首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Capillary electrophoresis (CE) has been combined with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) and radionuclide detection to assay mass-limited biological samples. Nanovial sampling techniques enable injections into the CE capillary from 50 to 150-nL volume samples; after the separation, nanoliter fraction collection combines the CE effluent with a MALDI matrix and minimizes sample spreading, thus allowing both MALDI MS and radionuclide detection on the CE fractions. MALDI MS complements the elution time information of CE by providing accurate molecular mass data, and radionuclide detection provides zeptomole limits of detection with quantitative information. While MALDI MS detects all fully processed peptides at sufficient concentration, culturing the neuron in media containing 35S-Met provides selective radionuclide detection of newly synthesized methionine-containing peptides. The analysis and detection of the expected neuropeptides and hormones in a single 40-microm bag cell neuron from Aplysia californica with CE/MALDI MS/radionuclide detection demonstrates the ability of this hyphenated approach to work with chemically complex mass-limited samples.  相似文献   

2.
Two methods based on specific immunoaffinity enrichment followed by electrospray ionization (ESI) mass spectrometry (MS) have been developed for the specific analysis of 4-hydroxy-2-nonenal (HNE)- and malondialdehyde (MDA)-modified proteins (Michael and Schiff base adducts, respectively). Anti-HNE antibodies were immobilized on CNBr-activated sepharose, and the immunosorbent produced was used for the enrichment of HNE-adducted peptides originating from a model peptide modification and a tryptic digest of modified apomyoglobin. A further immunosorbent was produced by anti-dinitrophenyl immobilization and assayed for selective extraction of peptides modified with HNE and MDA that were initially converted to their respective hydrazones. Subsequent analysis and characterization of the different purified fractions by ESI-MS (MS/MS) revealed that the two immunosorbents enable efficient and specific enrichment of the carbonyl adducted proteins. This approach lowers substantially the detection limit of such modifications and, thus, enables better assessment and characterization of carbonyl modifications in biological and food systems.  相似文献   

3.
A novel liquid-liquid extraction (LLE) procedure was investigated for preparation of peptide and protein samples for matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). LLE using ethyl acetate as the water-immiscible organic solvent enabled segregation of hydrophobic and hydrophilic polypeptides in mixtures, thereby reducing the complexity of mass spectra obtained by MALDI MS. The LLE technique was optimized for rapid and sensitive in situ (on-target) sample preparation for MALDI MS analysis of proteins and peptides at low-picomole and subpicomole levels. Addition of MALDI matrix to the organic solvent enhanced the efficiency of the LLE-MALDI MS method for analysis of hydrophobic peptides and proteins. LLE-MALDI MS enabled the detection of the hydrophobic membrane protein bacteriorhodopsin as a component in a simple protein mixture. Peptide mixtures containing phosphorylated, glycosylated, or acylated peptides were successfully separated and analyzed by the in situ LLE-MALDI MS technique and demonstrate the potential of this method for enhanced separation and structural analysis of posttranslationally modified peptides in proteomics research.  相似文献   

4.
Monobromobimane (MBB) is a lipophilic reagent that selectively modifies free cysteine residues in proteins. Because of its lipophilic character, MBB is capable of labeling cysteine residues in membrane proteins under native conditions. Reaction of MBB with the sulfhydryl groups of free cysteines leads to formation of highly fluorescent derivatives. Here we describe a procedure for the detection and relative quantitation of MBB-labeled cysteines using fluorescence and mass spectrometric analyses, which allow determination of free cysteine content and unambiguous identification of MBB-modified cysteine residues. We have applied this approach to the analysis of the free and redox-sensitive cysteine residues of a large membrane protein, the sarcoplasmic reticulum Ca2+ release channel with a molecular mass of 2.2 million Da. Labeling was performed under physiologic conditions where the channel complex is in its native environment and is functionally active. The purified MBB-labeled channel complex was enzymatically digested, and the resulting peptides were separated by reversed-phase high-performance chromatography. MBB-labeled peptides were detected by fluorescence and identified by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. Under MALDI conditions, partial photolytic fragmentation of the MBB-peptide bound occurred, thus allowing convenient screening for the MBB-modified peptides in the MS spectrum by detection of the specific mass increment of 190.07 Da for MBB-modified cysteine residues. Modification of the peptides was further confirmed by tandem mass spectrometric analysis, utilizing sequencing information and the presence of the specific immonium ion for the MBB-modified cysteine residues at m/z 266.6. Quantitative information was obtained by comparison of both fluorescence and MS signal intensities of MBB-modified peptides. Combination of fluorescence with MS detection and analysis of MBB-labeled peptides supported by a customized software program provides a convenient method for identifying and quantifying redox-sensitive cysteines in membrane proteins of native biological systems. Identification of one redox-sensitive cysteine (2327) in the native membrane-bound sarcoplasmic reticulum Ca2+ release channel is described.  相似文献   

5.
Today, two-dimensional mass spectrometry analysis of biological tissues by means of a technique called mass imaging, mass spectrometry imaging (MSI), or imaging mass spectrometry (IMS) has found application in investigating the distribution of moleculesMSI with matrix-assisted laser desorption/ionization (MALDI) and secondary ion MS (SIMS). However, the size of the matrix crystal and the migration of analytes can decrease the spatial resolution in MALDI, and SIMS can only ionize compounds with relatively low molecular weights. To overcome these problems, we developed a nanoparticle-assisted laser desorption/ionization (nano-PALDI)-based MSI. We used nano-PALDI MSI to visualize lipids and peptides at a resolution of 15 microm in mammalian tissues.  相似文献   

6.
Chen H  He M  Pei J  He H 《Analytical chemistry》2003,75(23):6531-6535
Quantitative analyses of synthetic polymers were accomplished using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS). Many factors have hindered the development of quantitative measurement of polymers via MALDI TOF MS, e.g., laser power, matrix, cation salt, and cocrystallization. By probing the optimal conditions, two sets of polymers were studied. Fair repeatability of the samples ensures acceptable results. In set 1, two poly(ethylene glycols) with different end groups showed equal desorption/ionization efficiencies. Two synthetic polymers in set 2 with different chemical properties resulted in different MALDI responses. Good linearity was achieved by plotting the relationship between the sample concentration ratio and the total signal intensity ratio in both sets.  相似文献   

7.
Cai Y  Jiang Y  Cole RB 《Analytical chemistry》2003,75(7):1638-1644
The formation and decomposition (postsource decay, PSD) of anionic adducts in negative ion matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry have been studied. Chloride, a small inorganic anion, has been found to form stable anionic adducts with a variety of neutral oligosaccharides that can survive the MALDI process to give readily identifiable signals (with characteristic isotope patterns) allowing subpicomole detection in the best cases. The matrixes that can aid the formation of chloride adducts of oligosaccharides have gas-phase acidities lower than or close to that of HCl (1373 kJ/mol). In PSD experiments, precursor chloride adducts of oligosaccharides yield fragment ions that retain the charge on the sugar molecule rather than solely forming Cl-, and these fragments can provide structurally informative product ions. In negative ion MALDI, highly acidic oligosaccharides do not form adducts with chloride anions, but mildly acidic saccharides (e.g., containing a carboxylic acid group) form both deprotonated molecules and chloride adducts, and each may provide structural information concerning the oligosaccharide upon decomposition.  相似文献   

8.
Chen WY  Chen YC 《Analytical chemistry》2003,75(16):4223-4228
The alkali cation adductions of oligonucleotides dramatically degrade MALDI mass spectra and even affect the detection limit. Desalting is generally involved in MALDI sample preparation. This work demonstrates the feasibility of using 3,4-diaminobenzoic acid (DABA) and 3,5-DABA as the MALDI matrix for oligonucleotide analysis. Furthermore, sodium ion adducts of oligonucleotides were simultaneously reduced in the mass spectra when DABA was used as the MALDI matrix and sol-gel material was used as the sample support. However, depositing the sample on the sample support was very difficult, and the lack of homogeneity of analytes/matrix distribution on the sample support also led the analyte signals to be revealed only in "sweet spots". Alternatively, DABA was doped into sol-gel materials to generate homogeneous DABA/sol-gel hybrid film. The DABA/sol-gel hybrid film was used as the sample substrate to assist the desorption/ ionization of analytes. The analyte signals were evenly found on the sample substrate. The sodium ion adductions of oligonucleotides were also effectively suppressed. The sample preparation used in this approach resembles that used in the authors' previous study, involving sol-gel-assisted laser desorption/ionization (SGALDI) mass spectrometry (Lin, Y.-S.; Chen, Y.-C. Anal Chem. 2002, 74, 5793-5798.) The SGALDI approach was demonstrated to be effective in assisting the desorption/ionization of peptides and small proteins. Herein, the SGALDI material, DABA/sol-gel hybrid material, was successfully applied to oligonucleotide analysis, and good-quality mass spectra were obtained without extra desalting. Additionally, the presence of 0.1% SDS in the oligonucleotide sample solution was tolerated without degrading the mass spectra. The largest detectable molecular size for oligonucleotides was 72 mer. The detection limit for 24 mer of oligonucleotide was 20 fmol.  相似文献   

9.
A new sample ionization technique, atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI), was coupled with a commercial ion trap mass spectrometer. This configuration enables the application-specific selection of external atmospheric ionization sources: the electrospray/APCI (commercially available) and AP MALDI (built in-house), which can be readily interchanged within minutes. The detection limit of the novel AP MALDI/ion trap is 10-50 fmol of analyte deposited on the target surface for a four-component mixture of peptides with 800-1700 molecular weight. The possibility of peptide structural analysis by MS/MS and MS3 experiments for AP MALDI-generated ions was demonstrated for the first time.  相似文献   

10.
Zhang N  Li L 《Analytical chemistry》2002,74(7):1729-1736
Sodium dodecyl sulfate (SDS) is a strong surfactant that is widely used in protein sample preparation. While protein and peptide samples containing up to approximately 1% SDS can be analyzed by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) using a two-layer matrix/sample deposition method, the presence of SDS in a protein sample generally degrades mass resolution and mass measurement accuracy. This degradation in performance is found to be related to the formation of sodium-protein adducts in the MALDI process. If the instrument resolving power is insufficient to separate these adduct peaks from the protonated molecular ion peak, peak broadening is observed in the protein molecular ion region, and as a result, the peak centroid shifts to a higher mass. In this work, we present a method using ammonium dodecyl sulfate as a viable alternative to SDS for protein sample preparation with much improved MALDI MS performance. Three non-sodium-based dodecyl sulfate surfactants, ammonium dodecyl sulfate (ADS), hydrogen dodecyl sulfate, and tris(hydroxymethyl)aminomethane dodecyl sulfate were investigated. Of the three surfactants tested, it is found that ADS gives the best performance in MALDI. For proteins with moderate molecular masses (i.e., up to approximately 25 kDa), the presence of ADS in a protein sample does not result in significant degradation in mass resolution and accuracy, and the protonated molecular ion peak is the dominant peak in the MALDI spectrum. The ammonium adduct ions dominate the MALDI spectra when the protein mass exceeds approximately 25 kDa; however, ADS still gives better results than SDS. The behavior of ADS in gel electrophoresis was also investigated. It is shown that cell extracts dissolved in ADS can be separated by normal SDS-polyacrylamide gel electrophoresis by simply mixing them with the SDS sample buffer. The application of ADS as the surfactant for protein solubilization with improved performance in MALDI analysis is demonstrated in the study of a detergent insoluble fraction from a Raji/CD9 B-cell lymphocyte lysate.  相似文献   

11.
A streamlined protocol has been developed to accelerate, simplify, and enhance matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) of neutral underivatized glycans released from glycoproteins. It involved microwave-assisted enzymatic digestion and release of glycans, followed by rapid removal of proteins and peptides with carboxylated/oxidized diamond nanoparticles, and finally treating the analytes with NaOH before mixing them with acidic matrix (such as 2,5-dihydroxybenzoic acid) to suppress the formation of both peptide and potassiated oligosaccharide ions in MS analysis. The advantages of this protocol were demonstrated with MALDI-TOF-MS of N-linked glycans released from ovalbumin and ribonuclease B.  相似文献   

12.
Young JB  Li L 《Analytical chemistry》2007,79(15):5927-5934
An automated off-line liquid chromatography-matrix-assisted laser desorption ionization (LC-MALDI) interface capable of coupling both capillary and microbore LC separations with MALDI mass spectrometry (MS) and tandem mass spectrometry (MS/MS) has been developed. The interface is a combination of two concepts: analyte concentration from heated hanging droplets and impulse-driven droplet deposition of LC fractions onto a MALDI sample plate. At room temperature the interface allows the coupling of capillary LC separations (i.e., flow rate of <5 microL/min) with MALDI MS. With heating, it can be used to combine microbore LC operated at a relatively high flow rate of up to 50 microL/min with MALDI MS. The collected fractions can be analyzed by MALDI MS and MS/MS instruments, such as time-of-flight (TOF) and quadrupole-TOF MS. Performance of the interface was examined using several peptide and protein standards. It was shown that, using MALDI-TOF MS, [GLU1]-fibrinopeptide B could be detected with a total injection amount of 5 fmol to microbore LC. Chromatographic performance was also monitored. A peak width of 12 s at half-height for [GLU1]-fibrinopeptide B showed no evidence of band broadening due to the interface. The ability of the interface to mitigate ion suppression was studied using a mixture of 100 fmol of [GLU1]-fibrinopeptide B and 10 pmol of cytochrome c tryptic digest. Although fully suppressed under direct MALDI conditions, LC-MALDI analysis was able to detect the 100 fmol peptide with 10 s fraction collection. Finally, the ability to inject relatively large sample amounts to improve detectability of low-abundance peptides was illustrated in the analysis of phosphopeptides from alpha-casein tryptic digests. A digest loaded on column to 2.4 microg and analyzed by LC-MALDI MS/MS resulted in 82% sequence coverage and detection of all nine phosphoserine residues. It is concluded that, being able to handle both high- and low-flow LC separations, the impulse-driven heated-droplet interface provides the flexibility to carry out MALDI analysis of peptides and proteins depending on the information sought after, analysis speed, and sample size.  相似文献   

13.
Although alpha-cyano-4-hydroxycinnamic acid functions as an excellent matrix for the analysis of most peptides using matrix-assisted laser desorption/ionization time-of-flight (MALDI TOF) mass spectrometry, the ionization of phosphorylated peptides is usually suppressed by nonphosphorylated peptides. As an alternative matrix, 2',4',6'-trihydroxyacetophenone (THAP) with diammonium citrate was found to overcome this problem for the MALDI TOF mass spectrometric analysis of proteolytic digests of phosphorylated proteins. Specifically, the abundances of phosphorylated peptides in tryptic digests of bovine beta-casein and protein kinase C (PKC)-treated mouse cardiac troponin I were enhanced more than 10-fold using THAP during positive ion MALDI TOF mass spectrometry. The protonated molecules of phosphorylated peptides were sufficiently abundant that postsource decay TOF mass spectrometry was used to confirm the number of phosphate groups in each peptide. Finally, tryptic digestion followed by analysis using MALDI TOF mass spectrometry with THAP as the matrix facilitated the identification of a unique phosphorylation site in PKC-treated troponin I.  相似文献   

14.
The coupling of atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI) with Fourier transform mass spectrometry (FTMS) is described, and its significance for the high-resolution analysis of complex peptide mixtures is demonstrated. High kinetic energy and extensive metastable decay characteristic of ions generated by vacuum MALDI have been known to constitute a possible obstacle to high-resolution analysis by FTMS. Since the initial coupling of laser desorption techniques with FTMS was realized two decades ago, several different solutions have been proposed to control the energy of the ions and fulfill the promise of high sensitivity and high resolution offered by this analytical method. Initial results obtained on quadrupole time-of-flight and ion trap analyzers have shown that ions generated by MALDI at atmospheric pressure are intrinsically less energetic than those provided by vacuum MALDI. Our report indicates that this characteristic is particularly beneficial for FTMS applications in which a sharp reduction of metastable decay can make larger ion currents available for detection and possible tandem experiments. In our hands, AP MALDI-FTMS has enabled the analysis of complex peptide mixtures with resolution and accuracy comparable to those obtained by analogous electrospray ionization-FTMS experiments, with no evidence of either metastable decomposition or significant formation of matrix adducts. Analysis of a trypsin digest of bovine serum albumin provided signal-to-noise ratios and limits of detection similar to those obtained by ion trap analyzers, but with unmatched resolution and accuracy. AP MALDI has been shown to provide stable precursor ions in amounts that allowed for informative tandem experiments. Finally, the potential of AP MALDI-FTMS for the high-resolution screening of complex mixtures was demonstrated by the analysis of isobaric peptides differing in mass by less than 0.04 Da.  相似文献   

15.
Methyl- and carboxy-terminated self-assembled monolayers (SAMs) were custom-patterned on porous gold substrates with equipment commonly used to print protein arrays, without complex surface chemistry protocols. Proteins were covalently immobilized on hydrophilic carboxy-terminated SAM spots, while the remainder of the surface was superhydrophobic due to the roughened gold surface and the methyl-terminated SAM. The resistance of these patterns to biofouling and the effective containment of MALDI matrix solution within the hydrophilic spot made these surfaces amenable to analyzing protein-peptide binding with mass spectrometry. A model system of the affinity peptides HA, cmyc, and V5 and their corresponding antibodies was used to demonstrate the utility of the patterned porous gold. Mass spectrometry (MS) and tandem mass spectrometry (MS/MS) matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) spectra and images obtained reflected the effective capture of the affinity peptides directly from spiked bovine plasma.  相似文献   

16.
A novel ionization source for biological mass spectrometry is described that combines atmospheric pressure (AP) ionization and matrix-assisted laser desorption/ionization (MALDI). The transfer of the ions from the atmospheric pressure ionization region to the high vacuum is pneumatically assisted (PA) by a stream of nitrogen, hence the acronym PA-AP MALDI. PA-AP MALDI is readily interchangeable with electrospray ionization on an orthogonal acceleration time-of-flight (oaTOF) mass spectrometer. Sample preparation is identical to that for conventional vacuum MALDI and uses the same matrix compounds, such as alpha-cyano-4-hydroxycinnamic acid. The performance of this ion source on the oaTOF mass spectrometer is compared with that of conventional vacuum MALDI-TOF for the analysis of peptides. PA-AP MALDI can detect low femtomole amounts of peptides in mixtures with good signal-to-noise ratio and with less discrimination for the detection of individual peptides in a protein digest. Peptide ions produced by this method generally exhibit no metastable fragmentation, whereas an oligosaccharide ionized by PA-AP MALDI shows several structurally diagnostic fragment ions. Total sample consumption is higher for PA-AP MALDI than for vacuum MALDI, as the transfer of ions into the vacuum system is relatively inefficient. This ionization method is able to produce protonated molecular ions for small proteins such as insulin, but these tend to form clusters with the matrix material. Limitations of the oaTOF mass spectrometer for singly charged high-mass ions make it difficult to evaluate the ionization of larger proteins.  相似文献   

17.
The peptide content of individual mammalian cells is profiled using matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. Both enzymatic and nonenzymatic procedures, including a glycerol cell stabilization method, are reported for the isolation of individual mammalian cells in a manner compatible with MALDI MS measurements. Guided microdeposition of MALDI matrix allows samples to be created with suitable analyte-to-matrix ratios. More than 15 peptides are observed in individual rat intermediate pituitary cells. The combination of accurate mass data, expected cleavages by proteolytic enzymes, and postsource decay sequencing allows identification of 14 of these peptides as pro-opiomelanocortin prohormone-derived molecules. These protocols permit the classification of individual mammalian cells by peptide profile, the elucidation of cell-specific prohormone processing, and the discovery of new signaling peptides on a cell-to-cell basis in a wide variety of mammalian cell types.  相似文献   

18.
A matrix-assisted laser desorption/ionization (MALDI) ion trap mass spectrometer of new design is described. The instrument is based on a commercial Finnegan LCQ ion trap mass spectrometer to which we have added a MALDI ion source that incorporates a sample stage constructed from a compact disk and a new ion transmission interface. The ion interface contains a quadrupole ion guide installed between the skimmer and the octapoles of the original instrument configuration, allowing for operation in both MALDI and electrospray ionization modes. The instrument has femtomole sensitivity for peptides and is capable of collecting a large number of MALDI MS and MALDI MS/MS spectra within a short period of time. The MALDI source produces reproducible signals for 10(4)-10(5) laser pulses, enabling us to collect MS/MS spectra from all the discernible singly charged ions detected in a MS peptide map. We describe the different modes of the instrument operation and algorithms for data processing as applied to challenging protein identification problems.  相似文献   

19.
A mini ball mill (MBM) solvent-free matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) method allows for the analysis of bacteriorhodopsin (BR), an integral membrane protein that previously presented special analytical problems. For well-defined signals in the molecular ion region of the analytes, a desalting procedure of the MBM sample directly on the MALDI target plate was used to reduce adduction by sodium and other cations that are normally attendant with hydrophobic peptides and proteins as a result of the sample preparation procedure. Mass analysis of the intact hydrophobic protein and the few hydrophobic and hydrophilic tryptic peptides available in the digest is demonstrated with this robust new approach. MS and MS/MS spectra of BR tryptic peptides and intact protein were generally superior to the traditional solvent-based method using the desalted "dry" MALDI preparation procedure. The solvent-free method expands the range of peptides that can be effectively analyzed by MALDI-MS to those that are hydrophobic and solubility-limited.  相似文献   

20.
Lipids exhibit a broad range of chemical properties that make their analysis quite demanding. Today, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) represents a versatile tool in the field of lipid analysis, also offering the possibility for molecular structural identification using novel MALDI tandem time-of-flight (TOF/TOF) instrumentation. In this study, we evaluated 2,4,6-trihydroxyacetophenone (THAP) for the analysis of various lipid classes including neutral storage lipids (triacylglycerols), polar membrane lipids (glycerophospho- and sphingolipids), and glycosphingolipids. THAP proved to be a versatile matrix for the routine analysis of various lipids from biological samples ("lipidomics"). A sample preparation methodology was established using selective alkali salt doping for subsequent MS/MS experiments. Sodiated and lithiated molecules provided superior structural information on lipids (i.e., acyl group identification); thus, following this approach, both selective peak detection with high sensitivity and more reliable structural information were obtained simultaneously.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏