首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
A linear array of eight individual addressable microelectrodes has been developed in order to perform high-throughput scanning electrochemical microscopy (SECM) imaging of large sample areas in contact regime. Similar to previous reports, the soft microelectrode array was fabricated by ablating microchannels on a polyethylene terephthalate (PET) film and filling them with carbon ink. Improvements have been achieved by using a 5 μm thick Parylene coating that allows for smaller working distances, as the probe was mounted with the Parylene coating facing the sample surface. Additionally, the application of a SECM holder allows scanning in contact regime with a tilted probe, reducing the topographic effects and assuring the probe bending direction. The main advantage of the soft microelectrode array is the considerable decrease in the experimental time needed for imaging large sample areas. Additionally, soft microelectrode arrays are very stable and can be used several times, since the electrode surface can be regenerated by blade cutting. Cyclic voltammograms and approach curves were recorded in order to assess the electrochemical properties of the device. An SECM image of a gold on glass chip was obtained with high resolution and sensitivity, proving the feasibility of soft microelectrode arrays to detect localized surface activity. Finite element method (FEM) simulations were performed in order to establish the effect of diffusion layer overlapping between neighboring electrodes on the respective approach curves.  相似文献   

3.
4.
The fabrication and characterization of novel micropipet probes for use in scanning electrochemical microscopy (SECM) are described. These can be used to dispense small (pL) amounts of a solution while monitoring the electrochemical response at a substrate and at a ring electrode tip on the micropipet probe. The probes were constructed by insulating gold-coated borosilicate micropipets with electrophoretic paint and exposing a ring electrode at the tip by heat treatment. Characterization of the probes was performed using scanning electron microscopy, cyclic voltammetry, and SECM approach curve experiments. Routine construction of tips with diameters of the order of 3 microm was possible using this technique. The probes exhibited stable steady-state currents and positive and negative feedback approach curves that agreed with those predicted by theory. Demonstrative SECM imaging experiments were performed using a picodispenser to continuously dispense an electroactive solution (ferrocenemethanol) to the SECM cell while the probe was located within a few micrometers of a Pt substrate surface. Oxidation of the dispensed electroactive solution was performed at the substrate, and feedback currents were measured at the probe tip by holding the gold ring at a reducing potential. This mode of tip-dispensing SECM was used to obtain images of a platinum substrate electrode while monitoring both the substrate current and the feedback current at the probe.  相似文献   

5.
This paper presents a microfluidic push-pull probe for scanning electrochemical microscopy (SECM) consisting of a working microelectrode, an integrated counter/reference electrode and two microchannels for pushing and pulling an electrolyte solution to and away from a substrate. With such a configuration, a droplet of a permanently renewed redox mediator solution is maintained just at the probe tip to carry out SECM measurements on initially dry substrates or in microenvironments. For SECM imaging purposes, the probe fabricated in a soft polymer material is used in a contact regime. SECM images of various gold-on-glass samples demonstrate the proof-of-concept of a push-pull probe for local surface activity characterization with high spatial resolution even on vertically oriented substrates. Finite element computations were performed to guide the improvement of the probe sensitivity.  相似文献   

6.
Scanning electrochemical microscopy (SECM) was applied to the immunoassay of leukocidin, which is a toxic protein produced by methicillin-resistant Staphylococcus aureus (MRSA), with the intention of developing and early diagnostic for MRSA infection. An antibody-chip for leukocidin was prepared by self-assembling of anti-leukocidin on a protein A-coated glass substrate. A sample solution containing leukocidin was spotted onto the antibody-chip, followed by labeling with horseradish peroxidase (HRP) via a sandwich method. The reduction current of the oxidized form of ferrocenylmethanol generated by the HRP reaction was monitored to view SECM images of the spot of captured leukocidin. The amplitude of reduction current depended on the concentrations of sample solutions used for making spots. This SECM-based immunoassay detects as low as 5.25 pg mL(-1) leukocidin.  相似文献   

7.
P Sun  Z Zhang  J Guo  Y Shao 《Analytical chemistry》2001,73(21):5346-5351
A novel method for fabrication of nanometer-sized electrodes and tips suitable for scanning electrochemical microscopy (SECM) is reported. A fine etched Pt wire is coated with polyimide, which was produced by polymerization on the Pt surface initiated by heat. This method can prepare electrodes with effective radii varying from a few to hundreds of nanometers. Scanning electron microscopy, cyclic voltammetry, and SECM were used to characterize these electrodes. Well-defined steady-state voltammograms could be obtained in aqueous or in 1,2-dichloroethane solutions. This method produced the nanoelectrodes with exposed Pt on the apex, and they can also be employed as the nanotips for SECM investigations. Different sizes of Pt nanotips made by this method were employed to evaluate the kinetics of the redox reaction of Ru(NH3)6(3+) on the surface of a large Pt electrode by SECM, and the standard rate constant kappa0 of this system was calculated from the best fit of the SECM approach curve. This result is similar to the values obtained by analysis of the obtained voltammetric data.  相似文献   

8.
Alternating current impedance imaging of a 6-microm thick membrane containing conical-shaped pores (60-nm and 2.5-microm diameter openings) using scanning electrochemical microscopy (SECM) is described. Impedance images of the pore openings were obtained by rastering a glass-sealed conically shaped Pt tip (approximately 1-microm radius) above the membrane surface, while measuring the total impedance between the tip and a large area Pt electrode located on the opposite side of the membrane. Individual pore openings in the high pore density membrane (approximately 8 x 10(4) pores/cm2) are observed in the SECM impedance image. The image contrast is due to the decrease in tip and membrane resistance, in the vicinity of the pore opening. An equivalent circuit for the SECM cell and membrane is proposed and evaluated against the measured SECM imaging impedance. Criteria for employing SECM in impedance mode to image membranes are discussed.  相似文献   

9.
This report describes a rapid solid-phase melting curve analysis method for single-nucleotide polymorphism (SNP) genotyping. The melting curve analysis is based on dynamic allele-specific hybridization (DASH). The DNA duplexes are conjugated on beads that are immobilized on the surface of a microheater chip with integrated heaters and temperature sensors. SNP on PCR products were scored, illustrating the sensitivity and robustness of the system. The method is based on random bead immobilization by microcontact printing. Single-bead detection and multiplexing were performed with a heating rate more than 20 times faster than conventional DASH. Analyses that took more than 15 min could be performed in less that 1 min, enabling ultrarapid SNP analysis. In addition, an array version of the chip was implemented enabling the preparation of an array of bead arrays for high-throughput and rapid SNP genotyping.  相似文献   

10.
Undifferentiated and differentiated PC12 cells were imaged with the constant-distance mode of scanning electrochemical microscopy (SECM) using carbon ring and carbon fiber tips. Two types of feedback signals were used for distance control: the electrolysis current of a mediator (constant-current mode) and the impedance measured by the SECM tip (constant-impedance mode). The highest resolution was achieved using carbon ring electrodes with the constant-current mode. However, the constant-impedance mode has the important advantages that topography and faradaic current can be measured simultaneously, and because no mediator is required, the imaging can take place directly in the cell growth media. It was found that vesicular release events do not measurably alter the impedance, but the depolarizing solution, 105 mM K+, produces a dramatic impedance change such that constant-distance imaging cannot be performed during application of the stimulus. However, by operating the tip in the constant-height mode, cell morphology (via a change in impedance) and vesicular release could be detected simultaneously while moving the tip across the cell. This work represents a significant improvement over previous SECM imaging of model neurons, and it demonstrates that the combination of amperometry and constant-impedance SECM has the potential to be a powerful tool for investigating the spatial distribution of neurotransmitter release in vitro.  相似文献   

11.
Lee Y  Bard AJ 《Analytical chemistry》2002,74(15):3626-3633
A technique that combines scanning electrochemical microscopy (SECM) and optical microscopy (OM) was implemented with a new probe tip. The tip for scanning electrochemicaVoptical microscopy (SECM/OM) was constructed by insulating a typical gold-coated near-field scanning optical microscopy tip using electrophoretic anodic paint. Once fabricated, the tip was characterized by steady-state cyclic voltammetry, as well as optical and electrochemical approach experiments. This tip generated a stable steady-state current and well-defined SECM approach curves for both conductive and insulating substrates. Durable tips whose geometry was a ring with < 1 microm as outer ring radius could be consistently fabricated. Simultaneous electrochemical and optical images of an interdigitated array electrode were obtained with a resolution on the micrometer scale, demonstrating good performance of the tip as both an optical and an electrochemical probe for imaging microstructures. The SECM feedback current measurements were successfully employed to determine tip-substrate distances for imaging.  相似文献   

12.
Scanning electrochemical microscopy (SECM), operated in reverse imaging mode (RIM), has been used to visualize the steady-state transport of molecules entering into porous membranes. RIM imaging is advantageous for investigating transport across biological membranes in situations where the SECM tip can access only the exterior membrane surface. Examples of RIM images of a synthetic membrane (mica with pores filled with the ion-selective polymer Nafion) and a biological membrane (hairless mouse skin) recorded during diffusive and iontophoretic transport, are reported. RIM imaging during diffusive transport allows visualization of the depletion of solute molecules in the solution adjacent to the pore openings. However, an accumulation of solute molecules above the pore opening is observed during iontophoresis, which is a consequence of the separation of the solute from the solvent (i.e., ultrafiltration). The separation results from differences in the rates of molecule transfer across the pore/solution interface when electroosmotic flow is operative. The results suggest that RIM imaging may be useful for measuring the kinetics of interfacial molecule transfer at biological membranes.  相似文献   

13.
Scanning electrochemical microscopy (SECM) and a recently developed microelectrode array microscope have been used to study localized corrosion and electron-transfer characteristics of native oxide layers of type 304 stainless steels. The I-/I3- redox couple was employed as a mediator and allowed sensitive detection of oxide breakdown events. In solutions containing I-, a signal at the microelectrode was observed on type 304 stainless steel surfaces at active pitting corrosion sites. Under conditions where pitting corrosion occurs, SECM was used to track the temporal characteristics of the reaction in a spatial manner. However, because of the time required to create an image, much of the temporal information was not obtained. To improve the temporal resolution of the measurement, microelectrode array microscopy (MEAM) was developed as a parallel method of performing SECM. The demonstration shown reveals the potential of MEAM for analysis of surface chemistry on temporal and spatial domains.  相似文献   

14.
Lee Y  Ding Z  Bard AJ 《Analytical chemistry》2002,74(15):3634-3643
A technique that combines scanning electrochemical microscopy (SECM) and scanning optical microscopy (OM) was developed. Simultaneous scanning electrochemical/optical microscopy (SECM/OM) was performed by a special probe tip, which consists of an optical fiber core for light passage, surrounded by a gold ring electrode, and an outermost electrophoretic insulating sheath, with the tip attached to a tuning fork. To regulate the tip-substrate distance, either the shear force or the SECM tip current was employed as the feedback signal. The application of a quartz crystal tuning fork (32.768 kHz) for sensing shear force allowed simultaneous topographic, along with SECM and optical imaging in a constant-force mode. The capability of this technique was confirmed by obtaining simultaneously, for the first time, topographic, electrochemical, and optical images of an interdigitated array electrode. Current feedback from SECM also provided simultaneous electrochemical and optical images of relatively soft samples, such as a polycarbonate membrane filter and living diatoms in a constant-current mode. This mode should be useful in mapping the biochemical activity of a living cell.  相似文献   

15.
The two known phases of CuTCNQ and TCNQ (TCNQ = 7,7',8,8'-tetracyanoquinodimethane) have been probed by scanning electrochemical microscopy (SECM) in the feedback mode. The first use of this technique for distinguishing differences in the electronic properties of semiconductor phases exploits the large differences in conductivity that exist between CuTCNQ and the parent TCNQ material and also between the CuTCNQ phases I and II. However, the packing density of the individual CuTCNQ crystals in a film structure also is shown to influence the SECM feedback response. Finally, it is shown that films of pure phase II material or mixtures of the phases can be mapped using feedback mode SECM. The SECM method provides valuable insights for elucidating properties of semiconducting solids that are mounted on insulating substrates.  相似文献   

16.
Zoski CG  Liu B  Bard AJ 《Analytical chemistry》2004,76(13):3646-3654
Finite conical electrodes, which are of particular interest as probes for imaging of surfaces using scanning electrochemical microscopy (SECM), in kinetic studies and in probing thin films were investigated. Theoretical SECM tip current-distance feedback (approach) curves for a finite conical electrode were calculated by numerical (finite element) analysis and compared to an earlier approximate model. The SECM curves obtained depended on the ratio of the base radius of the cone to the height of the cone and on the thickness of the insulating sheath. A new approach to fabricating conical tips of Pt in glass is described. These were used to obtain approach curves over both electrically conducting and insulating substrates. Comparison of experimental and simulated SECM approach curves provided a sensitive method of evaluating the size and shape of finite conical electrodes.  相似文献   

17.
This Article reports the use of scanning electrochemical microscopy (SECM) for the quantitative study of acid-induced dissolution. An ultramicroelectrode (UME) is used to generate a flux of protons galvanostatically just above a sample surface, creating controlled acid challenges relevant to acid erosion. The electrochemical technique produces etch features in the sample, which are characterized by white light interferometry (WLI). The technique has been applied to bovine enamel where understanding the kinetics of dissolution is important in the context of acid erosion. Dissolution has been observed as a fast process, but the high rates of mass transport in SECM allow the surface kinetics of dissolution to be evaluated. Key attributes of SECM for these studies are the ability to deliver high, controllable, and local acid challenges in a defined way and that multiple dissolution measurements can be performed on one sample, eliminating intersample variability effects. A novel moving boundary finite element model has been designed to describe the etching process, which allows the etch kinetics to be evaluated quantitatively, simply by measuring the size and shape of etch features over time.  相似文献   

18.
The oxygen reduction reaction (ORR) in acidic medium was studied on different electrode materials by scanning electrochemical microscopy (SECM) operating in a new variation of the tip generation-substrate collection mode. An ultramicroelectrode tip placed close to the substrate electrode oxidizes water to oxygen at a constant current. The substrate is held at a potential where the tip-generated oxygen is reduced and the resulting substrate current is measured. By changing the substrate potential, it is possible to obtain a polarization (current-potential) curve, which depends on the electrocatalytic activity of the substrate material. The main difference between this mode and the classical feedback SECM mode of operation is that the feedback diffusion process is not required for the measurement, allowing its application for studying the ORR in acidic solutions. Activity-sensitive images of heterogeneous surfaces, e.g., with Pt and Au electrodes, were obtained from the substrate current when the x-y plane was scanned with the tip. The usefulness of this technique for imaging electrocatalytic activity of smooth metallic electrodes and of highly dispersed fuel cell-type electrocatalysts was demonstrated. The application of this method to the combinatorial chemical analysis of electrode materials and electrocatalysts is discussed.  相似文献   

19.
The electrochemical behavior of electrodes made by sealing carbon nanofibers in glass or with electrophoretic paint has been studied by scanning electrochemical microscopy (SECM). Because of their small electroactive surface area, conical geometry with a low aspect ratio and high overpotential for proton and oxygen reduction, carbon nanofiber (CNF) electrodes are promising candidates for producing electrode nanogaps, imaging with high spatial resolution and for the electrodeposition of single metal nanoparticles (e.g., Pt, Pd) for studies as electrocatalysts. By using the feedback mode of the SECM, a CNF tip can produce a gap that is smaller than 20 nm from a platinum disk. Similarly, the SECM used in a tip-collection substrate-generation mode, which subsequently shows a feedback interaction at short distances, makes it possible to detect a single CNF by another CNF and then to form a nanometer gap between the two electrodes. This approach was used to image vertically aligned CNF arrays. This method is useful in the detection in a homogeneous solution of short-lifetime intermediates, which can be electrochemically generated at one electrode and collected at the second at distances that are equivalent to a nanosecond time scale.  相似文献   

20.
Combined scanning electrochemical atomic force microscopy (SECM-AFM) is a recently introduced scanned probe microscopy technique where the probe, which consists of a tip electrode and integrated cantilever, is capable of functioning as both a force sensor, for topographical imaging, and an ultramicroelectrode for electrochemical imaging. To extend the capabilities of the technique, two strategies for noncontact amperometric imaging-in conjunction with contact mode topographical imaging-have been developed for the investigation of solid-liquid interfaces. First, SECM-AFM can be used to image an area of the surface of interest, in contact mode, to deduce the topography. The feedback loop of the AFM is then disengaged and the stepper motor employed to retract the tip a specified distance from the sample, to record a current image over the same area, but with the tip held in a fixed x-y plane above the surface. Second, Lift Mode can be employed, where a line scan of topographical AFM data is first acquired in contact mode, and the line is then rescanned to record SECM current data, with the tip maintained at a constant distance from the target interface, effectively following the contours of the surface. Both approaches are exemplified with SECM feedback and substrate generation-tip collection measurements, with a 10-microm-diameter Pt disk UME serving as a model substrate. The approaches described allow electrochemical images, acquired with the tip above the surface, to be closely correlated with the underlying topography, recorded with the tip in intimate contact with the surface.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号