首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The aim of this study is to develop a modeling methodology to assess thermal comfort and sensation of active people in transitional spaces and consider how comfort can be achieved by air movement while changing upper body clothing properties. The modeling is based on a bioheat model, capable of predicting segmental skin and core temperature from locally ventilated clothed body parts. The bioheat model is integrated with thermal comfort and sensation models to predict comfort in presence of air movement.The model accuracy in predicting comfort was validated by and agreed with the results of a survey administered to subjects wearing typical clothing at different activity levels to record their overall and local thermal sensation and comfort in a transitional space at Beirut summer climate. The transitional space temperature monitored during the experiments ranged between 27 °C and 30 °C.A parametric study is performed to assess thermal comfort in transitional spaces for different air movement levels and for three clothing designs. The high permeable clothing at 1.5 m/s and indoor temperature of 30 °C improved the Predicted Mean Vote to values less than 0.5 compared to 1.01 attained with typical low permeable clothing.  相似文献   

2.
The effect of vertical air temperature gradient on overall and local thermal comfort at different overall thermal sensations and room air temperatures (at 0.6 m height) was investigated in a room served by displacement ventilation system. Sixty tropically acclimatized subjects performed sedentary office work for a period of 3 h during each session of the experiment. Nominal vertical air temperature gradients between 0.1 and 1.1 m heights were 1, 3 and 5 K/m while nominal room air temperatures at 0.6 m height were 20, 23 and 26 °C. Air velocity in the space near the subjects was kept at below 0.2 m/s. Relative humidity at 0.6 m height was maintained at 50%. It was found that temperature gradient had different influences on thermal comfort at different overall thermal sensations. At overall thermal sensation close to neutral, only when room air temperature was substantially low, such as 20 °C, percentage dissatisfied of overall body increased with the increase of temperature gradient. At overall cold and slightly warm sensations, percentage dissatisfied of overall body was non-significantly affected by temperature gradient. Overall thermal sensation had significant impact on overall thermal comfort. Local thermal comfort of body segment was affected by both overall and local thermal sensations.  相似文献   

3.
This paper presents a study of local thermal sensation (LTS) and comfort in a field environmental chamber (FEC) served by displacement ventilation (DV) system. The FEC, 11.12 m (L)×7.53 m (W)×2.60 m (H), simulates a typical office layout. A total of 60 tropically acclimatized subjects, 30 male and 30 female, were engaged in sedentary office work for 3 h. Subjects were exposed to three vertical air temperature gradients, nominally 1, 3 and 5 K/m, between 0.1 and 1.1 m heights and three room air temperatures of 20, 23 and 26 °C at 0.6 m height. The objective of this study is to investigate the mutual effect of local and overall thermal sensation (OTS) and comfort in DV environment. The results show that in a space served by DV system, at OTS close to neutral, local thermal discomfort decreased with the increase of room air temperature. The OTS of occupants was mainly affected by LTS at the arm, calf, foot, back and hand. Local thermal discomfort was affected by both LTS and OTS. At overall cold thermal sensation, all body segments prefer slightly warm sensation. At overall slightly warm thermal sensation, all body segments prefer slightly cool sensation.  相似文献   

4.
Human response to air movement supplied locally towards the face was studied in a room with an air temperature of 20 °C and a relative humidity of 30%. Thirty-two human subjects were exposed to three conditions: calm environment and facially supplied airflow at 21 °C and at 26 °C. The air was supplied with a constant velocity of 0.4 m/s by means of personalized ventilation towards the face of the subjects. The airflow at 21 °C decreased the subjects' thermal sensation and increased draught discomfort, but improved slightly the perceived air quality. Heating of the supplied air by 6 K (temperature increase by 4 K at the target area) above the room air temperature decreased the draught discomfort, improved subjects' thermal comfort and only slightly decreased the perceived air quality. Elevated velocity and temperature of the localized airflow caused an increase of nose dryness intensity and number of eye irritation reports. Results suggest that increasing the temperature of the air locally supplied to the breathing zone by only a few degrees above the room air temperature will improve occupants' thermal comfort and will diminish draught discomfort. This strategy will extend the applicability of personalized ventilation aiming to supply clean air for breathing at the lower end of the temperature range recommended in the standards. Providing individual control is essential in order to avoid discomfort for the most sensitive occupants.  相似文献   

5.
It is difficult for a total air-conditioning system to satisfy the thermal comfort of all workers in an office. Therefore, an individually controlled system that can create a comfortable thermal environment for each worker is needed. In the present study, two chairs incorporating two fans each, one under the seat and one behind the backrest, were developed to provide isothermal forced airflow to the chair occupant. The chairs differed in the size of the fans. Experiments were conducted in a climate chamber during the summer. Seven subjects, who were healthy male college students, were allowed to freely control the two built-in fans by adjusting dials on the accompanying desk. The room air temperatures were set at 26 °C, 28 °C, 30 °C and 32 °C. The following findings were obtained. At a room air temperature of 28 °C, the whole-body thermal sensations were almost thermally neutral, regardless of the type of chair. At a room air temperature of 30 °C, the occupants were able to create acceptable thermal environments from the viewpoints of whole-body thermal sensation and comfort by using the chairs with fans. Their local discomfort rates at the back and lower back, which were affected by the isothermal airflows, were greatly improved at this room air temperature. However, at a room air temperature of 32 °C, the chairs tested in the present study were not able to provide acceptable thermal environments. In order to provide a more comfortable environment to the chair occupants, additional local systems to cool the head, arms, and hands are needed.  相似文献   

6.
The thermal environment for air-conditioned offices in subtropical climates is examined from the prospect of maintaining an optimum operative temperature for the occupants. In this study, the optimum neutral temperature is evaluated from 422 occupants’ responses towards the perceiving thermal environment in 61 air-conditioned offices and 186 complaints of thermal discomfort in an air-conditioned office building on an electronic questionnaire, using a semantic differential evaluation scale and a dichotomous assessment scale. In particular, physical parameters for the thermal comfort study were measured by an indoor environmental quality (IEQ) logger, and the operative temperature was correlated with the occupants’ thermal responses. The probability of accepting an operative temperature for the thermal comfort of the occupants was correlated with logistic regression curves; the optimum operative temperature was derived in order to maximize the probability of thermal comfort expressed by the occupants. The results showed that the thermal neutral temperatures for air-conditioned offices in subtropical climates were 23.6 and 21.4 °C in summer and winter, respectively. The preferred thermal environment in Hong Kong should be slightly cool, corresponding to about 1 °C below the neutral temperature, in order to satisfy most of the occupants in the office space.  相似文献   

7.
The summer season in the state of Kuwait is long with a mean daily maximum temperature of 45 °C. Domestic air conditioning is generally deployed from the beginning of April to the end of October. This accounts for around 75% of Kuwaiti electrical power consumption. In terms of energy conservation, increasing the thermostat temperature by 1 °C could save about 10% of space cooling energy 1 and 2. However, knowledge of indoor domestic temperatures and thermal comfort sensations is important to aid future advice formulation and policy-making related to domestic energy consumption. A field study was therefore conducted during the summers of 2006 and 2007 to investigate the indoor climate and occupants' thermal comfort in 25 air-conditioned domestic buildings in Kuwait. The paper presents statistical data about the indoor environmental conditions in Kuwait domestic residences, together with an analysis of domestic-occupant thermal comfort sensations. With respect to the latter, a total of 111 participants provided 111 sets of physical measurements together with subjective information via questionnaires that were used to collect the data. By using linear regression analysis of responses on the ASHRAE-seven-point thermal sensation scale, the neutral operative temperatures based on Actual Mean Vote (AMV) and Predicted Mean Vote (PMV) were found to be 25.2 °C and 23.3 °C, respectively, in the summer season. Findings from this study provide information about the indoor domestic thermal environment in Kuwait, together with occupant thermal comfort sensations. This knowledge can contribute towards the development of future energy-related design codes for Kuwait.  相似文献   

8.
Hypobaric conditions, with pressures about 20-30% below that at sea level, are often experienced at mountain resorts and plateau areas. The diffusive transfer of water evaporation increases at hypobaric conditions whereas dry heat loss by convection decreases. In order to clarify the effects of barometric on human thermal comfort, experiments are conducted in a decompression chamber where the air parameters were controllable. During experiments, air temperature is set at a constant of 20, air velocity is controlled at <0.1 m/s, 0.2 m/s, 0.25 m/s, and 0.3 m/s by stages. The barometric condition is examined stepwise for 1atm, 0.85 atm and 0.75 atm of simulated hypobaric conditions, which is equivalent to altitude of 0 m, 1300 m, and 2300 m respectively. Ten males and ten females in winter clothes participate in the experiments. Thermal sensations are measured with ASHRAE seven-point rating scales and skin temperatures were tested at each altitude. The main results are as follows: when the altitude rises, (1) the mean thermal sensation drops; (2) people become more sensitive to draught and expect lower air movements; (3) no significant change of mean skin temperature has been found. The results of the present study indicate that hypobaric environment tends to make people feel cooler.  相似文献   

9.
In the ASHRAE comfort database [1], underpinning the North American naturally ventilated adaptive comfort standard [2], the mean indoor air velocity associated with 90% thermal acceptability was relatively low, rarely exceeding 0.3 m/s. Post hoc studies of this database showed that the main complaint related to air movement was a preference for ‘more air movement’ 3 and 4. These observations suggest the potential to shift thermal acceptability to even higher operative temperature values, if higher air speeds are available. If that were the case, would it be reasonable to expect temperature and air movement acceptability levels at 90%? This paper focuses on this question and combines thermal and air movement acceptability percentages in order to assess occupants. Two field experiments took place in naturally ventilated buildings located on Brazil’s North-East. The fundamental feature of this research design is the proximity of the indoor climate observations with corresponding comfort questionnaire responses from the occupants. Almost 90% thermal acceptability was found within the predictions of the ASHRAE adaptive comfort standard and yet occupants required ‘more air velocity’. Minimum air velocity values were found in order to achieve 90% of thermal and air movement acceptability. From 24 to 27 °C the minimum air velocity for thermal and air movement acceptability is 0.4 m/s; from 27 to 29 °C is 0.41–0.8 m/s, and from 29 to 31 °C is >0.81 m/s. These results highlight the necessity of combining thermal and air movement acceptability in order to assess occupants’ perception of their indoor thermal environment in hot humid climates.  相似文献   

10.
Application of the exergy concept to research on the built environment is a relatively new approach. It helps to optimize climate conditioning systems so that they meet the requirements of sustainable building design. As the building should provide a healthy and comfortable environment for its occupants, it is reasonable to consider both the exergy flows in building and those within the human body.Until now, no data have been available on the relation between human-body exergy consumption rates and subjectively assessed thermal sensation. The objective of the present work was to relate thermal sensation data, from earlier thermal comfort studies, to calculated human-body exergy consumption rates.The results show that the minimum human body exergy consumption rate is associated with thermal sensation votes close to thermal neutrality, tending to the slightly cool side of thermal sensation.Generally, the relationship between air temperature and the exergy consumption rate, as a first approximation, shows an increasing trend. Taking account of both convective and radiative heat exchange between the human body and the surrounding environment by using the calculated operative temperature, exergy consumption rates increase as the operative temperature increases above 24 °C or decreases below 22 °C. With the data available so far, a second-order polynomial relationship between thermal sensation and the exergy consumption rate was established.  相似文献   

11.
Thermal environment that causes thermal discomfort may affect office work performance. However, the mechanisms through which occupants are affected are not well understood. This study explores the plausible mechanism linking room air temperature and mental alertness through perceptual and physiological responses in the tropics. Ninety-six young adults participated as voluntary subjects in a series of experiment conducted in the simulated office settings. Three room air temperatures, i.e. 20.0, 23.0 and 26.0 °C were selected as the experimental conditions. Both thermal comfort and thermal sensation changed significantly with time under all exposures (P < 0.0001). Longer exposure at 20.0 °C led to cooling sensations due to lower skin temperatures (P < 0.0001) and was perceived as the least comfortable. Nevertheless, this moderate cold exposure induced nervous system activation as demonstrated by the increase of α-Amylase level (P < 0.0001) and the Tsai–partington test (P < 0.0001). A mechanism linking thermal environment, occupants' responses and performance is proposed.  相似文献   

12.
Thermal comfort study of young Chinese people in Hong Kong   总被引:1,自引:0,他引:1  
The purpose of this study is to investigate the thermal comfort of college-age Chinese subjects and obtain the optimum thermal conditions for buildings. 134 college-age Chinese subjects wearing 0.6 clo standard clothing were exposed under sedentary activity for 3 h to several different thermal conditions. The neutral temperature of young Hong Kong Chinese was found to be 24.9°C. This is not significantly different from previous studies with Danish and American subjects. Using the probit technique for analysing subjective responses of thermal sensation the neutral zone was found to be between 22.2 and 25.2°C.  相似文献   

13.
Zhang's thermal comfort model [Zhang H. Human thermal sensation and comfort in transient and non-uniform thermal environments, Ph.D. thesis, UC Berkeley; 2003. 415 pp.] predicts that the local comfort of feet, hands, and face predominates in determining a person's overall comfort in warm and cool conditions. We took advantage of this in designing a task–ambient conditioning (TAC) system that heats only the feet and hands, and cools only the hands and face, to provide comfort in a wide range of ambient environments. Per workstation, the TAC system uses less than 41 W for cooling and 59 W for heating. We tested the TAC system on 18 subjects in our environmental chamber, at temperatures representing a wide range of practical winter and summer conditions (18–30 °C). A total of 90 tests were done. We measured subjects' skin and core temperatures, obtained their subjective responses about thermal comfort, perceived air quality, and air movement preference. The subjects performed three different types of tasks to evaluate their productivity during the testing. The TAC system maintains good comfort levels across the entire temperature range tested. TAC did not significantly affect the task performance of the occupants compared to a neutral ambient condition. Whenever air motion was provided, perceived air quality was significantly improved, even if the air movement was re-circulated room air. In our tests, subjects found thermal environments acceptable even if they were judged slightly uncomfortable (−0.5). By reducing the amount of control normally needed in the overall building, the TAC system saves energy. Simulated annual heating and cooling energy savings with the TAC system are as much as 40%.  相似文献   

14.
The recent Indian Railway budget proposes upgrading and development of fifty railway stations to world class standards. These stations act as crucial transport nodes for effective operation of the railway network and passenger well being. One of the important aspects regarding passenger satisfaction in these places is an acceptable thermal environment. This article studies the thermal comfort of passengers in a large and significant railway station in South India in the summer month of June. The study entails field measurements and questionnaire responses from 402 individuals over a period of fifteen days. The thermal comfort is estimated using the air temperature and the PET (Physiological Equivalent Temperature) scale. The neutral temperature obtained through questionnaire surveys is 31.93 °C. In presence of fair air movement, there is some relaxation to neutral temperature, although the range of relaxation is much narrower than the models presented by other researchers. Comparing the Thermal sensation votes (ASHRAE 7-point scale) with comfort votes (Bedford 7-point scale), it is observed that the passengers exhibit high tolerance and adaptivity. Further, some observations are made on the relationship between the nature of waiting areas and their spatial influence on passenger thermal comfort.  相似文献   

15.
This paper presents a thermal comfort study using a thermal manikin in a field environment chamber served by the Displacement Ventilation (DV) system. The manikin has a female body with 26 individually heated and controlled body segments. The manikin together with subjects was exposed to 3 levels of vertical air temperature gradients, nominally 1, 3 & 5 K/m, between 0.1 and 1.1 m heights at 3 room air temperatures of 20, 23 and 26 °C at 0.6 m height. Relative humidity at 0.6 m height and air velocity near the manikin and the subjects were maintained at 50% and less than 0.2 m/s, respectively. The aims of this study are to assess thermally non-uniform environment served by DV system using the manikin and correlate the subjective responses with measurements from the manikin. The main findings indicate that room air temperature had greater influence on overall and local thermal sensations and comfort than temperature gradient. Local thermal discomfort decreased with increase of room air temperature at overall thermally neutral state. The local discomfort was affected by overall thermal sensation and was lower at overall thermally neutral state than at overall cold and cool sensations.  相似文献   

16.
This field study was conducted during summer 2009 in Harbin, northeast of China in order to investigate human responses to the thermal conditions in naturally ventilated residential buildings in cold climate. We visited 257 families in six residential communities and collected 423 sets of physical data and subjective questionnaires. The neutral temperature is 23.7 °C, with the clothing insulation of 0.54 clo. The neutral temperature in Harbin is lower than neutral temperatures in warm climates by others, which is in accordance with the thermal adaptive model. 80% of the occupants can accept the air temperature range of 21.5-31.0 °C, which is wider than the summer comfort temperature limits by the adaptive model. The preferred temperature range fell between 24.0 °C and 28.0 °C. About 57.9% of the subjects voted “no change” with the humid range of 40% and 70%. 61.5% of the occupants voted “no change” with the air velocity within the range of 0.05-0.30 m/s. In summer, occupants preferred air velocity of lower than 0.25 m/s even at higher indoor temperature, which is different from the other field studies. The Harbin occupants in naturally ventilated dwellings can achieve thermal comfort by operable windows instead of running air-conditioners.  相似文献   

17.
《Building and Environment》2005,40(8):1051-1067
The purpose of this paper is to investigate using a numerical simulation (computational fluid dynamics or CFD) the effect of the air supply location on the design and performance of the displacement ventilation (DV) system. The results are reported in terms of thermal comfort and indoor air quality. The study focuses on the typical Hong Kong office under local thermal and boundary conditions. This includes the high cooling load used in Hong Kong. Several pollutants typically found in the office such as carbon dioxide and volatile organic compounds (VOCs) were investigated. The results indicate that the supply should be located near the center of the room rather than to one side of the room. This will provide a more uniform thermal condition in the office. The DV system was found to be effective in dispersing VOCs within an office environment for all cases studied. The exhaust was found to have minimal effect on the thermal comfort. For a DV system in Hong Kong, it is possible to use 100% fresh air without extra energy consumption.  相似文献   

18.
In hot humid climates, natural ventilation is an essential passive strategy in order to maintain thermal comfort inside buildings and it can be also used as an energy-conserving design strategy to reduce building cooling loads by removing heat stored in the buildings thermal mass. In this context, many previous studies have focused on thermal comfort and air velocity ranges. However, whether this air movement is desirable or not remains an open area. This paper aims to identify air movement acceptability levels inside naturally ventilated buildings in Brazil. Minimal air velocity values corresponding to 80% and 90% (V80 and V90) air movement acceptability inside these buildings. Field experiments were performed during hot and cool seasons when 2075 questionnaires were filled for the subjects while simultaneous microclimatic observations were made with laboratory precision. Main results indicated that the minimal air velocity required were at least 0.4 m/s for 26 °C reaching 0.9 m/s for operative temperatures up to 30 °C. Subjects are not only preferring more air speed but also demanding air velocities closer or higher than 0.8 m/s ASHRAE limit. This dispels the notion of draft in hot humid climates and reinforce the broader theory of alliesthesia and the physiological role of pleasure due to air movement increment.  相似文献   

19.
At room temperatures ranging from 28 to 35 °C, the three sensitive body parts face, chest and back were exposed to local cooling airflow, whose temperatures ranged from 22 to 28 °C. Dressed in shorts, 30 randomly selected male subjects were exposed to each condition for 30 min and reported their local thermal sensations of all body parts, overall thermal sensation and thermal acceptability on voting scales at regular intervals. It was shown that local exposure affected local thermal sensations of the unexposed body parts significantly, based on which a new influencing factor method was proposed. Influencing factor and weighting factor for each body part are unaffected by room or cooling air temperatures under steady state and the predictive model of overall thermal sensation was obtained using influencing and weighting factors. Taking the maximum thermal sensation difference between body parts to represent non-uniformity of thermal sensation, a new assessment model for non-uniform thermal environment was proposed. The model shows that the upper boundary of the acceptable room temperature range can be shifted from 26 to 30.5 °C while face cooling is provided.  相似文献   

20.
Results of an indoor environment survey in a large underground car park in Hong Kong are reported in this paper. Field measurements were divided into three parts: (1) assessment of the thermal environment; (2) measurement of the carbon monoxide concentration; and (3) a survey on thermal comfort. The indoor air temperature, relative humidity, instantaneous airspeeds, turbulence intensity, and carbon monoxide concentration at different locations in the car park were measured. Design and operation of the installed ventilation systems were studied and the number of cars staying at the car park was investigated. Correlation relationships between the mean carbon monoxide and the mean air speed, the turbulence intensity, and the number of cars entering or leaving the car park were derived. Field studies of this kind are very important for providing ventilation system design data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏