1.
As epidemiological studies report associations between ambient air pollution and adverse birth outcomes, it is important to understand determinants of exposures among pregnant women. We measured (48-h, personal exposure) and modeled (using outdoor ambient monitors and a traffic-based land-use regression model) NO, NO(2), fine particle mass and absorbance in 62 non-smoking pregnant women in Vancouver, Canada on 1-3 occasions during pregnancy (total N=127). We developed predictive models for personal measurements using modeled ambient concentrations and individual determinants of exposure. Geometric mean exposures of personal samples were relatively low (GM (GSD) NO=37 ppb (2.0); NO(2)=17 ppb (1.6); 'soot', as filter absorbance=0.8 10(-5) m(-1) (1.5); PM(2.2)=10 microg m(-3) (1.6)). Having a gas stove (vs. electric stove) in the home was associated with exposure increases of 89% (NO), 44% (NO(2)), 20% (absorbance) and 35% (fine PM). Interpolated concentrations from outdoor fixed-site monitors were associated with all personal exposures except NO(2). Land-use regression model estimates of outdoor air pollution were associated with personal NO and NO(2) only. The effects of outdoor air pollution on personal samples were consistent, with and without adjustment for other individual determinants (e.g. gas stove). These findings improve our understanding of sources of exposure to air pollutants among pregnant women and support the use of outdoor concentration estimates as proxies for exposure in epidemiologic studies.  相似文献   

2.
室内颗粒污染的源辨识与源解析   总被引:1,自引:0,他引:1  
辨识室内颗粒物来源与分析室内颗粒物元素特征称为源辨识与源解析,是进行室内空气污染控制与净化的理论依据与前提条件。本文通过对室内空气品质(IAQ)模型进行理论分析,阐明了室内外污染源与室内颗粒物浓度之间的关系。指出室内颗粒污染物研究应根据污染源已知与未知两种情况进行讨论,并针对不同的情况分别采用源辨识与源解析技术。  相似文献   

3.
An exposure study of children (aged 10-12 years) living in Santiago, Chile, was conducted. Personal, indoor and outdoor fine and inhalable particulate matter (< 2.5 .m in diameter, PM2.5 and < 10 microm in diameter, PM10, respectively), and nitrogen dioxide (NO2) were measured during pilot (N = 8) and main (N = 20) studies, which were conducted during the winters of 1998 and 1999, respectively. For the main study, personal, indoor and outdoor 24-h samples were collected for five consecutive days. Similar mean personal, indoor and outdoor PM2.5 concentrations (69.5, 68.5 and 68.1 microg/m3, respectively) were found. However, for coarse particles (calculated as the difference between measured PM10 and PM2.5, PM2.5-10), indoor and outdoor levels (35.4 and 47.4 microg/m3) were lower than their corresponding personal exposures (76.3 microg/m3). Indoor and outdoor NO2 concentrations were comparable (35.8 and 36.9 ppb) and higher than personal exposures (25.9 ppb). Very low ambient indoor and personal O3 levels were found, which were mostly below the method's limit of detection (LOD). Outdoor particles contributed significantly to indoor concentrations, with effective penetration efficiencies of 0.61 and 0.30 for PM2.5 and PM2.5-10, respectively. Personal exposures were strongly associated with indoor and outdoor concentrations for PM2.5, but weakly associated for PM2.5-10. For NO2, weak associations were obtained for indoor-outdoor and personal-outdoor relationships. This is probably a result of the presence of gas cooking stoves in all the homes. Median I/O, P/I and P/O ratios for PM2.5 were close to unity, and for NO2 they ranged between 0.64 and 0.95. These ratios were probably due to high ambient PM2.5 and NO2 levels in Santiago, which diminished the relative contribution of indoor sources and subjects' activities to indoor and personal PM2.5 and NO2 levels.  相似文献   

4.
Lim JM  Jeong JH  Lee JH  Moon JH  Chung YS  Kim KH 《Indoor air》2011,21(2):145-155
In this study, elemental composition of PM2.5 and the status of indoor/outdoor pollution were investigated in a commercial building near a roadside area in Daejeon, Korea. A total of 60 parallel PM2.5 samples were collected both on the roof (outdoor) and in an indoor office of a building near a highly congested road during the spring and fall of 2008. The concentrations of 23 elements were analysed from these PM2.5 samples using instrumental neutron activation analysis. PM2.5 levels in indoor environment (47.6 ± 16.5 μg/m(3)) were noticeably higher than the outdoor levels (37.7 ± 17.2 μg/m(3)) with the I/O concentration ratio of 1.37 ± 0.33 [correlation coefficient (r) = 0.89, P < 0.001]. Principal component analysis results coincidently showed the predominance of sources such as soil dust, traffic, oil/coal combustion and road dust for both indoor and outdoor microenvironments. An isolated source in the indoor environment was assigned to environmental tobacco smoke (ETS) with high factor loading of Ce, Cl, I, K, La and Zn. The overall results of our study indicate that the sources of indoor constituents were strongly dependent on outdoor processes except for the ones affected by independent sources such as ETS. PRACTICAL IMPLICATIONS: An improved understanding of the factors affecting the indoor PM2.5 concentration levels can lead to the development of an efficient management strategy to control health risks from exposure to indoor PM2.5 and related toxic components. A comparison of our comprehensive data sets indicated that most indoor PM2.5 and associated elemental species were strongly enriched by indoor source activities along with infiltration of ambient outdoor air for a naturally ventilated building.  相似文献   

5.
Several studies among adult populations showed that an array of outdoor and indoor sources of particles emissions contributed to personal exposures to atmospheric particles, with tobacco smoke playing a prominent role (J. Expo. Anal. Environ. Epidemiol. 6 (1996) 57, Environ. Int. 24 (1998) 405, Arch. Environ. Health 54 (1999) 95). The Vesta study was carried out to assess the role of exposure to traffic emissions in the development of childhood asthma. In this paper, we present data on 68 children aged 8-14 years, living in the metropolitan areas of Paris (n = 30), Grenoble (n = 15) and Toulouse (n = 23), France, who continuously carried, over 48 h, a rucksack that contained an active PM2.5 sampler. Data about home indoor sources were collected by questionnaires. In parallel, daily concentrations of PM10 in ambient air were monitored by local air quality networks. The contribution of indoor and outdoor factors to personal exposures was assessed using multiple linear regression models. Average personal exposure across all children was 23.7 microg/m3 (S.D. = 19.0 microg/m3), with local means ranging from 18.2 to 29.4 microg/m3. The final model explains 36% of the total between-subjects variance, with environmental tobacco smoke contributing for more than a third to this variability; presence of pets at home, proximity of the home to urban traffic emissions, and concomitant PM10 ambient air concentrations were the other main determinants of personal exposure.  相似文献   

6.
Residents of low-income multifamily housing can have elevated exposures to multiple environmental pollutants known to influence asthma. Simulation models can characterize the health implications of changing indoor concentrations, but quantifying the influence of interventions on concentrations is challenging given complex airflow and source characteristics. In this study, we simulated concentrations in a prototype multifamily building using CONTAM, a multizone airflow and contaminant transport program. Contaminants modeled included PM(2.5) and NO(2) , and parameters included stove use, presence and operability of exhaust fans, smoking, unit level, and building leakiness. We developed regression models to explain variability in CONTAM outputs for individual sources, in a manner that could be utilized in simulation modeling of health outcomes. To evaluate our models, we generated a database of 1000 simulated households with characteristics consistent with Boston public housing developments and residents and compared the predicted levels of NO(2) and PM(2.5) and their correlates with the literature. Our analyses demonstrated that CONTAM outputs could be readily explained by available parameters (R(2) between 0.89 and 0.98 across models), but that one-compartment box models would mischaracterize concentrations and source contributions. Our study quantifies the key drivers for indoor concentrations in multifamily housing and helps to identify opportunities for interventions. PRACTICAL IMPLICATIONS: Many low-income urban asthmatics live in multifamily housing that may be amenable to ventilation-related interventions such as weatherization or air sealing, wall and ceiling hole repairs, and exhaust fan installation or repair, but such interventions must be designed carefully given their cost and their offsetting effects on energy savings as well as indoor and outdoor pollutants. We developed models to take into account the complex behavior of airflow patterns in multifamily buildings, which can be used to identify and evaluate environmental and non-environmental interventions targeting indoor air pollutants which can trigger asthma exacerbations.  相似文献   

7.
Particulate matter (PM) air pollution derives from combustion and non‐combustion sources and consists of various chemical species that may differentially impact human health and climate. Previous reviews of PM chemical component concentrations and sources focus on high‐income urban settings, which likely differ from the low‐ and middle‐income settings where solid fuel (ie, coal, biomass) is commonly burned for cooking and heating. We aimed to summarize the concentrations of PM chemical components and their contributing sources in settings where solid fuel is burned. We searched the literature for studies that reported PM component concentrations from homes, personal exposures, and direct stove emissions under uncontrolled, real‐world conditions. We calculated weighted mean daily concentrations for select PM components and compared sources of PM determined by source apportionment. Our search criteria yielded 48 studies conducted in 12 countries. Weighted mean daily cooking area concentrations of elemental carbon, organic carbon, and benzo(a)pyrene were 18.8 μg m?3, 74.0 μg m?3, and 155 ng m?3, respectively. Solid fuel combustion explained 29%‐48% of principal component/factor analysis variance and 41%‐87% of PM mass determined by positive matrix factorization. Multiple indoor and outdoor sources impacted PM concentrations and composition in these settings, including solid fuel burning, mobile emissions, dust, and solid waste burning.  相似文献   

8.
Indoor air PM2.5 and PM10 samples were collected at the different types of indoor enviornment in the four hospitals and their adjacent outdoor environments in Guangzhou, China, during the summertime. The objectives of this study were (1) to characterize the indoor PM concentrations and associated carbonaceous species in hospitals, (2) to investigate the potential indoor sources and (3) to reconstruct carbonaceous composition in PM. Additionally, regression analysis was made to evaluate effect of outdoor sources to indoor PM levels and comparison was made between I/O levels in different types of indoor environment to evaluate effects of human activities and ventilation types to indoor PM levels.  相似文献   

9.
Urban PM2.5 (particulate matter with aerodynamic diameter smaller than 2.5 microm) is associated with excess mortality and other health effects. Stationary sources are regulated and considerable effort is being put into developing low-pollution vehicles and environment-friendly transportation systems. While waiting for technological breakthroughs in emission controls, the current work assesses the exposure reductions achievable by a complementary means: efficient filtration of supply air in buildings. For this purpose infiltration factors for buildings of different ages are quantified using Exposures of Adult Urban Populations in Europe Study (EXPOLIS) measurements of indoor and outdoor concentrations in a population-based probability sample of residential and occupational buildings in Helsinki, Finland. These are entered as inputs into an evaluated simulation model to compare exposures in the current scenario with an alternative scenario, where the distribution of ambient PM2.5 infiltration factors in all residential and occupational buildings are assumed to be similar to the subset of existing occupational buildings using supply air filters. In the alternative scenario exposures to ambient PM2.5 were reduced by 27%. Compared with source controls, a significant additional benefit is that infiltration affects particles from all outdoor sources. The large fraction of time spent indoors makes the reduction larger than what probably can be achieved by local transport policies or other emission controls in the near future. PRACTICAL IMPLICATIONS: It has been suggested that indoor concentrations of ambient particles and the associated health risks can be reduced by using mechanical ventilation systems with supply air filtering in buildings. The current work quantifies the effects of these concentration reductions on population exposures using population-based data from Helsinki and an exposure model. The estimated exposure reductions suggest that correctly defined building codes may reduce annual premature mortality by hundreds in Finland and by tens of thousands in the developed world altogether.  相似文献   

10.
There are limited data on exposures to ambient air toxics experienced by inhabitants of urban areas in developing countries that have high levels of outdoor air pollution. In particular, little is known about exposures experienced by individuals working outdoors - typically as part of the informal sector of the economy - as compared to workers in office-type environments that approach the indoor air quality conditions of the more developed countries. The objective of this study is to explore these differences in personal exposures using a convenience sample of 68 outdoor and indoor workers living in Mexico City (higher outdoor air pollution) and Puebla (lower outdoor air pollution), Mexico. Occupational and non-occupational exposures to airborne volatile organic compounds (VOCs) were monitored during a 2 day period, monitoring 2 consecutives occupational and non-occupational periods, using organic vapor monitors (OVMs). Socio-demographic and personal time-location-activity information were collected by means of questionnaires and activity logs. Outdoor workers experienced significantly higher exposures to most VOCs compared to indoor workers in each of these cities. The outdoor workers in Mexico City had the highest exposures both during- and off-work, with maximum occupational exposures for toluene, MTBE, n-pentane, and d-limonene exceeding 1 mg/m(3). The inter-city pattern of exposures between the outdoor workers is consistent with the higher outdoor air pollution levels in Mexico City, and is above exposures reported for urban areas of the more developed countries. Results from this study suggest that elevated outdoor air pollution concentrations have a larger impact on outdoor workers' personal exposures compared to the contribution from indoor pollution sources. This contrasts with the more dominant role of indoor air VOC contributions to personal exposures typically reported for urban populations of the more developed countries.  相似文献   

11.
The advent of spatial analysis and geographic information systems (GIS) has led to studies of chronic exposure and health effects based on the rationale that intra-urban variations in ambient air pollution concentrations are as great as inter-urban differences. Such studies typically rely on local spatial covariates (e.g., traffic, land use type) derived from circular areas (buffers) to predict concentrations/exposures at receptor sites, as a means of averaging the annual net effect of meteorological influences (i.e., wind speed, wind direction and insolation). This is the approach taken in the now popular land use regression (LUR) method. However spatial studies of chronic exposures and temporal studies of acute exposures have not been adequately integrated. This paper presents an innovative LUR method implemented in a GIS environment that reflects both temporal and spatial variability and considers the role of meteorology. The new source area LUR integrates wind speed, wind direction and cloud cover/insolation to estimate hourly nitric oxide (NO) and nitrogen dioxide (NO(2)) concentrations from land use types (i.e., road network, commercial land use) and these concentrations are then used as covariates to regress against NO and NO(2) measurements at various receptor sites across the Vancouver region and compared directly with estimates from a regular LUR. The results show that, when variability in seasonal concentration measurements is present, the source area LUR or SA-LUR model is a better option for concentration estimation.  相似文献   

12.
The indoor air quality of 27 primary schools located in the city centre and suburbs of Antwerp, Belgium, was assessed. The primary aim was to obtain correlations between the various pollutant levels. Indoor:outdoor ratios and the building and classroom characteristics of each school were investigated. This paper presents results on indoor and local outdoor PM2.5 mass concentrations, its elemental composition in terms of K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb, Al, Si, S, and Cl, and its black smoke content. In addition, indoor and local outdoor levels of the gases NO2, SO2, O3, and BTEX (benzene, toluene, ethyl benzene, and xylene isomers) were determined. Black smoke, NO2, SO2 and O3, occurred at indoor:outdoor ratios below unity, indicating their significant outdoor sources. No linear correlation was established between indoor and outdoor levels for PM2.5 mass concentrations and BTEX; their indoor:outdoor ratios exceeded unity except for benzene. Classroom PM2.5 occurred with a different elemental composition than local outdoor PM2.5. The re-suspension of dust because of room occupation is probably the main contributor for the I/O ratios higher than 1 reported for elements typically constituting dust particles. Finally, increased benzene concentrations were reported for classrooms located at the lower levels. PRACTICAL IMPLICATIONS: The elevated indoor PM2.5, and BTEX concentrations in primary school classrooms, exceeding the ambient concentrations, raise concerns about possible adverse health effects on susceptible children. This is aggravated by the presence of carpets and in the case of classrooms at lower levels. Analysis of PM2.5's elemental composition indicated a considerable contribution of soil dust to indoor PM2.5 mass. In order to set adequate threshold values and guidelines, detailed information on the health impact of specific PM2.5 composites is needed. The results suggest that local outdoor air concentrations measurements do not provide an accurate estimation of children's personal exposures to the identified air pollutants inside classrooms.  相似文献   

13.
Yang W  Lee K  Chung M 《Indoor air》2004,14(2):105-111
Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor NO2 concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and NO2 source strength were estimated. Geometric means of ventilation rate were 1.44 air change per hour (ACH) in Brisbane, assuming a residential NO2 deposition constant of 1.05/h, and 1.36 ACH in Seoul, with the measured residential NO2 deposition constant of 0.94/h. Source strengths of NO2 were 15.8 +/- 18.2 and 44.7 +/- 38.1 microg/m3/h in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.  相似文献   

14.
对上海市某住宅建筑室内外PM10、PM2.5、PM1的浓度进行了测量,研究了最小通风量(外门窗关闭)条件下3种天气时颗粒浓度随时间变化的规律以及相关性,分析了颗粒物浓度与环境温湿度参数之间的关系。研究结果显示,测试期间,室内外空气中细颗粒(PM 2.5)占可吸入颗粒(PM 10)浓度比例分别达65%和87%以上;无明显室内源时,I/O比值小于1且随粒径减小而减小;室内外颗粒浓度相关性与粒径大小有关系,PM1、PM2.5的浓度相关性大于PM10。研究还表明,颗粒物浓度的关联性与天气状况有关系,多云、雨天和阴天时浓度关联性有显著差别;颗粒物的浓度受到室内外温湿度的影响,且受天气状况影响而呈现复杂性。  相似文献   

15.
Cao JJ  Lee SC  Chow JC  Cheng Y  Ho KF  Fung K  Liu SX  Watson JG 《Indoor air》2005,15(3):197-204
Six residences were selected (two roadside, two urban, and two rural) to evaluate the indoor-outdoor characteristics of PM(2.5) (aerodynamic diameter <2.5 microm) carbonaceous species in Hong Kong during March and April 2004. Twenty-minute-averaged indoor and outdoor PM(2.5) concentrations were recorded by DustTrak samplers simultaneously at each site for 3 days to examine diurnal variability of PM(2.5) mass concentrations and their indoor-to-outdoor (I/O) ratios. Daily (24-h average) indoor/outdoor PM(2.5) samples were collected on pre-fired quartz-fiber filters with battery-powered portable mini-volume samplers and analyzed for organic and elemental carbon (OC, EC) by thermal/optical reflectance (TOR) following the Interagency Monitoring of Protected Visual Environments (IMPROVE) protocol. The average indoor and outdoor concentrations of 24 h PM(2.5) were 56.7 and 43.8 microg/m(3), respectively. The short-term PM(2.5) profiles indicated that the penetration of outdoor particles was an important contributor to indoor PM(2.5), and a household survey indicated that daily activities were also sources of episodic peaks in indoor PM(2.5). The average indoor OC and EC concentrations of 17.1 and 2.8 microg/m(3), respectively, accounted for an average of 29.5 and 5.2%, respectively, of indoor PM(2.5) mass. The average indoor OC/EC ratios were 5.8, 9.1, and 5.0 in roadside, urban, and rural areas, respectively; while average outdoor OC/EC ratios were 4.0, 4.3, and 4.0, respectively. The average I/O ratios of 24 h PM(2.5), OC, and EC were 1.4, 1.8, and 1.2, respectively. High indoor-outdoor correlations (r(2)) were found for PM(2.5) EC (0.96) and mass (0.81), and low correlations were found for OC (0.55), indicative of different organic carbon sources indoors. A simple model implied that about two-thirds of carbonaceous particles in indoor air are originated from outdoor sources. PRACTICAL IMPLICATIONS: Indoor particulate pollution has received more attentions in Asia. This study presents a case study regarding the fine particulate matter and its carbonaceous compositions at six residential homes in Hong Kong. The characteristics and relationship of atmospheric organic and elemental carbon were discussed indoors and outdoors. The distribution of eight carbon fractions was first reported in indoor samples to interpret potential sources of indoor carbonaceous particles. The data set can provide significant scientific basis for indoor air quality and epidemiology study in Hong Kong and China.  相似文献   

16.
Human exposures to ultrafine particles (UFP) are poorly characterized given the potential associated health risks. Residences are important sites of exposure. To characterize residential exposures to UFP in some circumstances and to investigate governing factors, seven single-family houses in California were studied during 2007-2009. During multiday periods, time-resolved particle number concentrations were monitored indoors and outdoors and information was acquired concerning occupancy, source-related activities, and building operation. On average, occupants were home for 70% of their time. The geometric mean time-average residential exposure concentration for 21 study subjects was 14,500 particles per cm(3) (GSD = 1.8; arithmetic mean ± standard deviation = 17,000 ± 10,300 particles per cm(3)). The average contribution to residential exposures from indoor episodic sources was 150% of the contribution from particles of outdoor origin. Unvented natural-gas pilot lights contributed up to 19% to exposure for the two households where present. Episodic indoor source activities, most notably cooking, caused the highest peak exposures and most of the variation in exposure among houses. Owing to the importance of indoor sources and variations in the infiltration factor, residential exposure to UFP cannot be characterized by ambient measurements alone. PRACTICAL IMPLICATIONS: Indoor and outdoor sources each contribute to residential ultrafine particle (UFP) concentrations and exposures. Under the conditions investigated, peak exposure concentrations indoors were associated with cooking, using candles, or the use of a furnace. Active particle removal systems can mitigate exposure by reducing the persistence of particles indoors. Eliminating the use of unvented gas pilot lights on cooking appliances could also be beneficial. The study results indicate that characterization of human exposure to UFP, an air pollutant of emerging public health concern, cannot be accomplished without a good understanding of conditions inside residences.  相似文献   

17.
Sources of polycyclic aromatic hydrocarbons (PAHs) in the Black River and Ashtabula River sediments were apportioned using a factor analysis (FA) model with nonnegative constraints. Source profiles, contributions (microg/g) and percent contributions are determined with no prior knowledge of sources. The FA model includes scaling and backscaling of data with average PAH concentrations, without sample normalization. The present work is a follow-up to studies that used a chemical mass balance model to apportion sources to the same data sets. Literature source profiles, modified based on gas/particle partitioning of individual PAHs, from nine PAH sources were considered for comparison. FA results for a three-source solution indicate traffic (58%), coke oven (26%), and wood burning/coal tar (16%) are the primary PAH sources to Black River sediments. The primary PAH sources to the Ashtabula River sediments are traffic (51%), coke oven (44%), and wood burning (5%). This work supports the previous studies of Black River and Ashtabula River PAHs by CMB model. In addition, FA provides a more realistic fit to Ashtabula River model data by eliminating 100% contributions from one source.  相似文献   

18.
Impacts of individual behavior on personal exposure to particulate matter (PM) and the associated individual health effects are still not well understood. As outdoor PM concentrations exhibit highly temporal and spatial variations, personal PM exposure depends strongly on individual trajectories and activities. Furthermore, indoor environments deserve special attention due to the large fraction of the day people spend indoors. The indoor PM concentration in turn depends on infiltrated outdoor PM and indoor particle sources, partially caused by the activities of people indoor.We present an approach to estimate PM2.5 exposure levels for individuals based upon existing data sources and models. For this pilot study, six persons kept 24-hour diaries and GPS tracks for at least one working day and one weekend day, providing their daily activity profiles and the associated geographical locations. The survey took place in the city of Münster, Germany in the winter period between October 2006 and January 2007. Environmental PM2.5 exposure was estimated by using two different models for outdoor and indoor concentrations, respectively. For the outdoor distribution, a dispersion model was used and extended by actual ambient fixed site measurements. Indoor concentrations were modeled using a simple mass balance model with the estimated outdoor concentration fraction infiltrated and indoor activities estimated from the diaries. A limited number of three 24-hour indoor measurements series for PM were performed to test the model performance.The resulting average daily exposure of the 14 collected profiles ranged from 21 to 198 µg m− 3 and showed a high variability over the day as affected by personal behavior. Due to the large contribution of indoor particle sources, the mean 24-hour exposure was in most cases higher than the daily means of the respective outdoor fixed site monitors.This feasibility study is a first step towards a more comprehensive modeling approach for personal exposure, and therefore restricted to limited data resources. In future, this model framework not only could be of use for epidemiological research, but also of public interest. Any individual operating a GPS capable device may become able to obtain an estimate of its personal exposure along its trajectory in time and space. This could provide individuals a new insight into the influence of personal habits on their exposure to air pollution and may result in the adaptation of personal behavior to minimize risks.  相似文献   

19.
An instrumented bicycle was used to elucidate particulate matter exposures along bicycle routes passing through a variety of land uses over 14 days during summer and fall in a mid-latitude traffic dominated urban setting. Overall, exposures were low or comparable to those found in studies elsewhere (mean PM(2.5) and PM(10) concentrations over each daily bicycle traverse varied between 7-34 microg m(-3) and 26-77 microg m(-3) respectively). Meteorological factors were responsible for significant day-to-day variability with PM(2.5) positively correlated with air temperature, PM(10) negatively correlated with precipitation, and ultrafine particles negatively correlated with both air temperature and wind speed. On individual days, land use and proximity to traffic were factors significantly affecting exposure along designated bicycle routes. While concentrations of PM(2.5) were found to be relatively spatially uniform over the length of the study route, PM(10) showed a more heterogeneous spatial distribution. Specifically, construction sites and areas susceptible to the suspension of road dust have higher concentrations of coarse particles. Ultrafine particles were also heterogeneously distributed in space, with areas with heavy traffic volumes having the highest concentrations. Observations show qualitative agreement in terms of spatial patterns with a land-use regression (LUR) model for annual PM(2.5) concentrations.  相似文献   

20.
Characterization of emissions from burning incense   总被引:3,自引:0,他引:3  
The primary objective of this study was to improve the characterization of particulate matter emissions from burning incense. Emissions of particulate matter were measured for 23 different types of incense using a cyclone/filter method. Emission rates for PM2.5 (particulate matter less than 2.5 microm in aerodynamic diameter) ranged from 7 to 202 mg/h, and PM2.5 emission factors ranged from 5 to 56 mg/g of incense burned. Emission rates were also determined using an electrical low pressure impactor (ELPI) and a small electrostatic precipitator (ESP), and emission rates were compared to those determined using the cyclone/filter method. Emission rates determined by the ELPI method were consistently lower than those determined by the cyclone/filter method, and a linear regression correlation was found between emission rates determined by the two methods. Emission rates determined by the ESP method were consistently higher than those determined by the cyclone/filter method, indicating that the ESP may be a more effective method for measuring semivolatile particle emissions. A linear regression correlation was also found between emission rates determined by the ESP and cyclone/filter methods. Particle size distributions were measured with the ELPI, and distributions were found to be similar for most types of incense that were tested. Size distributions by mass typically ranged from approximately 0.06 to 2.5 microm in aerodynamic diameter, with peak values between 0.26 and 0.65 microm. Results indicated that burning incense emits fine particulate matter in large quantities compared to other indoor sources. An indoor air quality model showed that indoor concentrations of PM25 can far exceed the outdoor concentrations specified by the US EPA's National Ambient Air Quality Standards (NAAQS), so incense smoke can pose a health risk to people due to inhalation exposure of particulate matter. Emissions of carbon monoxide (CO), nitric oxide (NO), and sulfur dioxide (SO2) were also measured for seven types of incense. Emission rates of the gaseous pollutants were sufficient to cause indoor concentrations, estimated using the indoor air quality model, to exceed the outdoor concentrations specified by the NAAQS under certain conditions. However, the incense samples that were tested would fill a room with thick smoke under these conditions.  相似文献   