共查询到20条相似文献,搜索用时 15 毫秒
1.
G Chirico F Cannone S Beretta G Baldini A Diaspro 《Microscopy research and technique》2001,55(5):359-364
We have characterized a commercial confocal scanning head for the detection of single molecule fluorescence by two-photon excitation. We have verified that the distribution of the fluorescence emitted by dyes and labeled proteins on glass substrates is discrete with quanta proportional to a common reference signal. We describe and test a simple and quantitative tool to discriminate between single molecules and molecular aggregates on single snapshots based on the analysis of the intensity distribution. We have verified the square dependence of the fluorescence intensity vs. the excitation power, suggesting that no appreciable saturation and fast photo-damage of the chromophores takes place at the excitation power employed here. 相似文献
2.
The adsorption of his-tag green fluorescent protein (GFPH(6)) onto the mica surfaces has been studied by atomic force microscopy (AFM) and laser confocal fluorescence microscopy. By controlling the adsorption conditions, separated single GFPH(6) and GFPH(6) monolayer can be adsorbed and formed on mica surfaces. In present experiments, based on the AFM measurement, we found that the adsorbed GFPH(6) was bound on the mica surface with its beta-sheets. The formed GFPH(6) monolayer on mica surfaces was flat, uniform, and stable. Some applications of the formed monolayer have been demonstrated. The formed monolayer can be used as a substrate for DNA imaging and AFM mechanical lithography. 相似文献
3.
Chee Heng Hor 《仪器科学与技术》2016,44(5):558-565
The green fluorescent protein has gained interest in bioanalytical applications due to its visible fluorescence. As the usage of green fluorescent protein increases, more appropriate fluorescence instrumentation is required. Most fluorescence instrumentation uses ultraviolet light as the excitation source for the determination of green fluorescent protein. However, ultraviolet radiation may damage biological molecules and affect the quantitative analysis. In this study, the effects of the ultraviolet radiation period and the mass of green fluorescent protein on the fluorescence determination were characterized using gel imaging. The ultraviolet illumination period affected the green fluorescent protein fluorescence intensity. The fluorescence increased with the ultraviolet illumination time from 30–90 s. However, the fluorescence intensity decreased when the excitation period was longer, probably due to photobleaching. The photobleaching decreased when a higher concentration of enhanced green fluorescent protein was employed. This gel imaging study has provided a better understanding of the optimum conditions for the determination of green fluorescent protein. 相似文献
4.
Two-photon excitation fluorescence resonance energy transfer (2P-FRET) imaging microscopy can provide details of specific protein molecule interactions inside living cells. Fluorophore molecules used for 2P-FRET imaging have characteristic absorption and emission spectra that introduce spectral cross-talk (bleed-through) in the FRET signal that should be removed in the 2P-FRET images, to establish that FRET has actually occurred and to have a basis for distance estimations. These contaminations in the FRET signal can be corrected using a mathematical algorithm to extract the true FRET signal. Another approach is 2P-FRET fluorescence lifetime imaging (FLIM). This methodology allows studying the dynamic behavior of protein-protein interactions in living cells and tissues. 2P-FRET-FLIM was used to study the dimerization of the CAATT/enhancer binding protein alpha (C/EBPalpha). Results show that the reduction in donor lifetime in the presence of acceptor reveals the dimerization of the protein molecules and also determines more precisely the distance between the donor and acceptor. We describe the development and characterization of the 2P-FRET-FLIM imaging system with the Bio-Rad Radiance2100 confocal/multiphoton microscopy system. 相似文献
5.
6.
Time‐resolved microspectrofluorometry in live cells, based on time‐ and space‐correlated single‐photon counting, is a novel method to acquire spectrally resolved fluorescence decays, simultaneously in 256 wavelength channels. The system is calibrated with a full width at half maximum (FWHM) of 90 ps for the temporal resolution, a signal‐to‐noise ratio of 106, and a spectral resolution of 30 (Δλ/Λ). As an exemple, complex fluorescence dynamics of ethidium and cyan fluorescent protein (CFP) in live cells are presented. Free and DNA intercalated forms of ethidium are simultaneously distinguishable by their relative lifetime (1.7 ns and 21.6 ns) and intensity spectra (shift of 7 nm). By analysing the complicated spectrally resolved fluorescence decay of CFP, we propose a fluorescence kinetics model for its excitation/desexcitation process. Such detailed studies under the microscope and in live cells are very promising for fluorescence signal quantification. 相似文献
7.
Birkedal V Dong M Golas MM Sander B Andersen ES Gothelf KV Besenbacher F Kjems J 《Microscopy research and technique》2011,74(7):688-698
Single molecule microscopy techniques play an important role in the investigation of advanced DNA structures such as those created by the DNA origami method. Three single molecule microscopy techniques are particularly interesting for the investigation of complex self-assembled three-dimensional (3D) DNA nanostructures, namely single molecule fluorescence microscopy, atomic force microscopy (AFM), and cryogenic transmission electron microscopy (cryo-EM). Here we discuss the strengths of these three techniques and demonstrate how their interplay can yield very important and unique new insights into the structure and conformation of advanced biological nanostructures. The applications of the three single molecule microscopy techniques are illustrated by focusing on a self-assembled DNA origami 3D box nanostructure. Its size and structure were studied by AFM and cryo-EM, while the lid opening, which can be controlled by the addition of oligonucleotide keys, was recorded by F?rster/fluorescence resonance energy transfer (FRET) spectroscopy. 相似文献
8.
Kohen E Gatt S Schachtschabel A Schachtschabel DO Kohen C Agmon V Hirschberg JG Monti M 《Microscopy research and technique》2000,51(5):469-480
The study of energy pools and dynamics of specific pathways in living cells by microspectrofluorometry and fluorescence imaging produces spectral and topographic images characterizing structural and functional changes associated with cytopathology. Microspectro-fluorometry and fluorescence imaging have been applied, together with organelle morphometry to a number of cells mimicking certain cytopathologies, including melanoma cells, long-term malignant cells, and gene-defective cells. These investigations of cellular pathology indicate that there is a convergence of various physiopathological processes. Cellular states that have similarities include senescence, detoxification, and transformation. While the NAD(P)H metabolic transients have been studied before, our emphasis in this article is on very rapidly scanned fluorescence images related to organelle integration and photoinduced cellular senescence. 相似文献
9.
The discovery of aequorin and green fluorescent protein 总被引:11,自引:0,他引:11
10.
Monomolecular films of polymerized dimethyl-bis[pentacosadiinoic-oxyethyl] ammonium bromide (EDIPAB) provide one- and two-photon excited fluorescence that is sufficiently high to quantify the axial resolution of 3-D fluorescence microscopes. When scanned along the optical axis, the fluorescence of these layers is bright enough to allow online observation of the axial response of these microscopes, thus facilitating alignment and fluorescence throughput control. The layers can be used for directly measuring and monitoring the axial response of 4Pi-confocal microscopes, as well as for their initial alignment and phase adjustment. The proposed technique has the potential to supersede the conventional technique of calculating the derivative of the axial edges of a thick fluorescent layer. Coverslips with EDIPAB-layers can be used as substrates for the cultivation of cells. 相似文献
11.
J. A. Veerman M. F. Garcia-Parajo L. Kuipers & N. F. Van Hulst 《Journal of microscopy》1999,194(2-3):477-482
The most difficult task in near-field scanning optical microscopy (NSOM) is to make a high quality subwavelength aperture probe. Recently, we have developed high definition NSOM probes by focused ion beam (FIB) milling. These probes have a higher brightness, better polarization characteristics, better aperture definition and a flatter end face than conventional NSOM probes. We have determined the quality of these probes in four independent ways: by FIB imaging and by shear-force microscopy (both providing geometrical information), by far-field optical measurements (yielding throughput and polarization characteristics), and ultimately by single molecule imaging in the near-field. In this paper, we report on a new method using shear-force microscopy to study the size of the aperture and the end face of the probe (with a roughness smaller than 1.5 nm). More importantly, we demonstrate the use of single molecules to measure the full three-dimensional optical near-field distribution of the probe with molecular spatial resolution. The single molecule images exhibit various intensity patterns, varying from circular and elliptical to double arc and ring structures, which depend on the orientation of the molecules with respect to the probe. The optical resolution in the measurements is not determined by the size of the aperture, but by the high optical field gradients at the rims of the aperture. With a 70 nm aperture probe, we obtain fluorescence field patterns with 45 nm FWHM. Clearly, this unprecedented near-field optical resolution constitutes an order of magnitude improvement over far-field methods like confocal microscopy. 相似文献
12.
Single molecule mapping of the optical field distribution of probes for near-field microscopy 总被引:1,自引:0,他引:1
The most difficult task in near-field scanning optical microscopy (NSOM) is to make a high quality subwavelength aperture probe. Recently, we have developed high definition NSOM probes by focused ion beam (FIB) milling. These probes have a higher brightness, better polarization characteristics, better aperture definition and a flatter end face than conventional NSOM probes. We have determined the quality of these probes in four independent ways: by FIB imaging and by shear-force microscopy (both providing geometrical information), by far-field optical measurements (yielding throughput and polarization characteristics), and ultimately by single molecule imaging in the near-field. In this paper, we report on a new method using shear-force microscopy to study the size of the aperture and the end face of the probe (with a roughness smaller than 1.5 nm). More importantly, we demonstrate the use of single molecules to measure the full three-dimensional optical near-field distribution of the probe with molecular spatial resolution. The single molecule images exhibit various intensity patterns, varying from circular and elliptical to double arc and ring structures, which depend on the orientation of the molecules with respect to the probe. The optical resolution in the measurements is not determined by the size of the aperture, but by the high optical field gradients at the rims of the aperture. With a 70 nm aperture probe, we obtain fluorescence field patterns with 45 nm FWHM. Clearly, this unprecedented near-field optical resolution constitutes an order of magnitude improvement over far-field methods like confocal microscopy. 相似文献
13.
14.
K. J. Kwak T. Hosokawa N. Yamamoto† H. Muramatsu† M. Fujihira 《Journal of microscopy》2001,202(2):413-419
We present a new detection method to measure simultaneously surface potential and fluorescence intensity distributions using a combined scanning near-field optical microscope-atomic force microscope (SNOM-AFM). A surface potential image of phospholipid monolayers was obtained in non-contact mode using the SNOM-AFM with a thin-step etched optical fibre probe. For applying this technique, a phospholipid of dipalmitoylphosphatidylethanolamine labelled at the head with a nitrobenzoxadiazole group was used as a fluorescent and single component Langmuir–Blodgett film. It is well known that aggregation of the lipid molecules and their fluorescence intensities are very sensitive to its environmental conditions such as humidity and temperature. We demonstrated for the first time the near-field optical imaging and simultaneous observation of surface potentials with Maxwell stress microscopy. 相似文献
15.
16.
The deconvolution of fluorescence lifetime imaging microscopy (FLIM) data that were processed with global analysis techniques is described. Global analysis of FLIM data enables the determination of relative numbers of molecules in different protein reaction states on a pixel-by-pixel basis in cells. The three-dimensional fluorescence distributions of each protein state can then be calculated and deconvolved. High-resolution maps of the relative concentrations of each state are then obtained from the deconvolved images. We applied these techniques to quantitatively image the phosphorylation state of ErbB1 receptors tagged with green fluorescent protein in MCF7 cells. 相似文献
17.
K. D. NISWENDER S. M. BLACKMAN L. ROHDE M. A. MAGNUSON D. W. PISTON 《Journal of microscopy》1995,180(2):109-116
To determine the application limits of green fluorescent protein (GFP) as a reporter gene or protein tag, we expressed GFP by itself and with fusion protein partners, and used three different imaging methods to identify GFP fluorescence. In conventional epifluorescence photomicroscopy, GFP expressed in cells could be distinguished as a bright green signal over a yellow-green autofluorescence background. In quantitative fluorescence microscopy, however, the GFP signal is contaminated by cellular autofluorescence. Improved separation of GFP signal from HeLa cell autofluorescence was achieved by the combination of confocal scanning laser microscopy using 488-nm excitation, a rapid cut-on dichroic mirror and a narrow-bandpass emission filter. Two-photon excitation of GFP fluorescence at the equivalent of ? 390 nm provided better absorption than did 488-nm excitation. This resulted in increased signal/background but also generated a different autofluorescence pattern and appeared to increase GFP photobleaching. Fluorescence spectra similar to those of GFP alone were observed when GFP was expressed as a fusion protein either with glutathione-S-transferase (GST) or with glucokinase. Furthermore, purified GST?GFP fusion protein displayed an extinction coefficient and quantum yield consistent with values previously reported for GFP alone. In HeLa cells, the cytoplasmic GFP concentration must be greater than ? 1 μM to allow quantifiable discrimination over autofluorescence. However, lower expression levels may be detectable if GFP is targeted to discrete subcellular compartments, such as the plasma membrane, organelles or nucleus. 相似文献
18.
We describe in this paper a home-built scanning-probe setup that combines the high spatial resolution of a commercial atomic-force microscope (AFM) with the high sensitivity and the discriminative power of a confocal two-photon fluorescence microscope. This scheme offers the ability of acquiring simultaneous, directly correlated topography and optical images with high sensitivity and resolution, and was successfully tested using model systems, such as dye-loaded latex beads. As a first biological application, we studied the (un)stacking of grana membranes in the envelope-free plant chloroplasts. The topographs showed two grana layers attached together in a "native unit" 15-16 nm thick and 4 nm protrusions on their surface, which we assign to Photosystem II reaction center. The optical imaging did not resolve single photosynthetic proteins, but helped in identifying the grana and indicated that the protein conformation and the chromophore binding are intact. Furthermore, our instrument allowed a direct comparison between the cell morphology and the distribution of the signaling protein H-Ras in living cells, i.e. mouse fibroblasts. With our approach the nanometer-scale resolving power of AFM is improved with the chemical identification capabilities of optical techniques, thus opening up interesting possibilities in various areas of research, including material and life sciences. 相似文献
19.
The imaging performance in single-photon (1-p) and two-photon (2-p) fluorescence microscopy is described. Both confocal and conventional systems are compared in terms of the three-dimensional (3-D) point spread function and the 3-D optical transfer function. Images of fluorescent sharp edges and layers are modelled, giving resolution in transverse and axial directions. A comparison of the imaging properties is also given for a 4Pi confocal system. Confocal 2-p 4Pi fluorescence microscopy gives the best axial resolution in the sense that its 3-D optical transfer function has the strongest response along the axial direction. 相似文献
20.
Rajwa B Bernas T Acker H Dobrucki J Robinson JP 《Microscopy research and technique》2007,70(10):869-879
Autofluorescence (AF) originating from the cytoplasmic region of mammalian cells has been thoroughly investigated; however, AF from plasma membranes of viable intact cells is less well known, and has been mentioned only in a few older publications. Herein, we report results describing single- and two-photon spectral properties of a strong yellowish-green AF confined to the plasma-membrane region of transformed human hepatocytes (HepG2) grown in vitro as small three-dimensional aggregates or as monolayers. The excitation-emission characteristics of the membrane AF indicate that it may originate from a flavin derivative. Furthermore, the AF was closely associated with the plasma membranes of HepG2 cells, and its presence and intensity were dependent on cell metabolic state, membrane integrity and presence of reducing agents. This AF could be detected both in live intact cells and in formaldehyde-fixed cells. 相似文献