1.
This paper focuses on novel integration of high temperature solid oxide fuel cell coupled with recuperative gas turbine (with air-film cooling of blades) based hybrid power plant (SOFC-blade cooled GT). For realistic analysis of gas turbine cycle air-film blade cooling technique has been adopted. First law thermodynamic analysis investigating the combine effect of film cooling of blades, SOFC, applied to a recuperated gas turbine cycle has been reported. Thermodynamic modeling for the proposed cycle has been presented. Results highlight the influence of film cooling of blades and operating parameters of SOFC on various performance of SOFC-blade cooled GT based hybrid power plant. Moreover, parametric investigation has also been done to examine the effect of compressor pressure ratio, turbine inlet temperature, on hybrid plant efficiency and plant specific work. It has been found that on increasing turbine inlet temperature (TIT) beyond a certain limit, the efficiency of gas turbine starts declining after reaching an optimum value which is compensated by continuous increase in SOFC efficiency with increase in operating temperature. The net result is higher performance of hybrid cycle with increase in maximum cycle temperature. Furthermore, it has been observed that at TIT 1600 K and compression ratio 20, maximum efficiency of 73.46% can been achieved.  相似文献   

2.
For a solid oxide fuel cell (SOFC) integrated into a micro gas turbine (MGT) hybrid power system, SOFC operating temperature and turbine inlet temperature are the key parameters, which affect the performance of the hybrid system. Thus, a least squares support vector machine (LS-SVM) identification model based on an improved particle swarm optimization (PSO) algorithm is proposed to describe the nonlinear temperature dynamic properties of the SOFC/MGT hybrid system in this paper. During the process of modeling, an improved PSO algorithm is employed to optimize the parameters of the LS-SVM. In order to obtain the training and prediction data to identify the modified LS-SVM model, a SOFC/MGT physical model is established via Simulink toolbox of MATLAB6.5. Compared to the conventional BP neural network and the standard LS-SVM, the simulation results show that the modified LS-SVM model can efficiently reflect the temperature response of the SOFC/MGT hybrid system.  相似文献   

3.
Solid oxide fuel cell (SOFC) integrated into micro gas turbine (MGT) cycle is a promising power‐generation technology. This article proposes a modified output–input feedback (OIF) Elman neural network model to describe the nonlinear temperature and power dynamic properties of the SOFC/MGT hybrid system. A physics‐based mathematical model of a 220 kW SOFC/MGT hybrid power system is used to generate the data required for the training and prediction of the modified OIF Elman neural network identification model. Compared with the conventional Elman neural network, the simulation results show that the modified OIF Elman identification model can follow the temperature and power response of the SOFC/MGT hybrid system with higher prediction accuracy and faster convergent speed. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
In this paper, the performance evaluation of a solid oxide fuel cell (SOFC)–micro gas turbine (MGT) hybrid power generation system under the part-load operation was studied numerically. The present analysis code includes distributed parameters model of the cell stack module. The conversions of chemical species for electrochemical process and fuel reformation process are considered. Besides the temperature distributions of the working fluids and each solid part of cell module by accounting heat generation and heat transfers, are taken into calculation. Including all of them, comprehensive energy balance in the cell stack module is calculated. The variable MGT rotational speed operation scheme is adopted for the part-load operation. It will be made evident that the power generation efficiency of the hybrid system decreases together with the power output. The major reason for the performance degradation is the operating temperature reduction in the SOFC module, which is caused by decreasing the fuel supply and the heat generation in the cells. This reduction is also connected to the air flow rate supplement. The variable MGT rotational speed control requires flexible air flow regulations to maintain the SOFC operating temperature. It will lead to high efficient operation of the hybrid system.  相似文献   

5.
We present a steady‐state thermodynamic model of a hybrid solid oxide fuel cell (SOFC)–gas turbine (GT) cycle developed using a commercial process simulation software, AspenPlus?. The hybrid cycle model incorporates a zero‐dimensional macro‐level SOFC model. A parametric study was carried out using the developed model to study the effects of system pressure, SOFC operating temperature, turbine inlet temperature, steam‐to‐carbon ratio, SOFC fuel utilization factor, and GT isentropic efficiency on the specific work output and efficiency of a generic hybrid cycle with and without anode recirculation. The results show that system pressure and SOFC operating temperature increase the cycle efficiency regardless of the presence of anode recirculation. On the other hand, the specific work decreases with operating temperature. Overall, the model can successfully capture the complex performance trends observed in hybrid cycles. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
Integrating fuel cells with conventional gas turbine based power plant yields higher efficiency, especially solid oxide fuel cell (SOFC) with gas turbine (GT). SOFCs are energy efficient devices, performance of which are not limited to Carnot efficiency and considered as most promising candidate for thermal integration with Brayton cycle. In this paper, a novel and optimal thermal integration of SOFC with intercooled-recuperated gas turbine has been presented. A thermodynamic model of a proposed hybrid cycle has been detailed along with a novelty of adoption of blade cooled gas turbine model. On the basis of 1st and 2nd law of thermodynamics, parametric analysis has been carried out, in which impact of turbine inlet temperature and compression ratio has been observed on various output parameters such as hybrid efficiency, hybrid plant specific work, mass of blade coolant requirement and entropy generation rate. For optimizing the system performance, entropy minimization has been carried out, for which a constraint based algorithm has been developed. The result shows that entropy generation of a proposed hybrid cycle first increases and then decreases, as the turbine inlet temperature of the cycle increases. Furthermore, a unique performance map has also been plotted for proposed hybrid cycle, which can be utilized by power plant designer. An optimal efficiency of 74.13% can be achieved at TIT of 1800 K and rp,c 20.  相似文献   

7.
For a solid oxide fuel cell (SOFC) and micro gas turbine (MGT) hybrid system, optimal control of load changes requires optimal dynamic scheduling of set points for the system's controllers. Thus, this paper proposes an improved iterative particle swarm optimization (PSO) algorithm to optimize the operating parameters under various loads. This method combines the iteration method and the PSO algorithm together, which can execute the discrete PSO iteratively until the control profile would converge to an optimal one. In MATLAB environment, the simulation results show that the SOFC/MGT hybrid model with the optimized parameters can effectively track the output power with high efficiency. Hence, the improved iterative PSO algorithm can be helpful for system analysis, optimization design, and real‐time control of the SOFC/MGT hybrid system. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

8.
Optimization is an important method for improving the efficiency and power of the combined cycle. In this paper, the triple‐pressure steam‐reheat gas‐reheat gas‐recuperated combined cycle that uses steam for cooling the first gas turbine (the regular steam‐cooled cycle) was optimized relative to its operating parameters. The optimized cycle generates more power and consumes more fuel than the regular steam‐cooled cycle. An objective function of the net additional revenue (the saving of the optimization process) was defined in terms of the revenue of the additional generated power and the costs of replacing the heat recovery steam generator (HRSG) and the costs of the additional operation and maintenance, installation, and fuel. Constraints were set on many operating parameters such as air compression ratio, the minimum temperature difference for pinch points (δTppm), the dryness fraction at steam turbine outlet, and stack temperature. The net additional revenue and cycle efficiency were optimized at 11 different maximum values of turbine inlet temperature (TIT) using two different methods: the direct search and the variable metric. The optima were found at the boundaries of many constraints such as the maximum values of air compression ratio, turbine outlet temperature (TOT), and the minimum value of stack temperature. The performance of the optimized cycles was compared with that for the regular steam‐cooled cycle. The results indicate that the optimized cycles are 1.7–1.8 percentage points higher in efficiency and 4.4–7.1% higher in total specific work than the regular steam‐cooled cycle when all cycles are compared at the same values of TIT and δTppm. Optimizing the net additional revenue could result in an annual saving of 21 million U.S. dollars for a 439 MW power plant. Increasing the maximum TOT to 1000°C and replacing the stainless steel recuperator heat exchanger of the optimized cycle with a super‐alloys‐recuperated heat exchanger could result in an additional efficiency increase of 1.1 percentage point and a specific work increase of 4.8–7.1%. The optimized cycles were about 3.3 percentage points higher in efficiency than the most efficient commercially available H‐system combined cycle when compared at the same value of TIT. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

9.
This paper contributes a novel sustainability index and modified exergy indicators for conventional gas turbines and solid oxide fuel cell integrated gas turbine (SOFC-GT) hybrid power cycles. In this work, an intercooled gas turbine (Ic-GT) cycle is considered as a base cycle, which gives an additive advantage in lowering the power required for the compressor. Moreover, on SOFC integration with Ic-GT, the qualitative and quantitative performance are examined. Numerical modeling is done using MATLAB and an exclusive comparison has been made based on energy-exergy and sustainability analysis for the system and its components. On comparing the first law efficiency at turbine inlet temperature, TIT 1250K and rp = 18 for Ic-GT, intercooled recuperated gas turbine (Ic-RGT), and Ic–SOFC–RGT, it is 25.82%, 36.04%, and 64.78%, respectively. Similarly, second law efficiency is 11.43%, 22.33%, and 61.11% and the overall sustainability index is 1.12, 1.28, and 2.57 for Ic-GT, Ic-RGT, and Ic–SOFC–RGT, respectively. Nine other modified exergy-based parameters are used to identify the role of fuel and product exergy and then compare the most affected component in three configurations.  相似文献   

10.
An energy analysis of three typical solid oxide fuel cell (SOFC) power systems fed by methane is carried out with detailed thermodynamic model. Simple SOFC system, hybrid SOFC‐gas turbine (GT) power system, and SOFC‐GT‐steam turbine (ST) power system are compared. The influences of air ratio and operative pressure on the performance of SOFC power systems are investigated. The net system electric efficiency and cogeneration efficiency of these power systems are given by the calculation model. The results show that internal reforming SOFC power system can achieve an electrical efficiency of more than 49% and a system cogeneration efficiency including waste heat recovery of 77%. For SOFC‐GT system, the electrical efficiency and cogeneration efficiency are 61% and 80%, respectively. Although SOFC‐GT‐ST system is more complicated and has high investment costs, the electrical efficiency of it is close to that of SOFC‐GT system. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
This study presents an energetic performance analysis for a combined power generation system consisting of a solid oxide fuel cell (SOFC) and an organic Rankine cycle (ORC). In order to simulate the SOFC–ORC combined system under steady‐state conditions, a mathematical model is developed. The developed model is used to determine the potential effects caused by the changes of the design parameters on the energetic performance of the combined system. As design parameters, turbine inlet pressure, condenser temperature, fuel utilization, current density, compressor pressure ratio, and cell operating temperature are taken into account. In this regard, the electrical power and First Law efficiency are estimated by parametrical analysis and discussed comprehensively. Results of these analyses show that the efficiency is increased about 14–25% by recovering SOFC waste heat through ORC based on investigated design parameter conditions. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
A parametric study is conducted on a hybrid SOFC-GT cycle as part of a national program aiming to improve the efficiency of the actual gas turbine power plants and to better undertake the future investigations. The proposed power plant is mainly constituted by a Gas Turbine cycle, a SOFC system, and an ammonia water absorption refrigerating system. An external pre-reformer is installed before the SOFC. Heat recovery systems are adopted to valorize the waste heat at the SOFC and GT exhausts. The gas from the SOFC exhaust is also used as additional supply for the combustion chamber. An extraction is performed on the gas Turbine in order to feed the SOFC cycle by thermal heat flux at medium pressure.The equations governing the electrochemical processes, the energy and the exergy balances of the power plant components are established. Numerical simulation using EES software is performed. The influences of key operating parameters, such as humidity, pre-reforming fraction, extraction fraction from the Gas Turbine and fuel utilization on the performances of the SOFC-GT hybrid system are analyzed. Obtained results show that the integration of the SOFC enhances significantly the hybrid overall cycle efficiency. The increase of the ambient temperature and humidity reduces the system efficiencies. The utilization factor has a negative effect on the SOFC temperature and voltage. That leads to a decrease in the power plant performances. While the pre-reforming fraction, has a positive effect on the indicated parameters.  相似文献   

13.
Using fuel cell systems for distributed generation (DG) applications represents a meaningful candidate to conventional plants due to their high power density and the heat recovery potential during the electrochemical reaction. A hybrid power system consisting of a proton exchange membrane (PEM) fuel cell stack and an organic Rankine cycle (ORC) is proposed to utilize the waste heat generated from PEM fuel cell. The system performance is evaluated by the steady-state mathematical models and thermodynamic laws. Meanwhile, a parametric analysis is also carried out to investigate the effects of some key parameters on the system performance, including the fuel flow rate, PEM fuel cell operating pressure, turbine inlet pressure and turbine backpressure. Results show that the electrical efficiency of the hybrid system combined by PEM fuel cell stack and ORC can be improved by about 5% compared to that of the single PEM fuel cell stack without ORC, and it is also indicated that the high fuel flow rate can reduce the PEM fuel cell electrical efficiency and overall electrical efficiency. Moreover, with an increased fuel cell operating pressure, both PEM fuel cell electrical efficiency and overall electrical efficiency firstly increase, and then decrease. Turbine inlet pressure and backpressure also have effects on the performance of the hybrid power system.  相似文献   

14.
In this study, the performance of ideal open cycle gas turbine system was examined based on its thermodynamic analysis. The effects of some parameters, such as compressor inlet temperature (CIT), pressure ratio (PR) and the turbine inlet temperature (TIT), on the performance parameters of open cycle gas turbine were discussed. The turbine net power output, the thermal efficiency and the fuel consumption of the turbine were taken as the performance parameters. The values of these parameters were calculated using some basic cycle equations and variables values of thermodynamic properties. Other variables such as lower heating value, combustion efficiency and isentropic efficiencies of compressor and turbine were assumed to be constant. The result showed that the net power output and the thermal efficiency increased by a decrease in the CIT and increase in the TIT and PR values. If it is aimed to have a high net power output and the thermal efficiency for the turbine, the CIT should be chosen as low as possible and the TIT should be chosen as high as possible. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
A novel solid oxide fuel cell (SOFC)/gas turbine (GT) hybrid cycle system with CO2 capture is proposed based on a typical topping cycle SOFC/GT hybrid system. The H2 gas is separated from the outlet mixture gas of SOFC1 anode by employing the advanced ceramic proton membrane technology, and then, it is injected into SOFC2 to continue a new electrochemical reaction. The outlet gas of SOFC1 cathode and the exhaust gas from SOFC2 burn in the afterburner 1. The combustion gas production of the afterburner1 expands in the turbine 1. The outlet gas of SOFC1 anode employs the oxy‐fuel combustion mode in the afterburner 2 after H2 gas is separated. Then, the combustion gas production expands in the turbine 2. To ensure that the flue gas temperature does not exceed the maximum allowed turbine inlet temperature, steam is injected into the afterburner 2. The outlet gas of the afterburner 2 contains all the CO2 gas of the system. When the steam is removed by condensation, the CO2 gas can be captured. The steam generated by the waste heat boiler is used to drive a refrigerator and make CO2 gas liquefied at a lower temperature. The performance of the novel quasi‐zero CO2 emission SOFC/GT hybrid cycle system is analyzed with a case study. The effects of key parameters, such as CO2 liquefaction temperature, hydrogen separation rate, and the unit oxygen production energy consumption on the new system performance, are investigated. Compared with the other quasi‐zero CO2 emission power systems, the new system has the highest efficiency of around 64.13%. The research achievements will provide the valuable reference for further study of quasi‐zero CO2 emission power system with high efficiency. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
Cycle simulation and analysis for two kinds of SOFC/GT hybrid systems were conducted with the help of the simulation tool: Aspen Custom Modeler. Two cycle schemes of recuperative heat exchanger (RHE) and exhaust gas recirculated (EGR) were described according to the air reheating method. The system performance with operating pressure, turbine inlet temperature and fuel cell load were studied based on the simulation results. Then the effects of oxygen utilization, fuel utilization, operating temperature and efficiencies of the gas turbine components on the system performance of the RHE cycle and the EGR cycle were discussed in detail. Simulation results indicated that the system optimum efficiency for the EGR air reheating cycle scheme was higher than that of the RHE cycle system. A higher pressure ratio would be available for the EGR cycle system in comparison with the RHE cycle. It was found that increasing fuel utilization or oxygen utilization would decrease fuel cell efficiency but improve the system efficiency for both of the RHE and EGR cycles. The efficiency of the RHE cycle hybrid system decreased as the fuel cell air inlet temperature increased. However, the system efficiency of EGR cycle increased with fuel cell air inlet temperature. The effect of turbine efficiency on the system efficiency was more obvious than the effect of the compressor and recuperator efficiencies among the gas turbine components. It was also indicated that improving the gas turbine component efficiencies for the RHE cycle increased system efficiency higher than that for the EGR cycle.  相似文献   

17.
A methodology to improve the performance of a hybrid solid oxide fuel cell gas turbine (SOFC‐GT) system for the whole operating range is proposed. The method suggests a way to estimate the geometric parameters of the turbomachinery components for a hybrid SOFC‐GT system. It is based on the search of the compressor and turbine operating lines giving the optimum system efficiency both in design and part load operation. Turbomachinery models are used to calculate the geometry that produces the desired performance maps and the corresponding operating lines. Based on the new turbomachinery design, the hybrid system shows a clear efficiency advantage for the whole operating range. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
Power generation using gas turbine (GT) power plants operating on the Brayton cycle suffers from low efficiencies, resulting in poor fuel to power conversion. A solid oxide fuel cell (SOFC) is proposed for integration into a 10 MW gas turbine power plant, operating at 30% efficiency in order to improve system efficiencies and economics. The SOFC system is semi-directly coupled to the gas turbine power plant, with careful attention paid to minimize the disruption to the GT operation. A thermo-economic model is developed for the hybrid power plant, and predicts an optimized power output of 21.6 MW at 49.2% efficiency. The model also predicts a breakeven per-unit energy cost of USD 4.70 ¢/kWh for the hybrid system based on futuristic mass generation SOFC costs. Results show that SOFCs can be semi-directly integrated into existing GT power systems to improve their thermodynamic and economic performance.  相似文献   

19.
Solid oxide fuel cell and micro gas turbine (SOFC/MGT) hybrid system is a promising distributed power technology. In order to ensure the system safe operation as well as long lifetime of the fuel cell, an effective control manner is expected to regulate the temperature and fuel utilization at the desired level, and track the desired power output. Thus, a multi-loop control strategy for the hybrid system is investigated in this paper. A mathematical model for the SOFC/MGT hybrid system is built firstly. Based on the mathematical model, control cycles are introduced and their design is discussed. Part load operation condition is employed to investigate the control strategies for the system. The dynamic modeling and control implementation are realized in the MATLAB/SIMULINK environment, and the simulation results show that it is feasible to build the multi-loop control methods for the SOFC/MGT hybrid system with regard to load disturbances.  相似文献   

20.
Solid oxide fuel cell(SOFC) vehicles are considered to have broad prospects for development, and the high operating temperature of SOFC results in great potential for waste-heat recovery. Many concepts for utilizing waste heat of SOFC have been suggested and studied, and most of them directly couple an SOFC to a gas turbine, which require the SOFC to operate at an elevated pressure and make the system less flexible and thus harder to operate. In recent years, with the development of turbine and heat exchanger technology, the supercritical carbon dioxide(S-CO_2) power cycle has raised widespread attractions for the waste recovery. This study explores the potential of S-CO_2 Brayton cycle to realize waste-heat recovery for an SOFC vehicle. The SOFC can operate at atmospheric pressure, and the hybrid system is easier to operate than the directly coupled systems. In this paper, a simple recuperated S-CO_2 Brayton cycle is proposed and the key component, radial inflow turbine is designed and focused. The flow state of the designed turbine is analyzed in detail based on computational fluid dynamics(CFD) numerical simulation. Five cases with different impeller tip clearances are numerically simulated to study its influence on the turbine performance. In addition, off-design performance analysis of the radial inflow turbine is conducted considering the temperature fluctuation of SOFC in practical applications.  相似文献   