首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Yanhua Lai  Mingxin Lu  Qingwei Wang 《传热工程》2014,35(11-12):1137-1143
Plate-fin and tube heat exchangers are extensively studied both experimentally and numerically. However, data on the fluid flow and heat transfer in the exchanger passage with small diameter tubes have not been accumulated enough. With a large eddy simulation technique (LES), this study performs a detailed investigation of the fluid flow and heat transfer in a plate-and-tube channel with tubes of diameters as small as 5.2 mm. The conservation equations for mass, heat, and momentum were solved by the proposed LES model. It was found that the LES model is appropriate to predict the fluid flow and heat transfer. Compared to heat exchangers of larges tubes, the heat exchangers exhibit much higher heat transfer coefficients with small tubes. The fin efficiencies are improved with small tubes.  相似文献   

2.
Plate heat exchangers are used regularly in the heating, ventilating, air conditioning, and refrigeration industry. There is an urgent need for detailed and systematic research regarding heat transfer and the fluid flow characteristics of these types of exchangers. As an initiative in this respect, a literature search is presented on plate heat exchangers. New correlations for evaporation heat transfer coefficient and friction factor are introduced, which are applicable to various system pressure conditions and plate chevron angles. The correlations are based on actual field data collected during several years of installation and operation of chillers, and they are intended to serve as design tools and perhaps as a starting point for future research.  相似文献   

3.
In the present study, for industrial applications of large inter-coolers employed in multi-stage compressor systems the air-side laminar heat transfer and fluid flow characteristics of plain fin-and-tube heat exchangers with large number of tube rows and large diameter of the tubes are investigated numerically through three-dimensional simulations based on the SIMPLE algorithm in Cartesian coordinates. The effects of parameters such as Reynolds number, the number of tube rows, tube diameter, tube pitches and fin pitch are examined, and the variations of heat transfer due to variations of fin materials are also observed. It is found that the heat transfer and fluid flow approach fully developed conditions when the number of tube rows is greater than six, and the tube diameter as well as the fin pitch have much more significant effects than the tube pitch, and the heat transfer of high-conductivity material is larger than that of low-conductivity material especially in the high Reynolds number regime. Due to the fact that the existing correlations are not valid for large tube diameters and number of tube rows, the heat transfer and flow friction of the presented heat exchangers are correlated in the multiple forms. The correlation is so obtained that it can be used for further studies such as performance prediction or geometrical optimization.  相似文献   

4.
Renewable energy sources like solar energy, wind energy, etc. are profusely available without any limitation. Heat exchanger is a device to transfer the energy from one fluid to other fluid for many applications in buildings, industries and automotives. The optimum design of heat exchanger for minimum pumping power (i.e., minimum pressure drop) and efficient heat transfer is a great challenge in terms of energy savings point of view. This review focuses on the research and developments of compact offset and wavy plate-fin heat exchangers. The review is summarized under three major sections. They are offset fin characteristics, wavy fin characteristics and non-uniformity of the inlet fluid flow. The various research aspects relating to internal single phase flow studied in offset and wavy fins by the researchers are compared and summarized. Further, the works done on the non-uniformity of this fluid flow at the inlet of the compact heat exchangers are addressed and the methods available to minimize these effects are compared.  相似文献   

5.
Abstract

In the search for more compact air/liquid heat exchangers, one possibility is to increase the heat transfer coefficient and surface area by a decrease of the size of the fluid channels. A practical example could be seen in the air/water cross-flow heat exchangers used in cars. For such exchangers, minimization of the total volume leads to a very thin structure, with a lot of small and short air channels. We have designed and patented a cross-flow heat transfer surface with microchannels that has such a structure and can be manufactured industrially at a reasonable cost by extrusion either in aluminum or in polymers. The thermo-hydraulic performance of the structure has been simulated using standard correlations and CFD codes, and prototypic structures are under investigation to validate simulations. Compared to classical heat exchangers, our design is superior in flexibility and compactness for air/liquid applications.  相似文献   

6.
This paper presents an experimental investigation of the thermal performance of a solar air heater having its flow channel packed with Raschig rings. The packing improves the heat transfer from the plate to the air flow underneath. The dimensions of the heater are 0.9 m wide and 1.9 m long. The aluminium‐based absorber plate was coated with ordinary black paint. The characteristic diameter of the Raschig rings, made of black polyvinyl chloride (PVC) tube, is 50 mm and the depth of the packed‐bed in flow channel is 60 mm. Energy and exergy analyses were applied for evaluating the efficiency of the packed‐bed solar air heater. The rate of heat recovered from the packed‐bed solar air heater varied between 9.3 and 151.5 W m?2, while the rate of thermal exergy recovered from the packed‐bed solar air heater varied between 0.04 and 8.77 W m?2 during the charging period. The net energy efficiency varied from 2.05 to 33.78%, whereas the net exergy efficiency ranged from 0.01 to 2.16%. It was found that the average daily net energy and exergy efficiencies were 17.51 and 0.91%, respectively. The energy and exergy efficiencies of the packed‐bed solar air heater increased as the outlet temperature of heat transfer fluid increased. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

7.
This research presents an experimental and numerical study on the heat transfer of α-Al2O3/water nanofluid flowing through the double pipe and shell and tube heat exchangers, under laminar flow conditions. Effects of important parameters such as hot and cold volume flow rates, nanofluid temperature, and nanoparticles concentration on the heat transfer characteristics are investigated. The results indicated that the heat transfer performance of both double pipe and shell and tube heat exchangers increases with increasing the hot and cold volume flow rates, as well as the particle concentrations and nanofluid inlet temperature. Compared with pure water, the results indicated that the heat transfer coefficients of nanofluid in the double pipe and shell and tube heat exchangers are higher than those of water by 13.2% and 21.3%, respectively. Also, the heat transfer performance of nanofluid in a shell and tube heat exchanger is 26.2% higher than the double pipe heat exchanger. A computational fluid dynamics (CFD) technique was used for heat transfer simulation in the previously mentioned heat exchangers. Computed overall heat transfer coefficients of the nanofluids are in good agreement with the experimental data.  相似文献   

8.
The performance of two evaporatively cooled heat exchangers is investigated under similar operating conditions of air flow rates and inlet hot water temperatures. The heat exchangers are plain and plate-finned circular tube types which occupy the same volume. Spray water, which is circulated in a closed circuit, is injected onto the exposed surfaces of the tubes and fins. The contact between air and spray water results in evaporative heat transfer. The tubes are copper, 10 mm o.d. The finned configuration is constructed by introducing 0.5 mm thick copper plates between the tubes, with a total area ratio of four. A substantial increase in heat transfer takes place for the plate-finned tubes. The increase is 92–140% for air velocities from 1.66 to 3.57 m s−1. A model is used to calculate the thermal performance of the plain and finned tubes assuming a constant spray water temperature in the heat exchanger. The wet-finned surfaces show low fin efficiency compared with dry surfaces. An energy index defined as the ratio of volumetric thermal conductance to air pressure drop per unit length is found to be close for the two heat exchangers. This reveals higher thermal utilisation of the occupied volume by the finned tubes with the same energy index.  相似文献   

9.
In this work an artificial neural network (ANN) is used to correlate experimentally determined and numerically computed Nusselt numbers and friction factors of three kinds of fin-and-tube heat exchangers having plain fins, slit fins and fins with longitudinal delta-winglet vortex generators with large tube-diameter and large the number of tube rows. First the experimental data for training the network was picked up from the database of nine samples with tube outside diameter of 18 mm, number of tube rows of six, nine, twelve, and Reynolds number between 4000 and 10,000. The artificial neural network configuration under consideration has twelve inputs of geometrical parameters and two outputs of heat transfer Nusselt number and fluid flow friction factor. The commonly-implemented feed-forward back propagation algorithm was used to train the neural network and modify weights. Different networks with various numbers of hidden neurons and layers were assessed to find the best architecture for predicting heat transfer and flow friction. The deviation between the predictions and experimental data was less than 4%. Compared to correlations for prediction, the performance of the ANN-based prediction exhibits ANN superiority. Then the ANN training database was expanded to include experimental data and numerical data of other similar geometries by computational fluid dynamics (CFD) for turbulent and laminar cases with the Reynolds number of 1000–10,000. This in turn indicated the prediction has a good agreement with the combined database. The satisfactory results suggest that the developed ANN model is generalized to predict the turbulent or/and laminar heat transfer and fluid flow of such three kinds of heat exchangers with large tube-diameter and large number of tube rows. Also in this paper the weights and biases corresponding to the neural network architecture are provided so that future research can be carried out. It is recommended that ANNs might be used to predict the performances of thermal systems in engineering applications, especially to model heat exchangers for heat transfer analysis.  相似文献   

10.
This paper presents the performance evaluation of heat exchangers of an existing naphtha hydrotreating (NHT) plant. Originally, the NHT plant consisted of six plain tube heat exchangers connected in series. During plant revamps operation, three plain tubes were replaced with the three twisted tube heat exchangers. In this study, the heat exchangers data were collected from the plant before and after installation of the three twisted tube heat exchangers. The data were then analyzed to see the effects of the twisted tube configuration on fouling of heat exchangers and heat transfer. The analysis of the data showed that the twisted tube heat exchangers caused reduction in fouling resistance of tubes and increased the heat transfer. Also, the replacement of the three shells and tube type heat exchangers by the twisted tubes resulted in an increase of feed flow rate by about 7.85%. An economic analysis showed that the simple payback period for the twisted tube heat exchangers is 2.12 years. It can be concluded that considerable benefits in terms of energy and cost savings can be realized through the application of this innovative twisted tube heat exchanger technology in existing or new chemical plants.  相似文献   

11.
Over last two decades, plate heat exchangers (PHEs) have presented themselves as a viable alternative to the conventional shell and tube heat exchangers in the process and power industries. The thermal theory available for plate heat exchangers in the literature largely works on the assumption of equal flow in each channel. However, it is well known that the distribution of fluid from port to channel in PHE is far from being uniform. The present study brings about this port to channel flow distribution effect on the thermal behavior of multipass plate heat exchangers. The variation of the heat transfer coefficient due to flow variation from channel to channel has also been taken into consideration. Heat exchangers with both equal and unequal passes of the fluids have been studied. The results indicate that the flow maldistribution severely affects the performance of plate heat exchangers, and multipassing can act as an important tool to reduce the deterioration in performance due to maldistribution. The results show that with a low number of passes, the increase of velocity of fluid may be counterproductive in terms of heat transfer enhancement. Also, adding plates in order to increase the heat transfer surface may not be effective due to an increase in flow maldistribution. The correlations for 1-1, 1-2, 2-2, and 2-3 pass plate heat exchangers with the maldistribution index as a parameter are also presented.  相似文献   

12.
Norbert Kockmann 《传热工程》2017,38(14-15):1316-1330
ABSTRACT

Fluid flow and heat transfer in microchannels is since decades a wide area of vivid research in electronics cooling, compact heat exchangers, or chemical analytics. Fluid dynamics, mixing, and heat transfer are very important for performing exothermic chemical reactions in microchannels under stable and robust conditions. This contribution describes the complex interplay of single and multi-phase flow, residence time, mixing, and heat transfer with chemical kinetics. Dimensionless numbers and typical time scales guide the appropriate design and operation of microstructured equipment and chemical processes. Well-characterized, modular equipment enable short cut methods in the conceptual design phase and allow for consistent scale-up to production scale. The complex correlations are displayed here in a simple fashion with arrows, which can be replaced by relevant equations. The equipment is categorized with a toolbox concept of plate, tube, and vessel on certain platform levels for similar volumetric throughput and process conditions. In addition, separation units are presented for complete chemical process design on laboratory scale. This toolbox enables consistent process development and scale up to small-scale production ranges.  相似文献   

13.
利用三维数值模拟的方法对带有3种异形纵向涡发生器的H型翅片椭圆管换热器的空气侧流动传热特性进行研究。基于H型翅片椭圆管束,讨论了在不同雷诺数下,纵向涡发生器的摆放位置、摆放攻角和形状对空气侧流动传热的影响。研究表明:纵向涡发生器能够将高能量的流体引向流速较低的壁面区域,使冷热流体之间的混合加剧,增强流体的湍流动能,进而达到强化传热的效果;与无纵向涡发生器的管束相比,带纵向涡发生器管束的传热效果有明显的提高;当纵向涡发生器后置时,换热器的传热效果最优;在雷诺数相同,攻角为30°时,流体的传热性能和阻力特性均达到最优;相同攻角摆放时,椭圆角矩形发生器的传热性能和阻力因子均优于其他两种形式的发生器。研究结果为烟气余热回收系统换热器传热性能强化提供理论依据。  相似文献   

14.
This study conducted experiments on the air-side performance of novel L-footed spiral fin-and-tube heat exchangers that were faced with airflow at high Reynolds numbers (3500–13,000). The examined heat exchangers have a multipass parallel-and-counter cross-flow type of water flow arrangement. This flow arrangement is a combination of the parallel cross-flow and the counter cross-flow. This type of water flow arrangement may be the best fit for the reverse-flow system, because it can provide constant heat-exchange effectiveness for every flow reversal direction at the same airflow rate. Ambient air was used as a working fluid on the air side and hot water for the tube side. This way the effect of the number of tube rows on the heat transfer and friction characteristics of L-footed spiral fin-and-tube heat exchangers was clearly observed. The effect of the fin's outside diameter on the pressure drop was also studied. The results show that the number of tube rows has no significant effect on the air-side heat transfer or on friction characteristics at high Reynolds numbers. However, the fin's outside diameter shows a significant effect on the pressure drop. The pressure drop increases as the fin's outside diameter increases for the same number of tube rows.  相似文献   

15.
This paper investigates heat transfer in vertical mantle heat exchangers for application in low flow solar domestic hot water systems. Two new heat transfer correlations for vertical mantle heat exchangers with top entry port and bottom exit ports are developed. The correlations are based on computational fluid dynamic modelling of whole vertical mantle tanks. The correlations are combined with a heat storage model in a simulation program that predicts the yearly thermal performance of low flow solar domestic hot water systems based on mantle tanks. The model predictions of energy gains and temperatures are compared with outdoor measurements and the model is found to give reliable results.  相似文献   

16.
This work presents an experimental analysis of the hydrodynamic and thermal performance of micro-heat exchangers. Two micro-heat exchangers, characterized by microchannels of 100 × 100 and 200 × 200 μm square cross-sections, were designed for that purpose. The fluid used was deionized water and there was no phase change along the fluid circuit. The fluid pressure drop along the heat exchanger and the heat transfer were measured and corrections were made to isolate the contribution of the microchannels. The results were compared with the predictions of the classical viscous flow and heat transfer theory. The main conclusions show that the experimental results fit well with these theories. No effects of heat transfer enhancement or pressure drop increase were observed as a consequence of the small scale of the microchannels.  相似文献   

17.
This paper presents a model for estimating the total cost of shell‐and‐tube heat exchangers (HEs) with condensation in tubes or in the shell, as well as a designing strategy for minimizing this cost. The optimization process is based on a genetic algorithm. The global cost includes the energy cost (i.e. pumping power) and the initial purchase cost of the exchanger. The choice of the best exchanger is based on its annualized total cost. Eleven design variables are optimized. Ten are associated with the HE geometry: tube pitch, tube layout patterns, baffle spacing at the center, baffle spacing at the inlet and outlet, baffle cut, tube‐to‐baffle diametrical clearance, shell‐to‐baffle diametrical clearance, tube bundle outer diameter, shell diameter, and tube outer diameter. The last design variable indicates whether the condensing fluid should flow in the tubes or in the shell. Two case studies are presented and the results obtained show that the procedure can rapidly identify the best design for a given heat transfer process between two fluids, one of which is condensing. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
《Applied Thermal Engineering》2000,20(14):1271-1282
Research has been carried out on the theory, design and construction of heat pipes, especially their use in heat pipe heat exchangers for energy recovery, reduction of air pollution and environmental conservation. A heat pipe heat exchanger has been designed and constructed for heat recovery in hospital and laboratories, where the air must be changed up to 40 times per hour. In this research, the characteristic design and heat transfer limitations of single heat pipes for three types of wick and three working fluids have been investigated, initially through computer simulation. Construction of heat pipes, including washing, inserting the wick, creating the vacuum, injecting the fluid and installation have also been carried out. After obtaining the appropriate heat flux, the air-to-air heat pipe heat exchanger was designed, constructed and tested under low temperature (15–55°C) operating conditions, using methanol as the working fluid. Experimental results for absorbed heat by the evaporator section are very close to the heat transfer rate obtained from computer simulation. Considering the fact that this is one of the first practical applications of heat pipe heat exchangers, it has given informative results and paved the way for further research.  相似文献   

19.
The unsteady behaviors of fluid flow and heat transfer in plain plate-fin and tube heat exchangers with a wide range of fin spacings from 2.06 mm to 16.48 mm and tube diameter 8.28 mm are studied by a large eddy simulation technique (LES). Velocity fluctuations and vortex sheddings induced by the tubes in the channel are modeled. The results found that the flow in passages of large spacings is quite different from that of small spacings. The flow is co-determined by two effects: the duct effect and the tube bank effect. The tube bank effect is more dominant with increasing fin spacings.  相似文献   

20.
Air-side heat transfer and friction characteristics of nine kinds of fin-and-tube heat exchangers, with a large number of tube rows (6, 9, and 12, respectively) and large diameter of tubes (18 mm), are experimentally investigated. The test samples consist of three types of fin configurations: plain fin, slit fin, and fin with delta-wing longitudinal vortex generators. The working fluid in the tube is steam. Results show that when the number of tube is larger than 6, the heat transfer and friction performance for three kinds of fins is independent of the number of tube rows, and slit fin provides higher heat transfer and pressure drop than the other two fins. The heat transfer and friction factor correlations for all the heat exchangers were acquired with Reynolds numbers ranging from 4000 to 10000. The air-side performance of heat exchangers with plain fin, slit fin, and longitudinal vortex-generator fin were evaluated under three sets of criteria, and the results showed that the heat exchanger with slit fin has better performance than that with vortex-generator fin, especially at high Reynolds numbers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号