首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
M. Ciampi  F. Leccese  G. Tuoni   《Solar Energy》2003,75(6):491-502
The use of ventilated facades and roofs can help to reduce summer thermal loads and, therefore, the energy consumption due to air-conditioning systems. This paper discusses a simple analytical method for the calculation of the energy saving achievable by using ventilated facades in which the air flow inside the air duct is due to stack effect. Two particular cases of outstanding importance are investigated. The first in which the inner masonry wall is given, and the air duct and the outer facing have to be optimized. The second in which the outer facing is given, and the inner masonry wall and the air duct have to be optimized. The first case can occur in existing buildings renovation, while the second case can occur during the design process. Finally, the influence of the variation of some quantities necessary for calculation on the energy performance of ventilated facades is investigated. In particular, the energy performance of such facades results to be strongly influenced by the air duct width, the insulating material distribution, the solar radiation intensity, the wall outer surface thermal resistance and the roughness of the slabs delimiting the air duct.  相似文献   

2.
ABSTRACT

Conventional passive solar systems can significantly reduce a building's heating load. However, the integration of passive heating and cooling systems in the same building and the benefits of actively controlling passive systems has largely been unexplored. The objective of this study was to determine the relative performance of a passive solar heating and sky cooling system operating with a range of control strategies, with the goal of minimising the overall annual energy use for space conditioning. A combined system (CS) and a separate system (SS) were simulated with thermal networks using MATLAB, with weather data for Louisville, KY. The control strategies simulated included: Seasonal, Ambient, Room and Matrix. The highest fraction of energy supplied by ambient sources for the SS was 0.707 with Matrix control, while for the CS, the highest fraction (0.704) was with Matrix temperature control with switchable attributes for heating and cooling.  相似文献   

3.
This paper deals with the experimental investigation and analysis of the energy and environmental performance of a green roof system installed in a nursery school building in Athens. The investigation was implemented in two phases. During the first phase, an experimental investigation of the green roof system efficiency was presented and analysed, while in the second one the energy savings was examined through a mathematical approach by calculating both the cooling and heating load for the summer and winter period for the whole building as well as for its top floor. The energy performance evaluation showed a significant reduction of the building's cooling load during summer. This reduction varied for the whole building in the range of 6–49% and for its last floor in the range of 12–87%. Moreover, the influence of the green roof system in the building's heating load was found insignificant, and this can be regarded a great advantage of the system as any interference in the building shell for the reduction of cooling load leads usually to the increase of its heating load.  相似文献   

4.
The concepts of the energy saving equivalent (ESE) and energy saving index (ESI) are presented in this paper to evaluate the performance of new materials and components in passive buildings. The ESE represents the hypothetical energy that should be input to maintain a passive room at the same thermal state as that when a particular material or component is adopted. The ESI is the ratio of a particular material or component's energy saving equivalent to the corresponding value of the ideal material or component that can maintain the room at an ideal thermal state in passive mode. The former can be used to estimate the effect of the adoption of a certain building component or material on the building's thermal state from an energy standpoint, while the latter can be used to characterize the performance of the actual building component or material from a common standpoint and be used to evaluate the performance of components or materials in different climatic regions or under different operating situations. In this study, the ESI was used to evaluate the performance of a thermochromic window, represented by a single vanadium dioxide (VO2) glazing, in passive residential buildings in three climatic regions of China (cold zone, hot summer and cold winter zone, and hot summer and warm winter zone).  相似文献   

5.
The quasi-steady-state analysis of a hostel building for semiarid climatic conditions has been presented by incorporating the effectiveness of various cooling approaches in the analysis. The effect of intermittent use of an exhaust chimney, opening of windows and a desert cooler has also been incorporated in the analysis to study its performance. It is observed that there is an appreciable reduction in the room temperature by intermittent use of various cooling approaches.  相似文献   

6.
This paper presents the modeling and simulation of an earth air heat exchanger (EAHE), employed as an air-conditioning device for buildings in the climate conditions of the south of Algeria. The earth tubes buried in the ground can offer considerable advantages in terms of energy savings. The appropriate depth of the buried tubes was calculated taking into account the physical properties of the soil in the region under study and using a specific program developed by the authors. A parametric analysis was carried out taking into account the length and the radius of the pipe and the velocity of the air in the pipe. The results of performance and overall energy savings are presented. The maximum daily cooling capacity of the EAHE studied was 1.755 kWh. Results showed that a simple EAHE system can provide 246.815 kWh in a period of one year.  相似文献   

7.
Cooling demand in the building sector is growing rapidly; thermal energy storage systems using phase change materials (PCM) can be a very useful way to improve the building thermal performance. This work shows the benefits of PCM when incorporated in wood fiber-polymer composite as floor cooling system using nano-encapsulated PCMs. The wood-plastic-NPCM composites were produced using compression molding process and its mechanical and thermal properties were investigated. Two dynamic simulators were employed to investigate synthesized composites thermal performance. Increasing NPCM content in WPC showed that the fluctuations of the simulator temperature was decreased while the heat fluxes through the floor was increased. The variations of ambient maximum temperature have little effect on the air temperature of the simulator with 40% PCM which indicates that the amount of PCM was enough for studied environmental condition. Field experiments were performed using two medium-scale test houses located on Tehran-Iran. It can be concluded that using NPCM helps to reduce heating and cooling demand. Moreover, the natural night ventilation by opening windows reduced the number of hours that the temperature is above 23°C from 499 h/year in case1 (without opening) to 255 h/year in case 2(with opening). This means that natural night ventilation could help reduce the overheating period to about 50% with the use of NPCM.  相似文献   

8.
By proper passive design concepts which essentially consist of collection, storage, distribution, and control of thermal energy flow, an energy saving of 2.35% of the world energy output is possible. The basic methods of heating and cooling of buildings are solar radiation, outgoing longwave radiation, water evaporation, and nocturnal radiation cooling. A Trombe-Michel wall consists of a large concrete mass, exposed to sunlight through large, south-facing windows; it is used for heating buildings. Solar absorption cooling and solar dehumidification and evaporative cooling are two approaches that utilize solar energy for the generation of the working fluid and the cooling of dwellings. Outgoing longwave radiation is the most practical way of cooling buildings in desert climates and is effective on roof surfaces, emitting the radiations from the surface of earth to the atmosphere and to outer space. Water evaporation in desert coolers is the usual method of cooling in arid regions. Nocturnal radiation both heats in winter and cools in summer, in suitable climates, and does so with no nonrenewable energy other than a negligible amount required to move the insulation twice a day. The study of 24 different locations in Libya divides the country into regions with distinct passive strategies. The northern region and the Mediterranean coast need passive heating. The buildings in this region should restrict conductive heat flow, prevent infiltration and promote solar heat gains. The southern region, a part of the Sahara desert, needs passive cooling. The buildings in this region need high thermal mass and should promote natural ventilation, restrict solar heat gains and encourage evaporative and radiant cooling. The difficulties encountered in passive solar design are the large exposed area required with suitable orientation for the collection of energy and the large space requirement for the storage of thermal energy. This paper reviews these passive systems and discusses suitable strategies to be adopted for Libya.  相似文献   

9.
Viorel Badescu   《Renewable Energy》2007,32(5):845-855
This paper develops previous research on passive house (PH) space heating. A simple and accurate ground heat exchanger model is developed. It is based on a numerical transient bi-dimensional approach that allows to computing the ground temperature at the surface and at various depths. The new model was integrated into the existing theoretical approach and implemented within the computer code used to simulate the heating system operation in Pirmasens PH (Rhineland Palatinate, Germany). The heating and cooling potential of the system under real climatic conditions was investigated. The energy delivered by the ground heat exchanger depends significantly on different design parameters like pipe's depth, diameter and material.  相似文献   

10.
In hot climate, phase change material (PCM) can be incorporated into building envelopes to reduce heat gain through the building envelopes and therefore reduce its cooling demand. In this study, the energy performance of building envelopes integrated with PCM has been explored using a popular dynamic building performance simulation package, EnergyPlus, and the energy saving mechanism of PCM was investigated. The simulation results reflected that PCM could effectively help to reduce the building's annual energy consumption by 20.9% for Guangzhou, China. In addition, for the Guangzhou city, 27°C transition temperature, smaller thermal conductivity of roof, and higher amount of PCM can all help to improve the building's energy performance. Additionally, it is suggested that in real building development/retrofit projects, the selection of PCM needs to be based on both their thermal properties and the local climatic conditions of the building.  相似文献   

11.
The goal of the present study is to validate the cooling performance of a ground-coupled heat pump system established in Fırat University, Elazığ (38.41°N, 39.14°E), Turkey. The cooling load of the test room was 3.1 kW at design conditions. The experimental results were obtained from June to September in cooling season of 2003. The ground heat exchanger was used, and it was buried with in 2 m depth trench. The average cooling performance coefficient of the system (COPoverall) was obtained to be 2.01. The results obtained from experimental measurement showed that these systems could be used safely, reliably and efficiently at the lowest possible cost for Elazığ, Turkey climatic conditions. Especially, the seasonal energy efficiency ratio (SEER) of this system is moderate at longer-term testing.  相似文献   

12.
S.S. Chandel  R.K. Aggarwal   《Renewable Energy》2008,33(10):2166-2173
Under the Passive Solar Building Programme, more than 100 buildings have been constructed in the high altitude region of the Indian State of Himachal Pradesh. A policy decision has been taken by the State that all government/semi-government buildings are to be designed and constructed as per passive solar housing technology. The evaluation studies of some of these buildings have been carried out by our group. In the present study, the thermal performance of a passive solar bank building at Shimla, has been evaluated. This solar building incorporates a heat-collecting wall and a roof-top solar air heater with an electric heating backup, sunspaces and double-glazed windows. The monitoring of the building shows that the solar passive features in the building results in comfortable living conditions. The study shows that the high cost central electric/gas/wood-fired heating systems can be replaced by a low cost solar heating system with backup heaters. This will result not only in reducing higher installation costs of these systems but also the annual running and maintenance costs. It is shown that the solar passive features save electricity required for space heating and reduce the heat losses in the building by about 35%. The strategy to be followed for the propagation of passive solar technology on large scale in this Himalayan State or in any other cold hilly region is also presented.  相似文献   

13.
Thermal performance of two phase change material (PCM) composites, mixed type PCM-gypsum and shape-stabilized PCM plates, has been numerically evaluated in a passive solar building in Beijing with an enthalpy model. Effects of the melting temperature and phase transition zone of the PCM are analyzed and a comparison between the two types of PCM composites is performed. The results show that: (1) for the present conditions, the optimal melting temperature is about 21 °C; (2) PCM composites with a narrow phase transition zone provide better thermal performance; (3) both mixed type PCM-gypsum and shape-stabilized PCM plates effectively shave the indoor temperature swing by 46% and 56%, respectively; (4) the shape-stabilized phase change material (SSPCM) plates respond more rapidly than the mixed type PCM-gypsum and prove to be thermally more effective in terms of utilizing the latent heat.  相似文献   

14.
Thermal performance of a hybrid space-cooling system with night ventilation and thermal storage using shape-stabilized phase change material (SSPCM) is investigated numerically. A south-facing room of an office building in Beijing is analyzed, which includes SSPCM plates as the inner linings of walls and the ceiling. Natural cool energy is charged to SSPCM plates by night ventilation with air change per hour (ACH) of 40 h−1 and is discharged to room environment during daytime. Additional cool-supply is provided by an active system during office hours (8:00-18:00) necessary to keep the maximum indoor air temperature below 28 °C. Unsteady simulation is carried out using a verified enthalpy model, with a time period covering the whole summer season. The results indicate that the thermal-storage effect of SSPCM plates combined with night ventilation could improve the indoor thermal-comfort level and save 76% of daytime cooling energy consumption (compared with the case without SSPCM and night ventilation) in summer in Beijing. The electrical COPs of night ventilation (the reduced cooling energy divided by fan power) are 7.5 and 6.5 for cases with and without SSPCM, respectively.  相似文献   

15.
The common system used for thermal regulation in mosques of United Arab Emirates (UAE) is the heating, ventilating and air-conditioning (HVAC) system. This system increases demands on energy consumption and increases CO2 emission. A passive design approach is one of the measures to reduce these problems. This study involved an analytical examination of building forms, followed by testing the impact of these forms on its thermal performance and indoor thermal comfort. The tests were conducted using energy simulations software packages. Passive parameters such as shading devices, thermal insulation and natural ventilation were applied in six cases, including the baseline case within each form. The obtained results showed a significant effect of mosque forms as well as passive design techniques on the thermal comfort within the structures. The findings confirmed that the use of passive design alone would not help achieve thermal comfort, but reduce the annual energy consumption by10%. By integrating a hybrid air-conditioning system as another supporting approach, the annual energy consumption could be reduced by 67.5%, which allows for the designing of a much smaller HVAC system.  相似文献   

16.
A single-storey office building in a hot and dry climate is modelled for evaporative cooling. The counterflow cooling tower is modified to precool the tower inlet air by the tower exit air in a heat exchanger. Centralized evaporative air cooling, using the modified cooling tower, and roof evaporative cooling are considered to provide comfortable living conditions in the space. The thermal performance of such a building is analysed for various operating parameters. The study indicates that centralized evaporative air cooling is feasible, to maintain near-perfect comfort conditions in hot and dry climates. Modified cooling tower and roof evaporative cooling further enhance the scope of evaporative cooling for comfort applications.  相似文献   

17.
Lightweight envelopes are widely used in modern buildings but they lack sufficient thermal capacity for passive solar utilization. An attractive solution to increase the building thermal capacity is to incorporate phase change material (PCM) into the building envelope. In this paper, a simplified theoretical model is established to optimize an interior PCM for energy storage in a lightweight passive solar room. Analytical equations are presented to calculate the optimal phase change temperature and the total amount of latent heat capacity and to estimate the benefit of the interior PCM for energy storage. Further, as an example, the analytical optimization is applied to the interior PCM panels in a direct-gain room with realistic outdoor climatic conditions of Beijing. The analytical results agree well with the numerical results. The analytical results show that: (1) the optimal phase change temperature depends on the average indoor air temperature and the radiation absorbed by the PCM panels; (2) the interior PCM has little effect on average indoor air temperature; and (3) the amplitude of the indoor air temperature fluctuation depends on the product of surface heat transfer coefficient hin and area A of the PCM panels in a lightweight passive solar room.  相似文献   

18.
This communication presents design considerations and thermal performance of a hostel building (using passive techniques) for a composite climatic condition of Delhi, India. The place experiences three definite seasons: hot-dry early summer, warm-humid late summer (monsoon period) and cold-dry period in winter. The design meets the demand of cooling during summer, dehumidification and ventilation in monsoon and winter heating. In order to ascertain the performance of the design, its thermal analysis has been carried out; the performance is seen to be quite satisfactory.  相似文献   

19.
20.
从表面能的基本含义入手,总结了表面能的影响因素以及降低表面能的原理与方法,并对换热表面的表面能与换热性能之间的关系做了理论分析。通过分析得到:表面能越低,换热性能越好。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号