1.
Air change rate (ACR) data obtained from the bedrooms of 500 Danish children and presented in an earlier paper were analyzed in more detail. Questionnaires distributed to the families, home inspections and interviews with the parents provided information about a broad range of residential characteristics and occupant behavior. These were tested in several linear regression models to identify the degree of effect each selected independent variable has on the total ACR. The measured ACRs are summarized by some of the most significant variables such as room volume (higher ACR in smaller rooms), number of people sleeping in the bedroom (higher ACR with more people), average window and door opening habits (higher ACR with more opening), sharing the bedroom with other family members (higher ACR in shared rooms), location of the measured room (higher ACR above ground floor), year of construction (lowest ACR in buildings from early 1970s), observed condensation on the bedroom window (higher ACR at less condensation), etc. The best-fitting model explained 46% of the variability in the air change rates. Variables related to occupant behavior were stronger predictors of ventilation rate (model R2 = 0.30) than those related to building characteristics (model R2 = 0.09). Although not perfectly accurate on a room-to-room basis, our best-fitting model may be useful when a rough estimate of the average air change rate for larger study populations is required in future indoor air quality models.  相似文献   

2.
The aim of the study was to test the hypothesis that a low-ventilation rate in homes is associated with an increased prevalence of asthma and allergic symptoms among children. A total of 198 cases (with at least two of three symptoms: wheezing, rhinitis, eczema) and 202 healthy controls, living in 390 homes, were examined by physicians. Ventilation rates were measured by a passive tracer gas method, and inspections were carried out in the homes. About 60% of the multi-family houses and about 80% of the single-family houses did not fulfill the minimum requirement regarding ventilation rate in the Swedish building code (0.5 air changes per hour, ach). Cases had significantly lower ventilation rates than controls and a dose-response relationship was indicated. PRACTICAL IMPLICATIONS: A low-ventilation rate of homes may be a risk factor for allergies among children. Families with allergic children should be given the advice to have good ventilation in the home. In investigations, of associations between environmental factors and allergies, the air change rate in homes has to be considered.  相似文献   

3.
The ventilation modalities in most Chinese residences are infiltration and opening windows. We measured infiltration rates and air change rates at night, with no attempt to change occupants' behaviors, of urban residences in five climate zones of China during four seasons. Using the CO2 decay method, we found the median infiltration rate for 294 residences to be 0.34 h?1. Using occupant‐generated CO2 as tracer gas, we determined air change rates over the course of 1 year in 46 bedrooms at night from mass balance considerations. In 54% of the measurements, windows were closed, so ventilation was only by infiltration. Windows were mainly closed when the outdoor temperature was below 15°C and above 26°C. The median infiltration rates did not differ appreciably among seasons and climate zones and were always less than 0.45 h?1.  相似文献   

4.
Mechanical ventalation system performance involves the provision of adequate amuunts of outdoor air, uniform distribution of ventilation air within the occupied space, and the maintenance of thermal comfort. Standard measurement techniques exist to evaluate thermal comfort and air change rates in mechanically ventilated buildings; procedures to evaluate air distribution or ventilation effectiveness in the field are still being developed. This paper presents measuremetlts of air change rates and ventilation effectivenes in an office/library building in Washington, DC. The tracer gas decay technique was used to measure whole building air change rates. The air change rates during the measurement period were essentially constant at about 0.8 air changes per hour, somewhat below the design specification and above the minimum recmmmded in ASHRAE Standard 62-1989. Ventilation effectiveness was investigated at several locations within the building through the measurement of local tracer gas decay rate and mean local age of air. The ventilation effectiveness measurements serve as an investigation of the applicability of the m e a s u r r n procedures employed, providing insight into the measurement issue of establishing initial conditions, the spatial variation in test results within a building, and the repeatabildy between tests. The results of the ventilation effectiveness meusurements are consistent with good distrhtion of the outdoor air by the ventilation system and good mixing within the occupied space.  相似文献   

5.
Research shows that poor indoor air quality (IAQ) in school buildings can cause a reduction in the students’ performance assessed by short-term computer-based tests; whereas good air quality in classrooms can enhance children's concentration and also teachers’ productivity. Investigation of air quality in classrooms helps us to characterise pollutant levels and implement corrective measures. Outdoor pollution, ventilation equipment, furnishings, and human activities affect IAQ. In school classrooms, the occupancy density is high (1.8–2.4 m2/person) compared to offices (10 m2/person). Ventilation systems expend energy and there is a trend to save energy by reducing ventilation rates. We need to establish the minimum acceptable level of fresh air required for the health of the occupants. This paper describes a project, which will aim to investigate the effect of IAQ and ventilation rates on pupils’ performance and health using psychological tests. The aim is to recommend suitable ventilation rates for classrooms and examine the suitability of the air quality guidelines for classrooms. The air quality, ventilation rates and pupils’ performance in classrooms will be evaluated in parallel measurements. In addition, Visual Analogue Scales will be used to assess subjective perception of the classroom environment and SBS symptoms. Pupil performance will be measured with Computerised Assessment Tests (CAT), and Pen and Paper Performance Tasks while physical parameters of the classroom environment will be recorded using an advanced data logging system. A total number of 20 primary schools in the Reading area are expected to participate in the present investigation, and the pupils participating in this study will be within the age group of 9–11 years. On completion of the project, based on the overall data recommendations for suitable ventilation rates for schools will be formulated.  相似文献   

6.
The article reports on an experiment which investigated the effect of increased classroom ventilation rate on the performance of children aged 10–12 years. The experiment was executed at two different schools (two classrooms at each school) as a double‐blind 2 × 2 crossover intervention where four different performance tests were used as surrogates for short‐term concentration and logical thinking. Only complete pairs of test responses were included in the within‐subject comparisons of performance, and data were not corrected for learning and fatigue effects. Analysis of the total sample suggested the number of correct answers was improved significantly in four of four performance test, addition (6.3%), number comparison (4.8%), grammatical reasoning (3.2%), and reading and comprehension (7.4%), when the outdoor air supply rate was increased from an average of 1.7 (1.4–2.0) to 6.6 l/s per person. The increased outdoor air supply rate did not have any significant effect on the number of errors in any of the performance tests. Results from questionnaires regarding pupil perception of the indoor environment, reported Sick Building Syndrome symptoms, and motivation suggested that the study classroom air was perceived more still and pupil were experiencing less pain in the eyes in the recirculation condition compared to the fresh air condition.  相似文献   

7.
The scientific literature through 2005 on the effects of ventilation rates on health in indoor environments has been reviewed by a multidisciplinary group. The group judged 27 papers published in peer-reviewed scientific journals as providing sufficient information on both ventilation rates and health effects to inform the relationship. Consistency was found across multiple investigations and different epidemiologic designs for different populations. Multiple health endpoints show similar relationships with ventilation rate. There is biological plausibility for an association of health outcomes with ventilation rates, although the literature does not provide clear evidence on particular agent(s) for the effects. Higher ventilation rates in offices, up to about 25 l/s per person, are associated with reduced prevalence of sick building syndrome (SBS) symptoms. The limited available data suggest that inflammation, respiratory infections, asthma symptoms and short-term sick leave increase with lower ventilation rates. Home ventilation rates above 0.5 air changes per hour (h(-1)) have been associated with a reduced risk of allergic manifestations among children in a Nordic climate. The need remains for more studies of the relationship between ventilation rates and health, especially in diverse climates, in locations with polluted outdoor air and in buildings other than offices. PRACTICAL IMPLICATIONS: Ventilation with outdoor air plays an important role influencing human exposures to indoor pollutants. This review and assessment indicates that increasing ventilation rates above currently adopted standards and guidelines should result in reduced prevalence of negative health outcomes. Building operators and designers should avoid low ventilation rates unless alternative effective measures, such as source control or air cleaning, are employed to limit indoor pollutant levels.  相似文献   

8.
Student attendance in American public schools is a critical factor in securing limited operational funding. Student and teacher attendance influence academic performance. Limited data exist on indoor air and environmental quality (IEQ) in schools, and how IEQ affects attendance, health, or performance. This study explored the association of student absence with measures of indoor minus outdoor carbon dioxide concentration (dCO(2)). Absence and dCO(2) data were collected from 409 traditional and 25 portable classrooms from 22 schools located in six school districts in the states of Washington and Idaho. Study classrooms had individual heating, ventilation, and air conditioning (HVAC) systems, except two classrooms without mechanical ventilation. Classroom attributes, student attendance and school-level ethnicity, gender, and socioeconomic status (SES) were included in multivariate modeling. Forty-five percent of classrooms studied had short-term indoor CO(2) concentrations above 1000 p.p.m. A 1000 p.p.m. increase in dCO(2) was associated (P < 0.05) with a 0.5-0.9% decrease in annual average daily attendance (ADA), corresponding to a relative 10-20% increase in student absence. Annual ADA was 2% higher (P < 0.0001) in traditional than in portable classrooms. PRACTICAL IMPLICATIONS: This study provides motivation for larger school studies to investigate associations of student attendance, and occupant health and student performance, with longer term indoor minus outdoor CO(2) concentrations and more accurately measured ventilation rates. If our findings are confirmed, improving classroom ventilation should be considered a practical means of reducing student absence. Adequate or enhanced ventilation may be achieved, for example, with educational training programs for teachers and facilities staff on ventilation system operation and maintenance. Also, technological interventions such as improved automated control systems could provide continuous ventilation during occupied times, regardless of occupant thermal comfort demands.  相似文献   

9.
Poor conditions leading to substandard indoor air quality (IAQ) in classrooms have been frequently cited in the literature over the past two decades. However, there is limited data linking poor IAQ in the classrooms to student performance. Whereas, it is assumed that poor IAQ results in reduced attendance and learning potential, and subsequent poor student performance, validating this hypothesis presents a challenge in today's school environment. This study explores the association between student performance on standardized aptitude tests that are administered to students on a yearly basis, to classroom carbon dioxide (CO2) concentrations, which provide a surrogate of ventilation being provided to each room. Data on classroom CO2 concentrations (over a 4-5 h time span within a typical school day) were recorded in fifth grade classrooms in 54 elementary schools within a school district in the USA. Results from this preliminary study yield a significant (P < 0.10) association between classroom-level ventilation rate and test results in math. They also indicate that non-linear effects may need to be considered for better representation of the association. A larger sample size is required in order to draw more definitive conclusions. Practical Implications Future studies could focus on (1) gathering more evidence on the possible association between classroom ventilation rates and students' academic performance; (2) the linear/non-linear nature of the association; and (3) whether it is possible to detect 'no observed adverse effect level' for adequate ventilation with respect to academic performance in schools. All of this information could be used to improve guidance and take regulatory actions to ensure adequate ventilation in schools. The high prevalence of low ventilation rates, combined with the growing evidence of the positive impact that sufficient ventilation has on human performance, suggests an opportunity for improving design and management of school facilities.  相似文献   

10.
Several studies have reported poor indoor air quality (IAQ) in day care centers (DCCs), and other studies have shown that children attending them have an increased risk of respiratory and gastrointestinal infections. The aim of this study was to investigate whether there is an association between ventilation in DCCs and sick leave among nursery children. Data on child sick leave within an 11‐week period were obtained for 635 children attending 20 DCCs. Ventilation measurements included three proxies of ventilation: air exchange rate (ACR) measured with the decay method, ACR measured by the perfluorocarbon tracer gas (PFT) method, and CO2 concentration measured over a 1‐week period. All but two DCCs had balanced mechanical ventilation system, which could explain the low CO2 levels measured. The mean concentration of CO2 was 643 ppm, exceeding 1000 ppm in only one DCC. A statistically significant inverse relationship between the number of sick days and ACR measured with the decay method was found for crude and adjusted analysis, with a 12% decrease in number of sick days per hour increase in ACR measured with the decay method. This study suggests a relationship between sick leave among nursery children and ventilation in DCCs, as measured with the decay method.  相似文献   

11.
This paper reviews current literature on the associations of ventilation rates and carbon dioxide concentrations in non-residential and non-industrial buildings (primarily offices) with health and other human outcomes. Twenty studies, with close to 30,000 subjects, investigated the association of ventilation rates with human responses, and 21 studies, with over 30,000 subjects, investigated the association of carbon dioxide concentration with these responses. Almost all studies found that ventilation rates below 10 Ls-1 per person in all building types were associated with statistically significant worsening in one or more health or perceived air quality outcomes. Some studies determined that increases in ventilation rates above 10 Ls-1 per person, up to approximately 20 Ls-1 per person, were associated with further significant decreases in the prevalence of sick building syndrome (SBS) symptoms or with further significant improvements in perceived air quality. The carbon dioxide studies support these findings. About half of the carbon dioxide studies suggest that the risk of sick building syndrome symptoms continued to decrease significantly with decreasing carbon dioxide concentrations below 800 ppm. The ventilation studies reported relative risks of 1.5-2 for respiratory illnesses and 1.1-6 for sick building syndrome symptoms for low compared to high low ventilation rates.  相似文献   

12.
Seppänen O  Fisk WJ  Lei QH 《Indoor air》2006,16(1):28-36
Outdoor air ventilation rates vary considerably between and within buildings, and may be too low in some spaces. The purpose of this study was to evaluate the potential work performance benefits of increased ventilation. We analyzed the literature relating work performance with ventilation rate and employed statistical analyses with weighting factors to combine the results of different studies. The studies included in the review assessed performance of various tasks in laboratory experiments and measured performance at work in real buildings. Almost all studies found increases in performance with higher ventilation rates. The studies indicated typically a 1-3% improvement in average performance per 10 l/s-person increase in outdoor air ventilation rate. The performance increase per unit increase in ventilation was bigger with ventilation rates below 20 l/s-person and almost negligible with ventilation rates over 45 l/s-person. The performance increase was statistically significant with increased ventilation rates up to 15 l/s-person with 95% CI and up to 17 l/s-person with 90% CI. Practical Implications We have demonstrated a quantitative relationship between work performance and ventilation within a wide range of ventilation rates. The model shows a continuous increase in performance per unit increase in ventilation rate from 6.5 l/s-person to 65 l/s-person. The increase is statistically significant up to 15 l/s-person. This relationship has a high level of uncertainty; however, use of this relationship in ventilation design and feasibility studies may be preferable to the current practice, which ignores the relationship between ventilation and productivity.  相似文献   

13.
Scientific literature on the effects of ventilation on health, comfort, and productivity in non-industrial indoor environments (offices, schools, homes, etc.) has been reviewed by a multidisciplinary group of European scientists, called EUROVEN, with expertise in medicine, epidemiology, toxicology, and engineering. The group reviewed 105 papers published in peer-reviewed scientific journals and judged 30 as conclusive, providing sufficient information on ventilation, health effects, data processing, and reporting, 14 as providing relevant background information on the issue, 43 as relevant but non-informative or inconclusive, and 18 as irrelevant for the issue discussed. Based on the data in papers judged conclusive, the group agreed that ventilation is strongly associated with comfort (perceived air quality) and health [Sick Building Syndrome (SBS) symptoms, inflammation, infections, asthma, allergy, short-term sick leave], and that an association between ventilation and productivity (performance of office work) is indicated. The group also concluded that increasing outdoor air supply rates in non-industrial environments improves perceived air quality; that outdoor air supply rates below 25 l/s per person increase the risk of SBS symptoms, increase short-term sick leave, and decrease productivity among occupants of office buildings; and that ventilation rates above 0.5 air changes per hour (h-1) in homes reduce infestation of house dust mites in Nordic countries. The group concluded additionally that the literature indicates that in buildings with air-conditioning systems there may be an increased risk of SBS symptoms compared with naturally or mechanically ventilated buildings, and that improper maintenance, design, and functioning of air-conditioning systems contributes to increased prevalence of SBS symptoms.  相似文献   

14.
The purpose of the study was to gather information about the actual ventilation and indoor air quality and to evaluate the differences between houses and apartments with different ventilation systems. A sample of 242 dwellings in the Helsinki metropolitan area was studied over periods of no weeks during the 1988-1989 heating season. The mean air-exchange rates had a high variation (average 0.52 l/h, range 0.07-1.55 l/h). The ASHRAE minimum value of 0.35 l/h was not achieved in 28% of the dwellings. The air-exchange rates were significantly her in the houses than in the apartments (averages 0.45/0.64 l/h, p < 0.001); in the natural ventilation systems they, were slightly her than in the mechanical systems. The average temperature in the bedrooms was approximately 22 °C (range 18–27 °C), slightly but significantly higher in the apartment than in the houses. The average dust depositions were higher in the balanced ventilation systems than in the other systems. The median radon concentration was 82 Bq/m3 (range 5-866 Bq/m3); the Finnish target value of 200 Bq/m3 was exceeded in 17% of the houses but in none of the apartment. The measurements indicate that the indoor air quality in Finnish dwellings is not always satisfactory with reference to human health and comfort.  相似文献   

15.
A new turbinemeter has been developed to be used as a ventilation rate sensor in livestock buildings. On the basis of a previous sensor introduced in 1983, several improvements have been made to develop a low-cost airflow rate sensor with an acceptable accuracy of 60 m3/h in a range from 200 to 5000 m3/h for pressure differences from 0 to 120 Pa. This sensor can be integrated in the climate control equipment of livestock buildings to improve process control.  相似文献   

16.
The ventilation performance of a naturally ventilated classroom was investigated to monitor the CO2 levels and compare compliance with new guidelines. Measurements of CO2 levels were taken for 1 week during the heating season while different ventilation modes were investigated.  相似文献   

17.
In buildings which were built within the last 15 to 20 years, or which have been retrofitted, and which do notfeature a mechanical ventilation system, air changes between 0.01 h?1 and 0.5 h?1 were measured while windows were closed. In the bedrooms of such buildings, when doors and windows were closed, CO2 concentrations of up to 4300 ppm were measured whereby the 1500 ppm limit was often exceeded. Simulation calculations and diverse measurements using different door positions with simultaneously closed windows have shown that with the door open more than 10 cm, and a minimal air exchange in the whole of an apartment of 0.1 h?1, a CO2 concentration of I500 ppm was not or was only insignifiantly exceeded even after 10 hours. Investigations in a dwelling fined with a mechanical ventilation system have shown that air quality and the indoor climate parameters were in an optimal range.  相似文献   

18.
Poor air quality in schools has been associated with adverse health effects. Indoor air quality can be improved by increasing ventilation. The objective of this study was to compare the effectiveness of different interventions to improve ventilation behavior in primary schools. We used indoor CO(2) concentrations as an indicator. In 81 classes of 20 Dutch primary schools, we applied three different interventions: (i) a class-specific ventilation advice; (ii) the advice combined with a CO(2) warning device and (iii) the advice combined with a teaching package. The effectiveness of the interventions was tested directly after intervention and 6 weeks after intervention by measuring the CO(2) concentrations and comparison with a control group (iv). Before intervention, the CO(2) concentration exceeded 1000 ppm for 64% of the school day. The class-specific ventilation advice without further support appeared an ineffective tool to improve ventilation behavior. The advice in combination with a CO(2) warning device or the teaching package proved effective tools and resulted in lower indoor CO(2) concentrations when compared with the control group. Ventilation was significantly improved, but CO(2) concentrations still exceeded 1000 ppm for more than 40% of the school day. Hence, until ventilation facilities are upgraded, the CO(2) warning device and the teaching package are useful low-cost tools. PRACTICAL IMPLICATIONS: To improve ventilation behavior and indoor air quality in schools, CO(2) warning device and teaching package combined with a class-specific ventilation advice, are effective tools, while giving the ventilation advice solely, is not effective. Although ventilation is significantly improved through behavioral change, the ventilation rate is still insufficient to maintain good air quality during the full school day. Therefore, the improvement of the ventilation facilities is recommended. Hence, until ventilation facilities in schools are upgraded, the CO(2) warning device and the teaching package are useful low-cost tools to improve current indoor air quality.  相似文献   

19.
The spatial distribution of CO2 level in a classroom carried out in previous field work research has demonstrated that there is some evidence of variations in CO2 concentration in a classroom space. Significant fluctuations in CO2 concentration were found at different sampling points depending on the ventilation strategies and environmental conditions prevailing in individual classrooms. However, how these variations are affected by the emitting sources and the room air movement remains unknown. Hence, it was concluded that detailed investigation of the CO2 distribution need to be performed on a smaller scale. As a result, it was decided to use an environmental chamber with various methods and rates of ventilation, for the same internal temperature and heat loads, to study the effect of ventilation strategy and air movement on the distribution of CO2 concentration in a room. The role of human exhalation and its interaction with the plume induced by the body's convective flow and room air movement due to different ventilation strategies were studied in a chamber at the University of Reading. These phenomena are considered to be important in understanding and predicting the flow patterns in a space and how these impact on the distribution of contaminants. This paper attempts to study the CO2 dispersion and distribution at the exhalation zone of two people sitting in a chamber as well as throughout the occupied zone of the chamber. The horizontal and vertical distributions of CO2 were sampled at locations with a probability that CO2 variation is considered high. Although the room size, source location, ventilation rate and location of air supply and extract devices all can have influence on the CO2 distribution, this article gives general guidelines on the optimum positioning of CO2 sensor in a room.  相似文献   

20.
Abstract Adjustment of ventilation rates in buildings is widely practised, both to provide good air quality on a proactive basis and to mitigate air quality problems associated with occupant complaints. However, both cross-sectional and experimental epidemiological studies have reported mixed results and have for the most part failed to establish definitive relationships between ventilation rates and symptom prevalence or dissatisfaction with air quality. The difficulties involved in establishing such relationships may be due to a variety of confounding factors which include limitations in study design and interaction effects; difficulties in controlling ventilation rates in experimental studies; inadequate mixing of supply air in occupied spaces; high source strengths for some contaminants; dynamic interactions between sources and ventilation rates that result in increased contaminant emissions; contaminant dose-response sensory effects which are log-linear; potential contaminant generation within ventilation systems themselves; and multifactorial genesis of sick building symptoms. There is limited evidence to suggest that ventilation rate increases up to 10 L/s person may be effective in reducing symptom prevalence and occupant dissatisfaction with air quality and that higher ventilation rates are not effective. Because of complex relationships between ventilation rates, contaminant levels, and building-related health complaints/dissatisfaction with air quality, the use of ventilation as a mitigation measure for air quality problems should be tempered with an understanding of factors which may limit its effectiveness.  相似文献   