1.
Human response to air movement supplied locally towards the face was studied in a room with an air temperature of 20 °C and a relative humidity of 30%. Thirty-two human subjects were exposed to three conditions: calm environment and facially supplied airflow at 21 °C and at 26 °C. The air was supplied with a constant velocity of 0.4 m/s by means of personalized ventilation towards the face of the subjects. The airflow at 21 °C decreased the subjects' thermal sensation and increased draught discomfort, but improved slightly the perceived air quality. Heating of the supplied air by 6 K (temperature increase by 4 K at the target area) above the room air temperature decreased the draught discomfort, improved subjects' thermal comfort and only slightly decreased the perceived air quality. Elevated velocity and temperature of the localized airflow caused an increase of nose dryness intensity and number of eye irritation reports. Results suggest that increasing the temperature of the air locally supplied to the breathing zone by only a few degrees above the room air temperature will improve occupants' thermal comfort and will diminish draught discomfort. This strategy will extend the applicability of personalized ventilation aiming to supply clean air for breathing at the lower end of the temperature range recommended in the standards. Providing individual control is essential in order to avoid discomfort for the most sensitive occupants.  相似文献   

2.
Recently, studies suggest that the average indoor temperature is typically >30°C and that the maximum temperature can reach 37.5°C in hot-humid areas. However, the effects caused by increasing the humidity at high indoor temperatures are not clear. In this study, twelve female and twelve male subjects were exposed to different operative temperature (26.6, 30.6, and 37.4°C) and relative humidity (50% and 70%) in a climate chamber. Data concerning thermal sensation, perceived air quality, and Sick Building Syndrome (SBS) were collected during 190-min-long exposure to each thermal condition. Heart rate, respiration rate, respiratory ventilation rate, mean skin temperature, and eardrum temperature were measured. It was found that increasing the relative humidity from 50% to 70% at 26 and 30°C had no significant effects on the physiological responses, thermal comfort, perceived air quality, or SBS symptoms of the subjects. However, when the temperature was elevated to 37°C, the heart rate, respiration rate, respiratory ventilation rate, mean skin temperature, and eardrum temperature increased significantly as a result of the increase in the relative humidity from 50% to 70%. The subjects felt hotter and more uncomfortable, and they found indoor air quality was more difficult to accept. The subjects are acclimatized to hot environments and more tolerant to heat. Therefore, the results are applicable to the acclimated people living in hot-humid climate.  相似文献   

3.
To investigate the effect of air-conditioning parameters (including temperature, relative humidity and air velocity) and deposition dust on microbial growth in supply air duct, a complete test facility according to ASHRAE Standard 62.1-2007 was constructed. A series of experiments for testing microbial concentration (including bacteria and fungus) were conducted under different working conditions (such as different temperatures and relative humidity). The air velocity was constantly kept at 2.0 m/s. Orthogonal design was employed for the analysis of test data. The results indicated that air velocity attenuation down the direction of the supply air affected dust distribution at the bottom of duct, to some extent, and the number of microorganisms was positively correlated with the quantity of dust. In the range of temperature 22-32 °C and relative humidity (RH) 40-90%, microbial growth significantly accelerated with higher temperature and RH increasing. The organic compounds composing the dust also had great impact on microbial growth. The basic researches are contributed to control the growth of microorganism and improve the indoor microenvironment in the air-conditioning room.  相似文献   

4.
Xia YZ  Niu JL  Zhao RY  Burnett J 《Indoor air》2000,10(4):289-296
Air movement can provide desirable cooling in "warm" conditions, but it can also cause discomfort. This study focuses on the effects of turbulent air movements on human thermal sensations through investigating the preferred air velocity within the temperature range of 26 degrees C and 30.5 degrees C at two relative humidity levels of 35% and 65%. Subjects in an environmental chamber were allowed to adjust air movement as they liked while answering a series of questions about their thermal comfort and draft sensation. The results show that operative temperature, turbulent intensity and relative humidity have significant effects on preferred velocities, and that there is a wide variation among subjects in their thermal comfort votes. Most subjects can achieve thermal comfort under the experimental conditions after adjusting the air velocity as they like, except at the relative high temperature of 30.5 degrees C. The results also indicate that turbulence may reduce draft risk in neutral-to-warm conditions. The annoying effect caused by the air pressure and its drying effect at higher velocities should not be ignored. A new model of Percentage Dissatisfied at Preferred Velocities (PDV) is presented to predict the percentage of feeling draft in warm isothermal conditions.  相似文献   

5.
In a warm and humid climate, increasing the temperature set point offers considerable energy benefits with low first costs. Elevated air movement generated by a personally controlled fan can compensate for the negative effects caused by an increased temperature set point. Fifty‐six tropically acclimatized persons in common Singaporean office attire (0.7 clo) were exposed for 90 minutes to each of five conditions: 23, 26, and 29°C and in the latter two cases with and without occupant‐controlled air movement. Relative humidity was maintained at 60%. We tested thermal comfort, perceived air quality, sick building syndrome symptoms, and cognitive performance. We found that thermal comfort, perceived air quality, and sick building syndrome symptoms are equal or better at 26°C and 29°C than at the common set point of 23°C if a personally controlled fan is available for use. The best cognitive performance (as indicated by task speed) was obtained at 26°C; at 29°C, the availability of an occupant‐controlled fan partially mitigated the negative effect of the elevated temperature. The typical Singaporean indoor air temperature set point of 23°C yielded the lowest cognitive performance. An elevated set point in air‐conditioned buildings augmented with personally controlled fans might yield benefits for reduced energy use and improved indoor environmental quality in tropical climates.  相似文献   

6.
The effect of vertical air temperature gradient on overall and local thermal comfort at different overall thermal sensations and room air temperatures (at 0.6 m height) was investigated in a room served by displacement ventilation system. Sixty tropically acclimatized subjects performed sedentary office work for a period of 3 h during each session of the experiment. Nominal vertical air temperature gradients between 0.1 and 1.1 m heights were 1, 3 and 5 K/m while nominal room air temperatures at 0.6 m height were 20, 23 and 26 °C. Air velocity in the space near the subjects was kept at below 0.2 m/s. Relative humidity at 0.6 m height was maintained at 50%. It was found that temperature gradient had different influences on thermal comfort at different overall thermal sensations. At overall thermal sensation close to neutral, only when room air temperature was substantially low, such as 20 °C, percentage dissatisfied of overall body increased with the increase of temperature gradient. At overall cold and slightly warm sensations, percentage dissatisfied of overall body was non-significantly affected by temperature gradient. Overall thermal sensation had significant impact on overall thermal comfort. Local thermal comfort of body segment was affected by both overall and local thermal sensations.  相似文献   

7.
The effect of personalized ventilation (PV) on people's health, comfort, and performance in a warm and humid environment (26 and 28°C at 70% relative humidity) was studied and compared with their responses in a comfortable environment (23°C and 40% relative humidity). Thirty subjects participated in five 4‐h experiments in a climate chamber. Under the conditions with PV, the subjects were able to control the rate and direction of the supplied personalized flow of clean air. Subjective responses were collected through questionnaires. During all exposures, the subjects were occupied with tasks used to assess their performance. Objective measures of tear film stability, concentration of stress biomarkers in saliva, and eye blinking rate were taken. Using PV significantly improved the perceived air quality (PAQ) and thermal sensation and decreased the intensity of Sick Building Syndrome (SBS) symptoms to those prevailing in a comfortable room environment without PV. Self‐estimated and objectively measured performance was improved. Increasing the temperature and relative humidity, but not the use of PV, significantly decreased tear film quality and the concentration of salivary alpha‐amylase, indicating lower mental arousal and alertness. The use of PV improved tear film stability as compared to that in a warm environment without PV.  相似文献   

8.
This research shows the result of a brainstorming by medical experts in the first ranking university medical school and hospital of Thailand. It was based on Delphi technique. The objective of this research was to study both direct and indirect effects of humidity and temperature on human health in air-conditioned buildings in Thailand. Afterwards, the result was used to design and develop split type air conditioner (conventional air conditioner) which could control relative humidity and temperature with precision air conditioning system to comply with the climate and the suitability of the people living in Thailand building. The result of operation with precision inverter air conditioning system showed that the temperature inside the room changed from the default value around ±0.2 °C (Case 1) and around ±0.35 °C (Case 2) and it could control relative humidity as a desired condition between 50-60% (both cases) which was the appropriate range for Thai climate. Moreover, energy consumption of precision inverter air conditioning system was still less than conventional air conditioning system for about 7.5%. This research could provide people living in Thailand air conditioned building with human thermal comfort and health.  相似文献   

9.
In this study, we examined the cognitive performance of subtropically acclimatized subjects at an extreme high indoor temperature and the effect of decreased humidity on the cognitive performance at the high temperature. Forty-eight healthy subjects experienced the three exposure conditions: 26°C/relative humidity (RH) 70%, 39°C/RH50%, and 39°C/RH70% in a climate chamber. During 140-minute-long exposures to each thermal condition, they were required to perform cognitive tests that assess the perception, spatial orientation, concentration, memory, and thinking abilities. Meanwhile, their heart rate, core temperature, skin temperature, blood pressure, and body weight were measured and subjective responses, that is, thermal comfort, perceived air quality, and acute health symptoms were investigated. At the relative humidity of 70%, increasing indoor temperature from 26°C to 39°C caused a significant decrease in the accuracy of these cognitive tests. However, when the relative humidity decreased from 70% to 50% at 39°C, the accuracy of the cognitive tests increased significantly. Accordingly, the physiological and subjective responses of the subjects changed significantly with the changes in indoor temperature and humidity, which provided a basis to the variation in the cognitive performance. These results indicated that decreasing indoor humidity at extreme high temperature could improve the impaired cognitive performance.  相似文献   

10.
A series of ventilation, thermal and indoor air quality measurements were performed in 14 different dairy buildings in Estonia and Finland. The number of animals in the buildings varied from 30 to 600. Measurements were made all year round with ambient temperatures ranging between −40 °C and +30 °C. The results showed that microclimatic conditions in the dairy buildings were affected by the design of the building, outside temperature, wind, ventilation and manure handling method. The average inside air concentration of carbon dioxide was 950 ppm, ammonia 5 ppm, methane 48 ppm, relative humidity 70% and inside air velocity was 0.2 m/s. Although occasionally exceeded, the ventilation and average indoor air quality in the dairy buildings were mainly within the recommended limits.  相似文献   

11.
This paper presents a study of Perceived Air Quality (PAQ) and Sick Building Syndrome (SBS) using tropically acclimatized subjects in a Field Environmental Chamber (FEC) served by Displacement Ventilation (DV) system. The FEC, 11.12 m (L)×7.53 m (W)×2.60 m (H), simulates a typical office layout. A total of 60 subjects, 30 males and 30 females, were engaged in sedentary office work for 3 h. Air velocity in the space near the subjects was kept at below 0.2 m/s. Relative Humidity (RH) at 0.6 m height and outdoor air provision were maintained at 50% and 10 l/s/p, respectively. Subjects were exposed to three vertical air temperature gradients, nominally 1, 3 and 5 K/m, between 0.1 and 1.1 m heights and three room air temperatures 20, 23 and 26 °C at 0.6 m height. The main objective of this study is to evaluate the influence of temperature gradient and room air temperature (at 0.6 m height) on PAQ and SBS in DV environment. It was found that temperature gradient had insignificant impact on PAQ and SBS. Dry air sensation, irritations and air freshness decreased with increase of room air temperature.  相似文献   

12.
In China, adding space heating in residential buildings is normally scheduled at the end of October each year, with heat supplied by district heating systems. This paper describes a field study of thermal comfort conducted in Harbin during the winter from 2009 to 2010 before and after the space heating is added. The aim is to study human responses to thermal conditions in the two periods in cold climates. 23 buildings in six communities were investigated. 199 occupants from 135 families and 174 occupants from 104 families participated in the two surveys during the two periods, respectively. The neutral air temperature before adding the space heating is 25.1 °C, while during the space heating, it is 20.4 °C. The clothing insulation is 0.77 clo and 0.88 clo, respectively. If they were 0.88 clo instead of 0.77 clo before adding the space heating, the neutral air temperature should be 21.1 °C. Before and during space heating, more than 80% felt acceptable at the air temperature range between 17.5–24.0 °C and 19.0–26.5 °C for the two periods. The residents’ physiological acclimation may contribute to the differences. The preferred temperature is within the range of 23.0–24.0 °C and 21.5–24.0 °C, respectively. The preferred humidity is 47.7% and 40.5% during the two surveys. People felt cold generally before heating, while they felt comfortable at the same temperature range during space heating period. People often felt dry during heating when the relative humidity is lower than 30%, while they felt comfortable at the same relative humidity before heating.  相似文献   

13.
In the ASHRAE comfort database [1], underpinning the North American naturally ventilated adaptive comfort standard [2], the mean indoor air velocity associated with 90% thermal acceptability was relatively low, rarely exceeding 0.3 m/s. Post hoc studies of this database showed that the main complaint related to air movement was a preference for ‘more air movement’ 3 and 4. These observations suggest the potential to shift thermal acceptability to even higher operative temperature values, if higher air speeds are available. If that were the case, would it be reasonable to expect temperature and air movement acceptability levels at 90%? This paper focuses on this question and combines thermal and air movement acceptability percentages in order to assess occupants. Two field experiments took place in naturally ventilated buildings located on Brazil’s North-East. The fundamental feature of this research design is the proximity of the indoor climate observations with corresponding comfort questionnaire responses from the occupants. Almost 90% thermal acceptability was found within the predictions of the ASHRAE adaptive comfort standard and yet occupants required ‘more air velocity’. Minimum air velocity values were found in order to achieve 90% of thermal and air movement acceptability. From 24 to 27 °C the minimum air velocity for thermal and air movement acceptability is 0.4 m/s; from 27 to 29 °C is 0.41–0.8 m/s, and from 29 to 31 °C is >0.81 m/s. These results highlight the necessity of combining thermal and air movement acceptability in order to assess occupants’ perception of their indoor thermal environment in hot humid climates.  相似文献   

14.
A study was carried out to investigate the effect of heat-pipe air-handling coil on energy consumption in a central air-conditioning system with return air. Taking an office building as an example, the study shows that compared with conventional central air-conditioning system with return air, the heat-pipe air-conditioning system can save cooling and reheating energy. In the usual range of 22–26 °C indoor design temperature and 50% relative humidity, the RES (rate of energy saving) in this office building investigated is 23.5–25.7% for cooling load and 38.1–40.9% for total energy consumption. The RES of the heat-pipe air-conditioning system increases with the increase of indoor design temperature and the decrease of indoor relative humidity. The influence of indoor relative humidity on RES is much greater than the influence of the indoor design temperature. The study indicates that a central air-conditioning system can significantly reduce its energy consumption and improve both the indoor thermal comfort and air quality when a heat-pipe air-handling coil is employed in the air-conditioning process.  相似文献   

15.
The aim of this study is to develop a modeling methodology to assess thermal comfort and sensation of active people in transitional spaces and consider how comfort can be achieved by air movement while changing upper body clothing properties. The modeling is based on a bioheat model, capable of predicting segmental skin and core temperature from locally ventilated clothed body parts. The bioheat model is integrated with thermal comfort and sensation models to predict comfort in presence of air movement.The model accuracy in predicting comfort was validated by and agreed with the results of a survey administered to subjects wearing typical clothing at different activity levels to record their overall and local thermal sensation and comfort in a transitional space at Beirut summer climate. The transitional space temperature monitored during the experiments ranged between 27 °C and 30 °C.A parametric study is performed to assess thermal comfort in transitional spaces for different air movement levels and for three clothing designs. The high permeable clothing at 1.5 m/s and indoor temperature of 30 °C improved the Predicted Mean Vote to values less than 0.5 compared to 1.01 attained with typical low permeable clothing.  相似文献   

16.
The influence of the supply air temperature on the mean local air age and thermal comfort of a typical individual office under stratum ventilation is investigated by a numerical method, which is validated by an experiment carried out by the authors. The results show that for an office, when the supply air temperature is increased from 19 °C to 21 °C, the corresponding mean occupied zone temperature rises from 24.5 °C to 26.5 °C. The inhaled air quality for the occupant is improved when supply air temperature rises from 19 °C to 21 °C. Also, the thermal comfort indices (predicted mean vote or PMV, predicted percentage of dissatisfied or PPD and predicted dissatisfied or PD) fulfill the requirements of ISO 7730 and CR 175 1998. For summer cooling operation, stratum ventilation may offer a feasible solution to elevated indoor temperatures, which are recommended by several governments in East Asia.  相似文献   

17.
Thermal comfort, self‐reported acute health symptoms, cognitive performance, and physiological reactions were examined at four temperatures (26, 30, 33, and 37°C) at a relative humidity of 70%. Thirty‐two sub‐tropically acclimatized subjects experienced each condition for 175 minute, in balanced order, in a climatic chamber. The perception of heat gradually increased with increasing temperature, but the subjects felt hot only at 37°C. The temperature of 33°C was on average rated as acceptable and only just uncomfortable. The acceptability of air quality decreased linearly with increasing temperature. The intensity of acute health symptoms reported by the subjects increased with increasing temperature, but it was no more than moderate even at the highest temperature; dryness of skin and eye were alleviated. The eardrum temperature, skin temperature and moisture, heart rate, end‐tidal carbon dioxide, and weight loss increased significantly with increasing temperature, whereas the percentage of adjacent heart inter‐beat intervals differing by >50 ms decreased significantly. These results suggest that the perceived heat, self‐reported symptoms, and physiological reactions occurred concurrently. They show additionally that acclimatization to heat may shift the boundary of thermal discomfort to a higher temperature. The role of psychological adaptation and of the contextual aspects of this process still requires clarification in future experiments.  相似文献   

18.
Evaporative cooling has been proved as an effective method of storage of fruits and vegetables of moderate respiration rates. Therefore, a modified evaporative cooler named two-stage evaporative cooler (TSEC) has been developed to improve the efficiency of evaporative cooling for high humidity and low temperature air conditioning. Two-stage evaporative cooler consists of the heat exchanger and two evaporative cooling chambers. The performance of cooler has been evaluated in terms of temperature drop, efficiency of the evaporative cooling and effectiveness of TSEC over single evaporation. The temperature drop through TSEC ranged from 8 to 16 °C. With the several observations for diurnal runs, it was observed that TSEC could drop the temperature up to wet bulb depression of ambient air and provided the 90% relative humidity. Efficiency of single evaporation was 85–90%. Effectiveness of the two-stage evaporative cooling was found to be 1.1–1.2 over single evaporation. The two-stage evaporative cooler provided the room conditions as 17–25 °C temperature and 50–75% relative humidity, which can enable to enhance the shelf-life of wide range of fruit and vegetables of moderate respiration rates.  相似文献   

19.
Individually controlled microenvironment has potential to satisfy more occupants in a space compared to a total volume uniform environment typically used at present. The performance of an individually controlled system comprising a convection-heated chair, an under-desk radiant heating panel, a floor radiant heating panel, an under-desk air terminal device supplying cool air, and a desk-mounted personalized ventilation as used and identified by 48 human subjects was studied using a thermal manikin at room temperatures of 20 °C, 22 °C and 26 °C. At a room air temperature of 20 °C, the maximum whole-body heating effect of the heating chair, the under-desk heating panel, and the floor heating panel corresponded to the effect of a room temperature increase of 5.2 °C, 2.8 °C, and 2.1 °C, respectively. The effect was 5.9 °C for the combination of the three heating options. The higher the room air temperature, the lower the heating effect of each heating option or heating combination. The maximum whole-body cooling effect of the tested system was only −0.8 °C at a room air temperature of 26 °C. The heating and cooling capacity of the individually controlled system were identified. These results, analyzed together with results obtained from human subject experiments, reveal that both the heating and the cooling capacity of the individually controlled system need to be increased in order to satisfy most occupants in practice.  相似文献   

20.
This paper presents a thermal comfort study using a thermal manikin in a field environment chamber served by the Displacement Ventilation (DV) system. The manikin has a female body with 26 individually heated and controlled body segments. The manikin together with subjects was exposed to 3 levels of vertical air temperature gradients, nominally 1, 3 & 5 K/m, between 0.1 and 1.1 m heights at 3 room air temperatures of 20, 23 and 26 °C at 0.6 m height. Relative humidity at 0.6 m height and air velocity near the manikin and the subjects were maintained at 50% and less than 0.2 m/s, respectively. The aims of this study are to assess thermally non-uniform environment served by DV system using the manikin and correlate the subjective responses with measurements from the manikin. The main findings indicate that room air temperature had greater influence on overall and local thermal sensations and comfort than temperature gradient. Local thermal discomfort decreased with increase of room air temperature at overall thermally neutral state. The local discomfort was affected by overall thermal sensation and was lower at overall thermally neutral state than at overall cold and cool sensations.  相似文献   