLD-700) thermoluminescent dosemeters. The normalized absorbed dose, in a cross-sectional area of 100 mm2 at a depth of 150 mm of the PMMA phantom, was measured as 3.3×106 mGy h−1W−1 for 7-GeV bremsstrahlung spectrum. 相似文献
19.
20.
An early diagnosis system for breast cancer using refraction-enhanced breast tomosynthesis is under development. Tomograms of breast specimens based on refraction-contrast were demonstrated using the simplest shift-and-add tomosynthesis algorithm. Raw projection image data of breast specimens for tomosynthesis were acquired for a total of 51 views over an angle of 50°, in increments of 1°, by rotating the object. The incident X ray was monochromatic synchrotron radiation with 20 keV. The purpose of this study was to estimate the absorbed dose of a new X-ray imaging method. As breast cancer almost always arises in glandular breast tissue, the average absorbed dose in such glandular tissue should be measured to estimate the radiation risk associated with mammography. The absorbed dose of the mammary gland due to monochromatic X rays was calculated by the Monte Carlo method, and the optimal X ray energy range for refraction-enhanced breast tomosynthesis was investigated through actual measurements. Compared with the conventional method, it was found to be below one-sixth per inspection. 相似文献