首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Limiting current measurements were made at the electrode surfaces fixed flush with the inner wall of a helically coiled circular tube. The measured limiting current facilitated the computation of wall-liquid mass transfer coefficients. The mass transfer data were obtained for the flow of electrolyte through the helical coil in the absence and presence of packed solids. The mass transfer coefficient was found to decrease with increasing p/D ratio and approached minimum for straight tube case. The mass transfer data were correlated in terms of Colburn factor jD, expressed as a function of Reynolds number Re and torsion number Tn obtained as jD=0.34Re−0.58Tn0.17. Analysis of the experimental data obtained in case of packed coiled tubes of circular cros- section revealed that the effect of p/D ratio on pressure drop was observed to be insignificant. The effect of pitch on mass transfer coefficient in case of packed helical coils was found to be marginal.  相似文献   

2.
An investigation on flow boiling heat transfer and pressure drop of HFC-134a inside a vertical helically coiled concentric tube-in-tube heat exchanger has been experimentally carried out. The test section is a six-turn helically coiled tube with 5.786-m length, in which refrigerant HFC-134a flowing inside the inner tube is heated by the water flowing in the annulus. The diameter and the pitch of the coil are 305 mm and 45 mm, respectively. The outer diameter of the inner tube and its thickness are respectively 9.52 and 0.62 mm. The inner diameter of the outer tube is 29 mm. The average vapor qualities in test section were varied from 0.1 to 0.8. The tests were conducted with three different mass velocities of 112, 132, and 152 kg/m2-s. Analysis of obtained data showed that increasing of both the vapor qualities and the mass fluxes leads to higher heat transfer coefficients and pressure drops. Also, it was observed that the heat transfer coefficient is enhanced and also the pressure drop is increased when a helically coiled tube is used instead of a straight tube. Based on the present experimental results, a correlation was developed to predict the flow boiling heat transfer coefficient in vertical helically coiled tubes.  相似文献   

3.
The pressure drop and boiling heat transfer characteristics of steam-water two-phase flow were studied in a small horizontal helically coiled tubing once-through steam generator. The generator was constructed of a 9-mm ID 1Cr18Ni9Ti stainless steel tube with 292-mm coil diameter and 30-mm pitch. Experiments were performed in a range of steam qualities up to 0.95, system pressure 0.5-3.5 MPa, mass flux 236-943 kg/m2s and heat flux 0-900 kW/m2. A new two-phase frictional pressure drop correlation was obtained from the experimental data using Chisholm’s B-coefficient method. The boiling heat transfer was found to be dependent on both of mass flux and heat flux. This implies that both the nucleation mechanism and the convection mechanism have the same importance to forced convective boiling heat transfer in a small horizontal helically coiled tube over the full range of steam qualities (pre-critical heat flux qualities of 0.1-0.9), which is different from the situations in larger helically coiled tube where the convection mechanism dominates at qualities typically >0.1. Traditional single parameter Lockhart-Martinelli type correlations failed to satisfactorily correlate present experimental data, and in this paper a new flow boiling heat transfer correlation was proposed to better correlate the experimental data.  相似文献   

4.
A capillary tube‐based CO2 heat pump is unique because of the transcritical nature of the system. The transcritical cycle has two independent parameters, pressure and temperature, unlike the subcritical cycle. A comparative study for various operating conditions, based on system COP and exergetic efficiency, of a capillary tube and a controllable expansion valve‐based transcritical carbon dioxide heat pump systems for simultaneous heating and cooling at 73 and 4°C, respectively, is presented here. Two optimized capillary tubes having diameter of 1.5 and 1.6 mm are compared with an equivalent controllable throttle valve. Heat transfer and fluid flow effects are included in the gas cooler and evaporator model and capillary tube employs the homogeneous flow model to simulate two‐phase flow. Subcritical and supercritical thermodynamic and transport properties of CO2 are calculated employing a precision in‐house property code. Optimization of effective distribution of total heat exchanger area ratio between gas cooler and evaporator is investigated. The exergetic efficiency is better in case of the capillary tube than that of a controllable throttle valve‐based system. Capillary tube‐based system is shown to be quite flexible regarding changes in ambient temperature, almost behaving to offer an optimal pressure control just like the controllable expansion valve yielding both, maximum system COP and maximum exergetic efficiency. Relatively at a smaller diameter, the capillary tube exhibits better exergetic efficiency. Capillary tube length is the critical parameter that influences system optimum conditions. The exergy flow diagram exhibits that compressor, gas cooler and capillary tube contribute a larger share, in that order, to system irreversibility. It is fairly established in this study that a capillary tube can be a good engineering option for small capacity systems in lieu of an expansion valve, which has been thought of as the only possible solution to attain the pressure optimization, an important feature of all transcritical CO2 systems. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
A theoretical analysis of a two‐stage transcritical CO2 cooling cycle is presented. The effect of a two‐stage cycle with intercooling process on the system coefficient of cooling performance is presented for various gas cooler pressures. However, the performance comparison between one‐stage and two‐stage cycles is presented for same operating conditions. Gas cooler pressure, compressor isentropic efficiency, gas cooler efficiency, intercooling quantity and refrigerant outlet temperature from the gas cooler are used as variable parameters in the analysis. It is concluded that the performance of the two‐stage transcritical CO2 cycle is approximately 30% higher than that of the one‐stage transcritical CO2 cycle. Hence, the two‐stage compression and intercooling processes can be assumed as valuable applications to improve the transcritical CO2 cycle performance. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

6.
The two-phase heat transfer coefficient and pressure drop of pure HFC-134a condensing inside a smooth helically coiled concentric tube-in-tube heat exchanger are experimentally investigated. The test section is a 5.786 m long helically coiled double tube with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The inner tube is made from smooth copper tubing of 9.52 mm outer diameter and 8.3 mm inner diameter. The outer tube is made from smooth copper tubing of 23.2 mm outer diameter and 21.2 mm inner diameter. The heat exchanger is fabricated by bending a straight copper double-concentric tube into a helical coil of six turns. The diameter of coil is 305 mm. The pitch of coil is 35 mm. The test runs are done at average saturation condensing temperatures ranging between 40 and 50 °C. The mass fluxes are between 400 and 800 kg m−2 s−1 and the heat fluxes are between 5 and 10 kW m−2. The pressure drop across the test section is directly measured by a differential pressure transducer. The quality of the refrigerant in the test section is calculated using the temperature and pressure obtained from the experiment. The average heat transfer coefficient of the refrigerant is determined by applying an energy balance based on the energy rejected from the test section. The effects of heat flux, mass flux and, condensation temperature on the heat transfer coefficients and pressure drop are also discussed. It is found that the percentage increase of the average heat transfer coefficient and the pressure drop of the helically coiled concentric tube-in-tube heat exchanger, compared with that of the straight tube-in-tube heat exchanger, are in the range of 33–53% and 29–46%, respectively. New correlations for the condensation heat transfer coefficient and pressure drop are proposed for practical applications.  相似文献   

7.
Experiments were carried out on the flow pattern, heat transfer, and pressure drop of flow boiling of pure CO2 and CO2‐oil mixtures in horizontal smooth and micro‐fin tubes. The smooth tube is a stainless steel tube with an inner diameter of 3.76 mm. The micro‐fin tube is a copper tube with a mean inner diameter of 3.75 mm. The experiments were carried out at mass velocities from 100 to 500 kg/(m2·s), saturation temperature of 10 °C, and the circulation ratio of lubricating oil (PAG) was from 0 to 1.0 mass%. Flow pattern observations mainly showed slug and wavy flow for the smooth tube, but annular flow for the micro‐fin tube. Compared with the flow patterns in the case of pure CO2, an increase in frequency of slug occurrence in the slug flow region, and a decrease in the quantity of liquid at the top of the tube in the annular flow region were observed in the case of CO2‐oil mixtures. With pure CO2, the flow boiling heat transfer was dominated by nucleate boiling in the low vapor quality region, and the heat transfer coefficients for the micro‐fin tube were higher than those of the smooth tube. With CO2‐oil mixtures, the flow boiling heat transfer was dominated by convective evaporation, especially in the high vapor quality region. In addition, the heat transfer coefficient decreased significantly when the oil circulation ratio was larger than 0.1 mass%. For the pressure drop characteristics, in the case of pure CO2, the homogeneous flow model agreed with the experimental results within ±30% for the smooth tube. The pressure drops of the micro‐fin tube were 0–70% higher than those predicted with the homogeneous flow model, and the pressure drops increased for the high oil circulation ratio and high vapor quality conditions. The increases in the pressure drops were considered to be due to the increase in the thickness of the oil film and the decrease in the effective flow cross‐sectional area. © 2010 Wiley Periodicals, Inc. Heat Trans Asian Res; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.20287  相似文献   

8.
CO_2气体冷却器的结构和换热效果对CO_2跨临界循环影响较大.为设计出高效的气体冷却器,有必要对其性能进行模拟和优化.采用有限单元法建立了小型CO_2热泵热水器中气体冷却器稳态分布参数模型,分别对其CO_2侧和水侧的流动与换热进行了数值仿真,运用该模型分别针对CO_2侧进口压力对气体冷却器设计管长和CO_2换热性能的影响进行了分析.结果表明,CO_2侧进口压力在8~12 MPa时,从8 MPa开始每递增1 MPa,换热系数峰值比压力增加1 MPa前的依次递减约57.14%、33.33%、25.00%、9.83%,设计管长比压力增加1 MPa前的依次递减约55.60%、18.75%、11.33%、9.09%.综合考虑管道耗材与CO_2换热能力,针对小型CO_2热泵系统,气体冷却器CO_2侧进口压力取8.5~10 MPa较合理.研究可为气体冷却器设计提供理论指导.  相似文献   

9.
This paper presents a computational study of an energy‐efficient technique for post‐combustion CO2 capture using novel material, namely, Mg‐MOF‐74, using pressure swing adsorption (PSA) processes. A detailed one‐dimensional, transient mathematical model has been formulated to include the heat and mass transfer, the pressure drop and multicomponent mass diffusion. The PSA model has been further extended by incorporating a heat regenerating process to enhance CO2 sequestration. The heat dissipated during adsorption is stored in packed sand bed and released during desorption step for heating purpose. The model has been implemented on a MATLAB program using second‐order discretization. Validation of the model was performed using a complete experimental data set for CO2 sequestration using zeolite 13X. Simulation of the PSA experiment on fixed bed has been carried out to evaluate the capacity of Mg‐MOF‐74 for CO2 capture with varying feed gas temperature of 28 and 100 °C, varying pressurization and purge times and heat regeneration. It was discovered that the PSA process with heat regeneration system might be advantageous because it achieves equivalent amount of CO2 sequestration in fewer PSA cycles compared with PSA without heat regeneration system. Based on the simulated conditions, CO2 recovery with Mg‐MOF‐74 gives high percentage purity (above 98%) for the captured CO2. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
The objective of this work is to train an artificial neural network (ANN) to predict the performance of gas cooler in carbon dioxide transcritical air-conditioning system. The designed ANN was trained by performance test data under varying conditions. The deviations between the ANN predicted and measured data are basically less than ±5%. The well-trained ANN is then used to predict the effects of the five input parameters individually. The predicted results show that for the heat transfer and CO2 pressure drop the most effective factor is the inlet air velocity, then come the inlet CO2 pressure and temperature. The inlet mass flow rate can enhance heat transfer with a much larger CO2 pressure drop penalty. The most unfavorable factor is the increase in the inlet air temperature, leading to the deterioration of heat transfer and severely increase in CO2 pressure drop.  相似文献   

11.
In this paper, a new configuration of ejector‐expansion transcritical CO2 (TRCC) refrigeration cycle is presented, which uses an internal heat exchanger and intercooler to enhance the performance of the new cycle. The theoretical analysis on the performance characteristics was carried out for the new cycle based on the first and second laws of thermodynamics. It was found that, compared with the conventional transcritical CO2 cycle and ejector‐expansion transcritical CO2 cycle, the simulation results show that the coefficient of performance and second law efficiency of the new cycle were increased by about 55.5 and 26%, respectively, under the operating conditions that evaporator temperature is 10°C, gas cooler outlet temperature is 40°C and gas cooler pressure is optimum pressure. It is also concluded that the entrainment ratio for the new ejector‐expansion TRCC cycle is on average 35% higher than that of the conventional ejector‐expansion TRCC cycle. The analysis results are of significance to provide theoretical basis for design optimization of the transcritical CO2 refrigeration cycle with an ejector‐expansion device, internal heat exchanger and intercooler. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

12.
Steady heat transfer enhancement has been studied in helically coiled-tube heat exchangers. The outer side of the wall of the heat exchanger contains a helical corrugation which makes a helical rib on the inner side of the tube wall to induce additional swirling motion of fluid particles. Numerical calculations have been carried out to examine different geometrical parameters and the impact of flow and thermal boundary conditions for the heat transfer rate in laminar and transitional flow regimes. Calculated results have been compared to existing empirical formulas and experimental tests to investigate the validity of the numerical results in case of common helical tube heat exchanger and additionally results of the numerical computation of corrugated straight tubes for laminar and transition flow have been validated with experimental tests available in the literature. Comparison of the flow and temperature fields in case of common helical tube and the coil with spirally corrugated wall configuration are discussed. Heat exchanger coils with helically corrugated wall configuration show 80–100% increase for the inner side heat transfer rate due to the additionally developed swirling motion while the relative pressure drop is 10–600% larger compared to the common helically coiled heat exchangers. New empirical correlation has been proposed for the fully developed inner side heat transfer prediction in case of helically corrugated wall configuration.  相似文献   

13.
The two-phase heat transfer coefficient and pressure drop of HFC-134a during evaporation inside a smooth helically coiled concentric tube-in-tube heat exchanger are experimentally investigated. The test section is a 5.786-m long helically coiled tube with refrigerant flowing in the inner tube and heating water flowing in the annulus. The inner tube is made from copper tubing of 9.52 mm outer diameter and 7.2 mm inner diameter. The heat exchanger is fabricated by bending a straight copper tube into a spiral coil. The diameter of coil is 305 mm. The test run are done at average saturated evaporating temperatures ranging between 10 and 20 °C. The mass fluxes are between 400 and 800 kg m−2 s−1 and the heat fluxes are between 5 and 10 kW m−2. The inlet quality of the refrigerant in the test section is calculated using the temperature and pressure obtained from the experiment. The pressure drop across the test section is directly measured by a differential pressure transducer. The effects of heat flux, mass flux and, evaporation temperature on the heat transfer coefficients and pressure drop are also discussed. The results from the present experiment are compared with those obtained from the straight tube reported in the literature. New correlations for the convection heat transfer coefficient and pressure drop are proposed for practical applications.  相似文献   

14.
In the present study, the thermal performance and pressure drop of the helical-coil heat exchanger with and without helical crimped fins are studied. The heat exchanger consists of a shell and helically coiled tube unit with two different coil diameters. Each coil is fabricated by bending a 9.50 mm diameter straight copper tube into a helical-coil tube of thirteen turns. Cold and hot water are used as working fluids in shell side and tube side, respectively. The experiments are done at the cold and hot water mass flow rates ranging between 0.10 and 0.22 kg/s, and between 0.02 and 0.12 kg/s, respectively. The inlet temperatures of cold and hot water are between 15 and 25 °C, and between 35 and 45 °C, respectively. The cold water entering the heat exchanger at the outer channel flows across the helical tube and flows out at the inner channel. The hot water enters the heat exchanger at the inner helical-coil tube and flows along the helical tube. The effects of the inlet conditions of both working fluids flowing through the test section on the heat transfer characteristics are discussed.  相似文献   

15.
The shell side heat transfer and pressure drop in counterflowing water were experimentally investigated on the basis of the overall heat transfer coefficient. The investigation was intended to identify ways to get higher performance for the cooler in a BWR nuclear power plant. The following three conclusions were reached in the study. (1) Predicted performance of the heat exchanger, using the overall heat transfer coefficient based on the outside area of the tube Ko, indicated an enhancement by 92% compared with the measured performance of the conventional segmental baffle‐type heat exchanger. (2) The tube side pressure drop ΔPt=20 kPa and the shell side pressure drop ΔPs=70 kPa were obtained, and were within the allowable value ΔPa=80 kPa. The shell side pressure drop of the low‐pressure drop spacer could be decreased by 20% as compared with that of the standard spacer. (3) The enhancement constant of the shell side heat transfer using the low‐pressure drop spacer was about 1.2 times as large as that of the standard spacer, regardless of the pumping power. © 2003 Wiley Periodicals, Inc. Heat Trans Asian Res, 32(5): 455–471, 2003; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.10097  相似文献   

16.
In this study, a comparative study of two different hydrogen redistribution strategies along the Fischer‐Tropsch synthesis reactor using a Pd‐Ag membrane has been carried out. In the first strategy, fresh synthesis gas is flowing in the tube side in co‐current mode with reacting material in shell side so that the first segments of reactor use more hydrogen. In the second strategy, fresh synthesis gas is flowing in the tube side in counter‐current mode with reacting material in shell side so that last segments of reactor use more hydrogen. A one‐dimensional heterogeneous model was developed to compare two strategies from different standpoints. The model was checked using operating data of Fischer‐Tropsch synthesis reactor in pilot plant of Research Institute of Petroleum Industry in Iran. Simulation results show an enhancement in the yield of gasoline production, a decrease in undesired products formation (CO3 and CH4) and also a favorable temperature profile along both the configurations of membrane Fischer‐Tropsch reactor in comparison with conventional reactor. The comparison between co‐current and counter‐current configurations in terms of temperature, gasoline (C) and CO2 yields, H2 and CO conversions, and selectivity of components shows the reactor in the co‐current configuration operates with lower reactants' conversions and also lower permeation rate of hydrogen. On the contrary, our results demonstrated counter‐current‐mode decrease CO2 and CH4 as undesired products, better than other kinds of mentioned systems. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
In this study, fully developed laminar flow and heat transfer in a helically coiled tube with uniform wall temperature have been investigated analytically based on minimal entropy generation principle. The influence of coil curvature ratio and fluid properties, β1 and β2 on the optimum Reynolds number have been investigated for two well-known fluids viz. air and water. It was revealed that optimum Reynolds numbers decrease as curvature ratio increases except in the low ranges of curvature ratio where transition to turbulent flow occurs. In the range of the present study, a correlation predicting optimal Reynolds number was proposed for each fluid using least square analysis.  相似文献   

18.
This paper describes a detailed mathematical model and its application for air-cooled finned-tube CO2 gas coolers. The model has been developed utilizing a distributed method which is necessary to predict accurately the great variation of both refrigerant thermophysical properties and local heat transfer coefficients during CO2 gas cooling processes. The modelling method also enables performance analyses with different circuit arrangements and changed structure parameters in gas coolers to be assessed. The model has been validated with the test results from a published literature by comparing the gas temperature profiles along the coil pipes from refrigerant inlet to outlet at different operating states. With the aim of increasing the heat capacity or minimizing the approach temperature for a gas cooler, the validated model is used to carry out performance simulation and analysis when the circuit arrangement of the original heat exchanger is redesigned. It is found that the approach temperature and the heat capacity are both improved with the increase of heat exchanger circuit numbers.  相似文献   

19.
An experimental investigation has been carried out to study the heat transfer and pressure drop characteristics of nanofluid flow inside horizontal helical tube under constant heat flux. The nanofluid is prepared by dispersion of CuO nanoparticle in base oil and stabilized by means of an ultrasonic device. Nanofluids with different particle weight concentrations of 0.5%, 1% and 2% are used. The effect of different parameters such as flow Reynolds number, fluid temperature and nanofluid particle concentration on heat transfer coefficient and pressure drop of the flow are studied. Observations show that by using the helically coiled tube instead of the straight one, the heat transfer performance is improved. Also, the curvature of the tube will result in the pressure drop enhancement. In addition, the heat transfer coefficient as well as pressure drop is increased by using nanofluid instead of base fluid. Furthermore, the performance evaluation of the two enhanced heat transfer techniques studied in this investigation shows that applying helical tube instead of the straight tube is a more effective way to enhance the convective heat transfer coefficient compared to the second method which is using nanofluids instead of the pure liquid.  相似文献   

20.
Detailed analyses based on mass and energy balances of lignite‐fired air‐blown gasification‐based combined cycles with CO2 pre‐combustion capture are presented and discussed in this work. The thermodynamic assessment is carried out with a proprietary code integrated with Aspen Plus® to carefully simulate the selective removal of both H2S and CO2 in the acid gas removal station. The work focuses on power plants with two combustion turbines, with lower and higher turbine inlet temperatures, respectively, as topping cycle. A high‐moisture lignite, partially dried before feeding the air‐blown gasification system, is used as fuel input. Because the raw lignite presents a very low amount of sulfur, a particular technique consisting of an acid gas recycle to the absorber, is adopted to fulfill the requirements related to the presence of H2S in the stream to the Claus plant and in the CO2‐rich stream to storage. Despite the operation of the H2S removal section representing a significant issue, the impact on the performance of the power plant is limited. The calculations show that a significant lignite pre‐drying is necessary to achieve higher efficiency in case of CO2 capture. In particular, considering a wide range (10–30 wt.%) of residual moisture in the dried lignite, higher heating value (HHV) efficiency presents a decreasing trend, with maximum values of 35.15% and 37.12% depending on the type of the combustion turbine, even though the higher the residual moisture in the dried coal, the lower the extraction of steam from the heat recovery steam cycle. On the other hand, introducing the specific primary energy consumption for CO2 avoided (SPECCA) as a measure of the energy cost related to CO2 capture, lower values were predicted when gasifying dried lignite with higher residual moisture content. In particular, a SPECCA value as low as 2.69 MJ/kgCO2 was calculated when gasifying lignite with the highest (30 wt.%) residual moisture content in a power plant with the advanced combustion turbine. Ultimately, focusing on the power plants with the advanced combustion turbine, air‐blown gasification of lignite brings about a reduction in HHV efficiency equal to almost 1.5 to 2.8 percentage points, depending on the residual moisture in the dried lignite, if compared with similar cases where bituminous coal is used as fuel input. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号