共查询到20条相似文献,搜索用时 0 毫秒
1.
Results of theoretical and experimental investigations into the statistical characteristics of the voltage instability of type MN-3 measures are presented. The capabilities of linear mathematical models of the voltage instability of solid-body measures are considered and evaluated. It is shown that MN-3 type measures maintain a relative measurement (comparison) error in the range 1·10–8–3·10–8 only for a measurement period t 1 h and that with t 1 day, the error increases to values in the range 5·10–8–8·10–8, while when t 1–3 months it increases to 5·10–7. 相似文献
2.
Medvedevskikh S. V. Sobina E. P. Kremleva O. N. Medvedevskikh М. Yu. Sobina A. V. Taraeva N. S. 《Measurement Techniques》2021,64(8):633-637
Measurement Techniques - Many countries are currently focused on expanding the range of national means for measurement unit transfer characterized by established metrological traceability within... 相似文献
3.
Medvedevskikh S. V. Sobina E. P. Kremleva O. N. Medvedevskikh М. Yu. Sobina A. V. Taraeva N. S. 《Measurement Techniques》2021,64(8):638-646
Measurement Techniques - The article describes an approach to establishing the metrological traceability of reference materials adopted by TC 1.12 Reference Materials of the Euro-Asian Cooperation... 相似文献
4.
5.
6.
7.
Measurement Techniques - This is a study of the sensitivity and accuracy characteristics of three of the best known types of self-oscillating displacement transducers with flat screens which serve... 相似文献
8.
Measurement Techniques - Questions of ensuring radiation safety during irradiation of equipment in the medical, agricultural, and foodstuffs industry are discussed. Means for measuring absorbed... 相似文献
9.
The dissolution rates of mixtures of the two acids, benzoic acid and salicylic acid were determined in a phosphate buffered medium. Dissolution properties from compressed discs under sink conditions were essentially linear. Plots of dissolution rate versus compact composition deviated from the two component models for both non-interacting and interacting components. Dissolution rates, particularly for benzoic acid at intermediate weight fractions, were lower than predicted by the theory for two non-interacting components. These lower than expected rates were explained in terms of the physicochemical changes occurring in the microenvironment at the solid liquid interface. 相似文献
10.
The advantages and disadvantages are considered of an indirect method of verifying and calibrating seismic transducers. An instrument is proposed which utilizes a personal computer in order to implement the indirect method. 相似文献
11.
The possibilities are considered of the computer modeling of the metrological characteristics of a standard instrument for measuring spectral noise power density utilizing low-temperature waveguide noise generators operating in the millimeter wavelength range. 相似文献
12.
《Drug development and industrial pharmacy》2013,39(9-11):1703-1720
AbstractThe dissolution rates of mixtures of the two acids, benzoic acid and salicylic acid were determined in a phosphate buffered medium. Dissolution properties from compressed discs under sink conditions were essentially linear. Plots of dissolution rate versus compact composition deviated from the two component models for both non-interacting and interacting components. Dissolution rates, particularly for benzoic acid at intermediate weight fractions, were lower than predicted by the theory for two non-interacting components. These lower than expected rates were explained in terms of the physicochemical changes occurring in the microenvironment at the solid liquid interface. 相似文献
13.
阐述多参数监护仪心电信号、心率、血氧饱和度、无创血压、体温和呼吸速率等重要参数的计量特性,并依据多参数监护仪的实际应用及发展趋势,对JJG(闽)1038-2011多参数监护仪检定规程的不足之处提出自己的见解,对部分参数的计量性能要求和检定方法提出思路和改进建议。 相似文献
14.
15.
The importance of optimizing the design parameters of the shaping elements of the radiating surface of a multicavity model of a black body at the upper limit of the effective temperature range of the radiator is evaluated. 相似文献
16.
Measurement Techniques - We perform the analysis of the current state of measurements of complex reflection coefficient in waveguides at millimeter wavelengths. We propose an approach to the... 相似文献
17.
An approach is described in the geometrical method of calibrating vessels in which simulation is applied to examine the metrological characteristics of complicated algorithms for processing measurements. 相似文献
18.
19.
Questions of metrological provisions for contact heat flow transducers by means of which it is possible to monitor heat losses at the surface of thermal energy objects are considered. 相似文献
20.
Al'shin B. I. Bukhshtaber V. M. Karpov O. V. Krutikov V. N. 《Measurement Techniques》2001,44(6):614-617
Areas of application of solid-state voltage standards are considered, the metrological characteristics of Russian and foreign standards required and realized in practice are presented, and areas for further research are indicated. 相似文献