首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An analysis has been carried out on the first practical application in Korea of the design and installation of building integrated photovoltaic (BIPV) modules on the windows covering the front side of a building by using transparent thin-film amorphous silicon solar cells. This analysis was performed through long-term monitoring of performance for 2 years. Electrical energy generation per unit power output was estimated through the 2 year monitoring of an actual BIPV system, which were 48.4 kWh/kWp/month and 580.5 kWh/kWp/year, respectively, while the measured energy generation data in this study were almost half of that reported from the existing data which were derived by general amorphous thin-film solar cell application. The reason is that the azimuth of the tested BIPV system in this study was inclined to 50° in the southwest and moreover, the self-shade caused by the projected building mass resulted in the further reduction of energy generation efficiency. From simulating influencing factors such as azimuth and shading, the measured energy generation efficiency in the tested condition can be improved up to 47% by changing the building location in terms of azimuth and shading, thus allowing better solar radiation for the PV module. Thus, from the real application of the BIPV system, the installation of a PV module associated with azimuth and shading can be said to be the essentially influencing factors on PV performance, and both factors can be useful design parameters in order to optimize a PV system for an architectural BIPV application.  相似文献   

2.
This paper presents the life cycle cost analysis of the single slope passive and hybrid photovoltaic (PV/T) active solar stills, based on the annual performance at 0.05 m water depth. Effects of various parameters, namely interest rate, life of the system and the maintenance cost have been taken into account. The comparative cost of distilled water produced from passive solar still (Rs. 0.70/kg) is found to be less than hybrid (PV/T) active solar still (Rs. 1.93/kg) for 30 years life time of the systems. The payback periods of the passive and hybrid (PV/T) active solar still are estimated to be in the range of 1.1–6.2 years and 3.3–23.9 years, respectively, based on selling price of distilled water in the range of Rs. 10/kg to Rs. 2/kg. The energy payback time (EPBT) has been estimated as 2.9 and 4.7 years, respectively.  相似文献   

3.
The production of electricity from renewable sources plays a strategic role in the future of energy because it helps to effectively manage climate change through an energy generation portfolio with lower emissions of greenhouse gases.Photovoltaic solar energy is safe and sustainable and is characterised by a growing trend with a cumulative installed capacity that has reached a total of 40 GW in 2010.In this paper, investigations are presented using multiple calculations: Energy Payback Time (EPBT), Greenhouse Gas per kilowatt hour (GHG/kWh), Energy Return on Investment (EROI), Greenhouse Gas Payback Time (GPBT) and Greenhouse Gas Return on Investment (GROI). These metrics make it possible to define the energy and environmental performances for a building-integrated photovoltaic system located in Italy.The module efficiency, the embodied energy and the annual solar irradiance are variables that play a strong role in this analysis. The key parameters include the type of solar cells (e.g., mono-crystalline silicon, polycrystalline silicon, amorphous silicon, cadmium telluride) and the location where the system is installed (Milan, Rome and Palermo).The results determine whether solar energy has a viable strategic role in the global energy market.  相似文献   

4.
In this paper, a study is carried out to evaluate the annual thermal and exergy performance of a photovoltaic/thermal (PV/T) and earth air heat exchanger (EAHE) system, integrated with a greenhouse, located at IIT Delhi, India, for different climatic conditions of Srinagar, Mumbai, Jodhpur, New Delhi and Bangalore. A comparison is made of various energy metrics, such as energy payback time (EPBT), electricity production factor (EPF) and life cycle conversion efficiency (LCCE) of the system by considering four weather conditions (a–d type) for five climatic zones. The embodied energy and annual energy outputs have been used for evaluation of the energy metrics. The annual overall thermal energy, annual electrical energy savings and annual exergy was found to be best for the climatic condition of Jodhpur at 29,156.8 kWh, 1185 kWh and 1366.4 kWh, respectively when compared with other weather stations covered in the study, due to higher solar intensity I and sunshine hours, and is lowest for Srinagar station. The results also showed that energy payback time for Jodhpur station is lowest at 16.7 years and highest for Srinagar station at 21.6 years. Electricity production factor (EPF) is highest for Jodhpur, i.e. 2.04 and Life cycle conversion efficiency (LCCE) is highest for Srinagar station. It is also observed that LCCE increases with increase in life cycle.  相似文献   

5.
A hybrid system, composed of a photovoltaic (PV) module and a solar thermal collector is constructed and tested for energy collection at a geographic location of Cyprus. Normally, it is required to install a PV system occupying an area of about 10 m2 in order to produce electrical energy; 7 kWh/day, required by a typical household. In this experimental study, we used only two PV modules of area approximately 0.6 m2 (i.e., 1.3×0.47 m2) each. PV modules absorb a considerable amount of solar radiation that generate undesirable heat. This thermal energy, however, may be utilized in water pre-heating applications. The proposed hybrid system produces about 2.8 kWh thermal energy daily. Various attachments that are placed over the hybrid modules lead to a total of 11.5% loss in electrical energy generation. This loss, however, represents only 1% of the 7 kWh energy that is consumed by a typical household in northern Cyprus. The pay-back period for the modification is less than 2 years. The low investment cost and the relatively short pay-back period make this hybrid system economically attractive.  相似文献   

6.
Hassan Radhi 《Solar Energy》2010,84(12):2009-2021
Developments in the design and manufacture of photovoltaic cells have recently been a growing concern in the UAE. At present, the embodied energy pay-back time (EPBT) is the criterion used for comparing the viability of such technology against other forms. However, the impact of PV technology on the thermal performance of buildings is not considered at the time of EPBT estimation. If additional energy savings gained over the PV system life are also included, the total EPBT could be shorter. This paper explores the variation of the total energy of building integrated photovoltaic systems (BiPV) as a wall cladding system applied to the UAE commercial sector and shows that the ratio between PV output and saving in energy due to PV panels is within the range of 1:3–1:4. The result indicates that for the southern and western façades in the UAE, the embodied energy pay-back time for photovoltaic system is within the range of 12–13 years. When reductions in operational energy are considered, the pay-back time is reduced to 3.0–3.2 years. This study comes to the conclusion that the reduction in operational energy due to PV panels represents an important factor in the estimation of EPBT.  相似文献   

7.
Yuxiang Chen  Khaled Galal 《Solar Energy》2010,84(11):1908-1919
This paper is the second of two papers that describe the modeling and design of a building-integrated photovoltaic-thermal (BIPV/T) system thermally coupled with a ventilated concrete slab (VCS) adopted in a prefabricated, two-storey detached, low energy solar house and their performance assessment based on monitored data. The VCS concept is based on an integrated thermal-structural design with active storage of solar thermal energy while serving as a structural component - the basement floor slab (∼33 m2). This paper describes the numerical modeling, design, and thermal performance assessment of the VCS. The thermal performance of the VCS during the commissioning of the unoccupied house is presented. Analysis of the monitored data shows that the VCS can store 9-12 kWh of heat from the total thermal energy collected by the BIPV/T system, on a typical clear sunny day with an outdoor temperature of about 0 °C. It can also accumulate thermal energy during a series of clear sunny days without overheating the slab surface or the living space. This research shows that coupling the VCS with the BIPV/T system is a viable method to enhance the utilization of collected solar thermal energy. A method is presented for creating a simplified three-dimensional, control volume finite difference, explicit thermal model of the VCS. The model is created and validated using monitored data. The modeling method is suitable for detailed parametric study of the thermal behavior of the VCS without excessive computational effort.  相似文献   

8.
This article evaluates a 1.4‐kW building integrated grid‐connected photovoltaic plant. The PV plant was installed in the Faculty of Engineering solar energy lab, Sohar University, Oman, and the system data have been collected for a year from July 2017 to June 2018. The grid‐connected system was evaluated in terms of power, energy, specific yield, capacity factor, and cost of energy, and payback period. The measured diffuse and global solar irradiations are 3289 and 6182 Wh/m2, respectively. Four predictive models (TLRN, FRNN‐1, FRNN‐2, and FRNN‐3) using deep learning approach based on RNN and TLRN were proposed to predict the PV current performance through data input of temperature (T) and solar irradiance (G). The experiment results found that the highest energy production, array, reference, and final yields are 245.8 kWh, 3.43 to 5.65 kWh/kWp‐day, 4.61 to 7.33 kWh/kWp‐day, and 3.24 to 4.82 kWh/kWp‐day, respectively. Meanwhile, CF, CoE, and PBP were found to be 21.7%, 0.045 USD/kWh and 11.17 years, respectively. The highest performance for prediction models were found for FRNN‐2 and FRNN‐3 due to they exhibit lower MSE which means being tightly fitted to experiments.  相似文献   

9.
Solar and wind energies are likely to play an important role in the future energy generation in Oman. This paper utilizes average daily global solar radiation and sunshine duration data of 25 locations in Oman to study the economic prospects of solar energy. The study considers a solar PV power plant of 5-MW at each of the 25 locations. The global solar radiation varies between slightly greater than 4 kWh/m2/day at Sur to about 6 kWh/m2/day at Marmul while the average value in the 25 locations is more than 5 kWh/m2/day. The results show that the renewable energy produced each year from the PV power plant varies between 9000 MWh at Marmul and 6200 MWh at Sur while the mean value is 7700 MWh of all the 25 locations. The capacity factor of PV plant varies between 20% and 14% and the cost of electricity varies between 210 US$/MWh and 304 US$/MWh for the best location to the least attractive location, respectively. The study has also found that the PV energy at the best location is competitive with diesel generation without including the externality costs of diesel. Renewable energy support policies that can be implemented in Oman are also discussed.  相似文献   

10.
In life cycle assessment (LCA) of solar PV systems, energy pay back time (EPBT) is the commonly used indicator to justify its primary energy use. However, EPBT is a function of competing energy sources with which electricity from solar PV is compared, and amount of electricity generated from the solar PV system which varies with local irradiation and ambient conditions. Therefore, it is more appropriate to use site-specific EPBT for major decision-making in power generation planning. LCA and life cycle cost analysis are performed for a distributed 2.7 kWp grid-connected mono-crystalline solar PV system operating in Singapore. This paper presents various EPBT analyses of the solar PV system with reference to a fuel oil-fired steam turbine and their greenhouse gas (GHG) emissions and costs are also compared. The study reveals that GHG emission from electricity generation from the solar PV system is less than one-fourth that from an oil-fired steam turbine plant and one-half that from a gas-fired combined cycle plant. However, the cost of electricity is about five to seven times higher than that from the oil or gas fired power plant. The environmental uncertainties of the solar PV system are also critically reviewed and presented.  相似文献   

11.
In this paper, the environmental benefits or renewable energy systems are initially presented followed by a study of the thermal performance, economics and environmental protection offered by thermosiphon solar water heating systems. The system investigated is of the domestic size, suitable to satisfy most of the hot water needs of a family of four persons. The results presented in this paper show that considerable percentage of the hot water needs of the family are covered with solar energy. This is expressed as the solar contribution and its annual value is 79%. Additionally, the system investigated give positive and very promising financial characteristics with payback time of 2.7 years and life cycle savings of 2240 € with electricity backup and payback time of 4.5 years and life cycle savings of 1056 € with diesel backup. From the results it can also be shown that by using solar energy considerable amounts of greenhouse polluting gasses are avoided. The saving, compared to a conventional system, is about 70% for electricity or diesel backup. With respect to life cycle assessment of the systems, the energy spent for the manufacture and installation of the solar systems is recouped in about 13 months, whereas the payback time with respect to emissions produced from the embodied energy required for the manufacture and installation of the systems varies from a few months to 3.2 years according to the fuel and the particular pollutant considered. It can therefore be concluded that thermosiphon solar water hearting systems offer significant protection to the environment and should be employed whenever possible in order to achieve a sustainable future.  相似文献   

12.
This paper presents rigorous experimental outdoor performance of a 2.32 kWP stand-alone photovoltaic (SAPV) system in New Delhi (India) for four weather types in each month such as clear, hazy, partially cloudy/foggy and fully cloudy/foggy weather conditions respectively. The daily power generated from the existing SAPV system was experimentally found in the range of 4–6 kW h/day depending on the prevailing sky conditions. The number of days and daily power generated corresponding to four weather types in each month were used to determine monthly and subsequently annual power generation from the existing SAPV system. There are three daily load profiles with and without earth to air heat exchanger suitable for three seasons like summer (3.75–6.15 kW h/day), winter (2.79–5.19 kW h/day) and rainy (3.75 kW h/day). The hourly efficiency of the SAPV system components are determined and presented in this paper. The life cycle cost (LCC) analysis for the existing typical SAPV system is carried out to determine unit cost of electricity. The effect of annual degradation rate of PV system efficiency is also presented in this paper. The energy production factor (EPF) and the energy payback time (EPBT) of the SAPV system was also determined and presented in this paper.  相似文献   

13.
Building-integrated photovoltaic (BIPV) technology has become a major area of research due to environ-mental concerns. This article studies the feasibility of cladding high-rise towers in Doha with solar photovoltaic modules. Specifically, the case of the Qatar Financial Centre (QFC) is discussed. The major aim of the work is to evaluate the technical feasibility, economic impact and environmental effects of using photovoltaic panels on commercial towers in Qatar. Experimental data on solar irradiance and the effect of shading on the QFC Tower are presented. Numerical calculations are done using solar pathfinder software. The studies show that, although there is a significant amount of saving in CO2 emission by using BIPV on towers in Doha, the payback period is still very long due to the cheaper cost of grid electricity in Qatar and poor conversion efficiency of PV panels. The complete system layout is presented and viable solutions are investigated.  相似文献   

14.
The Net Zero Energy House (NZEH) presented in this paper is an energy efficient house that uses available solar technologies to generate at least as much primary energy as the house uses over the course of the year. The computer simulation results show that it is technically feasible to reach the goal of NZEH in the cold climate of Montreal. In terms of the life cycle energy use, which considers the operating and embodied energy of the house, the energy payback time is 8.4–8.7 years, when the NZEH is compared with an average house that complies with the provincial code. The energy payback ratio of the combisystem is 3.5–3.8 compared with the heating system of conventional house. By converting solar energy, the combisystem supplies at least 3.5 times more energy than the energy invested for manufacturing and shipping the system. The life cycle cost analysis of the NZEH shows, however, that due to the high cost of the solar technologies and the low cost of electricity in Montreal, financial payback is never achieved.  相似文献   

15.
Many universities have plans to reduce campus energy consumption with developed energy efficiency strategies, supply the energy needs of the university campus with renewable energy and create a green campus. In order to serve this purpose, this study focuses on the simulation of the installation of an on-grid photovoltaic (PV) power system at the Vocational Colleges Campus, Hitit University. On the other hand, the integration of the simulated PV system with a gas fired-trigeneration system is discussed. Moreover, the study explores opportunities for solar hydrogen generation without energy storage on campus. For the PV system simulation, three different scenarios were created by using web-based PV system design software (HelioScope). Installed powers in the simulation were found as 94.2 kWe, 123.9 kWe, and 157.5 kWe for the low scenario (on the rooftop), high scenario (on the rooftop), and the high + PV canopy arrays scenario (on the rooftop and an outdoor parking area), respectively. The levelized cost of electricity (LCOE) values were 0.061 $/kWh, 0.065 $/kWh, and 0.063 $/kWh for the low scenario, high scenario, and the scenario including PV canopy, respectively. The energy payback time is found to be 6.47–6.94 years for the 20–25 years lifetime of the PV plant. The simulation results showed that the PV system could support it by generating additional electrical energy up to 25% of the existing system. The campus can reduce GHG emissions of 1546–2272 tonnes-CO2eq, which is equivalent to 142–209 ha of forest-absorbing carbon unused during the life of the PV system. Depending on the production and consumption methods utilized on campus, which is a location with relatively large solar potential, the levelized cost of hydrogen (LCOH) of hydrogen generation ranged from 0.054 $/kWhH2 (1.78 $/kgH2) to 0.103 $/kWhH2 (3.4 $/kgH2). Consequently, with proper planning and design, a grid-connected PV-trigeneration-hydrogen generation hybrid system on a university campus may operate successfully.  相似文献   

16.
In this study, the techno-economic assessment of GCPVT with nanofluid has been investigated based on theoretical and experimental work in Malaysia. The productivity and utilisation of the PV have been investigated using yield and capacity factors (CFs), respectively. Also, the cost of energy and payback period has been calculated. The system installed, tested, and data have been collected. Evaluation of the system in terms of current, voltage, power and efficiency are presented. The average daily ambient temperature and total global solar energy in Kuala Lumpur are 38.89°C and 4062?Wh/m2, respectively. MATLAB software is used to analyse the measured data. The assessment results show that the GCPVT system has annual yield factor, CF, the cost of energy; payback period, and efficiency are (128.34–183.75)?kWh/kWp, (17.82–25.52)%, 0.196?USD/kWh, 7–8 years and 9.1%, respectively. This study indicates that the GCPVT system with nanofluid improved the PV technical and economic performance.  相似文献   

17.
Malaysia is situated at the equatorial region with an average solar radiation of 400-600 MJ/m2 per month. It has a promising potential to establish large scale solar power installations; however, solar energy is still at the infancy stage due to the high cost of photovoltaic (PV) cells and solar electricity tariff rate. The Malaysian government is keen to develop solar energy as one of the significant sources of energy in the country. According to the 9th Malaysia Plan (9MP), a large allocation had been dedicated for implementation of solar PV systems. On 25th July 2005, a Malaysian Building Integrated Photovoltaic (MBIPV) project had been announced and it was planned to end by 2010. The project consists of three categories which include: BIPV demonstration, national “SURIA1000” and BIPV showcase. Greater emphasis will be placed on energy efficiency under the Tenth Malaysia Plan (2011-2015). This paper discusses present and future situation of solar power in Malaysia, utilization of solar energy and the strategies taken by the Malaysian government and Non-Government Organizations (NGOs) to promote solar energy thermal applications and electricity power generation in the future.  相似文献   

18.
Building-integrated photovoltaics (BIPV) is an innovative green solution that incorporated energy generation into the building façade with modification on the building material or architectural structure. It is a clean and reliable solution that conserves the aesthetical value of the architecture and has the potential to enhance the building's energy efficiency. Malaysia's tropical location has a high solar energy potential to be exploited, and BIPV is a very innovative aspect of technology to employ the available energy. Heriot-Watt University Malaysia (HWUM) has a unique roof design that could be utilized as an application of the BIPV system to generate electricity, reducing the carbon footprint of the facility. Eight BIPV systems of different PV technologies and module types and with capacities of 411.8 to 1085.6 kW were proposed for the building. The environmental plugin software has been integrated with a building geometry modelling tool to visualize and estimate the energy potential from the roof surface in a 3D modelling software. Additionally, detailed system simulations are conducted using PVSyst software, where results and performance parameters are analysed. The roof surface is shown to provide great energy potential and studied scenarios generated between 548 and 1451 MWh yearly with PR range from 78% to 85%. C-Si scenarios offer the best economical profitability with payback period of 4.4 to 6.3 years. The recommended scenario has a size of 1085.5 kW and utilizes thin-film CdTe PV modules. The system generates 1415 MWh annually with a performance ratio of 84.9%, which saves 62.8% of the electricity bill and has an estimated cost of 901 000 USD. Installation of the proposed system should preserve the aesthetical value of the building's roof, satisfy BIPV rules, and most importantly, conserves energy, making the building greener.  相似文献   

19.
Solar- and nuclear-electricity-generation technologies often are deemed “carbon-free” because their operation does not generate any carbon dioxide. However, this is not so when considering their entire lifecycle of energy production; carbon dioxide and other gases are emitted during the extraction, processing, and disposal of associated materials. We determined the greenhouse gas (GHG) emissions, namely, CO2, CH4, N2O, and chlorofluorocarbons due to materials and energy flows throughout all stages of the life of commercial technologies for solar-electric- and nuclear-power generation, based on data from 12 photovoltaic (PV) companies, and reviews of nuclear-fuel life cycles in the United States, Europe, and Japan. Previous GHG estimates vary widely, from 40 to 180 CO2-eq./kWh for PV, and 3.5–100 CO2-eq./kWh for nuclear power. Country-specific parameters account for many of these differences, which are exacerbated by outdated information. We conclude, instead, that lifetime GHG emissions from solar- and nuclear-fuel cycles in the United States are comparable under actual production conditions and average solar irradiation, viz., 22–49 g CO2-eq./kWh (average US), 17–39 g CO2-eq./kWh (south west) for solar electric, and 16–55 g CO2-eq./kWh for nuclear energy. However, several factors may significantly change this picture within the next 5 years, and there are unanswered questions about the nuclear fuel cycle that warrant further analyses.  相似文献   

20.
Organic solar cells are an emerging photovoltaic technology that is inexpensive and easy to manufacture, despite low efficiency and stability. A model, named TEEOS (Technical and Economic Evaluator for Organic Solar), is presented that evaluates organic solar cells for various solar energy applications in different geographic locations, in terms of two financial indicators, payback period and net present value (NPV). TEEOS uses SMARTS2 software to estimate broadband (280-4000 nm) spectral irradiance data and with the use of a cloud modification factor, predicts hourly irradiation in the absence of actual broadband irradiance data, which is scarce for most urban locations. By using the avoided cost of electricity, annual savings are calculated which produce the financial indicators. It is hoped that these financial indicators can help guide certain technical decisions regarding the direction of research for organic solar cells, for example, increasing efficiency or increasing the absorptive wavelength range. A sample calculation using solar hats is shown to be uneconomical, but a good example of large-scale organic PV production.  相似文献   