首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Applied Thermal Engineering》2002,22(14):1661-1672
This work reports the results of an experimental study on concentric capillary tube–suction line heat exchangers commonly used as expansion devices in household refrigerators and freezers. Heat exchanger performance (mass flow rate and suction line outlet temperature) with the hydrocarbon HC-600a was experimentally evaluated for a range of heat exchanger geometries and operating conditions. The tests were planned and performed following a statistically based methodology. Based on the resulting database empirical correlations were developed to predict the refrigerant mass flow rate and the suction line outlet temperature.  相似文献   

2.
Capillary tube suction line heat exchangers have been modeled using both numerical and analytical approaches. The former requires a reasonable understanding of the governing heat and fluid flow equations, thermodynamic relations, numerical methods, and computer programming, and therefore are not suitable for most refrigeration and air-conditioning practitioners. Alternatively, empirical algebraic formulations for diabatic capillary tube flows have been proposed in the literature, in spite of their lack of generality and accuracy. This paper introduces a physically consistent, unconditionally convergent, easy-to-implement semi-empirical algebraic model for capillary tube suction line heat exchangers, with the same level of accuracy as found with more sophisticated first-principles models. The methodology treats the refrigerant flow and the heat transfer as independent phenomena, thus allowing the derivation of explicit algebraic expressions for the refrigerant mass flow rate and the heat exchanger effectiveness. The thermal and hydraulic models are then conflated through the so-called Buckingham-π theorem using in-house experimental data collected for diabatic capillary tube flows of refrigerants HFC-134a and HC-600a. Comparisons between the model predictions and the experimental data revealed that more than 90% and nearly 100% of all data can be predicted within ±10% and ±15% error bands, respectively.  相似文献   

3.
《Applied Thermal Engineering》2002,22(16):1801-1819
This paper presents a homogeneous model of refrigerant flow through capillary tube–suction line heat exchangers, which are widely used in small vapour compression refrigeration systems. The homogeneous model is based on fundamental conservation equations of mass, momentum and energy. These equations are solved simultaneously through iterative process. Churchill’s correlation [3] is used to calculate single-phase friction factors and Lin et al. [6] correlation for two-phase friction factors. The single-phase heat transfer coefficient is calculated by Gnielinski’s equation [5] while two-phase flow heat transfer coefficient is assumed to be infinite. The model is validated with previous experimental and analytical results. The present model can be used in either design calculation (calculate the capillary tube length for given refrigerant mass flow rate) or simulation calculation (calculate the refrigerant mass flow rate for given capillary tube length). The simulation model is used to understand the refrigerant flow behaviour inside the non-adiabatic capillary tubes.  相似文献   

4.
A numerical simulation model for lateral capillary tube-suction line heat exchangers is presented here to analyze its performance characteristics in small vapour compression refrigeration systems (e.g. domestic refrigerators). Appropriate heat transfer correlations have been used to illustrate the reverse heat transfer and re-condensation phenomena inside the tubes. Some convergence problems were encountered during the execution of the model when lower vapour temperature inside the suction line caused the two-phase refrigerant inside the capillary tube to re-condense within the heat exchange region. Therefore, a relationship between the re-condensation phenomenon and the divergence problem has been analyzed in the paper. The modelling was performed with two refrigerants, namely HFC-134a and HC-600a. Further, a simple theoretical equation has been developed to express the re-condensation phenomenon in non-adiabatic capillary tubes.  相似文献   

5.
Yat Yau  Hong Poh 《传热工程》2019,40(7):574-587
The present research is to develop a homogenous mathematical model to simulate capillary tube-suction line heat exchanger (CT-SL HX) based on the fundamentals of conservations of mass, momentum and energy with comprehensive experimental result validations. The computer model is fully validated by 72 experimental data with error bands of ±15%, ±2°C and ±35% on the mass flow rate prediction, the suction pipe outlet temperature, and the heat exchange estimation respectively. The results suggest that the internal diameter of the capillary tube, and the heat-transfer length of the CT-SL HX have demonstrated an apparent impact on the capillary tube outlet conditions and heat transfer across the segment.  相似文献   

6.
In the present work, a homogenous model including the metastable liquid region has been developed for the adiabatic flow of refrigerant through the spiral capillary tube. In order to develop the model, both liquid region and two phase region have been discretized into infinitesimal segments to take into account the effect of varying radius of curvature of spiral tube on the friction factor. The effect of the pitch of spiral on the mass flow rate of refrigerant and capillary tube length has been investigated. A comparison of flow characteristics of refrigerant R22 and its alternatives, i.e., R407C and R410A has been made at different operating conditions at the inlet of the capillary tube and it has been found that the flow characteristics of R22 and R407C are almost similar for a given condenser pressure and degree of subcooling at the inlet of capillary tube.  相似文献   

7.
This work presents a numerical model to simulate steady state refrigerant flow along capillary tube-suction line heat exchangers, commonly used in small refrigeration systems. The flow along the straight and horizontal capillary tube is divided into two regions: a single-phase and a two-phase flow region. The flow is taken as one-dimensional and the metastable flow phenomenon is neglected. The two-fluid model is employed for the two-phase flow region, considering the hydrodynamic and the thermodynamic non-equilibrium between the liquid and vapor phases. Comparisons are made with experimental measurements of the mass flow rate and temperature distribution along capillary tube-suction line heat exchangers working with refrigerant R134a in different operating conditions. The results indicate that the present model provides a good estimation of the refrigerant mass flow rate. Moreover, comparisons with a homogeneous model are also made. Some computational results referring to the quality, void fraction and velocities of each phase are also presented and discussed.  相似文献   

8.
An unfavorable effect of gas impurities on the throttling process inside a small-diameter tube, i.e. a capillary tube, has been studied in detail. A special testing capillary tube equipped with precise temperature and pressure sensors has been used for an experimental investigation of the capillary flow of a saturated fluorocarbon refrigerant, R218, contaminated by dissolved nitrogen. The gas impurities significantly affected the throttling process, since the two-phase flow started notably earlier than in the case of pure refrigerant flow. Moreover, the gas contamination resulted in a decreased mass flow rate of refrigerant delivered through the capillary tube. A comprehensive numerical model has been developed to simulate the capillary flow of gas-contaminated refrigerant. The model takes into account two coincident thermodynamic events: the throttling process of the refrigerant (solvent) and the gradual release of the dissolved gas impurities (solute) from the refrigerant liquid phase. The gas release is in principle described by using the temperature correlation of the Henry’s law constant. The model considers adiabatic, thermodynamically equilibrated capillary flow with homogeneous two-phase flow. The numerical simulation is in good agreement with our experimental data measured for R218 contaminated by nitrogen.  相似文献   

9.
随着热泵空调的普及,热泵空调的能耗占比不断增大,其节能问题成为了关注焦点。换热器对系统性能有着重要的影响,如何通过改进换热器来提升系统性能则成为了研究的热点。其中分液冷凝器作为一种新型的换热设备,能对系统制冷性能产生积极影响。但热泵空调系统在制热工况下,分液冷凝器变成气液分离式蒸发器,其系统制热性能尚未可知。通过实验研究,调整毛细管长度和制冷剂充注量,发现在国家标准工况下分液热泵空调系统的最大制热量比原系统高4.50%,C OP比原系统高7.93%,所对应的毛细管长度为700 mm,制冷剂充注量为700 g。且制冷剂过充注的情况下,分液热泵空调系统的制热性能比较稳定。  相似文献   

10.
《Energy》1999,24(3):247-259
Two-phase flow of pure chlorofluorocarbon (CFC) refrigerants in solar collector tubes has been examined in previous studies in connection with applications in direct-expansion, solar-assisted heat pumps (DX-SAHP). The present work extends the thermodynamic analysis of solar collectors to the multicomponent and multiphase domain to cover newly proposed refrigerant mixtures which are potential candidates for replacing CFCs in future DX-SAHP systems. A computational methodology is developed to determine the size of a solar collector of a DX-SAHP that uses a binary refrigerant mixture whose thermodynamic and transport properties are predicted from a computer code. The energy equation for the elemental collector tube control volume, incorporating the local thermodynamic and heat transfer characteristics, is integrated to determine the tube length for a given set of inlet and exit thermodynamic states of the refrigerant mixture. Effects of various parameters such as the collector mass-flow rate and operating pressure, tube diameter and absorbed solar radiation on the collector tube length, heat transfer coefficient, and the local refrigerant temperature in the tube are also considered.  相似文献   

11.
This paper presents a numerical investigation of the flow characteristics of helical capillary tubes compared with straight capillary tubes. The homogenous two-phase flow model developed is based on the conservation of mass, energy, and momentum of the fluids in the capillary tube. This model is validated by comparing it with the experimental data of both straight and helical capillary tubes. Comparisons of the predicted results between the straight and helical capillary tubes are presented, together with the experimental results for straight capillary tubes obtained by previous researchers. The results show that the refrigerant flowing through the straight capillary tube provides a slightly lower pressure drop than that in the helical capillary tube, which resulted in a total tube length that was longer by about 20%. In addition, for the same tube length, the mass flow rate in the helical capillary tube with a coil diameter of 40 mm is 9% less than that in the straight tube. Finally, the results obtained from the present model show reasonable agreement with the experimental data of helical capillary tubes and can also be applied to predict the flow characteristics of straight capillary tubes by changing to straight tube friction factors, for which Churchill's equation was used in the present study.  相似文献   

12.
This paper analyzes the heat transfer and pressure drop characteristics of a tube–fin heat exchanger in ice slurry HVAC system. Ice slurry is a suspension of crystallized water based - ice solution with a freezing point depressant like ethylene glycol. The ice- slurry is pumpable, hence it is also called pumpable ice. The composition of ice slurry considered for analysis is 14% ice fraction, 16% ethylene glycol, and 70% water by volume. It is deduced that the ice slurry HVAC system results in 7.4% increase in temperature drop over the conventional chilled water system The latent heat absorbed by ice slurry on melting makes it an attractive choice for achieving high degree of cooling. The numerical analysis was conducted by simulating the ice slurry tube flow region and air flow region of tube–fin heat exchanger in the air-handling unit of HVAC system. For the simulation six different louver patterns with 10 to 55 louver angle were considered. The design of the tube–fin heat exchanger for optimal heat transfer and pressure drop characteristics was also determined with the optimization parameter like louver angle, fin pitch, and ice slurry flow velocity.  相似文献   

13.
A mathematical model is developed to study flow characteristics in non-adiabatic capillary tubes. The theoretical model is based on conservation of mass, energy and momentum of fluids in the capillary tube and suction line. The mathematical model is categorized into three different cases, depending on the position of the heat exchange process. The first case is considered when the heat exchange process starts in the single-phase flow region, the second case is determined when the heat exchange process starts at the end of the single-phase flow region, and the last case is considered when the heat exchange process takes place in the two-phase flow region. A set of differential equations is solved by the explicit method of finite-difference scheme. The model is validated by comparing with the experimental data obtained from previous works. The results obtained from the present model show reasonable agreement with the experimental data. The present non-adiabatic capillary tube model can be used to integrate with system models working with alternative refrigerants for design and optimization.  相似文献   

14.
In this paper, a novel bayonet tube high temperature heat exchanger (HTHE) with inner and outer fins is presented. It can be used in the ultra high temperature environment, such as hydrogen production, very high temperature reactor and externally fired combined cycle. Numerical investigation of heat transfer performance on the inside of bayonet element has been conducted for structure design. The numerical results suggest that the inner fin and inner tube should not be welded together. It is recommended that the air enters from the inner tube and exits from the annular space in the high temperature zone. A high temperature experimental system has been established to test the heat transfer and pressure drop characteristics of the HTHE. The surface area density of the tested HTHE is 6 times higher than that of the bare bayonet tube heat exchanger. The experimental results indicate that the mass flow rate on both sides and inlet temperature on the fuel gas side have a significant effect on the heat transfer rate and effectiveness, while the pressure drop ratios are mainly affected by the mass flow rate rather than the inlet temperature. Comparison between the tested HTHE and the similar HTHE without fins indicates that the proposed HTHE has a significant potential to improve the comprehensive heat transfer performance.  相似文献   

15.
A capillary tube‐based CO2 heat pump is unique because of the transcritical nature of the system. The transcritical cycle has two independent parameters, pressure and temperature, unlike the subcritical cycle. A comparative study for various operating conditions, based on system COP and exergetic efficiency, of a capillary tube and a controllable expansion valve‐based transcritical carbon dioxide heat pump systems for simultaneous heating and cooling at 73 and 4°C, respectively, is presented here. Two optimized capillary tubes having diameter of 1.5 and 1.6 mm are compared with an equivalent controllable throttle valve. Heat transfer and fluid flow effects are included in the gas cooler and evaporator model and capillary tube employs the homogeneous flow model to simulate two‐phase flow. Subcritical and supercritical thermodynamic and transport properties of CO2 are calculated employing a precision in‐house property code. Optimization of effective distribution of total heat exchanger area ratio between gas cooler and evaporator is investigated. The exergetic efficiency is better in case of the capillary tube than that of a controllable throttle valve‐based system. Capillary tube‐based system is shown to be quite flexible regarding changes in ambient temperature, almost behaving to offer an optimal pressure control just like the controllable expansion valve yielding both, maximum system COP and maximum exergetic efficiency. Relatively at a smaller diameter, the capillary tube exhibits better exergetic efficiency. Capillary tube length is the critical parameter that influences system optimum conditions. The exergy flow diagram exhibits that compressor, gas cooler and capillary tube contribute a larger share, in that order, to system irreversibility. It is fairly established in this study that a capillary tube can be a good engineering option for small capacity systems in lieu of an expansion valve, which has been thought of as the only possible solution to attain the pressure optimization, an important feature of all transcritical CO2 systems. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
Subcooled flow boiling heat transfer characteristics of refrigerant R-134a in a vertical plate heat exchanger (PHE) are investigated experimentally in this study. Besides, the associated bubble characteristics are also inspected by visualizing the boiling flow in the vertical PHE. In the experiment two vertical counterflow channels are formed in the exchanger by three plates of commercial geometry with a corrugated sinusoidal shape of a chevron angle of 60°. Upflow boiling of subcooled refrigerant R-134a in one channel receives heat from the downflow of hot water in the other channel. The effects of the boiling heat flux, refrigerant mass flux, system pressure and inlet subcooling of R-134a on the subcooled boiling heat transfer are explored in detail. The results are presented in terms of the boiling curves and heat transfer coefficients. The measured data showed that the slopes of the boiling curves change significantly during the onset of nucleate boiling (ONB) especially at low mass flux and high saturation temperature. Besides, the boiling hysteresis is significant at a low refrigerant mass flux. The subcooled boiling heat transfer coefficient is affected noticeably by the mass flux of the refrigerant. However, increases in the inlet subcooling and saturation temperature only show slight improvement on the boiling heat transfer coefficient.The photos from the flow visualization reveal that at higher imposed heat flux the plate surface is covered with more bubbles and the bubble generation frequency is substantially higher, and the bubbles tend to coalesce to form big bubbles. But these big bubbles are prone to breaking up into small bubbles as they move over the corrugated plate, producing strong agitating flow motion and hence enhancing the boiling heat transfer. We also note that the bubbles nucleated from the plate are suppressed to a larger degree for higher inlet subcooling and mass flux. Finally, empirical correlations are proposed to correlate the present data for the heat transfer coefficient and the bubble departure diameter in terms of boiling, Froude, Reynolds and Jakob numbers.  相似文献   

17.
This paper describes an experimental and theoretical analysis of the combined heat and mass transfer processes that take place in the absorber of vapor absorption cooling systems. The effect of the main operating variables such as solution inlet temperature, solution flow rate, coolant inlet temperature, coolant flow rate and absorber vapor pressure on the performance of absorber is experimentally investigated. A mathematical model that takes account of the geometrical details of the solution and coolant flow is developed following the traditional heat exchanger analysis to obtain additional information on the performance of the absorber. The governing equations are solved analytically using Laplace Transformation technique. The variations of the concentration of solution and the temperature of the coolant and solution after each horizontal tube are analyzed. There is satisfactory agreement between the predictions of the analytical model and the experimental results. The serpentine arrangement of the coolant flow in the absorber tubes results in a temperature and concentration variation of the solution mainly along the height of the absorber.  相似文献   

18.
Analytical analysis of unbalanced heat exchangers is carried out to study the second law thermodynamic performance parameter through second law efficiency by varying length‐to‐diameter ratio for counter flow and parallel flow configurations. In a single closed form expression, three important irreversibilities occurring in the heat exchangers—namely, due to heat transfer, pressure drop, and imbalance between the mass flow streams—are considered, which is not possible in first law thermodynamic analysis. The study is carried out by giving special influence to geometric characteristics like tube length‐to‐diameter dimensions; working conditions like changing heat capacity ratio, changing the value of maximum heat capacity rate on the hot stream and cold stream separately and fluid flow type, i.e., laminar and turbulent flows for a fully developed condition. Further, second law efficiency analysis is carried out for condenser and evaporator heat exchangers by varying the effectiveness and number of heat transfer units for different values of inlet temperature to reference the temperature ratio by considering heat transfer irreversibility. Optimum heat exchanger geometrical dimensions, namely length‐to‐diameter ratio can be obtained from the second law analysis corresponding to lower total entropy generation and higher second law efficiency. Second law analysis incorporates all the heat exchanger irreversibilities. © 2013 Wiley Periodicals, Inc. Heat Trans Asian Res; Published online in Wiley Online Library ( wileyonlinelibrary.com/journal/htj ). DOI 10.1002/htj.21109  相似文献   

19.
Design criteria for tube bundle heat exchangers, to avoid fluidelastic instability, are based on stability criteria for ideal bundles and uniform flow conditions along the tube length. In real heat exchangers, a non-uniform flow distribution is caused by inlet nozzles, impingement plates, baffles and bypass gaps. The calculation of the equivalent velocities, according to the extended stability equation of Connors, requires the knowledge of the mode shape and the assumption of a realistic velocity distribution in each flow section of the heat exchanger. It is the object of this investigation to derive simple correlations and recommendations, (1) for equivalent velocity distributions, based on partial constant velocities, and (2) for the calculation of the critical volume flow in practical design applications. With computational fluid dynamic (CFD) programs it is possible to calculate the velocity distribution in real tube bundles, and to determine the most endangered tube and thereby the critical volume flow. The paper moreover presents results and design equations for the inlet section of heat exchangers with variations of a broad range of geometrical parameters, e.g., tube pitch, shell diameter, nozzle diameter, span width, distance between nozzle exit and tube bundle.  相似文献   

20.
《Applied Thermal Engineering》2003,23(12):1503-1514
The performance of a refrigerating system with an environment-friendly refrigerant, propane (R-290) as the refrigerant, was experimentally studied. There were two evaporators connected in series within the system under study.The results show that with both lengths of the two capillary tubes fixed, both the mass flow rate of the refrigerant and the suction pressure of the system increase with the condensing pressure. In addition, the cooling capacity of the high-temperature evaporator decreases, but that of the low-temperature evaporator increases. As the condensing pressure is fixed and the length of the capillary tube for the high-temperature evaporator is increased while that for the low-temperature evaporator is fixed, the cooling capacity of the high-temperature evaporator increases while that of the low-temperature evaporator decreases. On the other hand, as the capillary tube for the low-temperature evaporator is lengthened while that for the high-temperature evaporator is fixed, the variations in the cooling capacity of these two evaporators reverse. The enthalpy changes of the refrigerant within the evaporators are strongly affected by the length of the high-temperature capillary tube, while the evaporating pressures are influenced mainly by the length of the low-temperature capillary tube.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏