共查询到12条相似文献,搜索用时 49 毫秒
1.
2.
3.
4.
5.
6.
在用瑞利散射法诊断团簇尺度的实验中,提出了相对强度测量法,为此设计了一个基于高速采样的信号波形获取与处理系统,提出了信号寻峰算法及拟合算法,完成了系统软件的设计,实现了对两路信号波形的获取与快速处理,并成功地应用于瑞利散射诊断团簇尺度的实验中. 相似文献
7.
利用光电倍增管测量团簇的瑞利散射,信号幅度与团簇源背压有关,也与光源强度和光电倍增管工作电压有关.当团簇源背压变化范围较大时,散射信号幅度变化可能导致光电倍增管信号超出线性范围.为此,在不同的光源强度、不同的工作电压下对光电倍增管输出信号进行了刻度,得到了输出信号幅度随光源强度、工作电压之间的关系.用此关系.对不同条件下的实验数据进行归一化处理,得到了团簇散射因子随团簇源背压的关系曲线,与同类实验和理论结果相符. 相似文献
8.
9.
10.
11.
Tianchi WANG Haiyang WANG Wei CHEN Yingchao DU Linshen XIE Tao HUANG Zhiqiang CHEN Junna LI Fan GUO Gang WU 《等离子体科学和技术》2021,23(11):115507-166
In this paper,a calculation model for the breakdown time delay and jitter of gas switches under hundred-nanosecond pulses is proposed and applied in a self-triggered pre-ionized switch.The effects of injection time of pre-ionization,pulse rise time,and the pre-ionization jitter are discussed and verified through experiments.It indicates that the pre-ionization should be injected when the electric field is high enough in the gap,injection after 80%peak-time can ensure its effectiveness.Then the statistical time delay jitter will be determined by the pre-ionization jitter,which is an intrinsic restriction of the self-triggered switch.However,when the changing rate of the pulsed electric field exceeds a certain value,the breakdown time delay jitter can be partly offset in the formative stage because the formative time delay has an exponential relationship with the electric field.Therefore,lower time jitter can be obtained under pulses with a shorter pulse rise time.In general,the results of the calculation model agree with the experimental results,and the experimental parameters which lead to a low jitter can also be used as a reference. 相似文献
12.
《Journal of Nuclear Science and Technology》2013,50(9):1199-1209
The ECCS performance, which mitigates a postulated catastrophic failure of the main reactor coolant piping during the full power operation, is judged to cover the consequences of LOCA occurring in other plant operational states. During Mode 3 with an accumulator isolated and Mode 4, since the normal alignment of ECCS equipments is changed from that which is available during the power operation, a potential safety issue, which involved the performance of ECCS for LOCA during Mode 3 with the accumulator isolated and Mode 4, was identified in 1985. This study is performed as the plant specific shutdown LOCA program for the power uprated Kori-3 and 4, of which the nominal core power is planned to increase by 4.5%. We determine and verify the operator action time to initiate SI following a small break LOCA in order that the peak clad temperature of fuel does not exceed the 10CFR50.46 limit of 1,477.6 K. We evaluate the 0.1524 m (6 inches) pipe break in the cold leg to develop the SI initiation time. There is a considerable margin to the 10CFR50.46 limit of 1,477.6 K in the case that the SI is manually initiated at 25 min after an operator identifies the symptom of a small break LOCA. However, in respect of the safe plant operation, we decide the operator SI initiation time as 15 min in order that the SI water is supplied to prevent the fuel heat-up during the blowdown phase of a small break LOCA. After then, we evaluate the applicability of the pre-determined SI initiation time to other small break LOCAs, which have a smaller break size, a lower initial decay heat level or a different break location. Since the peak clad temperatures of applicability evaluation cases are lower than those of the umbrella case, we confirm that the pre-determined SI initiation time can be applied to mitigate the small break LOCAs during the plant shutdown operation. The SI initiation time developed in this study will be used in the Abnormal Operating Procedure of the power uprated Kori-3 and 4 for the small break LOCAs during the plant shutdown operation. 相似文献